Cable Cubby 202 • Installation Guide
Retainer Clip
Screws (US model only)
This guide provides instructions for an experienced installer to install and connect the Extron Cable Cubby 202 Cable Access Enclosures.
Planning
Check with local and state regulations before starting the installation:
Ensure that the planned installation complies with building and
electrical codes.
Ensure that the planned installation complies with the Americans with Disabilities
Act or other accessibility requirements.
Check all parts and equipment before installation:
Ensure that all parts are present in each kit. Ensure that necessary tools and equipment are available for the installation.
IMPORTANT:
Go to www.extron.com for the
complete user guide, installation
instructions, and specifications.
CABLE CUBBY
Kit Contents
Grommet Plugs (3) 3/8", (1) 1/4"
AC Cord (Non-US models only)
Cable Cubby 202
Cable Grommet Plate
and #4-40 Plate Screws
Mini AAP and #4-40 Mounting
Preparing the Table
Cut a hole in the surface where the enclosure will be installed. Read the following information before making a cut.
Determine the best location for the enclosure
Ensure that the location where the Cable Cubby is to be installed is convenient for as many users as possible. Ensure that the edge on which the lid opens is oriented correctly. Ensure that there is ample space under the table for cables.
Choose a method for cutting the hole in the table
See the next page for details on cutting the hole in the table.
1
Page 2
Cable Cubby 202 • Installation Guide (Continued)
opening by the AC connection.
Cut-Out T
Cab
Cut-Out Template for the Extron
Cable Cubby 202
User Access
0.00 (0.00 cm)
0.02 (0.05 cm)
+
Outer Edge of Front Bezel (Do not cut this line.)
1. Confirm the product to be installed.
2. Remove the surface cut-out area
(gray) from the template.
3. Measure the cutout and template.
4. Mark the position on the
furniture where the Cable Cubby 202
will be installed.
5. Double check dimensions and position,
then cut the opening.
P/N ??-????-01 Rev. A
Page size: 11" x 17" Print scale 1:1
Do not shrink.
3.25"
(8.25 cm)
7.0"
(17.78 cm)
SURFACE CUT-OUT AREA
Cut-Out Radi
u s:
0.25" (
0.6 cm)
Cut-Out T
Cab
Choose one of the following methods for cutting the hole:
Hand Router and Routing Template Jigsaw and Paper Cut-Out Template CNC Wood Router
Cut-Out Template for the Extron
Cable Cubby 202
3.25"
(8.25 cm)
(17.78 cm)
User Access
CUT-OUT AREA
SURFACE
7.0"
Outer Edge of Front Bezel (Do not cut this line.)
P/N ??-????-01 Rev. A
(gray) from the template.
3. Measure the cutout and template.
4. Mark the position on the
furniture where the Cable Cubby 202
will be installed.
5. Double check dimensions and position,
then cut the opening.
+
0.00” (0.00 cm)
0.02 (0.05 cm)
1. Confirm the product to be installed.
2. Remove the surface cut-out area
Page size: 11" x 17" Print scale 1:1
Do not shrink.
Cut-Out Radi
0.25" (0.6 cm)
u s:
Visit www.extron.com for Cable Cubby routing template part numbers and
Dimensions and cut-out templates are available online at www.extron.com.
instructions.
The opening in the table for the Cable Cubby should be cut only by licensed and bonded craftspeople.
CAUTION: Wear safety glasses when operating power equipment. Failure to comply can result in eye injury.
ATTENTION: Portez des lunettes de sécurité lorsque vous utilisez l’équipement électrique. Ne pas respecter cela peut
conduire à une blessure à l’oeil.
If using a CNC wood router or other precise machinery, use the exact cut-out dimensions (see the table below).
Cut-out Dimensions
User Access
Side Dimension
Width
7.0"
(17.8 cm)
3.25"
(8.3 cm)
Preparing the Cable Cubby
Assemble the cable pass-through plate and (for US models) install a Mini AAP.
1
Assemble the cable pass-through plate with your choice of AV cables.
