This symbol is intended to alert the user of important operating and maintenance (servicing) instructions in the literature provided with the equipment.
This symbol is intended to alert the user of the presence of uninsulated
dangerous voltage within the product’s enclosure that may present a risk of
electric shock.
Caution
Read Instructions • Read and understand all safety and operating instructions before using the equipment.
Retain Instructions • The safety instructions should be kept for future reference.
Follow Warnings • Follow all warnings and instructions marked on the equipment or in the user information.
Avoid Attachments • Do not use tools or attachments that are not recommended by the equipment
manufacturer because they may be hazardous.
Warning
Power sources • This equipment should be operated only from the power source indicated on the product. This
equipment is intended to be used with a main power system with a grounded (neutral) conductor. The third
(grounding) pin is a safety feature, do not attempt to bypass or disable it.
Power disconnection • To remove power from the equipment safely, remove all power cords from the rear of
the equipment, or the desktop power module (if detachable), or from the power source receptacle (wall plug).
Power cord protection • Power cords should be routed so that they are not likely to be stepped on or pinched
by items placed upon or against them.
Servicing • Refer all servicing to qualified service personnel. There are no user-serviceable parts inside. To prevent
the risk of shock, do not attempt to service this equipment yourself because opening or removing covers may
expose you to dangerous voltage or other hazards.
Slots and openings • If the equipment has slots or holes in the enclosure, these are provided to prevent
overheating of sensitive components inside. These openings must never be blocked by other objects.
Lithium battery • There is a danger of explosion if battery is incorrectly replaced. Replace it only with the
same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the
manufacturer’s instructions.
Consignes de Sécurité • Français
Ce symbole sert à avertir l’utilisateur que la documentation fournie avec le
matériel contient des instructions importantes concernant l’exploitation et la
maintenance (réparation).
Ce symbole sert à avertir l’utilisateur de la présence dans le boîtier
de l’appareil de tensions dangereuses non isolées posant des risques
d’électrocution.
Attention
Lire les instructions• Prendre connaissance de toutes les consignes de sécurité et d’exploitation avant
d’utiliser le matériel.
Conserver les instructions• Ranger les consignes de sécurité afin de pouvoir les consulter à l’avenir.
Respecter les avertissements • Observer tous les avertissements et consignes marqués sur le matériel ou
présentés dans la documentation utilisateur.
Sicherheitsanleitungen • Deutsch
Dieses Symbol soll dem Benutzer in der im Lieferumfang enthaltenen
Dokumentation besonders wichtige Hinweise zur Bedienung und Wartung
(Instandhaltung) geben.
Dieses Symbol soll den Benutzer darauf aufmerksam machen, daß im Inneren
des Gehäuses dieses Produktes gefährliche Spannungen, die nicht isoliert sind
und die einen elektrischen Schock verursachen können, herrschen.
Achtung
Lesen der Anleitungen • Bevor Sie das Gerät zum ersten Mal verwenden, sollten Sie alle Sicherheits-und
Bedienungsanleitungen genau durchlesen und verstehen.
Aufbewahren der Anleitungen • Die Hinweise zur elektrischen Sicherheit des Produktes sollten Sie
aufbewahren, damit Sie im Bedarfsfall darauf zurückgreifen können.
Befolgen der Warnhinweise • Befolgen Sie alle Warnhinweise und Anleitungen auf dem Gerät oder in der
Benutzerdokumentation.
Keine Zusatzgeräte • Verwenden Sie keine Werkzeuge oder Zusatzgeräte, die nicht ausdrücklich vom
Hersteller empfohlen wurden, da diese eine Gefahrenquelle darstellen können.
Instrucciones de seguridad • Español
Este símbolo se utiliza para advertir al usuario sobre instrucciones importantes de operación y mantenimiento (o cambio de partes) que se desean
destacar en el contenido de la documentación suministrada con los equipos.
Este símbolo se utiliza para advertir al usuario sobre la presencia de elementos con voltaje peligroso sin protección aislante, que puedan encontrarse
dentro de la caja o alojamiento del producto, y que puedan representar
riesgo de electrocución.
Precaucion
Leer las instrucciones • Leer y analizar todas las instrucciones de operación y seguridad, antes de usar el
equipo.
Conservar las instrucciones • Conservar las instrucciones de seguridad para futura consulta.
Obedecer las advertencias • Todas las advertencias e instrucciones marcadas en el equipo o en la
Eviter les pièces de xation • Ne pas utiliser de pièces de fixation ni d’outils non recommandés par le fabricant
du matériel car cela risquerait de poser certains dangers.
Avertissement
Alimentations • Ne faire fonctionner ce matériel qu’avec la source d’alimentation indiquée sur l’appareil. Ce
matériel doit être utilisé avec une alimentation principale comportant un fil de terre (neutre). Le troisième
contact (de mise à la terre) constitue un dispositif de sécurité : n’essayez pas de la contourner ni de la
désactiver.
Déconnexion de l’alimentation• Pour mettre le matériel hors tension sans danger, déconnectez tous les
cordons d’alimentation de l’arrière de l’appareil ou du module d’alimentation de bureau (s’il est amovible) ou
encore de la prise secteur.
Protection du cordon d’alimentation • Acheminer les cordons d’alimentation de manière à ce que personne
ne risque de marcher dessus et à ce qu’ils ne soient pas écrasés ou pincés par des objets.
Réparation-maintenance • Faire exécuter toutes les interventions de réparation-maintenance par un
technicien qualifié. Aucun des éléments internes ne peut être réparé par l’utilisateur. Afin d’éviter tout danger
d’électrocution, l’utilisateur ne doit pas essayer de procéder lui-même à ces opérations car l’ouverture ou le
retrait des couvercles risquent de l’exposer à de hautes tensions et autres dangers.
Fentes et orices • Si le boîtier de l’appareil comporte des fentes ou des orifices, ceux-ci servent à empêcher les
composants internes sensibles de surchauffer. Ces ouvertures ne doivent jamais être bloquées par des objets.
Lithium Batterie • Il a danger d’explosion s’ll y a remplacment incorrect de la batterie. Remplacer uniquement
avec une batterie du meme type ou d’un ype equivalent recommande par le constructeur. Mettre au reut les
batteries usagees conformement aux instructions du fabricant.
