CTL208CM
8-Button Control Panel Module
with Serial Control Output
68-836-01 Rev. A
Printed in the USA
07 03
Precautions
Safety Instructions • English
This symbol is intended to alert the user of important operating and maintenance (servicing) instructions in the literature provided with the equipment.
This symbol is intended to alert the user of the presence of uninsulated dangerous voltage within the product's enclosure that may present a risk of electric shock.
Caution
Read Instructions • Read and understand all safety and operating
instructions before using the equipment.
Retain Instructions • The safety instructions should be kept for future
reference.
Follow Warnings • Follow all warnings and instructions marked on the
equipment or in the user information.
Avoid Attachments • Do not use tools or attachments that are not
recommended by the equipment manufacturer because they may be hazardous.
Consignes de Sécurité • Français
Ce symbole sert à avertir l’utilisateur que la documentation fournie avec le matériel contient des instructions importantes concernant l’exploitation et la maintenance (réparation).
Ce symbole sert à avertir l’utilisateur de la présence dans le boîtier de l’appareil de tensions dangereuses non isolées posant des risques d’électrocution.
Attention
Lire les instructions• Prendre connaissance de toutes les consignes de
sécurité et d’exploitation avant d’utiliser le matériel.
Conserver les instructions• Ranger les consignes de sécurité afin de
pouvoir les consulter à l’avenir.
Respecter les avertissements • Observer tous les avertissements et
consignes marqués sur le matériel ou présentés dans la documentation utilisateur.
Eviter les pièces de fixation • Ne pas utiliser de pièces de fixation ni
d’outils non recommandés par le fabricant du matériel car cela risquerait de poser certains dangers.
Sicherheitsanleitungen • Deutsch
Dieses Symbol soll dem Benutzer in der im Lieferumfang enthaltenen Dokumentation besonders wichtige Hinweise zur Bedienung und Wartung (Instandhaltung) geben.
Dieses Symbol soll den Benutzer darauf aufmerksam machen, daß im Inneren des Gehäuses dieses Produktes gefährliche Spannungen, die nicht isoliert sind und die einen elektrischen Schock verursachen können, herrschen.
Achtung
Lesen der Anleitungen • Bevor Sie das Gerät zum ersten Mal verwenden,
sollten Sie alle Sicherheits-und Bedienungsanleitungen genau durchlesen und verstehen.
Aufbewahren der Anleitungen • Die Hinweise zur elektrischen Sicherheit
des Produktes sollten Sie aufbewahren, damit Sie im Bedarfsfall darauf zurückgreifen können.
Befolgen der Warnhinweise • Befolgen Sie alle Warnhinweise und
Anleitungen auf dem Gerät oder in der Benutzerdokumentation.
Keine Zusatzgeräte • Verwenden Sie keine Werkzeuge oder Zusatzgeräte,
die nicht ausdrücklich vom Hersteller empfohlen wurden, da diese eine Gefahrenquelle darstellen können.
Instrucciones de seguridad • Español
Este símbolo se utiliza para advertir al usuario sobre instrucciones importantes de operación y mantenimiento (o cambio de partes) que se desean destacar en el contenido de la documentación suministrada con los equipos.
Este símbolo se utiliza para advertir al usuario sobre la presencia de elementos con voltaje peligroso sin protección aislante, que puedan encontrarse dentro de la caja o alojamiento del producto, y que puedan representar riesgo de electrocución.
Precaucion
Leer las instrucciones • Leer y analizar todas las instrucciones de
operación y seguridad, antes de usar el equipo.
Conservar las instrucciones • Conservar las instrucciones de seguridad
para futura consulta.
Obedecer las advertencias • Todas las advertencias e instrucciones
marcadas en el equipo o en la documentación del usuario, deben ser obedecidas.
Evitar el uso de accesorios • No usar herramientas o accesorios que no
sean especificamente recomendados por el fabricante, ya que podrian implicar riesgos.
Warning
Power sources • This equipment should be operated only from the power source
indicated on the product. This equipment is intended to be used with a main power system with a grounded (neutral) conductor. The third (grounding) pin is a safety feature, do not attempt to bypass or disable it.
Power disconnection • To remove power from the equipment safely, remove all
power cords from the rear of the equipment, or the desktop power module (if detachable), or from the power source receptacle (wall plug).
Power cord protection • Power cords should be routed so that they are not likely to
be stepped on or pinched by items placed upon or against them.