Snap the included hole plugs into any unused holes.
Insert the assembled plate into the
2
enclosure and secure the plate, using the included plate screws.
3
US models only:
Install a Mini AAP into the
Connect AV cables to the Mini AAP if necessary, and secure the plate using the provided plate screws.
2
Page 3
Mounting and Installing the Cable Cubby in the Table
Remove the plastic strips and lm on the
En
se
Lower the Cable Cubby into the hole to test the t. If necessary, carefully enlarge the opening.
Remove the plastic strips and lm on the surface of the Cable Cubby.
Ensure that the side clamps are seated against the enclosure.
En
se
1
2
3
CAUTION: The anged edges of the top of the surface enclosure are sharp. These edges are also soft and may be easily
nicked or bent. Exercise caution when handling the enclosure to prevent personal injury or damage to the enclosure.
ATTENTION: Les extrémités à brides du haut de la surface du boîtier sont aiguisées. Ces extrémités sont aussi lisses
et peuvent facilement être coupées ou pliées. Soyez prudents lorsque vous manipulez le boîtier an d’éviter de l’endommager ou de vous blesser.
1
surface of the Cable Cubby.
Ensure that the side clamps are
2
seated against the enclosure.
3
Lower the Cable Cubby into the hole to test the t. If necessary, carefully enlarge the opening.
Ensure that the Cable Cubby is rmly seated in the table.
4
Using a screw driver or drill, turn the clamp screw clockwise and slowly tighten it to secure the enclosure to the surface.
ATTENTION: Do not overtighten the Phillips head screws on the
screw clamps. Overtightening can bend the horizontal ange of the screw clamp.
ATTENTION: Ne serrez pas trop les vis à tête Phillips sur les pinces à
visser. Le fait de trop serrer peut faire se plier la xation horizontale de la pince à vis.
3
Page 4
Routing and Connecting Cables
system
Use zip ties to secu cables to the r holes in r Cubb
1
re
ectangular
ear of Cable
y.
Connect cables to the AV
2
and connect the AC power cord.
CAUTION:
Risk of Electric Shock.
NOTE:
For cable pass-through
applications, allow at least 36 inches (0.9 m) of cable loop for each cable.
Ensure that there is no
tension on the power cable.
This equipment must be grounded.
ATTENTION:
Risque de choc électrique.
Cet équipement doit être xé au sol.
Cable Retainer for Non-US Models
For non-US models, secure the power cable with the included cable retainer as shown below.
2
1
Installation Checklist
Planning (page 1)
Check with local and state regulations before starting the installation.
Check all parts and equipment before installation.
Preparing the Table (pages 1 and 2)
Determine the best location for the enclosure.
Choose a method for cutting the hole in the table.
Preparing the Cable Cubby (page 2)
Assemble the cable pass-through plate and (for US models) install a Mini AAP.
Mounting and Installing the Cable Cubby in the Table (page 3)
Routing and Connecting Cables (page 4)
Extron Headquarters
+800.633.9876 Inside USA/Canada Only
Extron USA - West Extron USA - East
+1.714.491.1500 +1.919.850.1000
+1.714.491.1517 FAX +1.919.850.1001 FAX
© 2014 Extron Electronics All rights reserved. All trademarks mentioned are the property of their respective owners. www.extron.com
4
Extron Europe
+800.3987.6673
Inside Europe Only
+31.33.453.4040
+31.33.453.4050 FAX
Extron Asia
+65.6383.4400
+65.6383.4664 FAX
Extron Japan
+81.3.3511.7655
+81.3.3511.7656 FAX
Extron China
+86.21.3760.1568
+86.21.3760.1566 FAX
Extron Middle East
+971.4.299.1800
+971.4.299.1880 FAX
Extron Korea
+82.2.3444.1571
+82.2.3444.1575 FAX
68-2486-01
Rev. A
04 14
Extron India
1800.3070.3777
(Inside India Only)
+91.80.3055.3777
+91.80.3055.3737 FAX
Loading...