Overview
The Extron® TLP 350MV is a wall-mounted TouchLink™ Panel that
provides simple and versatile configuration and control for a range
of IP Link® control systems.
Graphic and text objects are displayed on the screen. These objects
have system control functions associated with them and the
Touchpanel allows you to control those functions.
Two BNC connectors allow the screen to be used to preview composite video or S-video.
NOTE: The RJ-45 output on the rear panel of the TLP 350MV must be connected to a network switch, hub, or router that
is connected to an Ethernet LAN or the Internet. An Extron IP Link controller must also be connected to the same
network. Suggested models include IPL T S series (for example, IPL T S4), IPL 250, IPL T CR48, or IPL T SFI244 .
This guide provides basic instructions for experienced installers to mount and perform initial configuration on the
TLP 350MV. Full instructions and reference material can be found in the TLP 350MV User Guide, which is available on the
Extron Web site (www.extron.com).
TLP 350MV Front Panel Features
1
2
3
4
5
6
Figure 1. TLP 350MV Front Panel (left) and Front Panel with Bezel Removed to Show Recessed Buttons (right).
Light sensor — monitors the level of ambient light and adjusts the screen brightness and button backlighting.
a
3.5 inch LCD screen — provides a graphical user interface with a pressable touch screen display.
b
Speaker — provides audible feedback.
c
Motion detector — detects movement in front of the panel. When no motion has been detected for a user-defined
d
period of time, the unit goes into sleep mode, which shuts down the screen display and inactivates all the buttons.
When motion is detected, these functions are restored.
Eight backlit push-buttons — can be configured to perform user-defined functions, using the Extron Global
e
Configurator software.
Encoder knob — intended for volume control but it can be configured for other functions.
f
Two buttons and an LED are recessed behind the bezel. Remove the bezel using the
Extron removal tool inserted into the tabs on the bottom of the panel, as shown in the
figure at right.
Menu button — activates the on screen menus for calibrating and setting the unit.
g
Reset button — allows the unit to be reset in any of four different modes. See the
h
"Reset Modes" section on the back page of this setup guide.
Reset LED — is visible only when the faceplate has been removed. It lights as an
i
indicator for the reset modes.
Remove Bezel
at Tabs
Extron
Extron
Extron Removal Tool
7
8
9
TLP 350MV • Setup Guide (Continued)
Mounting the TLP 350MV
Decide where to mount the TLP 350MV and whether to use a 3-gang mud ring or a 3-gang UL-certified junction box. The
mounting instructions are slightly different depending on your choice:
Using a Mud Ring
1. Use the template provided with the mud ring to mark
the wall. For the mud ring provided, the hole must be
5 25/32 inches (14.68 cm) wide x 3 7/8 inches (9.83 cm) high.
Locking Arms (4)
4
2. Cut a hole in the wall. To avoid making the hole too big, cut
inside the lines you marked.
3. Test the fit by inserting the mud ring into the hole in the wall.
If necessary, use a rasp or file to enlarge the hole.
4. Insert the mud ring into the hole and use a screw driver to
turn and tighten the locking arms until they clamp the mud
ring to the mounting surface. Do not overtighten.
5. Secure the wall adapter (provided) to the junction box, using
the four screws (provided).
6. Use the Extron removal tool provided to separate the bezel
from the TLP 350MV (see figure on previous page).
Mud Ring
TLP 350MV
7. Extron recommends using the provided Power over Ethernet (PoE) power
supply. Connect a network switch to the "LAN In" port and run a second cable
from the "Pwr LAN Out" port to the Touch Panel mounting site (see the figure below).
Bezel
CAUTION: Whether you use a PoE power supply or a 12 VDC power supply (not provided), you must read the
caution in the Power Supply section of the TLP 350MV User Guide.
NOTE: If both a PoE power supply and a 12 VDC power supply are present, the unit will draw power from the PoE
power supply only.
Clips (4)
9
Screws (2)
DISPLAY ON
DISPLAY OFF
LAPTOP
MUTE
PC
DVD
DOC CAM
AUXILIARY
8. Run video cables with to the mounting site. Leave enough slack in the cables to connect them to the TLP 350MV. Pull
the cables through the mud ring. Connect the cables as shown in the diagram below.
9. Plug the cables into the rear panel connectors of the TLP 350MV (refer the TLP 350MV User Guide).
10. Secure the TLP 350MV to the mud ring using the two screws provided (top center and bottom center).
11. Do not replace the bezel at this time. You will need access to the recessed Menu and Reset buttons to configure the
unit.
C (yellow cable) Video/Y (white cable)
Power over Ethernet (PoE) Power Supply
PWR LAN-OUT LAN-IN
To Network SwitchTo TLP 350MV