Extron electronic XTP SR HDMI User Manual

XTP SR HDMI
XTP HDMI Scaling Receiver
User Guide
XTP Extenders
68-2007-01 Rev. D
02 15

Safety Instructions

Safety Instructions • English
WARNING: This symbol, , when used on the product, is intended to
ATTENTION: This symbol, , when used on the product, is intended
to alert the user of important operating and maintenance (servicing) instructions in the literature provided with the equipment.
For information on safety guidelines, regulatory compliances, EMI/EMF compatibility, accessibility, and related topics, see the Extron Safety and Regulatory Compliance Guide, part number 68-290-01, on the Extron website,
www.extron.com.
Instructions de sécurité • Français
AVERTISSEMENT : Ce pictogramme, , lorsqu’il est utilisé sur le
produit, signale à l’utilisateur la présence à l’intérieur du boîtier du produit d’une tension électrique dangereuse susceptible de provoquer un choc électrique.
ATTENTION : Ce pictogramme, , lorsqu’il est utilisé sur le produit,
signale à l’utilisateur des instructions d’utilisation ou de maintenance importantes qui se trouvent dans la documentation fournie avec le matériel.
Pour en savoir plus sur les règles de sécurité, la conformité à la réglementation, la compatibilité EMI/EMF, l’accessibilité, et autres sujets connexes, lisez les informations de sécurité et de conformité Extron, réf. 68-290-01, sur le site Extron, www.extron.com.
Sicherheitsanweisungen • Deutsch
WARNUNG: Dieses Symbol auf dem Produkt soll den Benutzer
darauf aufmerksam machen, dass im Inneren des Gehäuses dieses Produktes gefährliche Spannungen herrschen, die nicht isoliert sind und die einen elektrischen Schlag verursachen können.
Инструкция по технике безопасности Русский
ПРЕДУПРЕЖДЕНИЕ: Данный символ, , если указан
на продукте, предупреждает пользователя о наличии неизолированного опасного напряжения внутри корпуса продукта, которое может привести к поражению электрическим током.
ВНИМАНИЕ: Данный символ, , если указан на продукте,
предупреждает пользователя о наличии важных инструкций по эксплуатации и обслуживанию в руководстве, прилагаемом к данному оборудованию.
Для получения информации о правилах техники безопасности, соблюдении нормативных требований, электромагнитной совместимости (ЭМП/ЭДС), возможности доступа и других вопросах см. руководство по безопасности и соблюдению нормативных требований Extron на сайте Extron: www.extron.com, номер по каталогу - 68-290-01.
Chinese Simplified(简体中文)
警告产品上的这个标志意在警告用户该产品机壳内有暴露的危险 电压,
有触电危险。
注意 产品上的这个标志意在提示用户设备随附的用户手册中有
重要的操作和维护(维修)说明。
关于我们产品的安全指南、遵循的规范、EMI/EMF 的兼容性、无障碍 使用的特性等相关内容,敬请访问 Extron 网站 www.extron.com,参见 Extron 安全规范指南,产品编号 68-290-01
Chinese Traditional )
警告: 若產品上使用此符 號,是為了提醒使 用者,產品機殼內存在著
可能會導致觸電之風險的未絕緣危險電壓。
VORSICHT: Dieses Symbol auf dem Produkt soll dem Benutzer in der
im Lieferumfang enthaltenen Dokumentation besonders wichtige Hinweise zur Bedienung und Wartung (Instandhaltung) geben.
Weitere Informationen über die Sicherheitsrichtlinien, Produkthandhabung, EMI/EMF-Kompatibilität, Zugänglichkeit und verwandte Themen finden Sie in den Extron-Richtlinien für Sicherheit und Handhabung (Artikelnummer 68-290-01) auf der Extron-Website, www.extron.com.
Instrucciones de seguridad • Español
ADVERTENCIA: Este símbolo, , cuando se utiliza en el producto,
avisa al usuario de la presencia de voltaje peligroso sin aislar dentro del producto, lo que puede representar un riesgo de descarga eléctrica.
ATENCIÓN: Este símbolo, , cuando se utiliza en el producto, avisa
al usuario de la presencia de importantes instrucciones de uso y mantenimiento recogidas en la documentación proporcionada con el equipo.
Para obtener información sobre directrices de seguridad, cumplimiento de normativas, compatibilidad electromagnética, accesibilidad y temas relacionados, consulte la Guía de cumplimiento de normativas y seguridad de Extron, referencia 68-290-01, en el sitio Web de Extron, www.extron.com.
注意若產品上使用此符號,是為了提醒使用者,設備隨附的用戶手冊中有重
要的操作和維護(維修)説明。
有關安全性指導方針、法規遵守、EMI/EMF 相容性、存取範圍和相關主題的詳細資 訊,請瀏覽 Extron 網站:www.extron.com,然後參閱《Extron 安全性與法規 遵守手冊》,準則編號 68-290-01。
Japanese
警告: この記 号 が製品上に表示されている場合は、筐体内に絶縁されて
いない高電圧が流れ、感電の危険があることを示しています。
注意: この記号 が製品上に表示されている場合は、本機の取扱説明書
に 記載さ れて いる重 要な操 作 と保 守 ( 整 備)の 指 示につ いてユーザ ー の 注 意を喚起するものです。
安全上のご注意、法規厳守、EMI/EMF適合性、その他の関連項目に つ い て は 、エ ク スト ロン の ウ ェ ブ サ イト www.extron.com よ り 『 Extron Safety and Regulatory Compliance Guide』 ( P/N 68-290-01) をご覧ください。
Korean
경고: 이 기호 가 제품에 사용될 경우, 제품의 인클로저 내에 있는
접지되지 않은 위험한 전류로 인해 사용자가 감전될 위험이 있음을 경고합니다.
주의: 이 기호 가 제품에 사용될 경우, 장비와 함께 제공된 책자에 나와
있는 주요 운영 및 유지보수(정비) 지침을 경고합니다.
안전 가이드라인, 규제 준수, EMI/EMF 호환성, 접근성, 그리고 관련 항목에 대한 자세한 내용은 Extron 웹 사이트(www.extron.com)의 Extron 안전 및 규제 준수 안내서, 68-290-01 조항을 참조하십시오.

FCC Class A Notice

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part15 of the FCC rules. The ClassA limits provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause interference. This interference must be corrected at the expense of the user.
ATTENTION:
The Twisted Pair Extension technology works with shielded twisted pair (STP) cables
For more information on safety guidelines, regulatory compliances, EMI/EMF
only. To ensure FCC Class A and CE compliance, STP cables and STP connectors
are also required.
compatibility, accessibility, and related topics, see the “Extron Safety and
Regulatory Compliance Guide” on the Extron website.

Copyright

© 2015 Extron Electronics. All rights reserved.
Trademarks
All trademarks mentioned in this guide are the properties of their respective owners.
The following registered trademarks
(®)
, registered service marks
(SM)
, and trademarks
(TM)
are the property of
RGBSystems, Inc. or Extron Electronics:
Registered Trademarks
AVTrac, Cable Cubby, CrossPoint, eBUS, EDID Manager, EDID Minder, Extron, Flat Field, GlobalViewer, Hideaway, Inline, IPIntercom, IPLink, KeyMinder, LockIt, MediaLink, PlenumVault, PoleVault, PowerCage, Pure3, Quantum, SoundField, SpeedMount, SpeedSwitch, SystemINTEGRATOR, TeamWork, TouchLink, V-Lock, VersaTools, VN-Matrix, VoiceLift, WallVault, WindoWall, XTP, and XTP Systems
Registered Service Mark
AAP, AFL (Accu-RateFrameLock), ADSP(Advanced Digital Sync Processing), Auto-Image, CableCover, CDRS(ClassDRippleSuppression), DDSP(Digital Display Sync Processing), DMI (DynamicMotionInterpolation), DriverConfigurator, DSPConfigurator, DSVP(Digital Sync Validation Processing), DTP, eLink, EQIP, FastBite, FlexOS, FOXBOX, Global Configurator, IP Intercom HelpDesk, LinkLicense, MAAP, MicroDigital, ProDSP, QS-FPC(QuickSwitch Front Panel Controller), Scope-Trigger, ShareLink, SIS (Simple Instruction Set), Skew-Free, SpeedNav, Triple-Action Switching, WebShare. XTRA, ZipCaddy, ZipClip
(SM)
: S3 Service Support Solutions
Trademarks
(®)
(™)

Conventions Used in this Guide

Notifications

The following notifications are used in this guide:
WARNING: Potential risk of severe injury or death. AVERTISSEMENT : Risque potentiel de blessure grave ou de mort.
ATTENTION:
Risk of property damage.
Risque de dommages matériels.
NOTE: A note draws attention to important information.
TIP: A tip provides a suggestion to make working with the application easier.

Software Commands

Commands are written in the fonts shown here:
^AR Merge Scene,,Op1 scene 1,1 ^B 51 ^W^C
[01] R 0004 00300 00400 00800 00600 [02] 35 [17] [03]
E X! *X1&* X2)* X2#* X2! CE}
NOTE: For commands and examples of computer or device responses mentioned
in this guide, the character “0” is used for the number zero and “O” represents the capital letter “o.”
Computer responses and directory paths that do not have variables are written in the font shown here:
Reply from 208.132.180.48: bytes=32 times=2ms TTL=32
C:\Program Files\Extron
Variables are written in slanted form as shown here:
ping xxx.xxx.xxx.xxx —t
SOH R Data STX Command ETB ETX
Selectable items, such as menu names, menu options, buttons, tabs, and field names are written in the font shown here:
From the File menu, select New.
Click the OK button.

Specifications Availability

Product specifications are available on the Extron website, www.extron.com.

