Cable Cubby Series/2 • Installation Guide
The AC100, AC + USB200, and AC + USB 300 Power Modules feature powered sockets for powering and charging compatible
mobile devices. Some models may have an external power supply. Where applicable, follow the steps to install and secure the
power module to, but not limited to, a Cable Cubby enclosure (see the ATTENTION below before installing the power module).
NOTE: To view the power specifications pertaining to these products, see www.extron.com.
In models with external power
1
supplies, secure the AC
and external power supply
cords with the included
USB CHARGER
Top View
AC+USB 200 EU
cable retainers (2).
Cable Retainer
AC Power Cord for
Power Supply
Cable Retainer
External Power
Supply
AC Power Cord for
Power Module
Insert the modules
2
into the Cable Cubby.
AC 100 US
Secure the modules
3
using four of the provided
pan-head mounting scr
and star washers.
and
Bottom View
AC+USB 200 EU
WARNING: To ensure proper electrical grounding, use the provided #6-32 grounding screws and star washers.
AVERTISSEMENT : An d’assurer une mise à la terre correcte, utilisez les xations de mise à la terre #6-32 et les rondelles en
étoile fournies.
ATTENTION:
• In models with external power supplies, always use a power supply provided by or specied by Extron. Use of an
unauthorized power supply voids all regulatory compliance certication and may cause damage to the supply and the
end product.
• Utilisez toujours une source d’alimentation fournie ou recommandée par Extron. L’utilisation d’une source d’alimentation
non autorisée annule toute conformité réglementaire et peut endommager la source d’alimentation ainsi que le produit
nal.
• Always consult with a professional installer.
• Toujours consulter un installateur professionnel.
• Unless otherwise stated, the AC/DC adapters are not suitable for use in air handling spaces or in wall cavities. The
external power supply that is included in selected models is to be located within the same vicinity as the Extron AV
processing equipment in an ordinary location, Pollution Degree 2, secured to the equipment rack within the dedicated
closet, podium, or desk.
• Sauf mention contraire, les adaptateurs CA/CC ne conviennent pas à une utilisation dans les espaces d’aération ou dans
les cavités murales. La source d’alimentation doit être placée à proximité de l’équipement Extron dans un emplacement
ordinaire soumis à un degré de pollution de catégorie II, solidement xé au rack d’équipement d’une baie technique,
d’un pupitre, ou d’un bureau.
• Follow all national and local building and electrical codes that apply to the installation site.
• Respectez tous les codes électriques et du bâtiment, nationaux et locaux, qui s’appliquent au site de l’installation.
1

ATTENTION:
From Conduit Power Module Series
To 15 Amp
• The installation must always be in accordance with the applicable provisions of National Electrical Code ANSI/NFPA
70, article 725 and the Canadian Electrical Code part 1, section 16. The power supply shall not be permanently xed to
building structure or similar structure.
• Cette installation doit toujours être conforme aux dispositions applicables du Code américain de l’électricité (National
Electrical Code) ANSI/NFPA 70, article 725, et du Code canadien de l’électricité, partie 1, section 16. La source
d’alimentation ne devra pas être xée de façon permanente à une structure de bâtiment ou à une structure similaire.
• Do not cut off the ground pin from the power cord plug.
• Ne pas couper la broche de mise à la terre de la che du cordon d’alimentation.
AC 100, AC + USB 200, and AC + USB 300 Conduit Power Module Series
The AC 100, AC+USB 200, and AC+USB 300 Conduit Power Module Series feature a exible metal conduit attached to the power
module. Run the unattached end of this power module to a UL listed junction box and wire it as shown below.
NOTE: Extron recommends that the circuit be attached to a UL listed junction box that is wired directly to the main circuit.
The AC power module does not have a fuse and is rated at 15 A maximum.
WARNING:
AVERTISSEMENT :
• Switch off all electrical power before connecting the AC conduit to a junction box, and keep power off until installation is
complete.
• Débranchez toutes les sources d’alimentation électrique avant de connecter le conduit d’alimentation à un boîtier
d’encastrement, et gardez l’alimentation éteinte jusqu’à ce que l’installation soit complète.
• All structural steps and electrical installation must be performed by qualied personnel in accordance with local and
national building codes and electrical codes.
• Toute étape structurelle et installation électrique doit être effectuée par un personnel qualié, conformément aux codes
de sécurité de bâtiments et de produits électriques en vigueur à l’échelle régionale et nationale.
x
Main Circuit
Conduit
2
AC Conduit
Twist together the neutral wire from the
1
conduit with the white (neutral) wire
from the power module.
Twist together the hot wire from the
conduit with the black (hot) wire from
the power module.
3
Connect the green (ground) wire from the power module
to the ground terminal on the junction box.
NOTE: For steps 1 and 2, twist a wire nut or other
appropriate splicing connector (not provided) onto
each twisted pair. Use tie wraps if necessary.