Extron electronic PPC-25 User Manual

PPC 25 Installation Instructions
P
W
E
R
CN
P
A
IN
R
E
L
A
Y
D
E
L
A
Y
S
E
N
S
IT
IV
IT
Y
1
2
V
0
.2
A
M
A
X
O
N
1
2
L R
AUX
/M
IX
IN
D
O
N
O
T
G
R
O
U
N
D
O
R
S
H
O
R
T
S
P
E
A
K
E
R
O
U
T
P
U
T
S
!
1B
1A
I N P U T S
O U T P U T S
2B
2A
3B
3A
RS
-232
M
L
C/IR
DC
VO
L
4/8 O
hm
s
AM
PLIFIED O
UTPUTS
V
O
L
/M
U
TE
Tx
AB C
Rx
IR 12V
10V
POW
ER
1
2
V
3
A
M
A
X
U
S
L
I
S
T
E
D
17TT
AUDIO/VID
EO
APP
ARATUS
®
R
G
B
V
ID
E
O R
G
B
V
ID
E
O
Ceiling Mounted Paging Speaker
Paging System
PPC 25
Priority Page Sensor
ClassroomAdmin Building
To Classroom Paging Speakers
Relay Output
Remote Vol/Mute Control
Extron PPC 25
Priority Page Controller
Extron PVS 204SA
Twisted Pair Switcher
Extron SI 26
Surface Mount Speakers
PPC 25
RELAY
7
2
3 4 5 6
1
POWER
CNO
PAGING
SENSOR
OUT
TIME
RELAY
SENSITIVITY
12V
0.5A MAX
ON
1
2
TIME
ON
1
2
= 2.0 sec (default) = 4.0 sec= 6.0 sec= 8.0 sec
PPC 25 Overview
The PPC 25 consists of the Priority Page Controller and Priority Page Sensor. Together they mute classroom audio for the duration of an announcement that is made over a Public Address (PA) system.
The Sensor connects to a PA speaker lead and detects current flow when a PA announcement is initiated.
The Sensor signal triggers the PPC 25 controller’s output relay to close. This relay closure can connect to a PoleVault™ switcher, a Mini Power Amplifier (MPA), a MediaLink™ Controller (MLC), or any device with a contact closure type of mute control or a configurable digital input.
The output relay remains closed until the PA announcement ends. It then opens, dropping the mute signal and restoring the classroom audio.
For a PoleVault System, the output relay should connect only to the PVS 204SA and not the MLC. This requires no software configuration.
If the Output Relay is connected to an MLC digital input, use Global Configurator software to configure the input port, and set the monitoring conditions and actions to drive the desired mute function on the classroom audio device.
The PPC 25 Controller and Sensor are rated for use in plenum environments (any area utilized for air handling, including areas above suspended ceilings and below raised floors). The PPC 25 Sensor assembly must be installed in a UL-compliant junction box with a cover to meet the plenum rating requirement.
A Typical PPC 25 Installation
The PPC 25 works with traditional 25V or 70V and 4/8 ohm PA systems. It was not designed
for, and may not work properly with, systems using digital clocks and two-way intercoms.
Front and Rear Views of the PPC 25 Controller
Power-on LED green when power is on
a
RELAY LED — amber when output relay is closed
b
POWER receptacle — 12 VDC, 33 mA. The unit does not ship
c
with a power supply. Power may be shared with another device. Polarity must be observed.
PAGING SENSOR connector — for the Priority Page Sensor that
d
is located near a PA system speaker
RELAY OUT connector — connects to an amplifier or switcher
e
that has a contact closure type of mute control input, or to an MLC device with a digital input. When a PA system announcement is initiated, the output relay closes and remains closed for the duration of the announcement. The closed output relay triggers the classroom audio mute function. When integrating the PPC 25 into a PoleVault System, connect the output relay to the PVS 204SA Mute and Ground pins only (see diagram on page 2).
TIME switch — sets how long the output relay will remain closed after a PA announcement has ended. A
f
short time delay is necessary so that if the PA system announcer pauses briefly during the announcement, the classroom audio is not restored prematurely. The 2-position DIP switch provides the following time settings:
SENSITIVITY adjustment — sets the sensitivity level for the signal arriving from the Priority
g
Page Sensor. The final setting depends on the type of paging system and the number of wire loops on the Sensor (see page 2). Rotate clockwise to increase sensitivity and counterclockwise to decrease sensitivity.