Vorsicht
Stromquellen • Dieses Gerät sollte nur über die auf dem Produkt angegebene Stromquelle betrieben werden.
Dieses Gerät wurde für eine Verwendung mit einer Hauptstromleitung mit einem geerdeten (neutralen) Leiter
konzipiert. Der dritte Kontakt ist für einen Erdanschluß, und stellt eine Sicherheitsfunktion dar. Diese sollte nicht
umgangen oder außer Betrieb gesetzt werden.
Stromunterbrechung • Um das Gerät auf sichere Weise vom Netz zu trennen, sollten Sie alle Netzkabel aus der
Rückseite des Gerätes, aus der externen Stomversorgung (falls dies möglich ist) oder aus der Wandsteckdose
ziehen.
Schutz des Netzkabels • Netzkabel sollten stets so verlegt werden, daß sie nicht im Weg liegen und niemand
darauf treten kann oder Objekte darauf- oder unmittelbar dagegengestellt werden können.
Wartung • Alle Wartungsmaßnahmen sollten nur von qualiziertem Servicepersonal durchgeführt werden.
Die internen Komponenten des Gerätes sind wartungsfrei. Zur Vermeidung eines elektrischen Schocks
versuchen Sie in keinem Fall, dieses Gerät selbst öffnen, da beim Entfernen der Abdeckungen die Gefahr eines
elektrischen Schlags und/oder andere Gefahren bestehen.
Schlitze und Öffnungen • Wenn das Gerät Schlitze oder Löcher im Gehäuse aufweist, dienen diese zur
Vermeidung einer Überhitzung der empndlichen Teile im Inneren. Diese Öffnungen dürfen niemals von
anderen Objekten blockiert werden.
Litium-Batterie • Explosionsgefahr, falls die Batterie nicht richtig ersetzt wird. Ersetzen Sie verbrauchte Batterien
nur durch den gleichen oder einen vergleichbaren Batterietyp, der auch vom Hersteller empfohlen wird.
Entsorgen Sie verbrauchte Batterien bitte gemäß den Herstelleranweisungen.
Evitar el uso de accesorios • No usar herramientas o accesorios que no sean especificamente recomendados
por el fabricante, ya que podrian implicar riesgos.
Advertencia
Alimentación eléctrica • Este equipo debe conectarse únicamente a la fuente/tipo de alimentación eléctrica
indicada en el mismo. La alimentación eléctrica de este equipo debe provenir de un sistema de distribución
general con conductor neutro a tierra. La tercera pata (puesta a tierra) es una medida de seguridad, no
puentearia ni eliminaria.
Desconexión de alimentación eléctrica • Para desconectar con seguridad la acometida de alimentación
eléctrica al equipo, desenchufar todos los cables de alimentación en el panel trasero del equipo, o desenchufar
el módulo de alimentación (si fuera independiente), o desenchufar el cable del receptáculo de la pared.
Protección del cables de alimentación • Los cables de alimentación eléctrica se deben instalar en lugares
donde no sean pisados ni apretados por objetos que se puedan apoyar sobre ellos.
Reparaciones/mantenimiento • Solicitar siempre los servicios técnicos de personal calicado. En el interior no
hay partes a las que el usuario deba acceder. Para evitar riesgo de electrocución, no intentar personalmente la
reparación/mantenimiento de este equipo, ya que al abrir o extraer las tapas puede quedar expuesto a voltajes
peligrosos u otros riesgos.
Ranuras y aberturas • Si el equipo posee ranuras o orificios en su caja/alojamiento, es para evitar el
sobrecalientamiento de componentes internos sensibles. Estas aberturas nunca se deben obstruir con otros
objetos.
Batería de litio • Existe riesgo de explosión si esta batería se coloca en la posición incorrecta. Cambiar esta
batería únicamente con el mismo tipo (o su equivalente) recomendado por el fabricante. Desachar las baterías
usadas siguiendo las instrucciones del fabricante.
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that the interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
NOTE: This unit was tested with shielded cables on the peripheral devices. Shielded
cables must be used with the unit to ensure compliance.
Conventions Used in this Guide
WARNING: A warning indicates a situation that has the potential to result in death or
severe injury.
ATTENTION: Attention indicates a situation that may damage or destroy the product or
NOTE: A note draws attention to important information.
Specifications Availability
Product specications are available on the Extron website, www.extron.com.
• XPA 1002: 60 watts rms per channel at 8 ohms; 100 watts rms per channel at
4 ohms.
• XPA 2001-70V: 200 watts rms for 70 volt speaker systems.
• XPA 2001-100V: 200 watts rms for 100 volt speaker systems.
Professional grade amplifier design —
• The XPA 1002 features less than 0.05% total harmonic distortion plus noise, and better
than 105 dB signal-to-noise ratio.
• The XPA 2001 features less than 0.1% total harmonic distortion plus noise, and better
than 100 dB signal to noise ratio.
ENERGY STAR® qualified amplifier — The XTRA Series of amplifiers are energy efficient
products that conserve energy and reduce operating costs.
Highly efficient Class D amplifier design — The XTRA Series of amplifiers generate
substantially less heat than conventional amplifier designs, making them ideal for installation
in equipment racks and lecterns with very limited ventilation. They consume 10 watts when
idle and less than 1 watt in standby mode.
Extron patented CDRS™ - Class D ripple suppression — A patented, exclusive
technology from Extron that eliminates the high frequency switching ripple and EMI
emissions found in typical Class D ampliers. CDRS enables Extron power ampliers to be
situated near wireless AV devices without RF interference.
XTRA Series • Introduction1
Page 8
Convection cooled — The XTRA Series of amplifiers are convection cooled without the
need for fans, ensuring quiet, reliable operation.
Ultra low inrush current - no need for power sequencing — Allows many XTRA
Series amplifiers to be powered on simultaneously without overloading power circuits.
This eliminates the need for power sequencing.
Flexible Conduit Adapter Kit, part # 70-228-02 — Suitable for use in other
environmental air space in accordance with section 300.22, (C) of the
National Electrical Code only when used with optional Flexible Conduit Adapter Kit.
