Extron Electronics Cable Cubby 700 User Manual

Cable Cubby 500 and 700 • Installation Guide
Connectivity Bracket
Cable Grommet Plate
Cable Cubby 700
125V~ 12A MAX
TOTAL
Hole Plugs
Connectivity Bracket
Cable Grommet Plate
AAP Frame Plate
Cable Cubby 500
Cable Cubby 700
Zip Ties
Tweeker
AC Power Module
125V~ 12A MAX
TOTAL
#6 Mounting Screws
and Star Washers
#4-40 Module Scr
Cable Grommet Plate
AAP Frame Plate
AC Power Module
125V~ 12A MAX
TOTAL
Cable Grommet Plate
125V~ 12A MAX
TOTAL
Hole Plugs
Connectivity Bracket
Cable Grommet Plate
Cable Cubby 500
Cable Cubby 700
Zip Ties
125V~ 12A MAX
TOTAL
Cable Grommet Plate
AAP Frame Plate
Cable Cubby 700
Tweeker
AC Power Module
125V~ 12A MAX
TOTAL
and Screws
Retractor Pin & Clip
Cable Grommet Plate
AAP Frame Plate
AC Power Module
125V~ 12A MAX
TOTAL
Retractor Pin & Clip
Hole Plugs
Connectivity Bracket
Cable Grommet Plate
AAP Frame Plate
Cable Cubby 500
Cable Cubby 700
Zip Ties
Tweeker
AC Power Module
125V~ 12A MAX
TOTAL
and Star Washers
This guide provides instructions for an experienced installer to install and connect the Extron Cable Cubby 500 and 700 Cable Access Enclosures.
Planning
Check with local and state regulations before starting the installation:
Ensure that the planned installation complies with building and electrical codes. Ensure that the planned installation complies with the Americans with Disabilities Act or
other accessibility requirements.
Check all parts and equipment before installation:
Ensure that all parts are present in each kit. Ensure that necessary tools and equipment are available for the installation.
IMPORTANT:
Go to www.extron.com for the
complete user guide, installation
instructions, and specifications.
Kit Contents
Retractor Trim
ews
Cable Cubby 500 Cable Cubby 700
1 2
2 4
1 2
1 2
(3) 3/8", (1) 1/4" (6) 3/8", (2) 1/4"
1 trim, 2 screws 2 trims, 4 screws
#6 Mounting Screws
1 2
4 8
1
Cable Cubby 500 and 700 • Installation Guide (Continued)
x.x"
(x.x cm)
x.x"
(x.x cm)
x.x"
(x.x cm)
x.x"
(x.x cm)
30
Table Top
x.x"
(x.x cm)
x.x"
(x.x cm)
XL Models
x.x"
(x.x cm)
x.x"
(x.x cm)
x.x"
(x.x cm)
XL Models
(23.1 cm)
Cut-Out Template for the Extron
Cable Cubby 500
0.25"
(0.635 cm) R
5.75"
(14.60 cm)
5.75"
(14.60 cm)
2.0"
Trim Rings Outer Edge
(Do not cut this line.)
Table Clamp
P/N 68-8599-01 Rev. A
SURFACE
CUT-OUT
AREA
1. Confirm the product to be installed.
2. Remove the surface cut-out area
(gray) from the template.
3. Measure the cutout and template .
4. Mark the position on the
furniture where the Cable Cubby 500
will be installed.
5. Double check dimensions and position,
then cut the opening.
Page Size: 11" x 17" Print Scale 1:1
Do not Shrink
CutO
C
Cab
Preparing the Table
Cut a hole in the surface where the enclosure will be installed. Read the following information before making a cut.
Determine the best location for the enclosure
Ensure that the location where the Cable Cubby is to be installed is convenient for as many users as possible. Ensure that the edge on which the lid opens is oriented correctly. Ensure that there is ample space under the table for cables. When installing retractors in the Cable Cubby, ensure that there is enough space for the retractor assembly under the table or
furniture (ee dimensions for the retractors below).
NOTES:
To prevent objects from impeding cable retraction, ensure at least 3 inches of clearance from the exposed cable side of
the enclosure (see the diagrams below).
Excess cabling may cause clearance issues. Use zip ties to secure under-table cabling to prevent accidental contact or
entanglement (see Routing and Connecting Cables on page 6).
Table Top
15.9"
9.1"
3.0"
(7.6 cm)
3.0"
(7.6 cm)
XL Models
Choose a method for cutting the hole in the table
ATTENTION: The opening in the table for the Cable Cubby should be cut only by licensed and bonded craftspeople.
Exercise care to prevent scarring or damaging the furniture.
ATTENTION: L’ouverture dans la table pour le CableCubby devrait être coupée seulement par des artisans autorisés et
qualiés. Faites attention à ne pas faire de marques sur le meuble et à ne pas l’endommager.
CAUTION: Wear safety glasses when operating power equipment. Failure to comply can result in eye injury.
(40.4 cm)
21.9"
(55.6 cm)
ATTENTION: Portez des lunettes de sécurité lorsque vous utilisez l’équipement électrique. Ne pas respecter cela peut
conduire à une blessure à l’oeil.
(59.7 cm)
23.5"
29.4"
(74.7 cm)
XL Models
30
10.6"
(26.9 cm)
26.7"
(67.8 cm)
Choose one of the following methods for cutting the hole:
Hand Router and Routing Template Jigsaw and Paper Cut-Out Template CNC Wood Router
Jigsaw
If using a CNC wood router or other precise machinery, use the exact cut-out dimensions for your model
Visit www.extron.com for Cable Cubby routing template part numbers and instructions.
Cut-Out Template for the Extron
2.0"
Ta
b le Clamp
Trim Ring
0.25"
Lip Width
+
0.00
0.02 ” (
0.00
(0.0
cm)
5 c
m)
User Access
Trim Ring’s
(Do not c
ut th
Cable Cubby 500
Page Size: 11" x 17" Print Scale 1:1
Do not Shrink
1. Confirm the pr
2. Remove the surface cut-out area
(gray) f
3. M
4. Mark the position on the
furniture where the Cable Cubby 500
easure the cutout and template.
will be installed.
rom the template.
5. Double check oduct to be installed.
then cut the opening.
Outer Edge is line.)
P/N
68-859
dimensions and position,
9-01 Rev. A
Dimensions and cut-out templates are available online at www.extron.com.
(see the table below).
Cut-out Dimensions
Product
User Access
Width
CC 500 5.75"
(14.6 cm)
CC 700 7.125"
(18.1 cm)
2
Side
Dimension
5.75"
(14.6 cm)
5.75"
(14.6 cm)