Contents

Introduction............................................................ 1
About this Guide ................................................. 1
About the XTP SR HDMI Scaling Receiver .......... 1
Key Features ...................................................... 2
Installation .............................................................. 4
Rear Panel Connectors ....................................... 4
Making Connections ........................................... 6
HDMI Connection ........................................... 6
TP Cable Termination and
Recommendations ........................................ 7
RS-232 and IR Over XTP Communication ...... 9
Power Connection .......................................... 9
Operation .............................................................. 12
Front Panel Features and Indicators .................. 12
Rear Panel HDMI Audio Switch ........................ 13
Audio Output Overview ..................................... 13
On-Screen Display Menu System ..................... 13
Menu Navigation Using Front Panel
Controls ....................................................... 14
Menu Overview ............................................. 14
Image Reset Submenu ................................. 15
Picture Controls Submenu ............................ 15
User Presets Submenu ................................. 16
Input Configuration Submenu ....................... 17
Output Configuration Submenu .................... 17
Advanced Configuration Submenu ............... 19
Front Panel Lockout Mode (Executive Mode) .... 19
Using Command and Response Tables
for SIS Commands ...................................... 21
Symbol Definitions ........................................ 22
Command and Response Tables for SIS
Commands ..................................................... 23
Picture Adjustment Commands .................... 23
Output Configuration Commands ................. 25
Audio Configuration Commands ................... 26
Preset Commands ........................................ 26
Advanced Configuration Commands ............ 27
XTP System Configuration Software ............. 29
Installing the XTP System Configuration
Software .......................................................... 29
Using the XTP System Configuration
Software .......................................................... 30
Connections ................................................. 30
Menu Bar ..................................................... 31
Device Settings ............................................. 34
Reference Information ...................................... 43
Mounting .......................................................... 43
Tabletop Mounting ........................................ 43
Mounting Kits ............................................... 43
Updating Firmware with Firmware Loader ......... 44
Downloading Extron Firmware Loader .......... 44
Installing Firmware Loader ............................ 45
Downloading Firmware ................................. 45
Installing Firmware with Firmware Loader ...... 46
SIS Configuration and Control ........................ 20
Host Device Connection ................................... 20
SIS Programming Guide ................................... 20
Host-to-Device and Device-to-Host
Communication ........................................... 20
Device-Initiated Message .............................. 20
Error Responses ........................................... 21
vXTP SR HDMI Scaling Receiver • Contents
XTP SR HDMI Scaling Receiver • Contents vi

Introduction

This section contains general information about this guide and the Extron XTP SR HDMI scaling receiver. Topics in this section include:
About this Guide
About the XTP SR HDMI Scaling Receiver
Key Features

About this Guide

This guide provides installation, operation, control, and reference information for the XTP SR HDMI scaling receiver. In this guide, the terms “scaling receiver” and “XTP SR HDMI” are used interchangeably to refer to the XTP SR HDMI scaling receiver.

About the XTP SR HDMI Scaling Receiver

The Extron XTP SR HDMI receives video, audio, bidirectional RS-232 and IR, and Ethernet signals over a single twisted pair cable. It is HDCP-compliant and supports 1080p/60 Deep Color, 1920x1200 signals, and embedded HD lossless audio formats. It works with Extron XTP devices in matrix, or point-to-point applications for signal distribution and long-distance transmission (up to 330 feet) between remote endpoints, using shielded twisted pair cable.
It can be powered locally or remotely through an Extron XTP Power Injector or XTP matrix switcher (see Power Connection on page 9).
This device can be controlled through the on-screen display (OSD) menu (see On-Screen
Display Menu System on page 13), Extron Simple Instruction Set (SIS) commands (see SIS Configuration and Control on page 20), or the XTP System Configuration Software
(see XTP System Configuration Software on page 29).
XTP SR HDMI Scaling Receiver • Introduction 1
The following diagram shows one way the XTP SR HDMI can be integrated in an XTP
AD
J
XTP
ADJ
ST
XTP Transmitter
point-to-point application. The scaling receiver can also be used with an XTP matrix switcher (see the XTP matrix switcher user guide for more details on matrix applications).
HDMI Cable
XTP
HBR
SIGNAL
HDMI
HDCP
DVI-HDMI Cable
VGA Cable
1
NORMAL
MODE
AUTO
FIG
CH
CON
SWIT
Ethernet
AUDIO
BITSTREAM
S/PDIF
3
2
O T
AU
HDMI Cable
DVI Cable
TouchLink Control
VGA Cable
Audio Cable
Extron
Extron Cable Cubby
Audio Cable
Ethernet
XTP Cable (330')
HDMI Cable
CONFIG
Figure 1. Typical XTP SR HDMI Point-to-Point Application
Projector
M
LPC
G
UDIO A
ANALO
EAM
BITSTR
S/PDIF
HBR
XTP
HDMI
SIGNAL
CP
HD
ONFIG C
LPCM
ANALOG
MENU ENTER
Extron XTP SR HDMI
XTP Scaling Receiver
03
T USW 1
3
P T X
STATUS
2
1
SIGNAL
CP
HD
Extron XTP T USW 103
JUST
AD
XTP SR HDMI
U ENTER
MEN
ADJUST
XTP SR HDMI
XTP

Key Features

Reliable cable infrastructure — Transmits or receives video, audio, bidirectional RS-232 and IR, and Ethernet up to 330 feet (100 m) over a single shielded twisted pair cable, providing high reliability and maximum performance on an economical and easily installed cable infrastructure.
Support for 1080p/60 Deep Color and 1920x1200 signals — Supports digital signal transmission up to 330 feet over a single twisted pair cable, maintaining superior image quality at the highest resolutions.
Shielded twisted pair cable compatibility — Optimized for use with common shielded twisted pair cable types. XTP systems fully support a maximum transmission distance of 330 feet (100 meters) for all compatible resolutions when used with shielded twisted pair cable. Shielded twisted pair cabling with solid center conductor sizes of 24 AWG or better is recommended for optimal performance.
Bidirectional RS-232 and IR insertion — Allows a remote display to be controlled without the need for additional cabling through bidirectional RS-232 control and IR signals inserted into the XTP output.
HDMI specification features — Support data rates up to 6.75 Gbps, Deep Color up to 12-bit, 3D, HD lossless audio formats, and CEC pass-through.
HDCP compliance — Ensures display of content-protected media and interoperability with other HDCP-compliant devices.
XTP SR HDMI Scaling Receiver • Introduction 2
EDID Minder — Automatically manages EDID communication between connected devices.
It ensures that all sources power up properly and reliably outputs content for display. Key Minder — Authenticates and maintains continuous HDCP encryption between input
and output devices to ensure quick and reliable switching in professional AV environments, while enabling simultaneous distribution of a single source signal to one or more displays.
Ethernet extension — Centralized 10/100Base-T Ethernet communication can be implemented via an Ethernet pass-through port to reduce the amount of independent network drops required within a system.
Remote power capability — To simplify integration, XTP transmitters and receivers can be powered by the XTP CrossPoint Matrix Switcher or XTP power injectors.
Multiple embedded audio formats — Compatible with a broad range of multi-channel audio signals, providing reliable operation with HDMI sources.
HDMI audio de-embedding with analog stereo and digital S/PDIF audio outputs — Digital HDMI audio is made available as a balanced or unbalanced analog stereo signal on captive screw connectors or a S/PDIF connector.
EDID and HDCP transmission — Supports DDC channels that are actively buffered, allowing continuous communication between source and display.
Contact closure device control — Enables control of room functions such as projector lifts, screen operations, and other environmental controls.
Aspect ratio control — Controls the aspect ratio of the video output by selecting a FILL mode, which provides a full screen output, or a FOLLOW mode, which preserves the original aspect ratio of the input signal.
Image freeze control — Freezes a live image through RS-232 or USB control. Internal test patterns — Helps calibrate and setup the output. XTP integrated system products compatibility — Is compatible with all XTP integrated
system products. XTP is a flexible, reliable signal switching and distribution system that provides a completely integrated solution for multiple digital and analog formats.
Front panel security lockout — Allows security lockout of front panel buttons. UL 2043 plenum rated — Meets UL 2043 for smoke and heat release for installation
within a plenum airspace above a drop ceiling (power supply excluded). Above-the-ceiling placement conceals the scaling receiver to prevent theft, and is convenient for installing equipment when space inside the room is limited.
XTP SR HDMI Scaling Receiver • Introduction 3

Installation

IABC DEFG
This section contains installation procedures for the XTP SR HDMI and wiring details. Topics in this section include:
Rear Panel Connectors
Making Connections
The XTP SR HDMI can be placed on a tabletop or mounted in a rack or under a desk (see
Mounting on page 43).

