Extron electronics 650 UT Installation Manual

Page 1
IMPORTANT:
complete user guide
instructions, and specifications.
125V~ 12A MAX TOTAL
Go to www.extron.com for the
Cable Cubby 650 UT • Installation Guide
The Cable Cubby 650 UT units are under furniture mountable and are expandable for cable access, connections, and AC power.
Planning
Check with local and state regulations before starting the installation
Ensure that the planned installation complies with building and electrical codes. Ensure that the planned installation complies with the Americans with Disabilities Act or other accessibility requirements.
Check all parts and equipment before installation
Ensure that all parts are present in each kit. Ensure that necessary tools and equipment are available for the installation. Determine the number for Cable Cubby 650 UT enclosures you intend to install.
, installation
Kit Contents
Connectivity Bracket
#4-40 Module Screws
AAP Frame Plate
Cable Grommet Plate
Hole Plugs
Cable Cubby 650 UT
1
4
1
1
(6) 3/8", (2) 1/4"
Retractor Bracket
Retractor Pin and Clip
#6 Pan-head Mounting Screws and Star Washers
1
1
4
1
Page 2
Cable Cubby 650 UT • Installation Guide (Continued)
Preparing the Table
(672 mm)
(229 mm
Cut a hole in the surface where the enclosure will be installed. The size of the hole depends on the number of enclosures used (see cut-out dimensions on the next page). Ensure the sides of the hole are smooth after cutting and finished before installing. Read the following information before making a cut.
Determine the best location for the enclosure
Ensure that the location where the Cable Cubby is to be installed is convenient for as many users as possible. Ensure that there is ample space under the table for cables. Allow at least 36 inches of cable loop for each cable (see Routing
and Connecting Cables on page 7).
When installing Retractors in the Cable Cubby, ensure that there is enough space for the Retractor assembly under the table
or furniture.
NOTES:
To prevent objects from impeding cable retraction, allow at least 3 inches of clearance from the exposed cable side of
the enclosure (see the diagrams below).
Excess cabling may cause clearance issues. Use zip ties to secure under-table cabling to prevent accidental contact or
entanglement (see Routing and Connecting Cables on page 7).
Table Top
9.0"
15.14"
)
(385 mm)
9.23"
(234 mm)
12.23"
(311 mm)
3.0"
(76 mm)
3.0"
(76 mm)
Series/2
Series/2 XL
21.14"
(537 mm)
22.95"
(583 mm)
Series/2
21.28"
(540 mm)
28.95"
(735 mm)
30
30
Series/2 XL
26.47"
2
Page 3
Cut the hole in the table and pre-drill mounting holes
CAUTION: Wear safety glasses when operating power equipment. Failure to comply can result in eye injury.
ATTENTION : Portez des lunettes de sécurité lorsque vous utilisez l’équipement électrique. Ne pas respecter cela peut
conduire à une blessure à l’oeil.
ATTENTION: The opening in the table for the Cable Cubby should be cut only by licensed and bonded craftspeople.
Exercise care to prevent scarring or damaging the furniture.
ATTENTION : L’ouverture dans la table pour le CableCubby devrait être coupée seulement par des artisans autorisés et
qualiés. Faites attention à ne pas faire de marques sur le meuble et à ne pas l’endommager.
For one or two enclosures, the cut-out dimensions and mounting hole locations are shown below. For more enclosures, multiply the length accordingly. If necessary, pre-drill into the furniture at the keyhole and mounting hole locations.
7"
(178 mm)
6.5"
(165 mm)
6"
(152 mm)
3"
(76 mm)
4 1/4"
(108 mm)
1.5"
(38 mm)
SURFACE
CUT-OUT
(38 mm)
5"
(127 mm)
AREA
1
+
/16" (1.5 mm)
-
1.5"
6.5"
(165 mm)
1.5"
(38 mm)
(254 mm)
10"
6.5"
(165 mm)
6"
(152 mm)
(76 mm)
1.5"
(38 mm)
1
4
/
"
3"
4
(108 mm)
NOTE: Diagrams shown above are not drawn to scale.
Keyholes (2)
(305 mm)
2.0"
(51 mm)
11.5"
(292 mm)
Mounting Holes (8)
12"
SURFACE
CUT-OUT
AREA
1
+
/16" (1.5 mm)
-
Keyholes (4)
Mounting Holes (16)
Dimensions and cut-out templates are available online at www.extron.com.
3
Page 4
Insert “Show Me” Cables into the grommet plate.
1
Attach the “Show Me” Cable Trim Plate to the top of the module, using the module screws.
2
Attach the grommet plate to the bottom of the module, using the module screws.
3
Preparing the Cable Cubby
e the AAP plate on the connectivity brackets,
Step 1 (Only for multiple enclosures) — Assemble Enclosures
Before attaching the enclosure, ensure the keyhole mounting holes are orientated in the same direction.
2
Attach the enclosures together with the four pan-head mounting screws and washers that were removed in step 1.
1
Using a #2 screw driver, unscrew the four pan-head screws that attach the enclosure sides of the Cable Cubby together. Repeat this step on the corresponding side of the other enclosure.
Detach side panels of both enclosures.
Step 2 — Assemble Connectivity Modules
Connectivity modules allow you to populate the Cable Cubby enclosure with a combination of AAPs, cable pass-through, or Retractors. Follow the steps below to assemble the connectivity modules of your choice.
Option 1: AAP Module
Secure up to three single-space
1
AAPs in the AAP plate.
3
Repeat steps 1 and 2 to
3
add more enclosures to the extension.
Secur using four of the provided module screws.