Servicing • Refer all servicing to qualified service personnel. There are no user-
serviceable parts inside. To prevent the risk of shock, do not attempt to service this equipment yourself because opening or removing covers may expose you to dangerous voltage or other hazards.
Slots and openings • If the equipment has slots or holes in the enclosure, these are
provided to prevent overheating of sensitive components inside. These openings must never be blocked by other objects.
Lithium battery • There is a danger of explosion if battery is incorrectly replaced.
Replace it only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer's instructions.
Avertissement
Alimentations• Ne faire fonctionner ce matériel qu’avec la source d’alimentation
indiquée sur l’appareil. Ce matériel doit être utilisé avec une alimentation principale comportant un fil de terre (neutre). Le troisième contact (de mise à la terre) constitue un dispositif de sécurité : n’essayez pas de la contourner ni de la désactiver.
Déconnexion de l’alimentation• Pour mettre le matériel hors tension sans danger,
déconnectez tous les cordons d’alimentation de l’arrière de l’appareil ou du module d’alimentation de bureau (s’il est amovible) ou encore de la prise secteur.
Protection du cordon d’alimentation • Acheminer les cordons d’alimentation de
manière à ce que personne ne risque de marcher dessus et à ce qu’ils ne soient pas écrasés ou pincés par des objets.
Réparation-maintenance • Faire exécuter toutes les interventions de réparation-
maintenance par un technicien qualifié. Aucun des éléments internes ne peut être réparé par l’utilisateur. Afin d’éviter tout danger d’électrocution, l’utilisateur ne doit pas essayer de procéder lui-même à ces opérations car l’ouverture ou le retrait des couvercles risquent de l’exposer à de hautes tensions et autres dangers.
Fentes et orifices • Si le boîtier de l’appareil comporte des fentes ou des orifices,
ceux-ci servent à empêcher les composants internes sensibles de surchauffer. Ces ouvertures ne doivent jamais être bloquées par des objets.
Lithium Batterie • Il a danger d'explosion s'll y a remplacment incorrect de la
batterie. Remplacer uniquement avec une batterie du meme type ou d'un ype equivalent recommande par le constructeur. Mettre au reut les batteries usagees conformement aux instructions du fabricant.
Vorsicht
Stromquellen • Dieses Gerät sollte nur über die auf dem Produkt angegebene
Stromquelle betrieben werden. Dieses Gerät wurde für eine Verwendung mit einer Hauptstromleitung mit einem geerdeten (neutralen) Leiter konzipiert. Der dritte Kontakt ist für einen Erdanschluß, und stellt eine Sicherheitsfunktion dar. Diese sollte nicht umgangen oder außer Betrieb gesetzt werden.
Stromunterbrechung • Um das Gerät auf sichere Weise vom Netz zu trennen,
sollten Sie alle Netzkabel aus der Rückseite des Gerätes, aus der externen Stomversorgung (falls dies möglich ist) oder aus der Wandsteckdose ziehen.
Schutz des Netzkabels • Netzkabel sollten stets so verlegt werden, daß sie nicht
im Weg liegen und niemand darauf treten kann oder Objekte darauf- oder unmittelbar dagegengestellt werden können.
Wartung • Alle Wartungsmaßnahmen sollten nur von qualifiziertem
Servicepersonal durchgeführt werden. Die internen Komponenten des Gerätes sind wartungsfrei. Zur Vermeidung eines elektrischen Schocks versuchen Sie in keinem Fall, dieses Gerät selbst öffnen, da beim Entfernen der Abdeckungen die Gefahr eines elektrischen Schlags und/oder andere Gefahren bestehen.
Schlitze und Öffnungen • Wenn das Gerät Schlitze oder Löcher im Gehäuse
aufweist, dienen diese zur Vermeidung einer Überhitzung der empfindlichen Teile im Inneren. Diese Öffnungen dürfen niemals von anderen Objekten blockiert werden.
Litium-Batterie • Explosionsgefahr, falls die Batterie nicht richtig ersetzt wird.
Ersetzen Sie verbrauchte Batterien nur durch den gleichen oder einen vergleichbaren Batterietyp, der auch vom Hersteller empfohlen wird. Entsorgen Sie verbrauchte Batterien bitte gemäß den Herstelleranweisungen.
Advertencia
Alimentación eléctrica • Este equipo debe conectarse únicamente a la fuente/tipo
de alimentación eléctrica indicada en el mismo. La alimentación eléctrica de este equipo debe provenir de un sistema de distribución general con conductor neutro a tierra. La tercera pata (puesta a tierra) es una medida de seguridad, no puentearia ni eliminaria.