PPC 25 Priority Page Sensor • Installation Instructions
68-1437-01
Rev F
04 08
1
PPC 25 Installation Instructions, cont’d
Extron Electronics, USA
1230 South Lewis Street Anaheim, CA 92805
800.633.9876 714.491.1500 FAX 714.491.1517
Extron Electronics, Europe
Beeldschermweg 6C 3821 AH Amersfoort, The Netherlands +800.3987.6673 +31.33.453.4040 FAX +31.33.453.4050
Extron Electronics, Japan
Kyodo Building, 16 Ichibancho Chiyoda-ku, Tokyo 102-0082 Japan +81.3.3511.7655 FAX +81.3.3511.7656
Extron Electronics, Asia
135 Joo Seng Rd. #04-01 PM Industrial Bldg., Singapore 368363 +800.7339.8766 +65.6383.4400 FAX +65.6383.4664
www.extron.com
Ceiling Mounted Paging Speaker
Priority Page Sensor
From PA system
To Priority Page Controller
Blue Sensor Cable
POWE
R
C NO
PA
G
IN
G
R
ELA
Y
D
ELA
Y
S
EN
SITI
VITY
12V
0.2AMAX
O
N
1
2
L R
A
U
X
/M
IX
IN
D
O
N
O
T
G
R
O
U
ND
O
R
S
H
O
R
T
S
P
E
A
K
E
R
O
U
T
P
U
T
S
!
1
B
1
A
I N P U T S
O U T P U T S
2
B
2
A
3
B
3
A
R
S
-2
3
2
ML
C
/
IR
D
C
V
O
L
4
/8
O
h
m
s
A
M
P
L
IF
IE
D
O
U
T
P
U
T
S
V
O
L
/M
U
T
E
T
x
A BC
R
x
IR 1
2
V
1
0
V
P
O
W
E
R
12V 3A M
A
X
U
S
LIS
TE
D
17TT
AUDIO/VIDEO
APPARATUS
®
RGB
VIDEO RGB
VIDEO
To Power Supply
Extron PPC 25
Priority Page Controller
Extron PVS 204SA
Tw isted Pair Switcher
Extron PVS 204SA
Rear Panel
LR
RS-232 MLC/IR
DC VOL
4/8
Ohms
AMPLIFIED OUTPUTS
VOL/MUTE
Tx
ABC
Rx IR 12V
10V
Mute (center)
Ground (right)
Installation Procedure
Follow all local fire and safety code requirements for installation and anchoring. Install the PPC 25
Sensor in a UL-compliant junction box with a cover to meet plenum rating requirements.
1. Open the top of the Priority Page Sensor.
2. Loop either one of the speaker wire leads around the top (open) part of the Sensor, and connect it to the speaker
as shown above. Connect the other speaker wire directly to the speaker. Polarity need not be observed.
• Fora25V or 70V system — wrap 5 to 8 loops.
• Fora4/8 ohm system — wrap 2 to 4 loops.
3. Close and latch the top of the Priority Page Sensor.
4. Cut an 18" section from the unterminated end of the supplied
blue sensor cable for use in step 8 below.
5. Strip 3/16” of insulation from each conductor on the bare wire end of the blue sensor cable. Do not tin the leads.
6. Connect the stripped leads to the 2-pole captive screw connector on the Priority Page Sensor. Polarity need not be observed.
7. Route the connector end to the PPC 25 Controller, and plug it into the PAGING SENSOR receptacle.
8. Connect the 18” 2-conductor cable (from step 4) from the RELAY OUT port on the PPC 25 Controller to the mute
control input port on the audio amp or switcher to be muted during a PA system announcement. Polarity need not be observed.
When integrating the PPC 25 into a PoleVault System:
1. Connect the 18” cable (from step 4 above) from the RELAY OUT
port on the PPC 25 Controller to the MUTE and GROUND pins on the PoleVault PVS 204SA VOL/MUTE port. Polarity need not
be observed.
2. Use the included cable assembly (PN 27-576-01LF) to power the PPC 25 from the PVS 204SA power supply. The PPC 25 must be mounted near the PVS 204SA and its power supply.
Testing and Adjustment Procedure
To test that the classroom audio is muted when a PA system announcment (page) occurs:
1. Turn the classroom audio on.
2. Speak into the PA system microphone. The classroom
audio should be muted while the PA system page occurs, and be restored when the page ends.
3. If the PPC 25 fails to mute the classroom audio during a page, turn the SENSITIVITY adjustment clockwise.
4. If classroom audio is muted without a page occurring, turn the SENSITIVITY adjustment counterclockwise.
2
PPC 25 Priority Page Sensor • Installation Instructions