Extron electronic SMB 205 L User Manual

Rear
Mounting Nuts
AAPs (not included)
Optional Split AAP
Mark pilot holes for keyhole slot (1/16”) or mounting hole (1/16”).
Mark pilot holes for keyhole slot (1/16”) or mounting hole (1/16”).
Extron Electronics, USA
1230 South Lewis Street Anaheim, CA 92805
800.633.9876 714.491.1500 FAX 714.491.1517
Extron Electronics, Europe
Beeldschermweg 6C 3821 AH Amersfoort, The Netherlands +800.3987.6673 +31.33.453.4040 FAX +31.33.453.4050
Extron Electronics, Asia
135 Joo Seng Rd. #04-01 PM Industrial Bldg., Singapore 368363 +800.7339.8766 +65.6383.4400 FAX +65.6383.4664
Extron Electronics, Japan
Kyodo Building, 16 Ichibancho Chiyoda-ku, Tokyo 102-0082 Japan +81.3.3511.7655 FAX +81.3.3511.7656
www.extron.com
Number of accessible AAP openings
SMB 203 L ........................... 1 double-space (back), 1 double-space (bottom)
SMB 205 L ........................... 2 double-space (back), 2 double-space (bottom)
Included blank AAP plates
SMB 203 L ........................... 1 double-space
SMB 205 L ........................... 2 double-space
Furniture mounting holes ............ 4 (2 are slotted)
Cable management lance punches
SMB 203 L ....................................... 2
SMB 205 L ....................................... 3
Front angle ..................................... 36° from vertical, 54° from horizontal
Product weight
SMB 203 L ........................... 1.1 lbs (0.5 kg)
SMB 205 L ........................... 1.6 lbs (0.7 kg)
Shipping weight ............................ 2 lbs (1 kg)
Vibration ........................................ ISTA 1A in carton (International Safe Transit
Association)
Warranty ........................................ 3 years parts and labor
SMB 203 L and SMB 205 L Installation Guide
N For illustration purposes, the following steps use the SMB 205 L as an example, but
the instructions apply to the SMB 203 L as well.
1. For tabletop placement, the four included adhesive rubber feet may be applied to the bottom corners of the mounting base.
2. For angled installations, securely mount the SMB using the two keyhole slots and/or mounting holes in the mounting base.
the mounting holes:
• Position the SMB at the desired location.
• Mark the holes on the surface to be drilled. See the illustration at right.
N
Specifications are subject to change without notice.
Models
Included Parts
Models Part number
SMB 203 L (black, white) 60-942-02, -03
SMB 205 L (black, white) 60-943-02, -03
These items are included in each order of the SMB 203 L or SMB 205 L.
Included parts Replacement
part number
Adhesive rubber feet (4)
70-090-12 (black)
Blank double-spaced AAP (1), SMB 203 L only
or
70-090-22 (white)
70-090-12 (black)
Blank double-spaced AAP (2), SMB 205 L only
70-090-22 (white)
or
68-1497-01 Rev. A
3. Drill 1/16" pilot holes for the keyhole slots or the mounting holes. For the keyhole slots, insert screws into the pilot holes, but do not tighten them down until the SMB is slid into position. For the mounting holes, position the SMB over the holes and secure the SMB into position.
4. Cables may access the SMB through the AAP openings in the rear panel and the bottom mounting base.
If cables are to access the SMB through the rear panel, use the rear panel AAP
openings, as shown here. AAP modules are sold separately.
11 07
SMB 203 L and SMB 205 L Installation GuideSMB 203 L and SMB 205 L Installation Guide
14
If cables are to access the SMB through a hole cut into the mounting surface:
Optional Split AAP
Cable Tie
Pass-through Openings for Cables
Ground Stud
Cable Management Tiedown Points
Front
Mounting Screws
Extron MLC 226 AAP L
Extr
on
PR
OJ
E
C
T
O
R
1
2
3
4
5
6
VO
L
UM
E
CONFI
G
IR
PC
AU
X
V
ID
EO
D
VD
VC
R
DO
C
C
AM
LAPT
OP
AU
T
O
IM
AG
E
M
UTE
ON
O
FF
MediaLink
3.82"
3.60"
6.51"
1.00"
3.20"
36°
3.82"
3.60"
10.00"
1.00"
3.20"
36°
• Mark the pass-through location through the mounting base AAP opening(s).
• Detach the SMB from the mounting surface and cut the opening(s) using an appropriate saw, drill, or other tool.
5. With the SMB fastened to the mounting surface, run all necessary cables through the pass-through opening before installing any device(s) into the SMB. See the following illustration.
N
The SMB has cable management tiedown points for securing the cables into position. There is also a grounding stud for grounding any installed device(s).
Specifications
General
Mounting ........................................ Surface mountable or mountable to furniture
including lecterns and tabletops
Enclosure type .............................. Metal
Enclosure dimensions
SMB 203 L .......................... 3.6" H x 6.5" W x 3.8" D
9.2 cm H x 16.5 cm W x 9.7 cm D
SMB 205 L .......................... 3.6" H x 10.0" W x 3.8" D
9.2 cm H x 25.4 cm W x 9.7 cm D
6. Test all device(s) to be installed with the cables attached prior to fastening them to the SMB.
7. Attach the device to the front of the SMB enclosure.
Faceplate compatibility
SMB 203 L ........................... Mounts a low-profile, 3.2" high, 6.5" wide, L-type
faceplate
SMB 205 L ........................... Mounts a low-profile, 3.2" high, 10.0" wide, L-type
faceplate
N
The SMB 200 Series does not accommodate products with US gang-sized
faceplates; they mount only low-profile, L-type faceplates, including those of the MLC 226 IP L and MLM 104 LAAP.
SMB 203 L and SMB 205 L Installation GuideSMB 203 L and SMB 205 L Installation Guide