Rear Panel Connectors

POWER 12V
1.0 A MAX
SIG LINK
XTP IN
OVER XTP
RS-232 IR
LAN
Rx GTx
AUDIO
ON
OFF
RxTx
HDMI
OUTPUTS
AUDIO
LR
−+−+
S/PDIF
REMOTERELAYS
1
RS-232
2
Tx Rx G
H
XTP input connector (page 4)
A
LAN connector (page 5)
B
RS-232 and IR Over XTP connector
C
(page 5)
HDMI output connector (page 5)
D
Analog audio output connector
E
(page 5)
Figure 2. XTP SR HDMI Rear Panel Connectors
XTP input connector — Connect a twisted pair cable to the RJ-45 connector labeled
A
XTP IN on the XTP SR HDMI and the XTP output port on another XTP device to pass
all signals (see TP Cable Termination and Recommendations on page 7). This cable carries the following signals:
Digital video
Digital audio
Bidirectional RS-232 and IR commands
Remote power
Ethernet communication
System communication
Signal LED indicator — Lights green when the XTP SR HDMI receives an active XTP input signal from a compatible transmitter or matrix switcher.
Link LED indicator — Lights yellow when a valid XTP link is established.
S/PDIF audio output connector
F
(page 6)
Relay connectors (page 6)
G
Remote RS-232 connector (page 6)
H
DC power connector (page 6)
I
RESET
XTP SR HDMI Scaling Receiver • Installation 4
ATTENTION:
Do not tin the wires!
Balanced Audio Output
Slee
Unbalanced Audio Output
No Ground Here
Tx Rx G Tx Rx
IR
Tx Rx G Tx Rx
RS-232
Do not connect this connector to a computer data or telecommunications
network.
Ne connectez pas ce port à des données informatiques ou à un réseau de
télécommunications.
XTP remote power is intended for indoor use only. No part of the network that
uses XTP remote power should be routed outdoors (see Remote power on page 11).
XTP à distance est destiné à une utilisation en intérieur seulement. Aucune
partie du réseau qui utilise l’alimentation XTP à distance ne peut être routée en extérieur (voir Remote power à la page 11).
LAN connector — Connect a control device or device to be controlled to the RJ-45
B
connector labeled LAN for 10/100Base-T Ethernet communication through this pass-through port. LEDs on the connector indicate link and activity status.
RS-232 Over XTP port — To pass bidirectional serial or other control signals
C
between XTP-compatible devices, connect a control device to the 5-pole captive screw connector. The port includes only the 3 poles labeled “RS-232.”
IR Over XTP port — To transmit and receive IR signals (up to 40 kHz), connect a control device to the 5-pole captive screw connector. This port includes only the 2 poles labeled “IR” and shares the ground pole with the RS-232 port.
RS-232
IR
NOTE: RS-232 and IR data can be transmitted simultaneously (see RS-232 and IR
Over XTP Communication on page 9 for wiring details).
HDMI output connector — Connect a digital video display to the female HDMI
D
connector (see Rear Panel HDMI Audio Switch on page 13 to mute or unmute embedded audio output). It can accept HDMI, DVI (with an appropriate adapter), or DisplayPort video signals.
NOTES:
The maximum cable length is 15 feet.
Use Extron LockIt lacing brackets to secure HDMI connectors to the device
(see HDMI Connection on page 6).
Analog audio output connector — Connect a balanced or unbalanced, stereo or
E
mono audio output device to the 3.5 mm, 5-pole captive screw connector for 2-channel stereo analog audio output (see figure 3 for wiring details).
NOTE: If the device is receiving 2-channel LPCM embedded audio on the HDMI
input signal, it is extracted and converted to a stereo analog signal.
Tip
Ring
ves Tip
Ring
LR
Sleeves
Tip Tip
No Ground Here
LR
Figure 3. Audio Output Wiring
ATTENTION:
For unbalanced audio, connect the sleeves to the contact ground. Do not
connect the sleeves to the negative (-) contacts.
Pour l’audio asymétrique, connectez les manchons au contact au sol. Ne pas
connecter les manchons aux contacts négatifs (–).
XTP SR HDMI Scaling Receiver • Installation 5
S/PDIF audio output connector — Connect an audio device to the female orange
1
F
RCA connector for digital S/PDIF audio output (see Audio Output Overview on page 13 for supported audio formats on the S/PDIF output). The type of audio present on this output is dictated by the following:
The audio format selected on the source material or device.
The source device automatically outputting an audio format through EDID.
Relay connectors — Connect equipment that can be controlled via momentary or
G
latching contact, such as projector screens or lifts, to the normally open relays.
ATTENTION:
Do not exceed 24 V at 1.0 A for each port.
Ne pas dépasser 24volts à 1,0A pour chaque port.
Remote RS-232 connector — Connect a host device to the 3.5 mm, 3-pole captive
H
screw connector for serial control of the scaling receiver.
DC power connector and LED — Connect the external 12 V, 1.0 A power supply
I
to the 2-pole captive screw connector. The Power LED lights to indicate the device is receiving power.
NOTE: The XTP SR HDMI can also be powered remotely (see Power Connection
on page 9).

Making Connections

HDMI Connection

Use an Extron LockIt Lacing Bracket to secure an HDMI cable to each device as follows:
3
3
4
2
5
Figure 4. Installing the LockIt Lacing Bracket
1. Plug the HDMI cable into the panel connection (see figure 4, 1).
2. Loosen the HDMI connection mounting screw from the panel enough to allow the
LockIt lacing bracket to be placed over it (2). The screw does not have to be removed.
3. Place the LockIt lacing bracket on the screw and against the HDMI connector, then
tighten the screw to secure the bracket (3).
4. Loosely place the included tie wrap around the HDMI connector and the LockIt lacing
bracket as shown (4).
5. While holding the connector securely against the lacing bracket, use pliers or similar
tools to tighten the tie wrap, then remove any excess length (5).
ATTENTION:
Connect and pull the tie wraps until they are secure. Do not overtighten.
Connectez et tirez les serre-câbles jusqu’à ce qu’ils soient sécurisés. Ne pas
trop serrer.
XTP SR HDMI Scaling Receiver • Installation 6

TP Cable Termination and Recommendations

Inser
Pins:
Pin
1 2 3
4 5 6
7 8
Wire color
White-green Green White-orange
Blue White-blue Orange
White-brown Brown
Wire color
T568A T568B
White-orange Orange White-green
Blue White-blue Green
White-brown Brown
Use the following pin configurations for twisted pair cables.
Straight-through Cable
12345678
t Twisted
Pair Wires
Figure 5. Twisted Pair Cable Termination
Supported cables
The XTP SR HDMI is compatible with shielded twisted pair (F/UTP, SF/UTP, and S/FTP) and unshielded twisted pair (U/UTP) cables.
(for connection to a switch, hub, or router)
TIA/EIA-T568A TIA/EIA-T568B
Pin Wire Color Pin Wire Color
1 White-green 1 White-orange
2 Green 2 Orange
3 White-orange 3 White-green
4 Blue 4 Blue
5 White-blue 5 White-blue
6 Orange 6 Green
7 White-brown 7 White-brown
8 Brown 8 Brown
ATTENTION:
Do not use Extron UTP23SF-4 Enhanced Skew-Free AV UTP cable or STP201
cable to link the XTP products.
N’utilisez pas le câble AV Skew-Free UTP version améliorée UTP23SF d’Extron ou
le câble STP201 pour relier les produits XTP.
To ensure FCC Class A and CE compliance, STP cables and STP connectors are
required.
Afin de s’assurer de la compatibilité entre FCC Classe A et CE, les câbles STP et
les connecteurs STP sont nécessaires.
XTP SR HDMI Scaling Receiver • Installation 7
Cable recommendations
Extron recommends using the following practices to achieve full transmission distances up to 330 feet (100 m) and reduce transmission errors.
Use the following Extron XTP DTP 24 SF/UTP cables and connectors for the best
performance:
XTP DTP 24/1000 Non-Plenum 1000’ (305 m) spool 22-236-03
XTP DTP 24P/1000 Plenum 1000’ (305 m) spool 22-235-03
XTP DTP 24 Plug Package of 10 101-005-02
If not using XTP DTP 24 cable, at a minimum, Extron recommends 24 AWG, solid
conductor, STP cable with a minimum bandwidth of 400 MHz.
Terminate cables with shielded connectors to the TIA/EIA-T568B standard.
Limit the use of more than two pass-through points, which may include patch points,
punch down connectors, couplers, and power injectors. If these pass-through points are required, use shielded couplers and punch down connectors.
NOTE: When using STP cable in bundles or conduits, consider the following:
Do not exceed 40% fill capacity in conduits.
Do not comb the cable for the first 20 M, where cables are straightened, aligned,
and secured in tight bundles.
Loosely place cables and limit the use of tie wraps or hook-and-loop fasteners.
Separate twisted pair cables from AC power cables.
XTP SR HDMI Scaling Receiver • Installation 8

RS-232 and IR Over XTP Communication

Custom
RS-232 Device
The RS-232 and IR Over XTP connector is for pass-through transmission of serial signals, such as projector control signals, and infrared data. To pass bidirectional serial command signals between XTP-compatible devices, connect a control device to the three leftmost poles (Tx, Rx, and G) of the 5-pole captive screw connector. To transmit and receive IR signals, connect a control device to the three rightmost poles (G, Tx, and Rx). The ground (G) pole is shared.
NOTE: RS-232 and IR data can be transmitted or received simultaneously (see figure 6
below for wiring considerations).
IR Device
TxRx
Tx/Rx
Pins
RxTx
IR
G
RxTx
RS-232
Figure 6. Wiring the RS-232 and IR Over XTP Connector
ATTENTION: The length of exposed wires in the stripping process is critical. ATTENTION : La longueur des câbles exposés est primordiale lorsque l’on entreprend
de les dénuder.
The ideal length is 3/16 inch (5 mm).
La longueur idéale est de 5mm (3/16inches).
Any longer and the exposed wires may touch, causing a short circuit between
them.
S’ils sont un peu plus longs, les câbles exposés pourraient se toucher et provoquer
un court circuit.
Any shorter and the wires can be easily pulled out even if tightly fastened by the
captive screws.
S’ils sont un peu plus courts, ils pourraient sortir, même s’ils sont attachés par les
vis captives.
G
RxTx
G

