Extron electronics Cable Cubby 500, Cable Cubby 700, Cable Cubby 500 CCB Installation Manual

complete user guide
instructions, and specifications.
Cable Cubby 500 and 700 • Installation Guide
Connectivity Bracket
Cable Grommet Plate
Cable Cubby 700
125V~ 12A MAX TOTAL
Hole Plugs
Connectivity Bracket
Cable Grommet Plate
AAP Frame Plate
Cable Cubby 500
Cable Cubby 700
Zip Ties
Tweeker
AC Power Module
125V~ 12A MAX TOTAL
#6 Mounting Screws
and Star Washers
#4-40 Module Scr
Cable Grommet Plate
AAP Frame Plate
AC Power Module
125V~ 12A MAX TOTAL
Cable Grommet Plate
125V~ 12A MAX
TOTAL
Hole Plugs
Connectivity Bracket
Cable Grommet Plate
Cable Cubby 500
Cable Cubby 700
Zip Ties
125V~ 12A MAX TOTAL
Cable Grommet Plate
AAP Frame Plate
Cable Cubby 700
Tweeker
AC Power Module
125V~ 12A MAX TOTAL
and Screws
Retractor Pin & Clip
Cable Grommet Plate
AAP Frame Plate
AC Power Module
125V~ 12A MAX TOTAL
Retractor Pin & Clip
Hole Plugs
Connectivity Bracket
Cable Grommet Plate
AAP Frame Plate
Cable Cubby 500
Cable Cubby 700
Zip Ties
Tweeker
AC Power Module
125V~ 12A MAX TOTAL
“Show Me” Cable Trim Plate
The Cable Cubby units are furniture-mounted enclosures for cable access, connections, and AC power. Cables that are not in use can be stored out of the way while remaining connected to the presentation system.
Planning
Check with local and state regulations before starting the installation:
Ensure that the planned installation complies with building and electrical codes. Ensure that the planned installation complies with the Americans with Disabilities Act or
other accessibility requirements.
Check all parts and equipment before installation:
Ensure that all parts are present in each kit. Ensure that necessary tools and equipment are available for the installation.
Kit Contents
IMPORTANT:
Go to www.extron.com for the
, installation
ews
#6 Mounting Screws
Retractor Trim
and Star Washers
Cable Cubby 500 and Cable Cubby 500 CCB Cable Cubby 700
1 2
4 8
1 2
1 2
1 2
(3) 3/8", (1) 1/4" (6) 3/8", (2) 1/4"
1 trim, 2 screws 2 trims, 4 screws
1 2
4 8
1
Cable Cubby 500 and 700 • Installation Guide (Continued)
Series/2 XL
Cut-Out Template for the Extron
Cable Cubby 500
0.25"
(0.635 cm) R
5.75"
(14.60 cm)
5.75"
(14.60 cm)
2.0"
Trim Rings Outer Edge
(Do not cut this line.)
Table Clamp
P/N 68-8599-01 Rev. A
SURFACE
CUT-OUT
AREA
1. Confirm the product to be installed.
2. Remove the surface cut-out area
(gray) from the template.
3. Measure the cutout and template .
4. Mark the position on the
furniture where the Cable Cubby 500
will be installed.
5. Double check dimensions and position,
then cut the opening.
Page Size: 11" x 17" Print Scale 1:1
Do not Shrink
CutO
C
Cab
Preparing the Table
Cut a hole in the surface where the enclosure will be installed. Read the following information before making a cut.
Determine the best location for the enclosure.
Ensure that the location where the Cable Cubby is to be installed is convenient for as many users as possible. Ensure that the edge on which the lid opens is oriented correctly. Ensure that there is ample space under the table for cables. When installing Retractors in the Cable Cubby, ensure that there is enough space for the Retractor assembly under the table
or furniture (see dimensions for the Retractors below).
NOTES:
To prevent objects from impeding cable retraction, allow at least 3 inches of clearance from the exposed cable side of
the enclosure (see the diagrams below).
Excess cabling may cause clearance issues. Use zip ties to secure under-table cabling to prevent accidental contact or
entanglement (see Routing and Connecting Cables on page 6).
Table Top
9.0"
(22.9 cm)
(7.6 cm)
3.0"
Series/2
15.2"
(38.6 cm)
21.2"
(53.8 cm)
23.3"
(59.2 cm)
8.8"
(22.4 cm)
21.7"
(55.0 cm)
29.3"
(74.4 cm)
11.8"
(30.0 cm)
26.9"
(68.3 cm)
3.0"
(7.6 cm)
Choose a method for cutting the hole in the table.
ATTENTION: The opening in the table for the Cable Cubby should be cut only by licensed and bonded craftspeople.
Exercise care to prevent scarring or damaging the furniture.
ATTENTION : L’ouverture dans la table pour le CableCubby devrait être coupée seulement par des artisans autorisés et
qualiés. Faites attention à ne pas faire de marques sur le meuble et à ne pas l’endommager.
CAUTION: Wear safety glasses when operating power equipment. Failure to comply can result in eye injury.
Series/2 XL
30
Series/2
ATTENTION : Portez des lunettes de sécurité lorsque vous utilisez l’équipement électrique. Ne pas respecter cela peut
conduire à une blessure à l’oeil.
Choose one of the following methods for cutting the hole:
Hand Router and Routing Template Jigsaw and Paper Cut-Out Template CNC Wood Router
Visit www.extron.com for Cable Cubby routing template part numbers and instructions.
2
Jigsaw
Cut-Out Template for the Extron
2.0"
Ta
b le Clamp
Trim Ring
0.25"
Lip Width
+
0.00
0.02 ” (
0.00
(0.0
cm)
5 c
m)
User Access
Trim Ring’s
(Do not c
ut th
Cable Cubby 500
Page Size: 11" x 17" Print Scale 1:1
Do not Shrink
1. Confirm the pr
2. Remove the surface cut-out area
(gray) f
3. M
4. Mark the position on the
furniture where the Cable Cubby 500
easure the cutout and template.
will be installed.
r om the template.
5. Double check oduct to be installed.
then cut the opening.
dimensions and position,
Outer Edge is line.)
P/N
68-859
9-01 Rev. A
Dimensions and cut-out templates are available online at www.extron.com.
If using a CNC wood router or other precise machinery, use the exact cut-out dimensions for your model (see the table below).
Cable Cubby Model
500 5.75" (14.6 cm) 5.75" (14.6 cm)
700 7.125" (18.1 cm) 5.75" (14.6 cm)
500 CCB 5.75” (14.6 cm) 7.125” (18.1 cm)
User Access
30
Cut-out Dimensions
Width
Dimension
Side
Loading...