Auto-standby with fast power-up — The amplifiers automatically enter into a standby
mode after 25 minutes of inactivity, + or - 5 minutes, dramatically reducing power
consumption. They quickly return to full power status upon signal detection.
Rear panel attenuation (level) controls — Provide attenuation of input signals for
setting proper audio system gain staging as well as two-zone applications. They are
located on the rear panel to prevent unauthorized or accidental tampering of the level
adjustments.
Multiple protection circuits — Activates during excessive clipping, output shorts,
thermal overload, or DC faults to prevent damage to the amplifier and speakers.
Remote standby port — Enables the ampliers to be remotely powered down when not
in use, reducing operating cost.
Remote volume and mute control port — This port allows the amplifiers to be
remotely controlled using the optional Extron VCM 100 Series volume and mute or
VC 50 volume controllers.
Bridgeable outputs — The power output of the XPA 1002 can be effectively doubled
by bridging the output. A mono source is wired to both the left and right input while the
output is wired for bridged operation. Bridging allows power to be output at 200 watts
into 8 ohms. The minimum load impedance when bridging is 8 ohms. See the wiring
instructions beginning on page 19.
Front and rear-mounted signal and protection indication LEDs — Provide convenient
indication of amplifier operation from both sides of an equipment rack.
Internal international power supply — The 100-240 VAC, 50-60 Hz universal power
supply provides worldwide power compatibility.
XTRA Series • Introduction2
Page 9
Installation
This section discusses how to install the XTRA Series of audio power amplifiers.
Topics that are covered, include:
• Application Examples
• Mounting the XPA 1002 and XPA 2001
WARNING: Failure to follow these instructions may result in serious injury.
Application Examples
The following illustrations are application examples for the XPA 1002 and the XPA 2001.
Installation and service must be performed by authorized personnel only.
See “UL Guidelines for Rack Mounting” on page 4.
Extron
IN150 8
Scaling Presentation
Switcher
VCR
Document
Camera
Extron
XPA 100 2
Power
Amplier
3
YC
1
VID
I
Y
N
VID
100-240V 50-60Hz
4
P
U
2
T
DVD Player
2
8Ω / 4Ω OUTPUTS
1
REMOTE
STANDBY
10V 50mA
G
INPUTS
2
CLASS 2 WIRING
1
GCV
21
ATTENUATION
8
10
6
12
4
8
14
2
10
6
2
12
0
4
1
14
XPA 1002
2
∞
18
0
26
∞
SIGNAL
100-240V 0.5A, 50-60Hz
LIMITER/PROTECT
Extron
SI 28
TouchLink
Control
System
VCR
DVD
DOC
CAM
LAPTOP
PC
ON
OFF
DISPLAY
MUTE
SCREEN
UP
SCREEN
DOWN
Surface-mount
Speake rs
TCP/I P
®
100
RELAY
LINK
ACT
31
INPUT
IR
31
42
31
COM
42
TXRX
IPL 250
1
42
2
R
RS-232
3
RS-232
OUTPUT
A
R
B
L
L
6
R
8
45
7
3
AUDIO INPUT
2
1
L
OUTPUT
R
RGB
LISTED
1T23
U S
I.T.E.
Y, B-Y, R-Y
C
6
8
DVI
RGB
7
RGB
R-Y
5
B-Y
Projector
PC
DVI Outpu t
Laptop
PC
Figure 1. XPA 1002 Application Example
XTRA Series • Installation3
Page 10
Extron
MPX 423 A
Media Presentation
Matrix
PC (2)
GlobalViewer
AV Resource
Management and
Remote Control
Application
COMPUTER IN COMPUTER OUT VIDEO INS-VIDEO INOUT
1
100-240V 0.3A
2
50/60 Hz
Extron
XPA 20 01-7 0V
Power
Amplier
11
12
1 9
10
7
2
5
8
6
1
2
3
4
OUT COMPUTER
1
2
Extron
SI 26CT
Two-way Ceiling
Speake rs
70 V OUTPUT
REMOTE
50mA
STANDBY
10V
G
INPUTS
CLASS 2 WIRING
R
(SUMMED)
HPF
L
GCV
ATTENUATION
80 Hz
8
10
6
OFF
12
4
14
2
XPA 2001-70V
18
0
26
∞
SIGNAL
100-240V 0.5A, 50-60Hz
LIMITER/PROTECT
TCP/I P
Network
RS-232
C
O
O
N
VARIBLE
U
T
T
RESETACT
R
R
O
P
I
3
LINK
O
U
L
U
N
L
T
T
R
S-VIDEO
P
4
P
S
R
L
U
3
U
L
T
T
R
R
S
S
4
1
L
L
VIDEO
R
R
2
3
L
L
R
R
4
1
L
L
R
R
2
3
L
L
I
R
R
4
1
N
L
L
P
R
2
U
L
T
S
S-video
Video
VGA
Video
S-video
VGA
Projector
Laptop (2)
Figure 2. XPA 2001 Series Application Example
Mounting the XPA 1002 and XPA 2001
The XPA 1002 and XPA 2001 audio amplifiers can be set on a table, mounted on a rack
shelf, or mounted in the plenum space above a ceiling-mounted projector.
Tabletop Use
Four self-adhesive rubber feet are included with the audio amplifier.
For tabletop use, attach one foot at each corner of the bottom side of the unit and place
the unit in the desired location.
UL Guidelines for Rack Mounting
The following Underwriters Laboratories (UL) guidelines pertain to the installation of the
equipment in a rack.
1. Elevated operating ambient — If installed in a closed or multi-unit rack assembly,
the operating ambient temperature of the rack environment may be greater than
room ambient. Therefore, consider installing the equipment in an environment
compatible with the maximum ambient temperature specified by the manufacturer
[Tma = +32 to +122 °F (0 to +50 °C)].
2. Reduced air flow — Installation of the equipment in a rack should be such that the
amount of air flow required for safe operation of the equipment is not compromised.