Power Connection

Apply power to the scaling receiver locally with the provided power supply or remotely with a power injector or a matrix switcher.
ATTENTION:
XTP remote power is intended for indoor use only. No part of the network that uses
XTP à distance est destiné à une utilisation en intérieur seulement. Aucune partie
XTP remote power should be routed outdoors (see Remote power on page 11).
du réseau qui utilise l’alimentation XTP à distance ne peut être routée en extérieur (voir Remote power à la page 11).
XTP SR HDMI Scaling Receiver • Installation 9
Local power
Connector
Smooth
Ridges
AA
SECTION A–A
Power Supply
Output Cord
Tie Wrap
3
Captive Screw
5
Figure 7. Power Wiring
The XTP SR HDMI can be connected to a local power supply (see figure 7).
WARNING: Electric shock hazard. The two power cord wires must be kept separate
while the power supply is plugged in. Remove power before wiring.
AVERTISSEMENT :
Risque de choc électrique grave. Les deux cordons d’alimentation doivent être tenus à l’écart l’un de l’autre quand l’alimentation est branchée. Couper l’alimentation avant de faire l’installation électrique.
ATTENTION:
This product is intended for use with a UL Listed power source marked “Class 2”
or “LPS” rated 12 VDC, 1.0 A minimum. Always use a power supply supplied by or specified by Extron. Use of an unauthorized power supply voids all regulatory compliance certification and may cause damage to the supply and the unit.
Ce produit est destiné à une utilisation avec une source d’alimentation listée UL
avec l’appellation « Classe 2 » ou « LPS » et normée 12 Vcc, 1,0 A minimum. Utilisez toujours une source d’alimentation fournie par Extron. L’utilisation d’une source d’alimentation non autorisée annule toute conformité réglementaire et peut endommager la source d’alimentation ainsi que l’unité.
Unless otherwise stated, the AC/DC adapters are not suitable for use in air handling
spaces or in wall cavities. The installation must always be in accordance with the applicable provisions of National Electrical Code ANSI/NFPA 70, article 725 and the Canadian Electrical Code part 1, section 16. The power supply shall not be permanently fixed to a building structure or similar structure.
Sauf mention contraire, les adaptateurs AC/DC ne sont pas appropriés pour
une utilisation dans les espaces d’aération ou dans les cavités murales. Cette installation doit toujours être en accord avec les mesures qui s’applique au National Electrical Code ANSI/NFPA 70, article 725, et au Canadian Electrical Code, partie 1, section 16. La source d’alimentation ne devra pas être fixée de façon permanente à une structure de bâtiment ou à une structure similaire.
Power supply voltage polarity is critical. Incorrect voltage polarity can damage the
power supply and the unit. The ridges on the side of the cord identify the power cord negative lead.
La polarité de la source d’alimentation est primordiale. Une polarité incorrecte
pourrait endommager la source d’alimentation et l’unité. Les stries sur le côté du cordon permettent de repérer le pôle négatif du cordon d’alimentation.
The length of the exposed (stripped) copper wires is important. The ideal length is
3/16 inch (5 mm).
La longueur des câbles exposés est primordiale lorsque l’on entreprend de les
dénuder. La longueur idéale est de 5 mm (3/16 inch).
TIP: Do not tin the stripped power supply leads. Tinned wires are not as secure in the
captive screw connectors and could be pulled out.
XTP SR HDMI Scaling Receiver • Installation 10
Remote power
XTP Receiver
The XTP SR HDMI can be powered remotely through an XTP Power Injector or through an XTP matrix switcher.
ATTENTION:
XTP remote power is intended for indoor use only. No part of the network that uses
XTP remote power should be routed outdoors.
XTP à distance est destiné à une utilisation en intérieur seulement. Aucune partie
du réseau qui utilise l’alimentation XTP à distance ne peut être routée en extérieur.
Power injector
To power the XTP SR HDMI remotely with an XTP Power Injector, power one device locally (see Local power on page 10) and connect an XTP Power Injector to the XTP cable run along the XTP ports (see the XTP Power Injector User Guide for more installation information).
POWER 12V
0.7A MAX
Extron XTP T HDMI
XTP Transmitter
INPUTS
XTP T HDMI
HDMI
LOOP THRU
AUDIO
AUDIO
LR
ON
OFF
−+
Power
−+
100-240V
OVER XTP
RS-232 IR
Rx GTx
50/60 Hz
---A MAX
SIG LINK
RxTx
XTP OUT
XTP
LAN
CAT 5-Type Cable
XTP PWR
PWR
RESET
Extron
12V Local Power Supply
XTP PI 100
XTP Power Injector
POWER 12V 1A MAX
Extron XTP SR HDMI
SIG LINK
XTP IN
REMOTE POWER
LAN
OVER XTP
RS-232 IR
Rx GTx
AUDIO
ON
OFF
HDMI
RxTx
AUDIO
LR
−+−+
OUTPUTS
S/PDIF
REMOTERELAYS
RS-232
1
2
RESET
Tx Rx G
Figure 8. Typical Point-to-Point Application with Remote Power
NOTE: The power injector provides remote power up to 330 feet with a shielded twisted
pair cable with 24 AWG wire.
Direct power from an XTP matrix switcher
XTP matrix switchers have a fixed amount of power available to provide remote power to connected XTP endpoints (see the XTP matrix switcher user guide for more details). To manage available power from the XTP matrix switcher, use the XTP System Configuration Software with the matrix switcher.
XTP SR HDMI Scaling Receiver • Installation 11

Operation

ADJ
XTP
ST
This section contains information for front panel operation and configuration of the XTP SR HDMI and configuration through the On-Screen Display (OSD) menu. Topics in this section include:
Front Panel Features and Indicators
Rear Panel HDMI Audio Switch
Audio Output Overview
On-Screen Display Menu System
Front Panel Lockout Mode (Executive Mode)

Front Panel Features and Indicators

CD EF GA B
ADJUST
XTP SR HDMI
CONFIG
XTP
SIGNAL
HDCP
HBR
HDMI
AUDIO
BITSTREAM
S/PDIF
LPCM
ANALOG
MENU ENTER
Figure 9. XTP SR HDMI Front Panel
Power LED indicators — Lights when power is applied to the unit. There are two
A
Power LED indicators, one on the front panel and one on the left side of the rear panel.
Config port — If desired, connect a host device to the front panel USB mini-B port for
B
configuring the switcher.
XTP indicators:
C
Signal LED indicator — Lights when an active XTP input signal is received. HDCP LED indicator — Lights when the received input signal is encrypted.
Audio indicators:
D
HBR LED indicator — Lights when the audio input is high bit rate audio. Bitstream LED indicator — Lights when the embedded audio signal format is a
Dolby® Digital, DTS, or 2-Ch Dolby.
LPCM LED indicator — Lights when the embedded audio signal is LPCM-2Ch. HDMI LED indicator — Lights when the audio input signal is multi-channel,
LCPM-2Ch, or HiDef audio. S/PDIF LED indicator — Lights when the input audio format is multi-channel or
LPCM. Analog LED indicator — Lights when the received audio format is LPCM.
Menu button — Press this button to navigate the OSD menu or enable or disable front
E
panel lockout mode (see Front Panel Lockout Mode (Executive Mode) on page 19).
XTP SR HDMI Scaling Receiver • Operation 12
Enter button — Press this button to navigate the OSD menu or enable or disable front
HDMI
AUDIO
F
panel lockout mode (see Front Panel Lockout Mode (Executive Mode) on page 19).
Adjustment knobs — Rotate the horizontal ([) or vertical ({) adjustment knob to
G
navigate the on-screen display menu or adjust submenu items.

Rear Panel HDMI Audio Switch

The XTP SR HDMI has an HDMI audio switch that mutes or unmutes the embedded audio on the HDMI output connector. The LED next to the switch lights when HDMI audio is enabled.
Move and hold the rear panel HDMI audio switch up for about 1 second to enable embedded audio on the associated HDMI connector, or move and hold the HDMI audio switch down for about 1 second to disable embedded audio on the associated HDMI connector. The switch returns to the middle position after it has been released so the device can continue to be controlled through SIS commands or from an XTP matrix switcher.

Audio Output Overview

By default, an XTP transmitter or matrix switcher prioritizes embedded digital audio over analog audio. Use SIS commands (see SIS Configuration and Control on page 20) or the XTP System Configuration Software (see XTP System Configuration Software on page 29) to manually select the audio input.
Audio Input Format HDMI S/PDIF Analog
LPCM X X X Multi-channel PCM X Dolby Digital 2/0 X X Dolby Digital 2/0 Surround X X Dolby Digital 5.1 X X Dolby Digital EX X X Dolby Digital Plus X Dolby TrueHD X DTS 2-channel X X DTS Digital Surround 5.1 X X DTS-ES Matrix 6.1 X X DTS-ES Discrete 6.1 X X DTS-HD X DTS-HD Master Audio X
ON
OFF
Audio Output LEDs

On-Screen Display Menu System

XTP SR HDMI configuration and adjustments can be performed by using SIS commands (see SIS Configuration and Control on page 20), the XTP System Configuration Software (see XTP System Configuration Software on page 29), or by using the front panel controls and the OSD menu. The OSD menu is used primarily when the receiver is first set up.
NOTE: The OSD menu has a fixed time-out of 10 seconds.
XTP SR HDMI Scaling Receiver • Operation 13

Menu Navigation Using Front Panel Controls

Menu button — Press the Menu button to activate the OSD menu or close submenus items.
Enter button — Press the Enter button to select submenu items or accept changes to settings.
Adjustment knobs — Rotate the Horizontal Adjustment ([) knob or Vertical
Adjustment
({) knob to navigate submenus and submenu items and adjust settings.

Menu Overview

The OSD menu contains six submenus with various submenu items for adjusting settings or viewing device information. Use the Menu, Enter, and adjustment knobs to navigate the OSD menu.
To open the OSD menu:
1. Connect a display device to the HDMI output connector.
2. Press the Menu button to open the OSD menu.
To navigate the OSD menu:
1. After opening the OSD menu, rotate the adjustment knobs to navigate the six
submenus. The following table shows the six submenus and their respective submenu items.
Submenus Submenu Items
Image Reset Image reset
Picture
Controls
User Presets Recall Save
Input
Configuration
Output
Configuration
Advanced
Configuration
Horizontal/
vertical position
Total pixels Horizontal/vertical
Resolution Output format Color bit
Test pattern Blank Freeze Aspect
Horizontal/vertical
size
active pixels
Brightness/
contrast
depth
Detail
ratio
System
reset
2. Press the Enter button to open the selected submenu.
3. Rotate the adjustment knobs to navigate the submenu items.
4. Press the Enter button to adjust or view a submenu item or press the Menu button to
return to the list of submenus.
To adjust a submenu item:
1. Navigate to an adjustable submenu item and press the Enter button to select the
submenu item.
2. As required, rotate the adjustment knobs or press the Enter button to adjust the
submenu item.
3. Press the Enter button to accept the new value. Press the Menu button to cancel any
pending changes.
To exit the OSD menu:
While in the list of submenus, press the Menu button to exit the OSD menu.
XTP SR HDMI Scaling Receiver • Operation 14

Image Reset Submenu

The Image Reset submenu allows the execution of a one-time reset of the image.
Figure 10. Image Reset Submenu
Image reset — Press the Enter button to reset shift and size settings to the default values.