Desconexión de alimentación eléctrica • Para desconectar con seguridad la
acometida de alimentación eléctrica al equipo, desenchufar todos los cables de alimentación en el panel trasero del equipo, o desenchufar el módulo de alimentación (si fuera independiente), o desenchufar el cable del receptáculo de la pared.
Protección del cables de alimentación • Los cables de alimentación eléctrica se
deben instalar en lugares donde no sean pisados ni apretados por objetos que se puedan apoyar sobre ellos.
Reparaciones/mantenimiento • Solicitar siempre los servicios técnicos de personal
calificado. En el interior no hay partes a las que el usuario deba acceder. Para evitar riesgo de electrocución, no intentar personalmente la reparación/ mantenimiento de este equipo, ya que al abrir o extraer las tapas puede quedar expuesto a voltajes peligrosos u otros riesgos.
Ranuras y aberturas • Si el equipo posee ranuras o orificios en su caja/alojamiento,
es para evitar el sobrecalientamiento de componentes internos sensibles. Estas aberturas nunca se deben obstruir con otros objetos.
Batería de litio • Existe riesgo de explosión si esta batería se coloca en la posición
incorrecta. Cambiar esta batería únicamente con el mismo tipo (o su equivalente) recomendado por el fabricante. Desachar las baterías usadas siguiendo las instrucciones del fabricante.
FCC Class A Notice
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense.
Note: This unit was tested with shielded cables on the peripheral devices. Shielded cables must be used with the unit to ensure compliance.
Extron’s Warranty
Extron Electronics warrants this product against defects in materials and workmanship for a period of three years from the date of purchase. In the event of malfunction during the warranty period attributable directly to faulty workmanship and/or materials, Extron Electronics will, at its option, repair or replace said products or components, to whatever extent it shall deem necessary to restore said product to proper operating condition, provided that it is returned within the warranty period, with proof of purchase and description of malfunction to:
USA, Canada, South America, Europe, Africa, and the Middle East: and Central America:
Extron Electronics, Europe Extron Electronics Beeldschermweg 6C 1230 South Lewis Street 3821 AH Amersfoort Anaheim, CA 92805, USA The Netherlands
Asia: Japan:
Extron Electronics, Japan Extron Electronics, Asia Daisan DMJ Bldg. 6F, 135 Joo Seng Road, #04-01 3-9-1 Kudan Minami PM Industrial Bldg. Chiyoda-ku, Tokyo 102-0074 Singapore 368363 Japan
This Limited Warranty does not apply if the fault has been caused by misuse, improper handling care, electrical or mechanical abuse, abnormal operating conditions or non-Extron authorized modification to the product.
If it has been determined that the product is defective, please call Extron and ask for an Applications Engineer at (714) 491-1500 (USA), 31.33.453.4040 (Europe),
65.6383.4400 (Asia), or 81.3.3511.7655 (Japan) to receive an RA# (Return Authorization number). This will begin the repair process as quickly as possible.
Units must be returned insured, with shipping charges prepaid. If not insured, you assume the risk of loss or damage during shipment. Returned units must include the serial number and a description of the problem, as well as the name of the person to contact in case there are any questions.
Extron Electronics makes no further warranties either expressed or implied with respect to the product and its quality, performance, merchantability, or fitness for any particular use. In no event will Extron Electronics be liable for direct, indirect, or consequential damages resulting from any defect in this product even if Extron Electronics has been advised of such damage.
Please note that laws vary from state to state and country to country, and that some provisions of this warranty may not apply to you.
Quick Start Guide — CTL208CM
CAUTION
Installation and service must be performed by authorized personnel only. These units must be installed in accordance with national and local electrical codes.
Step 1
Power off all devices and disconnect them from the power source, if necessary.
Step 2
Run the serial cable between the control panel module’s installation location and the device to be controlled.
Step 3
As necessary, install a wall box, table connector bay, or other mini­AAP mounting option into which the control panel module will be installed.
Step 4
Configure the control panel module’s rear panel DIP switches.
Step 5
Connect a serial cable between the control panel module and a computer.
Step 6
Connect the external power supply to the control panel module.
Step 7
Program the control panel module’s buttons as desired, using either the Extron ICS100 control software or the Extron ASCII character command set.