Flat Panel Display
DVD (4)
VCR (4)
XTRA Series • Installation4
Page 11
3. Mechanical loading — Mounting of the equipment in the rack should be such that a
4. Circuit overloading — Consideration should be given to the connection of the
5. Reliable earthing (grounding) — Reliable earthing of rack-mounted equipment
Rack Mounting
The XPA 1002 or XPA 2001 can be mounted in a rack shelf using the optional
RSU 129 1U Universal rack shelf (Extron part #60-190-01) or the 1U Basic rack shelf
(Extron part #60-604-02), as follows.
1. If feet were installed on the bottom of the amplifier, remove them.
2. • Place the amplier on one half of the rack shelf.
3. • Attach the amplier to the rack shelf with the two provided 4-40 x 3/16” machine
hazardous condition is not achieved due to uneven mechanical loading.
equipment to the supply circuit and the effect that overloading of the circuits might
have on overcurrent protection and supply wiring. Appropriate consideration of
equipment nameplate ratings should be used when addressing this concern.
should be maintained. Particular attention should be given to supply connections
other than direct connections to the branch circuit (such as the use of power strips).
• Align the front of the amplier with the front of the shelf, and align the threaded
holes on the bottom of the amplifier with the holes in the rack shelf.
screws.
• Insert the screws from the underside of the shelf, and securely fasten them into
diagonally-opposite corners.
See the following illustration.
1U Universal Rack Shelf
1/2 Rack Width Front False
Faceplate
Front false
faceplate
uses 2
screws.
(2) 4-40 x 3/16"
Screws
ATTENTION: Failure to follow these
instructions may result
Use 2 mounting holes on
opposite corners.
in damage to the unit.
Using screws longer than
3/16” will damage the unit
and void the warranty.
Figure 3. Rack Mounting of the Amplifier
4. Attach the false front panel (provided with rack shelf part #60-190-01) to the
unoccupied side of the rack (as shown above), or install a second half-rack-width
device in that side by repeating steps 1 through 3.
5. Attach the rack shelf to the rack using four 10-32 x ¾” bolts (provided). Insert the
bolts through #10 beveled washers, then through the holes in the rack, as shown
above.
XTRA Series • Installation5
Page 12
Rack Mounting Ventilation Recommendations
Excessive heat can decrease the optimal lifetime of the power amplier. An over temp
indicator LED on the front panel of the amplier lights red whenever the recommended
operating temperature has been exceeded. See “Front Panel Features and Operation”
on page 9.
To reduce the chances for an over temp condition, the XPAs should be arranged in a
rack environment so that adequate airflow is available both above and below the XPA
whenever possible. No more than two XPAs should be arranged one-on-top-of-the-other
in a rack without an open space between them, as shown in the following illustration. An
XPA can also be arranged above or below another non-XPA device, but there must be an
open space both above and below those devices.
Vent Space
Vent Space
Vent Space
Vent Space
Vent Space
Vent Space
Figure 4. Allow Sufficient Spacing for Adequate Ventilation
Flexible Conduit Adapter Kit Installation
WARNING: Failure to follow these instructions may result in serious injury.
The circuit breaker used for this connection should be rated no lower
than 20 amps and no greater than 30 amps.
ATTENTION:Failure to follow these instructions may result in damage to the
This unit must be installed in accordance with the National Electrical
Code and with all local codes.
An ALL-POLE MAINS SWITCH with a contact separation of at least
3 mm in each pole shall be incorporated in the electrical installation of
the building. The installation shall be carried out in accordance with all
applicable installation rules.
Installation and service must be performed by a qualified electrician only.
unit.
A UL listed electrical distribution box is recommended for the
termination of the conduit opposite the XPA. See the following
“UL Requirements” section on page 7.
The optional Flexible Conduit Adapter Kit (Extron part #70-228-02) consists of
• One EMT adapter plate
• One 6-foot long electrical conduit
• Three 7.5 feet, 18-gauge spade connector power wires
• One UL rated zip tie wrap
• Three auxiliary crimp style spade connectors designed for 14- to 16-gauge wires
XTRA Series • Installation6
Page 13
NOTE: If needed, Extron recommends using a UL-rated crimp tool to terminate the
spade connectors. One recommended choice is the Molex crimp tool
(Molex part #64001-0100).
The kit provides a convenient means to replace the XPA’s IEC power cord with conduit,
where required by local codes.
WARNING:Failure to follow these instructions may result in serious injury.
Make sure that the source device and the XPA are turned off and
disconnected from the power source before you begin.
UL Requirements
The Underwriters Laboratories (UL) requirements listed below pertain to the installation of
the flexible conduit onto a XPA 1002 or XPA 2001.
• This unit is not to be used beyond its rated voltage range.
• This unit must be wired to a UL listed distribution box.
NOTE: The UL approved electrical distribution box is not included with either the XPA
or the Flexible Conduit Adapter Kit; the installer is responsible for obtaining
and installing the box.
Installing the Flexible Conduit Kit
Install flexible conduit to the XPA by following the steps below.
1. Unplug the IEC power cord from the power amplier.
2. Remove the 8 screws from the top and sides of the XPA and lift off the cover.
See the following illustration.
ATTENTION: Failure to follow these instructions may result in damage to the
unit.
Electrostatic discharge (ESD) can damage IC chips even though you
cannot feel it. You must be electrically grounded before touching
anything inside the XPA. A grounding wrist strap is recommended.
Lift Cover Straight Up
Remove (8)
screws
2
8Ω / 4Ω OUTPUTS
1
REMOTE
STANDBY
10V 50mA
G
INPUTS
2
CLASS 2 WIRING
1
GCV
21
ATTENUATION
8
10
6
12
4
8
14
2
10
6
2
12
0
4
1
14
XPA 1002
2
∞
18
0
26
∞
SIGNAL
100-240V 0.5A, 50-60Hz
LIMITER/PROTECT
Figure 5. Removing the Cover
3. Remove the 2 screws holding the hot (line) and neutral wires from the terminal block
on the PCB.
XTRA Series • Installation7
Page 14
Blue Wire
L
N
Brown Wire
Remove nut
100-240V 1.3A
50-60Hz
Remove screws
(both sides) to release
IEC connector plate.