Picture Controls Submenu

The Picture Controls submenu allows the adjustment of picture settings.
Figure 11. Picture Controls Submenu
Image position — Rotate the Horizontal Adjustment knob to adjust the horizontal (H)
position of the image. Rotate the Vertical Adjustment knob to adjust the vertical (V) position of the image.
Image size — Rotate the Horizontal Adjustment knob to adjust the horizontal (H) size of the image. Rotate the Vertical Adjustment knob to adjust the vertical (V) size of the image.
Brightness and contrast — Rotate the Horizontal Adjustment knob to adjust the brightness (Bright) of the image. Rotate the Vertical Adjustment knob to adjust the contrast (Cont) of the image.
Detail — Rotate the adjustment knobs to adjust the detail of the image.
XTP SR HDMI Scaling Receiver • Operation 15

User Presets Submenu

The User Presets submenu saves the current picture control settings for the selected input. User presets can be saved and recalled later on another input, allowing them to also be used as aspect ratio or discrete size and center shortcuts. There are 8 user preset slots available.
Figure 12. User Presets Submenu
User presets save the following settings:
Brightness and contrast
Detail
Image size and position
Recall — Rotate the adjustment knobs to select a preset to recall. Save — Rotate the adjustment knobs to select a preset to store the current picture control
settings.
XTP SR HDMI Scaling Receiver • Operation 16

Input Configuration Submenu

The Input Configuration submenu displays the total pixels and horizontal and vertical active pixels of the input signal.
Figure 13. Input Configuration Submenu
Total pixels — Displays the total pixels of the input signal. This is not configurable. Active — Displays the active horizontal (H) pixels and vertical (V) lines of the input signal.
These are not configurable.

Output Configuration Submenu

The Output Configuration submenu is used to configure of the output resolution and refresh rate. Output format and color bit depth settings are not configurable from the OSD. To configure either setting, use SIS commands (see Output Configuration Commands on page 25) or use the XTP System Configuration Software (see Input/Output tab on page 35).
Figure 14. Output Configuration Submenu
XTP SR HDMI Scaling Receiver • Operation 17
Resolution — Rotate the adjustment knobs to select a new resolution and refresh rate. The
following table shows the available resolutions and refresh rates. The resolution and refresh rate can also be changed with SIS commands (see the Output scaler rate SIS commands on page 25).
Resolution 23.98 Hz 24 Hz 25 Hz 29.97 Hz 30 Hz 50 Hz 59.94 Hz 60 Hz 75 Hz
640x480 X X X 800x600 X X X 852x480 X X X 1024x768 X X X 1024x852 X X X 1024x1024 X X X 1280x768 X X X 1280x800 X X X 1280x1024 X X X 1360x765 X X X 1360x768 X X X 1365x768 X X X 1366x768 X X X 1365x1024 X X X 1440x900 X X X 1400x1050 X X 1680x1050 X X 1600x1200 X X 1920x1200 X X 480p X X 576p X 720p X X X X X X* 1080i X X X 1080p X X X X X X X X 2K (2048x1080) X X X X X X X X
* Default Output format — Shows the HDMI output format setting. This is not configurable from
the OSD menu. To configure this setting, use SIS commands (see HDMI output format SIS commands on page 25) or use the XTP System Configuration Software (see Input/
Output tab on page 35).The following formats are available:
Auto (based on display EDID) DVI RGB 444 HDMI RGB 444 Full
HDMI RGB 444 Limited HDMI YUV 444 Full HDMI YUV 444 Limited
HDMI YUV 422 Full HDMI YUV 422 Limited
Color bit depth — Shows the color bit depth setting. This is not configurable from the OSD menu. To configure this setting, use SIS commands (see Video bit depth SIS commands on page 25) or use the XTP System Configuration Software (see Input/Output tab on page 35).
XTP SR HDMI Scaling Receiver • Operation 18

Advanced Configuration Submenu

The Advanced Configuration submenu is used to set test patterns, screen blanking and freezing, aspect ratio, and system reset.
Figure 15. Advanced Configuration Submenu
Test pattern — Rotate the adjustment knobs to select a test pattern. The available
test patterns are Crop, Alternating Pixels, 4x4 Crosshatch, Color Bars, and
Grayscale. The default setting is Off.
Crop Alternating
Pixels
Figure 16. Test Pattern Examples
NOTE: All test patterns include a single pixel border.
Blank — Rotate the adjustment knobs to turn the blank screen feature on or off. When on, the screen turns black, but the OSD menu is still available.
Freeze — Rotate the adjustment knobs to freeze or unfreeze the output. Aspect ratio — Rotate the adjustment knobs to set the output aspect ratio to Fill or
Follow. When the aspect ratio is set to Fill, the output is sized and centered to fill the
entire output screen. When the aspect ratio is set to Follow, the native aspect ratio of the input is maintained.
Factory reset — Press and hold the Enter button to reset the device to factory defaults. The scaler retains the current firmware version.

Front Panel Lockout Mode (Executive Mode)

Executive mode locks all front panel controls (RS-232 and USB control are still available). To enable or disable executive mode through the front panel, press and hold the Menu and Enter buttons simultaneously for about 2 seconds or until the Power LED blinks (see
Executive mode SIS commands on page 27 or XTP System Configuration Software
on page 29 for remote enabling or disabling of executive mode).
4x4 Crosshatch Color Bars Grayscale
XTP SR HDMI Scaling Receiver • Operation 19

SIS Configuration and Control

The XTP SR HDMI can be configured and controlled using the OSD menu (see On-Screen
Display Menu System on page 13), Extron Simple Instruction Set (SIS) commands,
or the XTP System Configuration Software (see XTP System Configuration Software on page 29). This section contains SIS communication details and SIS commands and responses when connected directly to an XTP SR HDMI. Topics in this section include:
Host Device Connection
SIS Programming Guide
Command and Response Tables for SIS Commands

Host Device Connection

Use a computer running the Extron DataViewer utility or HyperTerminal, or use a control system to make serial control of the receiver possible. To connect directly to an XTP SR HDMI, connect the computer to the XTP SR HDMI through the front panel USB Config port (see Config Port on page 12) or the rear panel Remote RS-232 connector (see Remote RS-232 connector on page 6). The protocol for the serial port is as follows: 9600 baud, no parity, 8 data bits, 1 stop bit, no flow control.

SIS Programming Guide

Host-to-Device and Device-to-Host Communication

SIS commands consist of one or more characters per field. No special characters are required to begin or end a command sequence. When the XTP SR HDMI determines that a command is valid, it executes the command and sends a response to the host device. All responses from the receiver to the host end with a carriage return and a line feed (CR/LF = ]), which signals the end of the response character string. A string is one or more characters.

Device-Initiated Message

When the switcher is connected through the serial port only and a local event occurs, the device responds by sending a message to the host.
The following copyright message is displayed after a power cycle via RS-232.
© Copyright YYYY, Extron Electronics XTP SR HDMI Vx.xx, 60-1199-01]
YYYY is the year. Vx.xx is the firmware version number.
XTP SR HDMI Scaling Receiver • SIS Configuration and Control 20

Error Responses

Space
When the XTP SR HDMI receives an SIS command and determines that it is valid, it performs the command and sends the corresponding response to the host device. If the command is determined invalid or contains invalid parameters, the receiver returns an error response to the host. The error response codes are:
E10 = Invalid command E11 = Invalid preset number E13 = Invalid parameter E14 = Not valid for this configuration E17 = Invalid command for signal type E22 = Busy

Using Command and Response Tables for SIS Commands

The command and response tables begin on page 23. Figure 17 shows the hexadecimal equivalent of ASCII characters used in the command and response tables.
NOTE: Uppercase and lowercase text can be used interchangeably unless otherwise
stated.
ASCII to Hex Conversion Table
Figure 17. ASCII to Hexadecimal Conversion
XTP SR HDMI Scaling Receiver • SIS Configuration and Control 21

Symbol Definitions

= Carriage return with line feed
]
} or |
E or W
SIS Variables for Output Resolution and Refresh Rate Combinations (where X3$ = 10-90)
Resolution 23.98 Hz 24 Hz 25 Hz 29.97 Hz 30 Hz 50 Hz 59.94 Hz 60 Hz 75 Hz
640x480 800x600 852x480 1024x768 1024x852 1024x1024
1280x768 1280x800 1280x1024 1360x765 1360x768 1365x768 1366x768 1365x1024 1440x900
1400x1050 1680x1050 1600x1200 1920x1200 480p 576p 720p 1080i 1080p 2048x1080
75 76 77 78 79 80 81 82
83 84 85 86 87 88 89 90
= Carriage return (no line feed)
• = Space character = Escape key
= Output scaler rate and refresh rate See the table below.
X3$
10 11 12
13 14 15
16 17 18
19 20 21
22 23 24
25 26 27
28 29 30
31 32 33
34 35 36
37 38 39
40 41 42
43 44 45
46 47 48
49 50 51
52 53 54
55 56
57 58
59 60
61 62
65
66 67 68 69 70
72 73 74
63 64
71
*
* = default
XTP SR HDMI Scaling Receiver • SIS Configuration and Control 22

Command and Response Tables for SIS Commands

Command ASCII Command
(host to XTP)

