Extron electronics Cable Cubby 500, Cable Cubby 700, Cable Cubby 500 CCB Installation Manual

Page 1
complete user guide
instructions, and specifications.
Cable Cubby 500 and 700 • Installation Guide
Connectivity Bracket
Cable Grommet Plate
Cable Cubby 700
125V~ 12A MAX TOTAL
Hole Plugs
Connectivity Bracket
Cable Grommet Plate
AAP Frame Plate
Cable Cubby 500
Cable Cubby 700
Zip Ties
Tweeker
AC Power Module
125V~ 12A MAX TOTAL
#6 Mounting Screws
and Star Washers
#4-40 Module Scr
Cable Grommet Plate
AAP Frame Plate
AC Power Module
125V~ 12A MAX TOTAL
Cable Grommet Plate
125V~ 12A MAX
TOTAL
Hole Plugs
Connectivity Bracket
Cable Grommet Plate
Cable Cubby 500
Cable Cubby 700
Zip Ties
125V~ 12A MAX TOTAL
Cable Grommet Plate
AAP Frame Plate
Cable Cubby 700
Tweeker
AC Power Module
125V~ 12A MAX TOTAL
and Screws
Retractor Pin & Clip
Cable Grommet Plate
AAP Frame Plate
AC Power Module
125V~ 12A MAX TOTAL
Retractor Pin & Clip
Hole Plugs
Connectivity Bracket
Cable Grommet Plate
AAP Frame Plate
Cable Cubby 500
Cable Cubby 700
Zip Ties
Tweeker
AC Power Module
125V~ 12A MAX TOTAL
“Show Me” Cable Trim Plate
The Cable Cubby units are furniture-mounted enclosures for cable access, connections, and AC power. Cables that are not in use can be stored out of the way while remaining connected to the presentation system.
Planning
Check with local and state regulations before starting the installation:
Ensure that the planned installation complies with building and electrical codes. Ensure that the planned installation complies with the Americans with Disabilities Act or
other accessibility requirements.
Check all parts and equipment before installation:
Ensure that all parts are present in each kit. Ensure that necessary tools and equipment are available for the installation.
Kit Contents
IMPORTANT:
Go to www.extron.com for the
, installation
ews
#6 Mounting Screws
Retractor Trim
and Star Washers
Cable Cubby 500 and Cable Cubby 500 CCB Cable Cubby 700
1 2
4 8
1 2
1 2
1 2
(3) 3/8", (1) 1/4" (6) 3/8", (2) 1/4"
1 trim, 2 screws 2 trims, 4 screws
1 2
4 8
1
Page 2
Cable Cubby 500 and 700 • Installation Guide (Continued)
Series/2 XL
Cut-Out Template for the Extron
Cable Cubby 500
0.25"
(0.635 cm) R
5.75"
(14.60 cm)
5.75"
(14.60 cm)
2.0"
Trim Rings Outer Edge
(Do not cut this line.)
Table Clamp
P/N 68-8599-01 Rev. A
SURFACE
CUT-OUT
AREA
1. Confirm the product to be installed.
2. Remove the surface cut-out area
(gray) from the template.
3. Measure the cutout and template .
4. Mark the position on the
furniture where the Cable Cubby 500
will be installed.
5. Double check dimensions and position,
then cut the opening.
Page Size: 11" x 17" Print Scale 1:1
Do not Shrink
CutO
C
Cab
Preparing the Table
Cut a hole in the surface where the enclosure will be installed. Read the following information before making a cut.
Determine the best location for the enclosure.
Ensure that the location where the Cable Cubby is to be installed is convenient for as many users as possible. Ensure that the edge on which the lid opens is oriented correctly. Ensure that there is ample space under the table for cables. When installing Retractors in the Cable Cubby, ensure that there is enough space for the Retractor assembly under the table
or furniture (see dimensions for the Retractors below).
NOTES:
To prevent objects from impeding cable retraction, allow at least 3 inches of clearance from the exposed cable side of
the enclosure (see the diagrams below).
Excess cabling may cause clearance issues. Use zip ties to secure under-table cabling to prevent accidental contact or
entanglement (see Routing and Connecting Cables on page 6).
Table Top
9.0"
(22.9 cm)
(7.6 cm)
3.0"
Series/2
15.2"
(38.6 cm)
21.2"
(53.8 cm)
23.3"
(59.2 cm)
8.8"
(22.4 cm)
21.7"
(55.0 cm)
29.3"
(74.4 cm)
11.8"
(30.0 cm)
26.9"
(68.3 cm)
3.0"
(7.6 cm)
Choose a method for cutting the hole in the table.
ATTENTION: The opening in the table for the Cable Cubby should be cut only by licensed and bonded craftspeople.
Exercise care to prevent scarring or damaging the furniture.
ATTENTION : L’ouverture dans la table pour le CableCubby devrait être coupée seulement par des artisans autorisés et
qualiés. Faites attention à ne pas faire de marques sur le meuble et à ne pas l’endommager.