Step 8
If necessary, set the control panel module’s serial control settings to match those of the device to be controlled using the Extron ASCII character command set.
Step 9
Disconnect the serial control cable from the computer and install the serial control cable between the control panel module and the device to be controlled.
CTL208CM Control Panel Module • Quick Start Guide
QS-1
Quick Start Guide — CTL208CM, cont’d
Table of Contents
Step 10
If the rear of the control panel module will be inaccessible when the installation is complete, the module should be powered up and its operation should be tested before the final installation.
Apply or connect power to all devices in the system.
Step 11
Test the system: Ensure that the controlled device responds as desired to the control panel module buttons. Correct the programming or system wiring as necessary. Ensure that you remove electrical power if you need to change the system wiring.
Step 12
Mount the control panel module into any Extron four-space mini­AAP panel.
If the rear of the control panel module will be inaccessible when the installation is complete, all cables, including the power connector on the CTL208, must be connected before the permanent installation.
Step 13
Mount the mini-AAP connector panel as necessary. See chapter 2, Installation, for further wall mounting details.
Step 14
Restore power to all devices. The installation is now complete.
Chapter 1 • Introduction ..........................................................1-1
About the CTL208CM ........................................................... 1-2
Features ...................................................................................... 1-2
Chapter 2 • Installation ............................................................. 2-1
Installation Overview ......................................................... 2-2
UL Requirements for Wall Box Installation.............. 2-4
Wall Mounting Site Preparation .................................... 2-4
Device Configuration .......................................................... 2-7
Wall Mounting .........................................................................2-8
Rear Panel Setup ................................................................... 2-9
Chapter 3 • Operation ................................................................3-1
Button Modes ...........................................................................3-2
Send Programmed Commands ....................................... 3-2
Factory Reset ...........................................................................3-4
Chapter 4 • Serial Communications .................................. 4-1
ICS100 Windows Control Program ................................ 4-2
System requirements ............................................................ 4-2
Installing the software .......................................................... 4-2
Starting the program ............................................................ 4-3
Using the software to program the CTL208CM ...................4-5
Using the help system ........................................................... 4-8
Serial Commands................................................................... 4-9
Communications protocols .................................................... 4-9
Command and response structure ........................................4-9
Addressing the unit ............................................................... 4-9
Control panel module responses .........................................4-10
Using the command/response table ...................................4-10
Symbols ........................................................................... 4-11
Command/response table for programming the CTL208 ...4-13
CTL208CM Control Panel Module • Quick Start Guide
CTL208CM Control Panel Module • Table of Contents
iQS-2
Table of Contents, cont’d
Appendix • Reference Information .................................. A-1
Specifications ......................................................................... A-2
Parts List.................................................................................... A-3
Included parts ........................................................................ A-3
Mini-AAP mounting options ................................................. A-3
Wall mounting solutions ................................................... A-3
Architectural solutions ....................................................... A-4
Table solutions .................................................................. A-4
Wall mounting hardware ..................................................... A-4
CTL208CM Control Panel Module
Chapter One
1
68-836-01 Rev. A
Printed in the USA
All trademarks mentioned in this manual are the properties of their respective owners.
ii
CTL208CM Control Panel Module • Table of Contents
Introduction
About the CTL208CM
Features
07 03
Introduction, cont’d
Introduction
About the CTL208CM
The Extron CTL208CM is a programmable 8-button control panel module that can be connected to any serial-controlled device (figure 1-1). Each button can store one or two command strings that are programmed with either ASCII or hex characters. When you push the button, the control panel module issues the programmed ASCII or hex string to the connected device.
Projector
Control
VCR
Figure 1-1 — Typical CTL208CM application
The control panel module is incorporated into a four space mini­AAP enclosure that can be mounted into a variety of Extron mini-AAP architectural options, including wall plates (such as the CPM101), table-mounted connector bays (such as the CPM208), or an interface or other device that has its own mini­AAP mounting bays (such as the CIA111).
The control panel module requires 9VDC to 13VDC and ships with an external 12VDC power supply.
Features
Eight buttons with indicator LEDs — Each button can be
programmed with one or two (primary and secondary) ASCII or hex strings.
RS-232
DVD Laptop
Extron CTL208CM
Control Module Projector on/off control
Projector input switching Projector volume control
Four operating modes per button — Each button can be set to
one of four operating modes: single (default), toggle, press/release, or continuous
Single mode — The control panel module sends the
primary ASCII or hex string programmed to a button when you press that button.