Picture Adjustment Commands

Video Mute
Mute video and sync
Mute video
Unmute video
View mute status
Contrast
Set contrast
Increase contrast
Decrease contrast
View contrast level
Brightness
Set brightness
Increase brightness
Decrease brightness
View brightness
2B
1B
0B
B
EX&CONT} ContX&] Set the contrast to X&. E+CONT} ContX&] E-CONT} ContX&] ECONT} ContX&]
EX&BRIT} BritX&] Set brightness level to X&. E+BRIT} BritX&] E-BRIT} Brit X&] EBRIT} BritX&]
Response
(XTP to host)
]
Vmt2
]
Vmt1
]
Vmt0
X^]
Vmt
Additional Description
Mutes video and sync.
Mute the selected input.
Display the selected input.
View mute status.
Increase the contrast level.
Decrease the contrast level.
View the contrast level.
Increase brightness level.
Decrease brightness level.
View the brightness level.
NOTES:
X^ = Video mute
X& = Picture adjustment
0 = unmute (default) 1 = mute video 2 = mute video and sync
0 to 255 (128 = default)
XTP SR HDMI Scaling Receiver • SIS Configuration and Control 23
Command ASCII Command
(host to XTP)
Detail filter
Horizontal shift
Vertical shift
Horizontal size
Vertical size
Image reset
Set detail level
Increase detail level
Decrease detail level
View detail level
Set horizontal shift
Increase horizontal shift
Decrease horizontal shift
View horizontal shift
Set vertical shift
Increase vertical shift
Decrease vertical shift
View vertical shift
Set horizontal size
Increase horizontal size
Decrease horizontal size
View horizontal size
Set vertical size
Increase vertical size
Decrease vertical size
View vertical size
Execute an image reset
EX&HDET} HdetX&] Set the detail level to X&. E+HDET} Hdet X&] E-HDET} Hdet X&] EHDET} HdetX&]
EX*HCTR} HctrX*] Set horizontal position to X*. The
E+HCTR} HctrX*] E-HCTR} HctrX*] EHCTR} HctrX*]
EX(VCTR} VctrX(] Set vertical position to X(. The
E+VCTR} VctrX(] E-VCTR} VctrX(] EVCTR} VctrX(]
EX*HSIZ} HsizX*] Set image width to X*. The default
E+HSIZ} HsizX*] E-HSIZ} HsizX*] EHSIZ} HsizX*]
EX(VSIZ} VsizX(] Set image height to X(. The default
E+VSIZ} VsizX(] E-VSIZ} VsizX(] EVSIZ} VsizX(]
A
Response
(XTP to host)
]
Img
Additional Description
Increase the detail level.
Decrease the detail level.
View the detail level.
default value is 32768). Shift the image right.
Shift the image left.
View the horizontal position.
default value is 32768). Shift the image down.
Shift the image up.
View the vertical position.
value is based on the selected output resolution.
Increase the image width.
Decrease the image width.
View the image width.
value is based on the selected output resolution.
Increase the image height.
Decrease the image height.
View the image height.
Reset shift and size settings to the default values.
NOTES:
X& = Picture adjustment X* = Horizontal position or size X( = Vertical position or size
0 to 255 (128 = default)
0 to 65535
0 to 65535
XTP SR HDMI Scaling Receiver • SIS Configuration and Control 24
Command ASCII Command
(host to XTP)
Response
(XTP to host)
Additional Description

Output Configuration Commands

Output scaler rate
Set output rate
View output rate
HDMI output format
Set HDMI output format
View HDMI output format
Test pattern
NOTE: See figure 16 on page 19 for examples of the available test patterns.
EX3$RATE} RateX3$] ERATE} RateX3$]
EX1)VTPO} VtpoX1)] EVTPO} VtpoX1)]
Select output resolution and refresh rate.
Show selected output rate.
Set the output color space and format.
View the output color space and format.
Video bit depth
Freeze
NOTES:
Set pattern
View test pattern
Set video bit depth
View video bit depth
Enable
Disable
View freeze status
X1!J TstX1!] Set the test pattern to X1!.
J
EVX1@BITD} BitdVX1@] EVBITD} BitdVX1@]
1F
0F
F
X! = Enable or disable
X1) = HDMI output format
X1! = Test pattern
X1@ = Video bit depth
X3$ = Output scaler rate and refresh rate
X1!]
Tst
]
Frz1
]
Frz0
X!]
Frz
0 = disabled or off (default for freeze command) 1 = enabled or on
0 = auto (default) 1 = DVI RGB 444 2 = HDMI RGB 444 “Full” 3 = HDMI RGB 444 “Limited” 4 = HDMI YUV 444 “Full” 5 = HDMI YUV 444 “Limited” 6 = HDMI YUV 422 “Full” 7 = HDMI YUV 422 “Limited”
0 = off (default) 1 = crop 2 = alternating pixels 3 = crosshatch 4 = colorbars 5 = greyscale
0 = auto (default) 1 = 8 bit
See the table on page 22.
View the current test pattern.
Set the video bit depth.
View the video bit depth.
Freeze the selected input.
Unfreeze the selected input.
View the freeze status.
XTP SR HDMI Scaling Receiver • SIS Configuration and Control 25
Command ASCII Command
(host to XTP)
Screen saver
Set timeout duration
View timeout duration
EX1#SSAV} SsavX1#*X1%]
ESSAV} SsavX1#*X1%]

Audio Configuration Commands

Audio mute
Mute all
Mute S/PDIF and analog
Mute S/PDIF and HDMI
Mute S/PDIF
Mute analog and HDMI
Mute analog audio
Mute HDMI audio
Unmute all
View mute status
Volume
Set volume
Increase volume level
Decrease volume level
View volume level
7Z
6Z
5Z
4Z
3Z
2Z
1Z
0Z
Z
X1&V VolX1&] Set output volume to X1&.
+V
-V
V

Preset Commands

User presets
Recall preset
Save preset
X1*. RprX1*] Recall user preset X1*. X1*, SprX1*]
Response
(XTP to host)
]
Amt7
]
Amt6
]
Amt5
]
Amt4
]
Amt3
]
Amt2
]
Amt1
]
Amt0
X1^]
Amt
X1&]
Vol
X1&]
Vol
X1&]
Vol
Additional Description
Set the required duration of inactivity before the screen saver activates.
View the required duration of inactivity before the screen saver activates and how much time is left before it activates.
Mutes all audio outputs.
Mutes S/PDIF and analog audio outputs.
Mutes S/PDIF and HDMI audio outputs.
Mutes S/PDIF audio output.
Mute analog and HDMI audio outputs.
Mute the analog audio output.
Mute the HDMI audio output.
Unmute all audio outputs.
View the audio mute status.
Increase the audio volume.
Decrease audio volume.
View current volume setting.
Save the current settings to user preset
X1*.
NOTES:
X1# = Screen saver timeout duration
X1% = Time in minutes until timeout
X1^ = Audio mute
X1& = Volume X1* = User preset
0 = never time out (default) 1-255 in 1 minute steps
0 = screen saver never times out or the screen saver is
currently enabled
1-255 in 1 minute steps 0 = unmute (default)
1 = mute HDMI audio output 2 = mute analog audio output 3 = mute HDMI and analog audio outputs 4 = mute S/PDIF audio output 5 = mute S/PDIF and HDMI audio outputs 6 = mute S/PDIF and analog audio outputs 7 = mute all audio outputs
0 to 64 (64 = default)
1 to 8
XTP SR HDMI Scaling Receiver • SIS Configuration and Control 26
Command ASCII Command
(host to XTP)

Advanced Configuration Commands

Executive mode
Enable executive mode
Disable executive mode
View executive mode status
Relay control
Pulse relay
Toggle relay
Turn relay on
Turn relay off
View relay status
Aspect ratio
Set aspect ratio to Fill
Set aspect ratio to Follow
View aspect ratio setting
Switch mute
1X
0X
X
X2)*3*X2!O RlyX2)*X!] Pulse relay X2). X2)*2O RlyX2)*X!] Toggle relay X2). X2)*1O RlyX2)*1] Turn relay X2) on. X2)*0O RlyX2)*0] Turn relay X2) off. X2)O Rly X2)* X!]
E1ASPR} Aspr1] E2ASPR} Aspr2]
EASPR} Aspr X2#]
Response
(XTP to host)
]
Exe1
]
Exe0
X!]
Exe
Additional Description
Lock the entire front panel.
Unlock the front panel.
View the executive mode status.
View relay status.
Fill the entire output raster.
Use the native aspect ratio of the input.
View the current aspect ratio setting.
NOTE: The basic mute specifies the mute duration when switching. The advanced mute adds an additional
mute to help compensate for switching between different input resolutions.
Set switch mute
View switch mute setting
NOTES:
X! = Enable or disable
X2) = Relay
X2! = Pulse time X2# = Input aspect ratio
X3@ = Basic mute
X3# = Advanced mute
EX3@*X3#AUTB} Autb X3@*X3#]
EAUTB} Autb X3@*X3#]
0 = disabled or off (default) 1 = enabled or on
1 = relay 1 2 = relay 2
1 to 65535 (in 16 ms steps)
1 = fill (default) 2 = follow
0-255 where 1 step = 100 ms or 10 steps = 1 s
(0 = default)
0-255 where 1 step = 100 ms or 10 steps = 1 s
(0 = default)
Set the mute duration between switching inputs.
View the basic and advanced mute durations between switching inputs.
XTP SR HDMI Scaling Receiver • SIS Configuration and Control 27
Command ASCII Command
(XTP to host)
HDCP mode
Set HDCP mode
View HDCP mode setting
HDCP status
View HDMI output status
Factory defaults
System reset
Information Requests
View input signal status
View firmware version
View firmware build
View part number
NOTES:
ESX3!HDCP} HdcpSX3!] Set the HDCP mode to X3!. ESHDCP} HdcpSX3!]
EOHDCP} HdcpOX2%]
EZXXX} Zpx]
OLS
Q
*Q
N
X2% = HDCP status
X3) = Input signal status
X3! = HDCP mode
Response
(host to XTP)
X3)]
Frq
]
x.xx
x.xx.xxxx
60-1199-01
0, 2, 4, 6 = no sink device detected 1, 3, 5 = sink detected with no HDCP encryption 7 = sink detected with HDCP encryption
0 = no input 1 = input detected
0 = auto or encrypt the output only when required by
the input (default)
1 = always encrypt the output
]
]
Additional Description
View the HDCP mode setting.
Query the HDCP status of the output.
Resets unit to factory default.
View the input signal status.
View the firmware version.
View the firmware build version.
View the device part number.
XTP SR HDMI Scaling Receiver • SIS Configuration and Control 28

XTP System Configuration Software

The XTP System Configuration Software is convenient, user-friendly control software used for configuring an XTP system or individual XTP devices. This section contains installation and configuration procedures for the XTP System Configuration Software. The XTP SR HDMI can also be controlled with the OSD menu (see On-Screen Display Menu
System on page 13) or SIS commands (see SIS Configuration and Control on
page 20). Topics in this section include:
Installing the XTP System Configuration Software
Using the XTP System Configuration Software

Installing the XTP System Configuration Software

The XTP System Configuration Software is available for download on the Extron website,
www.extron.com.
Figure 18. Extron Website Download Page
XTP SR HDMI Scaling Receiver • XTP System Configuration Software 29
1. On the Extron website, click the Download tab (see figure 18, 1).
2. From the left sidebar, click the XTP System Configuration Software link (see
figure 18, 2).
3. Click the Download Now button (see figure 18, 3).
4. Submit any required information to start the download. Note where the file is saved.
5. Open the executable (.exe) file from the location where it was saved.
6. Follow the instructions that appear on the screen. By default, the installation creates a
directory in the appropriate Program Files folder named “Extron Electronics\XTP System Configuration.”