Figure 6. Removing the IEC Connector
4. Remove the ground wire nut from the grounding stud on the bottom of the
enclosure, as shown above.
5. Remove the 2 screws from the IEC plate, and remove the IEC connector plate and the
attached wires through the rear panel of the XPA, as shown above.
6. Thread the 18-gauge power wires through the length of the electrical conduit tube.
7. Install the EMT adapter plate with conduit attached into the opening from which the
IEC connector was removed in step 5.
8. Slide the conduit nut over the bundle of wires exiting the conduit and onto the
conduit itself. Hand tighten the conduit nut to the conduit.
9. Attach the EMT adapter plate assembly to the XPA using the 2 screws that were
removed in step 5.
10. Connect the black hot (line) and white neutral wires to the terminal block on the
PCB using the 2 screws that were removed in step 3. Use the included zip tie wrap to
secure the two wires together close to the terminals. See the following illustration.
WARNING:Failure to follow these instructions may result in serious injury.
Ensure that you observe correct wire polarity. The following illustration
shows the location of the hot (L) and neutral (N) terminals.
Zip-Tie
LINE
NEUTRAL
EMT Adapter Plate
Te rminal Block
L
N
Conduit Nut
Hot
Te rminal (Black)
Neutral
Te rminal (White)
Ground
Wire Nut
Figure 7. Installing the EMT Adapter Plate Assembly
11. Connect the ground wire, as shown above, to the grounding stud on the bottom of
the enclosure using the nut that was removed in step 4.
12. Replace the cover of the XPA by attaching the 8 screws that were removed in step 2.
XTRA Series • Installation8
Page 15
Operation
This section discusses how to operate the XTRA Series of audio power amplifiers.
Topics that are covered, include:
• Front Panel Features and Operation
• Rear Panel Features and Operation
Front Panel Features and Operation
32
12
OVER
1
XPA 1002
Front Panel
TEMP
LIMITER/PROTECT
SIGNAL
4
XPA 1002
32
OVER
TEMP
1
XPA 2001-70V,
XPA 2001-100V
Front Panel
Power indicator LED — This LED lights:
a
LIMITER/PROTECT
SIGNAL
4
XPA 2001
• Green when the amplier is receiving full power.
• Amber when the amplifier is in Standby mode. Standby mode turns off all outputs
from the amplifier, although the amplifier is still receiving power.
See f of “Rear Panel Features and Operation” on page 13.
Over Temp indicator LED — This LED lights red when the amplier exceeds the
b
recommended operating temperature for optimal lifetime. The LED will turn off after
the amplifier has cooled down sufficiently.
Should the LED light, check the following:
• Verify that the placement of the amplier allows for adequate ventilation and
airflow.
• Avoid placing other equipment on top of the amplifier.
• Verify that the operating temperature is within the specied range.
XTRA Series • Operation9
Page 16
Limiter/Protect indicator LEDs (channels 1 and 2) — These LEDs (representing
c
output channels 1 and 2) light red under three circumstances:
12
LIMITER/PROTECT
• When the output wiring is shorted together
• When audio clipping occurs, the corresponding channel’s LED blinks once per clip
occurrence.
• When the amplier overheats, both LEDs are lit. The LEDs are not lit after the
amplifier recovers from the overheated condition.
NOTE: These LEDs are also located on the rear panel.
Signal indicator LEDs (channels 1 and 2) — These LEDs (representing input
d
channels 1 and 2) light green only when an input signal is detected on the
corresponding channel.
12
SIGNAL
NOTE: These LEDs are also located on the rear panel.
XTRA Series • Operation10
Page 17
Rear Panel Features and Operation
2
1
XPA 1002
Rear Panel
100-240V 0.5A, 50-60Hz
1
XPA 2001-70V
Rear Panel
100-240V 0.5A, 50-60Hz
1
XPA 2001-100V
Rear Panel
LIMITER/PROTECT
SIGNAL
XPA 2001-70V
LIMITER/PROTECT
SIGNAL
XPA 2001-100V
LIMITER/PROTECT
SIGNAL
2
1
ATTENUATION
1
10
12
12
8
14
14
6
4
2
0
2
10
8
6
4
2
0
INPUTS
1
REMOTE
8Ω/4Ω OUTPUTS
50mA
10V
2
G
STANDBY
G
C
V
CLASS 2 WIRING
345a67a
2
ATTENUATION HPF
10
12
14
18
26
∞
34
INPUTS
10V
L
(SUMMED)
8
6
80 Hz
4
2
OFF
0
R
5b8
REMOTE
50mA
70 V OUTPUT
G
STANDBY
GCV
CLASS 2 WIRING
6
2
ATTENUATION HPF
12
14
18
26
∞
34
INPUTS
L (SUMMED)
10
8
6
80 Hz
4
2
OFF
0
R
5b8
10V
REMOTE
50mA
6
100 V OUTPUT
G
STANDBY
GCV
CLASS 2 WIRING
7b
7b
2
1
NOTE: Control signal ground pins may be labeled as or “G”. Audio ground
pins may be labeled as or .
The wiring and function are the same, whichever way your product is
labeled.
AC power connector — Connect a standard IEC AC power cord here for power
a
input (100 VAC to 240 VAC, 50/60 Hz) to the internal, autoswitching power supply.
This connector may be replaced by the Flexible Conduit Adapter Kit
(part #70-228-02) as described in “Flexible Conduit Adapter Kit Installation” on
page 6.
Limiter/Protect indicator LEDs — These LEDs light red under certain circumstances.
b
NOTE: See c of “Front Panel Features and Operation” on page 10 for more
details.
Signal indicator LEDs — These LEDs light green only when an input signal is
c
detected on the corresponding channel.
NOTE: See d of “Front Panel Features and Operation” on page 10 for more
details.
XTRA Series • Operation11
Page 18
Attenuation (channels 1 and 2) — Use a small screwdriver to adjust the audio input
d
level for the corresponding channel. The analog potentiometers control the level from
(full attenuation) to 0 dB.
=
NOTES:• On the XPA 2001, the single control adjusts the levels of both channels
simultaneously prior to summing them together.
