Extron Electronics Basic 1U Rack Shelf User Manual

User’s Guide
Part Numbers
Included parts
Part Part #
Universal 1U rack shelf 60-190-01
Half rack false front panel, gray 70-339-01 Quarter rack false front panel, gray 70-338-01 Eighth rack false front panel, gray 70-337-01 16 4-40 x 3/16" screws 4 6-32 x 1/8" screws 4 10-32 x 3/4" black screws
Basic 1U rack shelf 60-604-01
16 4-40 x 3/16" screws 4 6-32 x 1/8" screws 4 10-32 x 3/4" black screws
Additional faceplates
Part Part #
Half rack false front panel, gray 70-339-01 Half rack false front panel, black anodized 70-339-02 Quarter rack false front panel, gray 70-338-01 Quarter rack false front panel, black anodized 70-338-02 Eighth rack false front panel, gray 70-337-01 Eighth rack false front panel, black anodized 70-337-02
Extron Electronics, USA
1230 South Lewis Street Anaheim, CA 92805 USA
www.extron.com
714.491.1500 Fax 714.491.1517
Beeldschermweg 6C 3821 AH Amersfoort The Netherlands +31.33.453.4040 Fax +31.33.453.4050
© 2005 Extron Electronics. All rights reserved.
Extron Electronics, Asia
135 Joo Seng Road, #04-01 PM Industrial Building Singapore 368363 +65.6383.4400 Fax +65.6383.4664
Extron Electronics, Japan
Kyodo Building 16 Ichibancho Chiyoda-ku, Tokyo 102-0082 Japan +81.3.3511.7655 Fax +81.3.3511.7656
Universal 1U Rack Shelf
Basic 1U Rack Shelf
Installation
68-195-01 Rev. F
03 05
Installation
Installation
About the 1U Rack Shelves
The Basic 1U Rack Shelf ships with the following:
• 1 black anodized 1U rack shelf
• 16 4-40 x 3/16" screws for mounting most devices onto the shelf
• 4 6-32 x 1/8" screws for mounting INxxxx devices onto the shelf
• 4 10-32 x 3/4" black screws with captive washers for mounting the shelf in a rack
The Universal 1U Rack Shelf (figure 1) ships with all of the basic rack shelf’s equipment plus the following:
• 1 textured, charcoal gray, 1U rack shelf
• 16 4-40 x 3/16" screws for mounting most devices onto the shelf
• 4 6-32 x 1/8" screws for mounting INxxxx and TPR101 devices onto the shelf
• 4 10-32 x 3/4" black screws with captive washers for mounting the shelf in a rack
• 1 charcoal gray half rack width false front panel
• 1 charcoal gray quarter rack width false front panel (not shown)
• 1 charcoal gray eighth rack width false front panel (not shown)
1.75" (4.45 cm)
17.375" (44.13 cm)
19" (48.26 cm)
Before installing the 1U Rack Shelf, consider the available space in the rack, and the device(s) that will be mounted on this shelf.
A 1U shelf rack can accommodate the following (figure 2):
• 2 half rack width devices
• 3 one-third rack width devices
• 4 standard quarter rack width devices
• 7 VersaTools® quarter rack width devices (leave one rear mounting location empty for cable routing)
• 15 VersaTools eighth rack width devices (leave one rear mounting location empty for cable routing)
• A mix of devices in different widths and depths
D
IS
T
R
IB
U
T
IO
N
A
M
P
L
IF
IE
R
MDA SERIES
DISTRIBUTION
AMPL
IFIER
Figure 1 — 1U rack shelf
1U Rack Shelf • Installation
1
9" (22.86 cm)
Figure 2 — Half rack, quarter rack VersaTools, and eighth rack VersaTools devices on a 1U rack shelf
Installing the Device(s)
All the rack-mountable devices have two threaded holes in their base plate for mounting onto the shelf.
It is easier to first install the device(s) onto the 1U shelf and then install the shelf in the rack.
The standard half rack width products and INxxxx and TPR101 half rack width products mount in one of two locations in the front of the rack.
The one-third rack width products mount in one of three locations in the front of the rack.
21U Rack Shelf • Installation1
Installation
Installation
The standard quarter rack width products mount in one of four locations in the front of the rack.
The quarter rack VersaTools products mount in one of eight locations in the front or rear of the rack.
The eighth rack VersaTools products mount in one of eight locations to the rear of the rack or in one of eight locations to the front of the rack.
1. If the device being installed has rubber feet, remove them.
2. Place the device on the shelf so that its two threaded holes line up
with two holes in the 1U shelf. Use two 4-40 x 3/16" screws or two 6-32 x 1/8" screws to secure the device onto the shelf (figure 3).
Use 6-32 x 1/8" screws for all INxxxx and TPR101 one-third rack width products.
Use 4-40 x 3/16" screws for all other products.
Installing INxxxx half rack products on this shelf leaves a small (1/8" [0.3 cm]) gap on either side of the installed product. This is normal.
A combination of faceplates can fill gaps that are caused by mixing half rack width, quarter rack width, and eighth rack width products. There is no combination of faceplates that can fill the gaps created when you are installing one-third rack width products.
One of each faceplate, in the charcoal gray finish, is included with the universal rack shelf. All faceplates, in either finish, are available as accessories. See Part Numbers, on the rear of this User’s Guide.
Installing the Shelf in a Rack
1. Use the four 10-32 x 3/4" black screws with captive washers to mount the 1U shelf in the rack (figure 4).
#10-32 Screw w/ Nylon Captive Cap Washer
False front panel
uses 2 front holes.
Use 2 mounting holes
on opposite corners.
Figure 3 — Mounting the device to a rack
3. If additional devices are being installed, follow steps 1 and 2 to mount the devices on other portions of the shelf.
4. If there is a large gap in the front of the panel, install the half rack width, quarter rack width, and/or eighth rack width false faceplate(s) onto the unused area of the shelf using two 4-40 x 3/16" screws.
1U Rack Shelf • Installation
Figure 4 — Mounting the shelf in a rack
2. When the shelf is mounted, continue the installation by connecting the input, output, and power cables.
1U Rack Shelf • Installation