Using the XTP System Configuration Software

The XTP SR HDMI can be controlled directly from the front panel Config port or remotely from a connected XTP matrix switcher.

Connections

When opening the XTP System Configuration Software, the Connections screen opens first. This screen is used to establish communication with an XTP device through a USB connection (see Config port on page 12). Ensure the receiver is connected and powered on before attempting to connect to it.
Figure 19. Connections Screen
1. From the Connections screen in the software, select the USB radio button (see
figure 19, 1).
2. Select the connected device to be controlled from the displayed list (see figure 19, 2).
3. Click the Connect button. The Device Settings screen opens (see figure 19, 3).
XTP SR HDMI Scaling Receiver • XTP System Configuration Software 30

Menu Bar

The menu bar contains three menus for configuring software settings.
File menu
The File menu contains options for disconnecting from the switcher and exiting the program. To access the menu, click the File menu.
Figure 20. File Menu
Disconnect
This option disconnects the connected device from the XTP System Configuration Software.
From the File menu, select Disconnect. The Connections screen opens.
NOTE: If the device is already disconnected, the Disconnect option is disabled until a
device is connected.
Exit
This option disconnects the switcher from the software and closes the application.
From the File menu, select Exit. The application closes.
Tools menu
The Tools menu contains an option for updating firmware. To access this menu, click the
Tools menu.
Figure 21. Tools Menu
NOTE: The Backup and Restore and Software Preference options are not
available when directly connected to the XTP SR HDMI.
XTP SR HDMI Scaling Receiver • XTP System Configuration Software 31
Update Firmware
This option uploads firmware from the host device to the connected device.
NOTE: If necessary, download new firmware form the Extron website (see
Downloading Firmware on page 45).
1. From the Tools menu, select Update Firmware. A dialog box opens to ask permission
to disconnect from the device.
Figure 22. Confirm Disconnect Dialog Box
2. Click the Yes button to disconnect from the device and continue with the firmware
update process. The Update Firmware dialog box opens.
Figure 23. Update Firmware Dialog Box
3. Click the Check network for updates icon to search the LAN or WAN for firmware
files or click the Select file from computer icon to select a firmware file from the connected host device. The Browse dialog box opens.
4. Select the desired firmware file and click the Open button.
5. Click the Close button after the firmware finishes updating.
XTP SR HDMI Scaling Receiver • XTP System Configuration Software 32
Help menu
The Help menu contains a way to access XTP System Configuration Software information, a link to the help file, and a link to the Extron website.
Figure 24. Help Menu
NOTE: The Tutorial (System Configuration) option is not available when directly
connected to the XTP SR HDMI.
About the Software
This option provides basic information about the XTP System Configuration Software, including version number and copyright information.
Figure 25. About - XTP Dialog Box
1. From the Help menu, select About the Software. The About - XTP dialog box
opens.
2. Click the Details button for more information.
3. Click the Ok button to close the dialog box.
Help
This option opens the XTP System Configuration Software help file in a Web browser.
From the Help menu, select Help.
Extron Website
This option opens the Extron website in a Web browser.
From the Help menu, select Extron Website.
XTP SR HDMI Scaling Receiver • XTP System Configuration Software 33

Device Settings

The Device Settings screen allows a user to view and edit various device settings for the receiver directly connected to the PC running the XTP software. Click the Device
Settings
Settings
icon (see figure 26, 1) on the Global Navigation Bar to open the Device screen.
Figure 26. Device Settings Screen
AV Controls panel
The AV Controls panel, located on the left, is used to perform audio or video mutes.
Video mute — Click the Video Mute button to mute or unmute the
2
video output.
Audio mute — Click the Audio Mute button to mute or unmute the
3
audio output.
Audio and video mute — Click the AV Mute button to mute or
4
unmute audio and video output.
NOTE: The mute buttons turn red when they are enabled.
XTP SR HDMI Scaling Receiver • XTP System Configuration Software 34
Input/Output tab
Click the Input/Output tab (see figure 27, 1) to open the Input/Output screen. This screen contains input and output configurations as well as relay controls.
Figure 27. Input/Output Tab
Input panel
The Input panel on the Input/Output screen is used to set the aspect ratio.
Aspect Ratio — From the Aspect Ratio
2
drop-down list, select Fill or Follow.
Fill — Scales the input signal to fill the entire
video output.
Follow — Maintains the signal aspect ratio,
with respect to the current output resolution.
XTP SR HDMI Scaling Receiver • XTP System Configuration Software 35
Output panel
The Output panel on the Input/Output screen is used to set the resolution, refresh rate, and test pattern.
Resolution — From the
3
Resolution drop-down list,
select the desired resolution.
Refresh Rate — From the
4
Refresh Rate drop-down
list, select the desired refresh rate.
Output Format — Sets the
5
output format to a specific setting or to automatically select a format based on the display EDID.
Video Bit Depth — Sets the
6
color bit depth of the output signal.
Test Pattern —From the
7
drop-down list below the test pattern preview, select the desired test pattern (see figure 16 on page 19 for examples of the available test patterns).
Relay Control panel
The Relay Control panel on the Input/Output screen is used to toggle or pulse relay 1 or 2.
Figure 28. Relay Control Panel
Status — Displays whether the relay is open or closed.
8
Toggle — Click the Toggle button in the desired relay panel to toggle either relay open
9
or closed.
Pulse — In the desired relay panel, select a length of time from the Duration field.
-
Click the Pulse button to pulse the relay for the time specified in the Duration field.
XTP SR HDMI Scaling Receiver • XTP System Configuration Software 36
Video tab
Click the Video tab to open the Video screen. This screen contains picture control settings and user preset management options.
Figure 29. Video Tab
Picture Control panel
The Picture Control panel on the Video screen is used to adjust brightness, contrast, and detail settings. Adjust picture control settings in one of the following ways:
Click and drag the handle of the slider for the desired setting.
Click in the desired field to the right of the slider and enter a new value.
Click the Up and Down arrows to the right of the desired setting.
Brightness — Adjust the brightness level of the output.
1
Contrast — Adjust the contrast level of the output.
2
Detail — Adjust the detail level of the output.
3
User Presets panel
User presets save picture control settings that can be recalled later.
Save Preset — Select a preset from the list of presets and click the Save Preset
4
button. Recall Preset — Select the desired preset from the list of presets and click the Recall
5
Preset
button.
XTP SR HDMI Scaling Receiver • XTP System Configuration Software 37
Size and Position tab
Click the Size/Position tab (see figure 30, 1) to open the Size and Position screen. This screen contains several different ways to adjust the size and position of the output.
Figure 30. Size/Position Tab
To adjust the size and position graphically:
If desired, click the Lock Aspect Ratio check box (2) to constrain proportions.
1. Click and drag the drag points of the sample image in the Preview box (3) to resize
the image within the designated space (defined by the black area in figure 30 above).
2. Click anywhere inside the sample image and drag it anywhere within the Preview box.
To adjust the size and position numerically:
1. Enter a value or click the Up and Down arrows in the Horizontal Size and Vertical
Size
fields (4).
2. Enter a value or click the Up and Down arrows in the Horizontal Position and
Vertical Position fields (
To reset all position and size settings:
Click the Image Reset button (5).
4
).
XTP SR HDMI Scaling Receiver • XTP System Configuration Software 38
Audio tab
Click the Audio tab (see figure 31, 1) to open the Audio screen. This screen contains audio output settings.
Figure 31. Audio Tab
Output panel
The Output panel on the Audio screen is used to mute or unmute all audio output and control volume on the analog audio output.
Mute All — Click the Mute All button to mute or unmute all audio output. When
2
muted, the button turns red.
Volume slider — Click and drag the handle of the Volume slider, enter a value in the
3
Volume field, or click the Up and Down arrows to adjust analog audio output volume.
Analog audio for DVI displays Select the check box below the Volume slider to
4
send analog audio to a display receiving DVI signals.
NOTE: When this check box is selected, Extron EDID Minder does not show the
EDID information of the connected display. It shows a 720p Extron EDID.
XTP SR HDMI Scaling Receiver • XTP System Configuration Software 39
General tab
Click the General tab (see figure 32, 1) to open the General screen. This screen contains executive mode and video and sync settings.
Figure 32. General Tab
Executive Mode panel
The Executive Mode panel on the General screen is used to enable or disable front panel lockout mode (executive mode).
Unlock front panel — Click the
2
Unlock Front Panel radio button
(default) to disable executive mode and allow full use of the receiver front panel.
Lock front panel — Click the Lock
3
Front Panel
executive mode and lock the front panel.
NOTE: In executive mode, access to the OSD menu is disabled.
radio button to enable
Mute Video and Sync panel
The Mute Video and Sync panel on the General screen is used to mute or unmute output video and sync.
Mute video and sync — Click the
4
Mute Video and Sync button to
mute the active video and disable sync on the output.
XTP SR HDMI Scaling Receiver • XTP System Configuration Software 40
Screen Saver panel
The Screen Saver panel on the General screen is used to enable or disable a screen saver. When enabled, the output sync is disabled after a specified amount of time.
Never — Click the Never radio
5
button to disable the screen saver setting.
Duration — Enter a value in the
6
After: field, or click the Up and Down arrows to specify a duration
of inactivity before a screen saver is activated. The duration is set in minutes.
HDCP Mode panel
The HDCP Mode panel on the General screen is used to set HDCP encryption of the output signal.
Follow — Click the Follow radio
7
button to set the HDCP encryption of the output signal to follow the input signal setting.
Always Encrypt Output — Click
8
the Always Encrypt Output radio button to always encrypt the output regardless of the encryption status of the input signal.
Switch Mute panel
The Switch Mute panel on the General screen is used to enable or disable mutes during switching.
Basic mute — Select the Enable
9
check box in the Basic Mute panel to mute the output during switching.
If enabled, enter a value in the associated Duration: field, or click the Up and Down arrows to specify a mute duration between switching. The duration is set in 0.5 second increments.
Advanced mute — Select the
-
Enable check box in the Advanced Mute
panel to add an additional mute to help compensate for switching between different input resolutions.
If enabled, enter a value in the associated Duration: field, or click the Up and Down arrows to specify a duration of the additional mute. The duration is set in 0.5 second increments.
Factory Reset
Click the Factory Reset button (see figure 32, =) to reset the receiver to factory settings (except for firmware).
NOTE: This is the same as the E ZXXX SIS command (see the Factory defaults SIS
command on page 28).
XTP SR HDMI Scaling Receiver • XTP System Configuration Software 41
Device Information panel
The Device Information panel displays device information and signal status information.
General Information section
Model — Displays the device model.
1
Firmware Version — Displays the firmware
2
version.
Signal Information section
Input Signal Present — Displays the signal
3
presence. The indicator to the left turns green when there is an input signal present.
Aspect Ratio — Displays the aspect ratio.
4
Resolution — Displays the output resolution
5
and refresh rate.
Output Format Displays the HDMI output
6
format setting.
Video Bit Depth Displays the video bit
7
depth setting.
Audio Information section
HDMI Audio — Displays the mute status of the
8
HDMI audio output.
S/PDIF Audio — Displays the mute status of
9
the audio on the S/PDIF output.
Analog Audio — Displays the mute status of
-
the analog audio output.
Analog Audio Volume — Displays the analog audio output volume level.
=
XTP SR HDMI Scaling Receiver • XTP System Configuration Software 42