• On some models, this adjustment is referred to as “level”. The function
is the same, whichever way your product is labeled.
To adjust the input level of the XPA amplifier, do the following:
1. If connecting to a source device with a volume control (variable output), ensure
that the volume on the source device is set to its lowest point, then adjust the
level of the XPA fully counterclockwise.
2. Set the source device’s volume to its maximum volume level. No sound should
come out.
3. Return to the XPA amplifier and raise the level until sound distortion occurs, then
lower the level slightly until any distortion disappears. This setting ensures that,
whatever the source device volume setting may be, no clipping occurs.
NOTE: When setting volume control through a source device, ensure that the
volume of the device is set to variable out. Consult the user manual of
the device for detailed instructions on its calibration.
Balanced or unbalanced stereo or mono audio input connector (XPA 1002) —
à
Wire the 3.5 mm 5-pin captive screw connector for balanced or unbalanced input.
Tip
Sleeve
Tip
Sleeve
Unbalanced Stereo Input
LR
Sleeves
Tip
Ring
Tip
Ring
Balanced Stereo Input
LR
Tip
Sleeve
Unbalanced Mono Input
LR
Tip
Ring
Sleeve
LR
Balanced Mono Input
Do not tin the wires!
NOTE: The input connector port may be labeled
one of two ways. The wiring and function
are the same, whichever way your product
INPUTS
1
2
or
INPUTS
1
2
is labeled.
NOTE: The output power of the XPA 1002 can be effectively doubled by using only
one input channel and bridging the output. The XPA 1002 will output
200 watts @ 8 ohms in bridged mode. See “Bridged Mono Output” on
page 19 for wiring instructions when bridging the XPA 1002.
XTRA Series • Operation12
Page 19
Balanced or unbalanced stereo or mono audio input connector(XPA 2001) —
â
Wire the 3.5 mm 5-pin captive screw connector for balanced or unbalanced input.
Tip
Sleeve
Tip
Sleeve
Unbalanced Stereo Input
LR
Tip
Ring
Sleeves
Tip
Ring
Balanced Stereo Input
LR
Tip
Sleeve
Do not tin the wires!
NOTE: The input connector port may be labeled
one of two ways. The wiring and function
are the same, whichever way your product
Unbalanced Mono Input
INPUTS
L
(SUMMED)
R
LR
Tip
Ring
Sleeve
L(MONO)
or
Balanced Mono Input
INPUTS
R
is labeled.
NOTE: For mono input on the XPA 2001, because the left and right channels are
summed, only the left channel needs to be wired. No jumpering to the right
channel is needed.
Remote control connector — The 3.5 mm 5-pin captive screw receptacle is used
f
to remotely control two functions through contact closure: See the following circuit
diagram.
NOTE: The remote control port may be labeled one of two ways (see the
following images). The wiring and function are the same, whichever way
your product is labeled.
LR
Pins V, C, and G (1, 2, and 3) control volume by varying the DC voltage from 0 V
(full attenuation) to 10 V (maximum volume) with full muting in effect when pin C is
connected to ground (pin G). Use the included 3-pin captive screw connector.
See “Remote Volume Control” on page 17.
10V50 mA
123
or
MUTE SWITCH
VOL/MUTE
STANDBY
1 V
2 C
3
45
MUTE
VOLUME
G
MAX
10K OHMS
MIN
REMOTE
10V
V
2K OHMS
50mA
GC
G
STANDBY
XTRA Series • Operation13
Page 20
• Pin 5 connected to ground (pin 4) places the amplifier in standby mode. Standby
mode turns off all output, although the amplier is still receiving power. Use the
included 2-pin, 3.5 mm captive screw connector to remotely ground pin 5.
The power indicator LED lights amber when the amplier is in standby mode.
REMOTE
50mA
10V
G
STANDBY
V
GC
or
10V50 mA
VOL/MUTE
123 45
STANDBY
Stereo audio output connector (channels 1 and 2) — Marked “1” and “2”
å
Remote Switching to Standby Mode
10V
V
50mA
GC
G
STANDBY
for the output channels, wire the included 4-pole, 5 mm screw lock captive screw
connector to output stereo audio. Observe the correct polarities for each channel.
See the following steps. The output is designed to power 4 or 8 ohm speakers and is
rated at 100 watts per channel at 4 ohms and 60 watts per channel at 8 ohms.
NOTES:• You must use Class 2 wiring for this output to comply with UL
requirements.
• The stereo audio output connector may be labeled one of two ways
(see the images below). The wiring and function are the same,
whichever way your product is labeled.
8Ω/4Ω OUTPUTS
2
1
CLASS 2 WIRING
or
XPA 1002
OUTPUT
12
ATTENTION: Failure to follow these instructions may result in damage to
the unit.
Do not tie channel outputs 1 and 2 to each other or to ground.
Doing so will short out the outputs and/or damage the amplifier.
NOTE: The output power of the XPA 1002 can be effectively doubled by using
only one input channel and bridging the output. The XPA 1002 will output
200 watts at 8 ohms in bridged mode. See “Bridged Mono Output” on
page 19 for wiring instructions when bridging the XPA 1002.
XTRA Series • Operation14
Page 21
To wire the stereo audio output connector:
Step 1: Strip and insert the speaker wires into the connector and tighten the
captive screws. Be sure to observe the correct polarity.
Do not tin the wires!
Step 2: Insert the wired connector into the amplifier output and secure the locking
screws on either side.
2
8Ω / 4Ω OUTPUTS
1
CLASS 2 WIRING
Mono audio output connector — Marked “+” and “-”, wire the included 2-pole,
ç
5 mm screw lock captive screw connector for mono audio. See the following steps on
the next page. Output is designed to power 70 V (XPA 2001-70V) or
100 V (XPA 2001-100V) line distribution systems and is rated at 200 watts.
NOTES:•You must use Class 2 wiring for this output to comply with UL
requirements.
• The mono audio output connector may be labeled one of two ways
(see the images below). The wiring and function are the same,
whichever way your product is labeled.