Toggle mode — The control panel module sends the
primary ASCII or hex string programmed to a button when you press that button. The module sends the secondary string when you press the button a second time.
Button grouping — Buttons that are in toggle mode
can also be assigned to a group. When one button is selected, the control panel module deselects all other buttons in the group.
Button timeout — Buttons that are in toggle mode
can be further set to automatically toggle off after a user-defined period of time, up to 255 minutes.
Press/release mode — The control panel module sends
the primary ASCII or hex string programmed to a button when you
press that button and the secondary string
when you release the button.
Continuous mode — The control panel module
repeatedly sends the primary ASCII or hex string programmed to a button for as long as you press and
hold that button.
Serial programming — The buttons are programmable, under
RS-232, RS-422, and RS-485 serial control, using either the included Extron ICS100 control software or the Extron ASCII character command set.
Serial outputs — The control panel module outputs the ASCII
or hexadecimal strings to the connected device using either RS-232, RS-422, or RS-485 serial protocol.
Four space mini-AAP enclosure — The CTL208 can be mounted
into a variety of Extron mini-AAP architectural options, such as wall plates, table-mounted connector bays, or interfaces with their own mini-AAP mounting bays.
2 colors — Available in either a black or white finish. Custom engraved front panels — Extron can create custom
front panels, in either the black or the white finish, to neatly and professionally label each button. Contact the Extron S
3
Sales & Technical Support Hotline to order the
panels.
1-2
CTL208CM Control Panel Module • Introduction
CTL208CM Control Panel Module • Introduction
1-3
Introduction, cont’d
CTL208CM Control Panel Module
Chapter Two
2
1-4
Installation
Installation Overview
UL Requirements for Wall Box Installation
Wall Mounting Site Preparation
Device Configuration
Wall Mounting
Rear Panel Setup
CTL208CM Control Panel Module • Introduction
Installation, cont’d
Installation
Installation Overview
CAUTION
If desired, order a custom engraved front panel. Contact
1
the Extron S3 Sales & Technical Support Hotline to order the panel.
Power off all devices and disconnect them from the
2
power source, if necessary.
Run a serial cable between the site where the CTL208CM
3
control panel module will be installed and the site of the serial-controlled device.
For installation in a wall or furniture, prepare the site:
4
cut a hole in the surface, install the electrical box or mounting bracket, and prepare the cables. See Wall
Mounting Site Preparation in this chapter. See appendix A, Reference Information, for a partial list of devices that can
accept four space mini-AAPs.
For other installations, install a tabletop or in-table
5
connector bay, or other mini-AAP mounting option. Refer to the manual for the device in which the control panel module will be installed. See appendix A, Reference Information, for a partial list of devices that can accept four space mini-AAPs.
Connect a serial cable between the control panel module
6
and a computer. See Rear Panel Setup, in this chapter for details.
Alternatively, you can connect the control panel module to an RS-485 serial port daisy chain that includes the programming computer and the device to be controlled. In a daisy-chain configuration, you can make changes to the control panel module’s button programming as needed, without removing the panel from its installation.
If necessary, configure the control panel module’s rear
7
panel DIP switches to match the serial protocol (RS-232, RS-422, RS-485) of the computer used to program the control panel module. See Rear Panel Setup, in this chapter for details.
Connect the power source to the control panel module.
8
See Rear Panel Setup, to wire the power connector.
Installation and service must be performed by authorized personnel only. UL Listed electrical boxes are recommended. See UL Requirements
for Wall Box Installation in this chapter.
Program the control panel module’s buttons as desired,
9
using either the Extron ICS100 control software or the Extron serial character command set. See ICS100 Windows
Control Program and/or Serial Commands in chapter 4, Serial Communications, for details.
If necessary, configure the control panel module’s serial
10
control protocol settings (baud rate, data bits, and stop bits) to match those of the device to be controlled. See ICS100 Windows Control Program and/or Serial Commands in chapter 4, Serial Communications, for details.
If necessary, reconfigure the control panel module’s rear
11
panel DIP switch 1 to match the serial protocol (RS-232, RS-422, RS-485) of the device to be controlled. See Rear Panel Setup, in this chapter for details.
If the computer, control panel module, and the device to
12
be controlled are not part of an RS-485 serial port daisy chain, disconnect the serial control cable from the computer and install the serial control cable between the control panel module and the device to be controlled.