Reference Information

This section contains mounting information and updating firmware methods. Topics in this section include:
Mounting
Updating Firmware with Firmware Loader

Mounting

The XTP SR HDMI can be placed on a tabletop or mounted in a rack or underneath a desk.

Tabletop Mounting

Attach the provided rubber feet to the bottom four corners of the enclosure.

Mounting Kits

Mount the unit using any optional compatible rack shelf or mounting kit listed on the Extron website (www.extron.com), in accordance with the directions included with the kit. For rack-mounting, see UL guidelines for rack-mounted devices below.
UL guidelines for rack-mounted devices
The following Underwriters Laboratories (UL) guidelines pertain to the safe installation of the XTP SR HDMI in a rack.
1. Elevated operating ambient temperature — If installed in a closed or multi-unit rack
2. Reduced air flow — Install the equipment in a rack so that the amount of air flow
3. Mechanical loading — Mount the equipment in the rack so that a hazardous
4. Circuit overloading — Connect the equipment to the supply circuit and consider the
5. Reliable earthing (grounding) — Maintain reliable grounding of rack-mounted
assembly, the operating ambient temperature of the rack environment may be greater than room ambient temperature, Therefore, install the XTP SR HDMI in an environment compatible with the maximum ambient temperature (Tma = +122 ˚F, +50 ˚C) specified by Extron.
required for safe operation of the equipment is not compromised.
condition is not achieved due to uneven mechanical loading.
effect that circuit overloading might have an overcurrent protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.
equipment. Pay particular attention to supply connections other than direct connections to the branch circuit (for example, the use of power strips).
XTP SR HDMI Scaling Receiver • Reference Information 43

Updating Firmware with Firmware Loader

To upload and update firmware for the XTP SR HDMI, download the new firmware to a connected computer and upload the firmware with the Extron Firmware Loader utility.

Downloading Extron Firmware Loader

Figure 33. Software on the Extron Website
1. On the Extron website, click the Download tab (see figure 33, 1).
2. From the left sidebar, click the Software link (see figure 33, 2).
Figure 34. Firmware Loader on the Extron Website
3. Click the F link and navigate to Firmware Loader (see figure 34, 3).
4. Click the Download link on the right that corresponds with the program
(see figure 34, 4).
5. Submit any required information to start the download.
XTP SR HDMI Scaling Receiver • Reference Information 44

Installing Firmware Loader

1. Once Firmware Loader has been downloaded, run the .exe file from the location where
the file was saved. The installation window opens.
2. Follow the instructions on the installation screens to install Firmware Loader on the
computer.

Downloading Firmware

Figure 35. Downloading Firmware from the Extron Website
1. On the Extron website, click the Download tab (see figure 35, 1).
2. From the left sidebar, click the Firmware link (2).
3. Navigate to XTP SR HDMI.
4. Ensure the available firmware version is a later version than the current one on the
device.
NOTE: The firmware release notes are a PDF file that provides details about the
changes between different firmware versions. The file can be downloaded from the same page as the firmware.
5. Click the Download link to the right of the desired device.
6. Submit any required information to start the download. Note where the file is saved.
XTP SR HDMI Scaling Receiver • Reference Information 45

Installing Firmware with Firmware Loader

1. Connect the host device to the front panel USB port.
2. Open Firmware Loader and establish a connection between the computer and the
device. The Add Device... dialog box opens.
Figure 36. Add Device... Dialog Box
3. From the Device Name drop-down list, select XTP SR HDMI.
4. From the Connection Method drop-down list, select the method of connection.
5. Depending on the connection method, additional options appear. Make the appropriate
selections for the current connection method.
6. Click the Connect button.
7. Click the Browse button in the New File Firmware (Optional) panel. The Open
dialog box opens.
8. In the Open dialog box, navigate to the location of the new firmware file, select the
desired file.
ATTENTION:
Valid firmware files must have the file extension .S19. A file with any other
extension is not a firmware upgrade for this device and could cause the device to stop functioning.
Les fichiers firmware valides doivent contenir l’extension fichier S19. Un fichier
avec n’importe quelle autre extension n’est pas une mise à jour de firmware pour cet appareil et l’appareil pourrait arrêter de fonctionner.
9. Click the Open button. The Browse dialog box closes.
10. Click the Add button. The Add Device... dialog box closes and the device and
firmware are listed in the Firmware Loader main window.
11. Click the Begin button to start the upload process.
12. Close Firmware Loader when the Remaining Time field shows 00.00.00, the
Progress column shows 100%, and the Status field shows completed.
XTP SR HDMI Scaling Receiver • Reference Information 46

Extron Warranty

Extron Electronics warrants this product against defects in materials and workmanship for a period of three years from the date of purchase. In the event of malfunction during the warranty period attributable directly to faulty workmanship and/or materials, Extron Electronics will, at its option, repair or replace said products or components, to whatever extent it shall deem necessary to restore said product to proper operating condition, provided that it is returned within the warranty period, with proof of purchase and description of malfunction to:
USA, Canada, South America, and Central America:
Extron Electronics 1230 South Lewis Street Anaheim, CA 92805 U.S.A.
Europe and Africa:
Extron Europe Hanzeboulevard 10 3825 PH Amersfoort The Netherlands
Japan:
Extron Electronics, Japan Kyodo Building, 16 Ichibancho Chiyoda-ku, Tokyo 102-0082 Japan
China:
Extron China 686 Ronghua Road Songjiang District Shanghai 201611 China
Asia:
Extron Asia Pte Ltd 135 Joo Seng Road, #04-01 PM Industrial Bldg. Singapore 368363
Middle East:
Extron Middle East Dubai Airport Free Zone F12, PO Box 293666 United Arab Emirates, Dubai
Singapore
This Limited Warranty does not apply if the fault has been caused by misuse, improper handling care, electrical or mechanical abuse, abnormal operating conditions, or if modifications were made to the product that were not authorized by Extron.
NOTE: If a product is defective, please call Extron and ask for an Application Engineer to receive an RA (Return
Authorization) number. This will begin the repair process.
USA: 714.491.1500 or 800.633.9876 Europe: 31.33.453.4040 Asia: 65.6383.4400 Japan: 81.3.3511.7655
Units must be returned insured, with shipping charges prepaid. If not insured, you assume the risk of loss or damage during shipment. Returned units must include the serial number and a description of the problem, as well as the name of the person to contact in case there are any questions.
Extron Electronics makes no further warranties either expressed or implied with respect to the product and its quality, performance, merchantability, or fitness for any particular use. In no event will Extron Electronics be liable for direct, indirect, or consequential damages resulting from any defect in this product even if Extron Electronics has been advised of such damage.
Please note that laws vary from state to state and country to country, and that some provisions of this warranty may not apply to you.
Extron Headquarters
+1.800.633.9876 (Inside USA/Canada Only)
Extron USA - West Extron USA - East +1.714.491.1500 +1.919.850.1000 +1.714.491.1517 FAX +1.919.850.1001 FAX
Extron Europe
+800.3987.6673 (Inside Europe Only)
+31.33.453.4040 +31.33.453.4050 FAX
© 2015 Extron Electronics All rights reserved. www.extron.com
Extron Asia
+65.6383.4400 +65.6383.4664 FAX
Extron Japan
+81.3.3511.7655 +81.3.3511.7656 FAX
Extron China
+86.21.3760.1568 +86.21.3760.1566 FAX
Extron Middle East
+971.4.299.1800 +971.4.299.1880 FAX
Extron Korea
+82.2.3444.1571 +82.2.3444.1575 FAX
Extron India
1800.3070.3777 Inside India Only
+91.80.3055.3777 +91.80.3055.3737 FAX
Loading...