IMPORTANT:
instructions, and specifications.
Cable Cubby 1202
Cable Cubby 1402
Go to www.extron.com for the
Cable Cubby 1202 and 1402 • Installation Guide
This guide provides instructions for an experienced technician to install and connect the
Extron Cable Cubby 1202 and 1402.
The Cable Cubby units are furniture-mounted enclosures for cable access, connections,
and AC power. Cables that are not in use can be stored out of the way while
remaining connected to the presentation system.
NOTE: This product is intended for use only with Extron UL listed
power modules (not included).
Planning
Check with local and state regulations before starting the
installation
Ensure that the planned installation complies with national and local building and electrical codes.
Ensure that the planned installation complies with the Americans with Disabilities Act or other accessibility requirements.
Check all parts and equipment before installation
Ensure that all parts are present in each kit.
Ensure that necessary tools and equipment are available for the installation.
, installation
Kit Contents
Connectivity
Bracket
#4-40 Module Screws
AAP Frame Plate
Cable Grommet
Plate
Hole Plugs
Retractor
Bracket
1 2
4 8
1 2
1 2
6 (3/8"), 2 (1/4") 12 (3/8"), 4 (1/4")
1 2
Retractor
Pin & Clip
#6 Pan-head
Mounting Screws
and Star Washers
1 2
8 16
1

Cable Cubby 1202 and 1402 • Installation Guide (Continued)
Connect cables to the AAPs.
Preparing the Table
Cut a hole in the surface where the enclosure will be installed. Read the following information before making a cut.
Determine the best location for the enclosure
Ensure that the location where the Cable Cubby is to be installed is convenient for as many users as possible.
Ensure that the edge on which the lid opens is oriented correctly.
Ensure that there is ample space under the table for cables. Allow at least 36 inches of cable loop for each cable (see
Routing and Connecting Cables on page 6).
When installing Retractors in the Cable Cubby, ensure that there is enough space for the Retractor assembly under the table
or furniture (see the Cable Retractor Series/2 Installation Guide for Retractor dimensions).
Choose a method for cutting the hole in the table
CAUTION: Wear safety glasses when operating power equipment. Failure to comply can result in eye injury.
ATTENTION : Portez des lunettes de sécurité lorsque vous utilisez l’équipement électrique. Ne pas respecter cela peut
conduire à une blessure à l’oeil.
ATTENTION: The opening in the table for the Cable Cubby should be cut only by licensed and bonded craftspeople.
Exercise care to prevent scarring or damaging the furniture.
ATTENTION : L’ouverture dans la table pour le CableCubby devrait être coupée seulement par des artisans autorisés et
qualiés. Faites attention à ne pas faire de marques sur le meuble et à ne pas l’endommager.
Choose one of the following methods for cutting the hole:
Hand Router and Routing Template Jigsaw and Paper Cut-Out Template CNC Wood Router
If using a CNC wood router or other
precise machinery, use the exact
cut-out dimensions for your model
(see the table below).
Cut-Out Template for the Extron
Cut-Out Radius:
0.25" (0.6 cm)
User Access
Cable Cubby 1200
Trim Ring
Lip
Outer Edge of Front Bezel
(Do not cut this line.)
P/N 68-2472-01 Rev. A
1. Confirm the product to be installed.
2. Remove the surface cut-out area
(gray) from the template.
3. Measure the cutout and template .
4. Mark the position on the
furniture where the Cable Cubby 1200
will be installed.
5. Double check the dimensions and position,
then cut the opening.
Page Size: 11" x 17"
Print Scale 1:1
Do not Shrink
Cut-out Dimensions
Product
User Access
Width
CC 1202 10.00"
(254.0 mm)
Visit www.extron.com for Cable Cubby routing
template part numbers and instructions.
Dimensions and cut-out templates are
available online at www.extron.com.
CC 1402 10.00"
(254.0 mm)
Preparing the Cable Cubby
Step 1 — Assemble Connectivity Modules
Connectivity modules allow you to populate the Cable Cubby enclosure with a combination of AAPs, cable pass-through, or
Retractors. Follow the steps below to assemble the connectivity modules of your choice.
Option 1: AAP Module
Side
Dimension
4.00"
(101.6 mm)
6.75"
(171.5 mm)
Secure up to three single-space
1
AAPs in the AAP plate.
#4-40 Nut with
Captive Washer
ce
NOTE: After assembling the module, proceed to Step 2 — Install the Modules on page 4.
2
3
3
Insert cables through the bottom of the connectivity bracket.
2
Secure the AAP plate on the connectivity brackets,
ecu
sin
using four of the provided module screws.