Extron Electronics AAP 100 MD User Manual

User’s Guide
AAP 100 MD
MD Floor Box AAP Bracket Installation Kit
68-720-01 Rev. B
11 08
Installation
3. Remove Screws
4. Slide
5. Remove Screws
Introduction
This guide covers installation of the Extron MD Floor Box AAP Bracket Kit in a Matsushita Denko (MD) floor box. It shows removal of the old bracket and installation of the new bracket/AAP unit.
Installation
C
1. Turn off and disconnect power from all
2. Remove all cables connected
3. Open the lid and remove
4. Remove the lid from
Installation and service must be performed by
authorized personnel only.
equipment connected to the floor box.
to the portion of the floor box accessible when the lid is open (if applicable).
the two screws securing the lid to the floor box.
the floor box by sliding the lid toward the hinge to disengage it from the box, then put the lid aside.
MD Floor Box AAP Kit • Installation
N
5. Remove the two screws securing the old adapter plate
6. Slide the adapter plate bracket to the center of the box
7. Remove the old adapter plate bracket and adapter plate
If there is no adapter plate or blank plate installed, skip to
step 8.
bracket to the box.
and disconnect the cables attached to the back side of the adapter plate.
unit from the floor box.
10. Slide Bracket
11. Attach with
M4 Screws
8. Attach and secure any single or double Extron AAP (for example, the double AAP shown below) to the MD AAP bracket with the 4‑40 mounting nuts provided.
9. Connect cables, if applicable, to the back of the AAP to be installed.
10. Place the MD AAP bracket into the floor box (as shown
11. Align the two screw holes in the top of the new AAP
above), routing any cables through the back of the box and slide it in the direction shown.
bracket with the holes in the box. Attach the bracket with the two M4 screws provided.
MD Floor Box AAP Kit • Installation
Extron USA - West
Headquarters
+800.633.9876
Inside USA / Canada Only
+1.714.491.1500 +1.714.491.1517 FAX
Extron USA - East
+800.633.9876
Inside USA / Canada Only
+1.919.863.1794 +1.919.863.1797 FAX
Extron EMEA
+800.3987.6673
Inside Europe Only
+31.33.453.4040 +31.33.453.4050 FA X
Extron Asia
+800.7339.8766
Inside Asia Only
+65.6383.4400 +65.6383.4664 FAX
Extron Japan
+81.3.3511.7655 +81.3.3511.7656 FAX
Extron China
+400.883.1568
Inside China Only
+86.21.3760.1568 +86.21.3760.1566 FAX
Extron Middle East
+971.4.2991800 +971.4.2991880 FAX
Installation, cont'd
13. Replace Screws
12. Slide
12. Place the lid on the floor box and slide it away from the hinge to engage the tabs on the box.
13. Reinstall the two previously removed screws, securing the lid to the box.
14. Reconnect power and cables, as necessary.
Optional Extron Architectural Adapter Plates
A variety of optional architectural adapter plates for pass‑through connections may be ordered for the MD floor box AAP bracket. Visit the Extron website at www.extron.com for additional information.
The AAP bracket can have up to two architectural adapter plates installed, depending on the configuration selected.
The following configurations of architectural adapter plates could be installed in the MD floor box adapter plate:
• two single spaced AAPs
• one double spaced AAP
© 2008 Extron Electronics. All rights reserved.
Loading...