Rear
Mounting
Nuts
AAPs
(not included)
Optional Split AAP
Mark pilot holes
for keyhole slot (1/16”)
or mounting hole (1/16”).
Mark pilot holes
for keyhole slot (1/16”)
or mounting hole (1/16”).
Extron Electronics, USA
1230 South Lewis Street
Anaheim, CA 92805
800.633.9876 714.491.1500
FAX 714.491.1517
Extron Electronics, Europe
Beeldschermweg 6C
3821 AH Amersfoort, The Netherlands
+800.3987.6673 +31.33.453.4040
FAX +31.33.453.4050
Extron Electronics, Asia
135 Joo Seng Rd. #04-01
PM Industrial Bldg., Singapore 368363
+800.7339.8766 +65.6383.4400
FAX +65.6383.4664
Extron Electronics, Japan
Kyodo Building, 16 Ichibancho
Chiyoda-ku, Tokyo 102-0082
Japan
+81.3.3511.7655 FAX +81.3.3511.7656
www.extron.com
Number of accessible AAP openings
SMB 203 L ........................... 1 double-space (back), 1 double-space (bottom)
SMB 205 L ........................... 2 double-space (back), 2 double-space (bottom)
Included blank AAP plates
SMB 203 L ........................... 1 double-space
SMB 205 L ........................... 2 double-space
Furniture mounting holes ............ 4 (2 are slotted)
Cable management lance punches
SMB 203 L ....................................... 2
SMB 205 L ....................................... 3
Front angle ..................................... 36° from vertical, 54° from horizontal
Product weight
SMB 203 L ........................... 1.1 lbs (0.5 kg)
SMB 205 L ........................... 1.6 lbs (0.7 kg)
Shipping weight ............................ 2 lbs (1 kg)
Vibration ........................................ ISTA 1A in carton (International Safe Transit
Association)
Warranty ........................................ 3 years parts and labor
SMB 203 L and SMB 205 L Installation Guide
N For illustration purposes, the following steps use the SMB 205 L as an example, but
the instructions apply to the SMB 203 L as well.
1. For tabletop placement, the four included adhesive rubber feet may be applied to
the bottom corners of the mounting base.
2. For angled installations, securely mount the SMB using the two keyhole slots
and/or mounting holes in the mounting base.
Mount the SMB using the keyhole slots and/or
the mounting holes:
• Position the SMB at the
desired location.
• Mark the holes on the
surface to be drilled. See
the illustration at right.
N
Specifications are subject to change without notice.
Models
Included Parts
Models Part number
SMB 203 L (black, white) 60-942-02, -03
SMB 205 L (black, white) 60-943-02, -03
These items are included in each order of the SMB 203 L or SMB 205 L.
Included parts Replacement
part number
Adhesive rubber feet (4)
70-090-12 (black)
Blank double-spaced AAP (1), SMB 203 L only
or
70-090-22 (white)
70-090-12 (black)
Blank double-spaced AAP (2), SMB 205 L only
70-090-22 (white)
or
68-1497-01 Rev. A
3. Drill 1/16" pilot holes for
the keyhole slots or the
mounting holes. For the
keyhole slots, insert screws
into the pilot holes, but
do not tighten them down until the SMB is slid into position. For the mounting
holes, position the SMB over the holes and secure the SMB into position.
4. Cables may access the SMB through the AAP openings in the rear panel and the
bottom mounting base.
If cables are to access the SMB through the rear panel, use the rear panel AAP
openings, as shown here. AAP modules are sold separately.
11 07
SMB 203 L and SMB 205 L Installation GuideSMB 203 L and SMB 205 L Installation Guide
14
If cables are to access the SMB through a hole cut into the mounting surface:
Optional Split AAP
Cable Tie
Pass-through Openings
for Cables
Ground Stud
Cable Management Tiedown Points
Front
Mounting
Screws
Extron
MLC 226 AAP L
Extr
on
PR
OJ
E
C
T
O
R
1
2
3
4
5
6
VO
L
UM
E
CONFI
G
IR
PC
AU
X
V
ID
EO
D
VD
VC
R
DO
C
C
AM
LAPT
OP
AU
T
O
IM
AG
E
M
UTE
ON
O
FF
MediaLink
3.82"
3.60"
6.51"
1.00"
3.20"
36°
3.82"
3.60"
10.00"
1.00"
3.20"
36°
• Mark the pass-through location through the mounting base AAP opening(s).
• Detach the SMB from the mounting surface and cut the opening(s) using an
appropriate saw, drill, or other tool.
5. With the SMB fastened to the mounting surface, run all necessary cables through
the pass-through opening before installing any device(s) into the SMB. See the
following illustration.
N
The SMB has cable management tiedown points for securing the cables
into position. There is also a grounding stud for grounding any installed
device(s).
Specifications
General
Mounting ........................................ Surface mountable or mountable to furniture
including lecterns and tabletops
Enclosure type .............................. Metal
Enclosure dimensions
SMB 203 L .......................... 3.6" H x 6.5" W x 3.8" D
9.2 cm H x 16.5 cm W x 9.7 cm D
SMB 205 L .......................... 3.6" H x 10.0" W x 3.8" D
9.2 cm H x 25.4 cm W x 9.7 cm D
6. Test all device(s) to be installed with the cables attached prior to fastening them to
the SMB.
7. Attach the device to the front of the SMB enclosure.
Faceplate compatibility
SMB 203 L ........................... Mounts a low-profile, 3.2" high, 6.5" wide, L-type
faceplate
SMB 205 L ........................... Mounts a low-profile, 3.2" high, 10.0" wide, L-type
faceplate
N
The SMB 200 Series does not accommodate products with US gang-sized
faceplates; they mount only low-profile, L-type faceplates, including those of
the MLC 226 IP L and MLM 104 LAAP.
SMB 203 L and SMB 205 L Installation GuideSMB 203 L and SMB 205 L Installation Guide
32