If the rear of the control panel module will be inaccessible when the installation is complete, the operation of the module should be tested before the final mounting.
Apply or connect power to all devices in the system.
13
Test the system: Ensure that the controlled device
14
responds as desired to the control panel module buttons. If necessary, correct the programming and/or the system wiring. Ensure that you remove electrical power if you need to change the system wiring. Test the system again.
Disconnect power from the control panel module and
15
other devices.
Mount the control panel module into any Extron four-
16
space mini-AAP connector panel.
If the rear of the control panel module will be inaccessible when the installation is complete, all cables, including the power connector on the CTL208, must be connected before the permanent installation.
Mount the mini-AAP connector panel to the mini-AAP
17
mounting option as necessary. See Wall mounting in this chapter for details about wall mounting the panel.
Restore power to all devices.
18
2-2
CTL208CM Control Panel Module • Installation
CTL208CM Control Panel Module • Installation
2-3
Installation, cont’d
UL Requirements for Wall Box Installation
The following Underwriters Laboratories (UL) requirements pertain to the installation of the CTL208CM into a wall or furniture (figure 2-1).
Installation Cable
Conduit
H. SHIFT
INPUT SELECT
MIN/MAX
1 2
2.5"
AUDIO 2
MONITOR
INPUT 2
AUDIO 1
FOLLOWS
MONITOR
INPUT 1
INPUT 1
Extron RGB 478 Mxi
RGB 478 Mxi
WITH ADSP™
Extron CTL208CM
Control Module
Interface
Figure 2-1 — CTL208CM in a four-gang wall box
1. These units are not to be connected to a centralized DC
power source or used beyond their rated voltage range.
2. These units must be installed in UL listed junction boxes.
3. These units must be installed with conduit in accordance
with the National Electrical Code.
Wall Mounting Site Preparation
The control panel module can be mounted in a wall-mountable four space mini-AAP A/V connector panel (such as a one-gang CPM101) and then set into a wall with either a standard stud­mounted wall box or with a wall mounting bracket (IN9181). The control panel module can also be mounted to any wall­mountable Extron device that incorporates a four space A/V mini-AAP connector panel, such as a three-gang RGB 468 Mxi. See Mini-AAP mounting options in Appendix A, Reference Information, for a partial list of devices that can accept four space mini-AAPs.
Choose a location that allows power cable and serial control cable runs without interference. Allow enough depth for the wall box and the cables. You should install the cables in the wall or furniture, with or without conduits, before installing the mounting bracket or wall box.
The installation must conform to national and local electrical codes and to the equipment’s size requirements.
Installation using a UL listed wall box (available from Extron) is recommended for most mounting options, but the optional wall mounting bracket can be used instead. All wall boxes must be at least 2.5” (6.4 cm) deep.
Before using the wall mounting bracket, verify that the installation conforms to national and local electrical codes.
Prepare the site as follows:
1. If your wall box or mounting bracket includes a paper template, cut out the indicated portions of the template. If
the wall box or mounting bracket does not include a template, use the wall box or bracket itself to size the hole.
2. Place the template, wall box, or mounting bracket against the installation surface, and mark the guidelines for the opening on the wall or furniture.
3. Cut out the wall/furniture material from the marked area.
4. Check the opening size by inserting the wall box or
mounting bracket into the opening. The box or bracket should fit easily into the opening. Enlarge or smooth the edges of the opening if needed.
5a. If you are using a wall box, feed cables through the wall
box punch-out holes, and secure them with cable clamps to provide strain relief.
Exposed cable shields (braids or foil) are potential sources of short circuits. Trim back and/or insulate shields with heat shrink (figure 2-2).
Screw
Braided Shield
Cable Clamp
Install Cable
Foil Shield
Metal Wall Box
Figure 2-2 — Grounding outer braided and foil shields
To prevent short circuits, the outer foil shield can be cut back to the point where the cable exits the cable clamp. Both braided and foil shields should be connected to an equipment ground at the other end of the cable.
CTL208CM Control Panel Module • Installation
CTL208CM Control Panel Module • Installation
2-52-4
Installation, cont’d
5b. If you are using a wall box, insert the wall box into the
opening, and attach it to the wall stud or furniture with nails or screws, leaving the front edge flush with the outer wall or furniture surface (figure 2-3). The illustration applies to both two-gang and four-gang wall boxes.