CAUTION: Wear safety glasses when operating power equipment. Failure to comply can result in eye injury.
Series/2 XL
30
Series/2
ATTENTION : Portez des lunettes de sécurité lorsque vous utilisez l’équipement électrique. Ne pas respecter cela peut
conduire à une blessure à l’oeil.
Choose one of the following methods for cutting the hole:
Hand Router and Routing Template Jigsaw and Paper Cut-Out Template CNC Wood Router
Visit www.extron.com for Cable Cubby routing template part numbers and instructions.
2
Jigsaw
Cut-Out Template for the Extron
2.0"
Ta
b le Clamp
Trim Ring
0.25"
Lip Width
+
0.00
0.02 ” (
0.00
(0.0
cm)
5 c
m)
User Access
Trim Ring’s
(Do not c
ut th
Cable Cubby 500
Page Size: 11" x 17" Print Scale 1:1
Do not Shrink
1. Confirm the pr
2. Remove the surface cut-out area
(gray) f
3. M
4. Mark the position on the
furniture where the Cable Cubby 500
easure the cutout and template.
will be installed.
r om the template.
5. Double check oduct to be installed.
then cut the opening.
dimensions and position,
Outer Edge is line.)
P/N
68-859
9-01 Rev. A
Dimensions and cut-out templates are available online at www.extron.com.
If using a CNC wood router or other precise machinery, use the exact cut-out dimensions for your model (see the table below).
Cable Cubby Model
500 5.75" (14.6 cm) 5.75" (14.6 cm)
700 7.125" (18.1 cm) 5.75" (14.6 cm)
500 CCB 5.75” (14.6 cm) 7.125” (18.1 cm)
User Access
30
Cut-out Dimensions
Width
Dimension
Side
Page 3
Connect cables to the AAPs.
e the AAP plate on the
Preparing the Cable Cubby
Secur using the pr mounting scr
mounting screws and
125V~ 12A MAX TOTAL
125V~ 12A MAX TOTAL
Step 1 — Assemble the connectivity modules of your choice.
Connectivity modules allow you to populate the Cable Cubby with a combination of AAPs, cable pass-through modules, or Retractors.
AAP Module
Secur
NOTE: After assembling the
module, proceed to “Step 2 — Install the modules” below.
Secure up to two
1
single-space AAPs in the AAP plate.
#4-40 Nut w/ Captive Washer
Cable Pass-Through Module
NOTE: After assembling the module, proceed to “Step 2 — Install the modules” below.
For Show Me Cables:
Snap the included
3
hole plugs into any unused holes.
Secure the
2
grommet plate on the connectivity bracket using two of the provided module screws.
1
Insert cables through the bottom of the connectivity bracket and into the holes of the grommet plate.
1
Flip grommet plate upside down and insert Show Me Cables into the grommet plate.
2
Attach the Show Me Cable Trim Plate to the top of the module, using the module screws.
3
Attach the grommet plate to the bottom of the module, using the module screws.
3
connectivity brackets, using two of the provided module screws.
Connectivity bracket
Insert cables through the bottom
2
of the connectivity bracket.
Retractor Trim
e the Retractor trim
ovided
ews (2).
NOTE:
Use a screwdriver to secure the Retractor trim with the screws.
After installing the trim, proceed to “Step 2 — Install the
modules” below to install the power module.
Retractors are installed after the Cable Cubby is mounted on the
table (see Installing Retractors on page 5).
Step 2 — Install the modules.
Determine where the connectivity modules and power module will be installed in the Cable Cubby. The modules may be installed at various heights.
NOTE: Ensure that there is enough room above the
modules for the Cable Cubby lid to close completely.
For the power module:
WARNING: Risk of electric shock. To ensure proper
electrical grounding, use at least two of the provided #6-32 mounting screws with the star washers.
AVERTISSEMENT : Risque de choc électrique.
An d’assurer une mise à la terre correcte, utilisez un minimum de deux vis de mise à la terre #6-32 et les rondelles en étoile fournies.
3
For Show Me Cable assemblies, only use the
top holes of the bracket.
Use top hole only.
125V~ 12A MAX TOTAL
2
Secure the modules using the provided
star washers on the front and back of the enclosure.
1
Insert the modules into the Cable Cubby.
Page 4
Connecting a Cable Cubby 500 CCB
Lower the Cable Cubby into the hole to test the t. If necessary, carefully enlarge the opening.
For Cable Cubby 500 CCB models, follow the instructions below, then proceed to “Mounting the Cable Cubby in the Table.”
The Cable Cubby 500 CCB contains three contact closure buttons to control input selection on Extron switchers and products with contact closure control ports. Wire the Cable Cubby switches to the control product as shown in the wiring diagram below.
To wire the captive screw connectors:
1. Strip away 3 inches of the outer jacket
from the end of the cable, and 3/16 inch (5 mm) of the inner jacket from the end of each wire.
2. Secure the wires to the captive screw
connector using an Extron Tweeker or other small screwdriver. Follow the wiring diagram at the right.