70 V OUTPUT
CLASS 2 WIRING
XPA 2001-70V
OUTPUT
70V
oror
100 V OUTPUT
CLASS 2 WIRING
XPA 2001-100V
OUTPUT
100V
ATTENTION: Failure to follow these instructions may result in damage to
the unit.
Do not tie channel outputs 1 and 2 to each other or to ground.
Doing so will short out the outputs and/or damage the amplifier.
XTRA Series • Operation15
Page 22
To wire the mono audio output connector:
Step 1: Strip and insert the speaker wires into the connector and tighten the
captive screws. Be sure to observe the correct polarity.
Do not tin the wires!
Step 2: Insert the wired connector into the amplifier output and secure the locking
screws on either side.
70 V OUTPUT
CLASS 2 WIRING
High pass filter toggle switch — Use a small screwdriver to toggle this recessed
h
two-position toggle switch that alternates between Off (no ltering) and 80 Hz
(default). Setting the switch to 80 Hz prevents the saturation of 70 V/100 V speaker
input transformers by low frequency signals. Saturation can result in severe distortion
of the speaker output signal.
NOTES:• The high-pass filter may be safely turned off if it is applied to the source
input signal upstream of the amplifier. Otherwise, it should be left on.
• The high-pass filter toggle switch may be labeled one of two ways.
The wiring and function are the same, whichever way your product is
labeled.
XTRA Series • Operation16
Page 23
Remote Volume Control
Options for remote control of the XPA ampliers include the Extron VCM 100 and
VC 50 volume controllers. Third party 10k potentiometer volume controllers can also be
connected to this port.
As shown in the following illustration, pin V (1) on the XPA is a 10 VDC reference voltage.
Pin C (2) is the volume control DC voltage input. The range is 0 to 10 V, where 0 V is mute
and 10 V provides maximum volume. Pin G (3) is ground.
NOTE: All nominal levels are at ±10%.
REMOTE
50mA
10V
G
STANDBY
V
or
GC
10V50 mA
VOL/MUTE
Red
Black
Ground
Extron
STP 22
Cable
10V
VOL/
MUTE
VOLUME
1234 5
MUTE
STANDBY
VCM 100
Figure 8. Pinout Diagram for VCM 100 MAAP Connection to XPA Remote
Connector
XTRA Series • Operation17
Page 24
Controlling Multiple Amplifiers with One Volume Controller
Several XPA 1002 and XPA 2001 units can be daisy-chained so that one volume controller
can simultaneously regulate the volume of all the amplifiers.
NOTES:• As additional amplifiers are added to the daisy chain, the sensitivity of
the volume potentiometer will change. The maximum volume level (fully
clockwise) will not be affected. However, the effectiveness of the minimum
volume level (fully counterclockwise) in reducing the volume to inaudible
levels decreases as more amplifiers are added to the daisy chain.
• When more than two XPA Half-Rack units are attached to the chain, sound
may be heard even if the levels have been set to their lowest. The muting
of the output, however, can be remedied with a contact closure button
attached between the Vol/Mute and the Ground pin of the rst
XPA Half-Rack unit in the chain.
To regulate multiple amplifiers with a single volume controller:
1. Attach all three pins of the volume controller to the corresponding pins on the first
XPA Half-Rack unit only — Ground to G (ground), Vol/Mute to C (Vol/Mute),
and 10 V to V (10 V).
2. Use jumper wires to connect the C (Vol/Mute) pins of the rst amplier and each
successive amplifier.
3. Use jumper wires to connect the G (ground) pins of the rst amplier and each
successive amplifier.
Extron
VCM 100 AAP
10V
VOL/
MUTE
REMOTE
10V
50mA
G
STANDBY
Extron
XPA Half-Rack
daisy chain
REMOTE
50mA
10V
REMOTE
50mA
10V
G
STANDBY
G
STANDBY
V
GC
10V50 mA
VOL/MUTE
1234 5
STANDBY
V
GC
10V50 mA
VOL/MUTE
1234 5
STANDBY
V
GC
10V50 mA
VOL/MUTE
1234 5
STANDBY
or
Figure 9. Regulating Multiple Amplifiers with a Single Volume Controller
NOTE: The 10 V pin of the volume controller connects to the rst XPA Half-Rack
unit only. There are no jumper wires linking it to subsequent amplifiers.
XTRA Series • Operation18
Page 25
Bridged Mono Output
The power output of the XPA 1002 can be effectively doubled by bridging the output.
Bridging allows power to be output in mono at 200 watts at 8 ohms.
NOTES: • The bridging instructions that follow apply only to the XPA 1002 model.
• The minimum load impedance when bridging is 8 ohms.
To bridge the output, follow the steps and refer to the diagram below:
1. Unplug the IEC power cord from the power amplier.
2. Fully attenuate the potentiometer.
3. Wire the output as shown in the following diagram.
4. Wire the input as shown in the following diagram.
5. Connect the IEC power cord and power up the amplier.
6. Adjust the input levels of channels 1 and 2 identically.
See d (Attenuation) of “Rear Panel Features and Operation” on page 12 for more
details.
100-240V x.yAMAX, 50-60Hz
Balanced Wiring
From
Mono
Source
Un-Balanced Wiring
From
Mono
Source
XPA 1002
2
LIMITER/PROTECT
Levels should be set
identically.
Captive Screw
1
SIGNAL
3.5 mm
1
2
1
2
5 mm
Captive Screw
ATTENUATION
1
10
12
12
8
14
14
6
4
2
0
REMOTE
INPUTS
2
10
8
0
2
1
6
4
2
Input
8Ω/4Ω OUTPUTS
50mA
10V
G
C
V
G
STANDBY
1
CLASS 2 WIRING
2
Amplified
Output
1
To 8 Ohm Minimum
Speaker Load
2
NOTE: During bridged mono output, the + output
from output channel 1 becomes the positive
terminal and the + output from channel 2
becomes the negative terminal
Figure 10. Bridging the Output of the XPA 1002
XTRA Series • Operation19
Page 26
Troubleshooting
The front and rear panels have LED warning indicators, as described in the following
diagnostic information.
Amplifier Fails to Exit Standby Mode Promptly
The input channel (channels 1 and 2) Signal LED lights green per indicated input channel
when an input signal is detected.