Wall Stud
Installation
Cable
Cable Clamp
Screws or Nails
Wall opening
flush with
edge of box
Figure 2-3 — Attaching a wall box to a stud
If attaching the wall box to wood, use four #8 or #10 screws or 10-penny nails. A minimum of 1/2 inch (1.3 cm) of screw threads must penetrate the wood.
If attaching the wall box to metal studs or furniture, use four #8 or #10 self-tapping sheet metal screws or machine bolts with matching nuts.
6. If you are using a mounting bracket, follow the directions,
if any, that came with the mounting bracket to attach the
clips that fasten the ring to the wall or furniture (figure 2-
4).
Push Mounting Tabs Forward
Figure 2-4 — Attaching a mounting bracket to a wall
Device Configuration
The rear of the control panel module will be inaccessible after installation.
1. Cable the control panel module and set the DIP switches. See Rear Panel Setup in this chapter.
2. Program the buttons. See chapter 4, Serial Communications, to program the control panel module.
3. Test the control panel module before installing it into the wall box.
Wall
Extron
IN9181 Wall Mounting Bracket
CTL208CM Control Panel Module • Installation
CTL208CM Control Panel Module • Installation
2-72-6
Installation, cont’d
123
4
5
6
0
1
ON
1234
56
FUNCTIONSWITCH SETTING
GND TX­TX+ RX­RX+
+
-
9 - 13 VDC
@
500MA
1 SERIAL MODE
0 - RS232
2 & 3
TERMINATION
1- RS485/RS422
1 - 120 OHMS 0 - OPEN
(END UNIT) 4 RESERVED 5 FACTORY RESET
0 - NORMAL
SPARE6
1
3
2
Wall Mounting
Button
number
1
2
3
4
Figure 2-5 — Button locations
1. Sandwich the mini-AAP panel (such as a CPM101)
between the control panel module (without its front panel) and the module’s front panel. Secure the front panel to the control panel module with the included #4-40 screws (figure 2-6).
The physical orientation of the control panel module is important when you are programming and operating the buttons. Buttons 1 and 5 (figure 2-5) are on top when the CTL208 is right-side up. Orient the CTL208 so that the text on the rear of the unit is right-side up to determine the top of the module.
Button
number
5
6
7
8
2. If not already accomplished, attach the power and serial
cables to the rear of the control panel module. Power on the control panel module now if the external power supply cannot be accessed once the module is mounted.
3. Mount the CPM101 or other mini-AAP panel (with the
attached control panel module) to the wall box or mounting bracket using the two included mounting screws (figure 2-6).
Figure 2-6 shows a wall box installation. Mounting the mini-AAP panel to a mounting bracket is identical.
4. Power on all devices.
Rear Panel Setup
All of the connectors and DIP switches necessary for connecting
and configuring the CTL208CM are on the rear panel (figure 2-7).
Extron
Figure 2-7 — Rear panel view
CPM101
Wall opening flush with edge of box
2-8
Figure 2-6 — Attaching the mini-AAP panel to a wall box
CTL208CM Control Panel Module • Installation
Extron CTL208CM
Control Module
Front Panel
A/V Connector Panel
CTL208CM Control Panel Module • Installation
2-9
Installation, cont’d
Power Supply
Output Cord
AA
SECTION A–A
RS-232
GND
Serial port connector — This port is a 3.5 mm, 5-pole captive
1
screw connector for serial RS-232, RS-422, or RS-485 communications. Connect to the port as shown in figure 2-7.
The port serves two functions:
Connects the control panel module to a computer to program the module’s buttons.
DIP switch 5 is a factory reset control. See Factory Reset in chapter 3, Operation.
The default settings for all switches for an RS-232 connection is off (0). DIP switch 3 should be turned on for an RS-485 full duplex connection only, and only if the CTL is the first or last unit in a daisy chain.
Connects the control panel module to the device to be
Captive screw power connector — Power the control panel
controlled, such as a projector or switcher.
Full duplex RS-422/485
TX-
TX+
RX-
RX+
GND
TX-
TX+
RX-
RX+
Half duplex RS-485
GND
TX-
TX+
RX-
RX+
3
module one of two ways:
Connect the control panel module to a device with auxiliary 12VDC outputs, such as an Extron MSV0502-3 or MSV0804-3 matrix switcher. Figure 2-8 shows how to wire
RX
2
TX
3
GND
5
Pin #
Computer Serial
Port (DB-9)
RX+
3
RX-
7
TX+
2
TX-
6
GND
5
GND
1
Computer Serial
Port (DB-9)
RX+
3
RX-
7
TX+
2
TX-
6
GND
5
GND
1
Pin #Pin #
Computer Serial
Port (DB-9)
the power connector.