Momentary switch
(single pole, double throw)
on captive screw terminal
Contact (C) Ground (G) Tally output (T) Tally voltage (+V)
CNONC
Extron Switcher with
Contact Closure Input
and Tally Output
CGT+V
RESISTOR
NOTE: See the table at the right to
determine and select the appropriate current-limiting resistor, if needed.
Mounting the Cable Cubby in the Table
Step 1 — Mount the Cable Cubby flush with the table.
Remove the plastic strips
1
and lm on the surface of the Cable Cubby.
Ensure that the
2
side clamps are seated against the enclosure.
1A @ 24 VDC / 125 VAC
NOTE: No resistor required for 5 VDC source.
Blue
See note below
4.52 K, 1%
13 K, 1%
CAUTION: The anged edges of the top of the
surface enclosure are sharp. These edges are also soft and may be easily nicked or bent. Exercise caution when handling the enclosure to prevent personal injury or damage to the enclosure.
ATTENTION : Les extrémités à brides du haut de la
surface du boîtier sont aiguisées. Ces extrémités sont aussi lisses et peuvent facilement être coupées ou pliées. Soyez prudents lorsque vous manipulez le boîtier an d’éviter de l’endommager ou de vous blesser.
4
3
Page 5
Cable Cubby 500 and 700 • Installation Guide (Continued)
Remove two enclosure screws (one on each side) from this position. Then, mount the Retractors as shown at left.
Cable Release Assembly
Reinstall the
e the clip
Insert the pin thr r the side of the Cable Cubby and r
Step 2 — Under the table, adjust the side clamps on the enclosure.
NOTE: To lower the side
clamp, turn the lever down, then press and hold the locking plate
1
while sliding down the clamp.
Lever
1
Installing Retractors
Follow the steps below to install Retractors. For horizontal or angular Retractor mounting, see the information at right, then follow the steps below.
2
etractor mounting hole on
etractor assembly.
Rotate the side clamp outward and ensure that the lever is down.
Insert retractors into
1
the retractor trim.
ough the
Slide the clamp all the way
2 3
up against the bottom of the table.
Secur
3
on the pin.
4
Secure the locking screw on each Retractor.
Do not overtighten. The locking screw only needs to be snug.
Ensure the Cable Cubby is rmly seated in the table. Raise the lever to secure the Cable Cubby.
See the Cable Retractor Setup Guide, available on the
Remove the enclosure screws as shown above, then follow this step:
Locking plate
Horizontal Mounting
Cable Release Assembly
Remove two enclosure screws (one on each side) from this position. Then, mount the Retractors as shown at left.
Extron website, for additional steps.
Angular Mounting
Move the cable release assembly upward until the angular mounting hole is visible. enclosure screws in this hole (both sides).
5
Page 6
Routing and Connecting Cables
ough applications, allow at least 36 inches (0.9 m)
2
1
For cable pass-thr of cable loop for each cable.
CAUTION:
Risk of Electric Shock.
This equipment must be grounded.
ATTENTION :
Risque de choc électrique.
Connect cables to the AV system
3
and connect the AC power cord.
Cet équipement doit être xé au sol.
NOTE: Ensure that there is no tension on the power cable.
Secure cables with zip ties to the rectangular holes in the rear of the Cable Cubby.
Installation Checklist
Planning (page 1)
Check with local and state regulations before starting the installation.
Check all parts and equipment before installation.
Preparing the Table (page 2)
Determine the best location for the enclosure.
Choose a method for cutting the hole in the table.
Preparing the Cable Cubby (page 3)
Choose and assemble a combination of AAP, cable-pass through, and Retractor connectivity to populate
the Cable Cubby.
Secure the connectivity modules and power module in the Cable Cubby.
Connecting a Cable Cubby 500 CCB (page 4)
Mounting the Cable Cubby in the Table (page 4)
Mount the Cable Cubby ush with the table.
Adjust the side clamps.
Installing Retractors (page 5)
Routing and Connecting Cables (page 6)
Extron Headquarters
+800.633.9876 Inside USA/Canada Only
Extron USA - West Extron USA - East
+1.714.491.1500 +1.919.850.1000
+1.714.491.1517 FAX +1.919.850.1001 FAX
Extron Europe
+800.3987.6673
Inside Europe Only
+31.33.453.4040
+31.33.453.4050 FAX
© 2017 Extron Electronics All rights reserved. All trademarks mentioned are the property of their respective owners. www.extron.com
6
Extron Asia
+65.6383.4400
+65.6383.4664 FAX
Extron Japan
+81.3.3511.7655
+81.3.3511.7656 FAX
Extron China
+86.21.3760.1568
+86.21.3760.1566 FAX
Extron Middle East
+971.4.299.1800
+971.4.299.1880 FAX
Extron Australia
+61.8.8113.6800 +61.8.8351.2511 FAX
68-2491-50
Rev. G
Extron India
1800.3070.3777
(Inside India Only)
+91.80.3055.3777
+91.80.3055.3737 FAX
08 17
Loading...