#4-40 Nut with Captive Washer
2
Option 2: Cable Pass-Through Module
1
Insert cables through the bottom of the connectivity bracket and into the holes of the grommet plate.
3
Snap the included hole plugs into any unused holes.
2
Secure the grommet plate on the connectivity bracket, using four of the provided module screws.
Insert cables through the bottom of the connectivity bracket. Connect cables to the AAPs.
Option 3: Retractor Bracket
NOTE: The opening of the bracket should be
installed towards the outside of the enclosure.
2
Secure the bracket using four of the provided pan-head mounting screws with star washers. Tighten the screws using a screwdriver.
1
Insert the bracket as shown.
The bracket may be installed on the left or right side of the enclosure and at the lowest height.
left
he
4
Page 5
Cable Cubby 650 UT • Installation Guide (Continued)
125V~ 12A MAX TOTAL
125V~ 12A MAX TOTAL
Step 3 — Install the Modules
Determine where the connectivity module and/or power module will be installed in the Cable Cubby. The modules may be installed on the left or right side of the enclosure and at various heights.
For the power module:
WARNING: Risk of Electric Shock. To ensure
proper electrical grounding, use the provided #6-32 mounting screws with the star washers.
AVERTISSEMENT : Risque de choc électrique.
An d’assurer une mise à la terre correcte, utilisez les xations de mise à la terre #6-32 et les rondelles en étoile fournies.
Secure the modules using
2
four of the provided pan-head mounting screws and star washers.
1
Insert the modules into the Cable Cubby.
125V~ 12A MAX TOTAL
Mounting the Cable Cubby under the Table
Align the enclosure with the pre-drilled holes under the furniture. Secure the enclosure with the appropriate screws (see Cut the
hole in the table and pre-drill mounting holes on page 3).
Insert a mounting screw appropriate for
Hook the Cable Cubby assembly
2
onto the screws at the keyhole locations, as shown at right.
Slide the Cable Cubby assembly into slot.
Align the other mounting holes on the assembly with the pre-drilled holes on the furniture.
Tighten the screws to secure the Cable Cubby assembly.
Insert and tighten the rest of the mounting screws
3
through remaining mounting holes on the enclosure and into the pre-drilled holes in the furniture.
1
the furniture material into each of the keyhole locations. Tighten each screw until it protrudes 1/4 inch from the bottom of the table.
Mounting holes
5
Page 6
Cable Cubby 650 UT • Installation Guide (Continued)
Remove two enclosure screws (one on each side) from this position. Then, mount the Retractors as shown at left.
Cable Release Assembly
e the clip
E
Installing Retractors
Follow the steps below to install Retractors. For horizontal or angular Retractor mounting, see the information below at right, then follow the steps below.
Horizontal Mounting
Cable Release Assembly
Remove two enclosure screws (one on each side) from this position. Then, mount the Retractors as shown at left.
See the Cable Retractor Setup Guide, available on the
Extron website, for additional steps.
Secur
3
to the pin.
2
Insert the included pin through the Retractor mounting hole on the side of the Retractor assembly bracket.
Insert Retractors into the Retractor bracket.
1
Secure the locking screw
4
on each Retractor. Do not overtighten.
Alternative Retractor Configuration for Cable Cubby 650 UT
Optional Double Retractor bracket mounting:
Install brackets as shown at right. Two double Retractor brackets can mount up to four Retractors.
Angular Mounting
Remove the enclosure screws as shown above, then follow this step:
Move the cable release assembly upward until the angular mounting hole is visible. Reinstall the enclosure screws in this hole (both sides).
Cable Cubby 650UT
Side View
E
6
2
Secure the brackets using four of the provided pan-head mounting screws with star washers. Tighten the screws using a screwdriver.
1
Insert the brackets as shown.
The bracket may be installed on the left or right side of the enclosure and at the lowest height.
Page 7
Routing and Connecting Cables
For cable pass-through applications,
1
allow at least 36 inches (0.9 m) of cable loop for each cable.
NOTE: Ensure that there is no tension on the power cable.
Connect cables to the AV system
3
and connect the AC power cord.
Using zip ties, secure cables to the holes
2
on the bottom of the Cable Cubby.
CAUTION:
Risk of Electric Shock.
This equipment must be grounded.
ATTENTION :
Risque de choc électrique.
Cet équipement doit être xé au sol.
Installation Checklist
Planning (page 1)
Check with local and state regulations before starting the installation Check all parts and equipment before installation Determine number of enclosures to install
Preparing the Table (page 2)
Determine the best location for the enclosure Verify sufcient space under furniture Cut a hole in the table and pre-drill mounting holes (page 3)
Preparing the Cable Cubby (page 4)
If applicable, assemble enclosures Assemble connectivity modules Install the modules (page 5)
Mounting the Cable Cubby (page 5)
Mount the Cable Cubby under the table
Installing Retractors (page 6)
Remove Retractor screws for horizontal and angular mount applications Install Retractors into the bracket
Routing and Connecting cables (page 7)
Dress cables under the table Connect cables to the AV system
7
Page 8
Extron Headquarters
+1.800.633.9876 (Inside USA/Canada Only)
Extron USA - West Extron USA - East +1.714.491.1500 +1.919.850.1000 +1.714.491.1517 FAX +1.919.850.1001 FAX
Extron Europe
+800.3987.6673 (Inside Europe Only)
+31.33.453.4040 +31.33.453.4050 FAX
© 2017 Extron Electronics All rights reserved. www.extron.com
8
Extron Asia
+65.6383.4400 +65.6383.4664 FAX
Extron Japan
+81.3.3511.7655 +81.3.3511.7656 FAX