Power LED
Color
AmberNot litNo output signalNo input detected, verify the
Green or
Amber
AmberLitNo output signalAmplifier has been placed in
AmberLitDC Fault is detected
Signal LED
State
Lit
intermittently
Problem Description Problem Solution
input signal.
If input is present, raise input
level until signal LED lights.
Slow to promptly exit
standby mode with
signal present.
on either channel. Unit
does not exit standby.
The output signal level of the
source may be too low to cross
the signal detection threshold
of the amplifier (see amplifier
specifications for details).
Increase the signal level of the
source until the signal LED
lights consistently.
standby mode and output has
been turned off. Check remote
port. DC fault may have been
detected (see below).
Disconnect power then
disconnect the remote port (if
connected). Next, reconnect
power to the unit to determine
if the unit continues to go
into immediate standby upon
power up. In such a case, the
unit should be serviced.
Amplifier Enters Standby Mode Too Early
The input channel (channels 1 and 2) Signal LED lights green per indicated input channel
when an input signal is detected.
Power LED
Color
Green or
Amber
Signal LED
State
Lit
intermittently
Problem
Description
Enters standby mode
early.
Problem Solution
The output signal level of the
source may be too low to cross
the signal detection threshold
of the amplifier (see amplifier
specifications for details).
Increase the signal level of the
source until the signal LED lights
consistently.
XTRA Series • Troubleshooting20
Page 27
Limiter/Protect LED Warning Indicators
The output channel (channels 1 and 2) Limiter/Protect LED lights red per indicated output
channel as shown in the following diagnostic information.
LED StateProblem DescriptionProblem Solution
BlinksAudio clipping is occurring at the
rate of one blink per clip.
Lights steady The amplifier may be overheating.Determine the reason for the
Output channel leads are shortedCheck speakers and speaker
Reduce the power output to
avoid overdriving the amplifier
and causing clipping.
overheated state and allow the
amplier to cool. The LED will not
be lit after the amplifier recovers
from the overheated state.
wiring for shorts.
Over Temp Indicator LED
This indicator does not represent a hard failure of the unit. It is meant as a warning that
the amplifier has exceeded the recommended operating temperature for optional product
lifetime.
LED StateProblem DescriptionProblem Solution
Lights steady Amplifier has exceeded the
recommended operating
temperature. The LED turns off
after the amplifier cools down
sufficiently.
• Verify that the placement of the
amplifier allows for adequate
ventilation and airflow.
• Avoid placing equipment on top
of the amplifier.
• Verify that the operating
temperature is within the
specified range.
XTRA Series • Troubleshooting21
Page 28
References
This section discusses the part numbers and accessories for the XTRA Series of half-rack
audio power amplifiers.
Part Numbers and Accessories
Included parts
Included partsReplacement
XPA 1002 two-channel power amplifier60-849-01
or
XPA 2001-70V single-channel power amplier60-850-01
or
XPA 2001-100V single-channel power amplier60-850-11
(1) 4-pole screw lock 5.08 mm captive screw plug
(1) 5-pole 3.5 mm captive screw plug100-457-01
(1) 3-pole 3.5 mm captive screw plug100-456-01
(1) 2-pole 3.5 mm captive screw plug100-455-01
(4) rubber feet (detached)
IEC power cord
Setup Guide
part number
100-464-01
100-463-01
Optional Accessories
AccessoriesPart number
RSU 129 9.5" deep 1U universal rack shelf kit60-190-01
RSB 129 9.5" deep 1U basic rack shelf60-604-02
MLA VC10 Plus volume control module60-1090-01
VCM 100 AAP volume and mute control70-396-11, -21
VCM 100 MAAP volume and mute control
VC 50 volume control wall plate70-530-02
Flexible conduit adapter kit70-228-02
70-397-11, -21,
-51
XTRA Series • References22
Page 29
Extron Warranty
Extron Electronics warrants this product against defects in materials and workmanship for a period of three years
from the date of purchase. In the event of malfunction during the warranty period attributable directly to faulty
workmanship and/or materials, Extron Electronics will, at its option, repair or replace said products or components,
to whatever extent it shall deem necessary to restore said product to proper operating condition, provided that it is
returned within the warranty period, with proof of purchase and description of malfunction to:
USA, Canada, South America,
and Central America:
Extron Electronics
1001 East Ball Road
Anaheim, CA 92805
U.S.A.
Europe and Africa:
Extron Europe
Hanzeboulevard 10
3825 PH Amersfoort
The Netherlands
Japan:
Extron Electronics, Japan
Kyodo Building, 16 Ichibancho
Chiyoda-ku, Tokyo 102-0082
Japan
China:
Extron China
686 Ronghua Road
Songjiang District
Shanghai 201611
China
Asia:
Extron Asia
135 Joo Seng Road, #04-01
PM Industrial Bldg.
Singapore 368363
Middle East:
Extron Middle East
Dubai Airport Free Zone
F12, PO Box 293666
United Arab Emirates, Dubai
Singapore
This Limited Warranty does not apply if the fault has been caused by misuse, improper handling care, electrical or
mechanical abuse, abnormal operating conditions, or if modifications were made to the product that were not
authorized by Extron.
NOTE: If a product is defective, please call Extron and ask for an Application Engineer to receive an RA (Return
Authorization) number. This will begin the repair process.
USA: 714.491.1500 or 800.633.9876 Europe: 31.33.453.4040
Asia: 65.6383.4400 Japan: 81.3.3511.7655
Units must be returned insured, with shipping charges prepaid. If not insured, you assume the risk of loss or damage
during shipment. Returned units must include the serial number and a description of the problem, as well as the
name of the person to contact in case there are any questions.
Extron Electronics makes no further warranties either expressed or implied with respect to the product and its quality,
performance, merchantability, or tness for any particular use. In no event will Extron Electronics be liable for direct,
indirect, or consequential damages resulting from any defect in this product even if Extron Electronics has been
advised of such damage.
Please note that laws vary from state to state and country to country, and that some provisions of this warranty may
not apply to you.
Extron Headquarters
+1.800.633.9876 (Inside USA/Canada Only)
Extron USA - West Extron USA - East