Connect the included 12VDC external power supply to the 2-pole female direct insertion captive screw connector. Figure 2-8 shows how to wire the power connector.
Figure 2-7 — Serial port pin assignments
RS-485 implementation may vary between computers or control systems. Connect the control cable as shown in
Figure 2-8 — Power connector wiring
figure 2-7. If the serial communications link with the control panel module switcher does not work, try reversing the polarity of the TX and RX signal lines.
Do not tin the stripped power supply leads before inserting them into the captive screw connector. Tinned leads are not as securely attached as untinned leads and
Serial port configuration DIP switches —
2
could slip out.
DIP switch 1 configures the control panel module’s serial port to operate as RS-232, RS-422, or RS-485. DIP switches 2 and 3 are used to terminate the RX and TX lines when the control panel
The two power supply leads must be kept separated while the power supply is plugged into an electrical outlet. Remove power before wiring.
module is at the end of a line of serial devices. The table below defines the switch positions.
To verify correct polarity before connection, check the power supply’s no load output with a voltmeter.
Switch Function
1 Serial mode
2Rx
termination
3Tx
termination
2-10 2-11
CTL208CM Control Panel Module • Installation
or Off (0) if half duplex.
* If the CTL is the last unit in a daisy chain.
RS-485
position
On (1) On (1)
On (1)*
or Off (0).
On (1) if full duplex*
RS-422
position
On (1)*
or Off (0).
RS-232
position
Off (0)
Off (0)
Off (0)Off (0)
CTL208CM Control Panel Module • Installation
Installation, cont’d
CTL208CM Control Panel Module
Chapter Three
3
2-12
Operation
Button Modes
Send Programmed Commands
Factory Reset
CTL208CM Control Panel Module • Installation
Operation, cont’d
5
6
7
8
1
Button
number
Button
number
2
3
4
Operation
Button Modes
Before a control panel module button is programmed, it has no function. See chapter 4, Serial Communications, to program the buttons. Programming includes:
Assigning the program string(s) to the button. One or
two strings (primary and secondary) can be assigned to each button.
Setting each program string to be either ASCII or hexadecimal.
Setting the mode for each button. The mode for each button can be any one of the following:
Single — Sends the primary program string when
Toggle — Sends the primary program string when
Press/release— Sends the primary program string
Continuous — Sends the primary program string
For toggle mode, if desired, setting a group or timeout:
Group — Buttons that are in toggle mode can also be
Timeout — Buttons that are in toggle mode can be
pushed.
pushed once. Sends the secondary program string when pushed a second time.
when pushed. Sends the secondary program string when released.
when pressed and continues to repeat sending the primary command string for as long as the button is held.
assigned to a group. When one button is selected, the control panel module deselects all other buttons in the group.
Groups cannot be assigned to buttons that are set to operate with a timeout.
further set to automatically toggle off after a user­defined period of time, up to 255 minutes.
Timeouts cannot be assigned to buttons that are set to operate in groups.
Send Programmed Commands
Figure 3-1 — Power connector wiring
The actions that occur when you push a programmed button vary, depending on how the button is programmed.
Single mode — Push the button to send the primary
program string. The button’s LED flashes once.
Toggle mode — Push the button to send the primary
program string. The button’s LED lights. Push the button a second time to send the secondary string. The button’s LED goes out.
Press/release mode Press and hold the button to send
the primary program string. The button’s LED lights. Release the button to send the secondary string. The button’s LED goes out.
Continuous mode Press and hold the button to
repeatedly send the primary program string. The button’s LED lights. Release the button to stop sending the string. The button’s LED goes out.
Two or more buttons set to toggle mode and grouped —
Push a button in the group to send that button’s primary program string. That button’s LED lights. If another button in the group was selected, that button is deselected (its LED goes out).
When buttons are grouped, the CTL208 does not send the secondary command string for the button it deselects when you select a new button in the group.
3-2 3-3
CTL208CM Control Panel Module • OperationCTL208CM Control Panel Module • Operation
Operation, cont’d
Toggle mode and a timeout set — Push a button to send the primary program string. The button’s LED lights. When you push the button a second time or when the timeout expires, the control panel module sends the secondary program string. The button’s LED goes out
Factory Reset
With power removed, set rear panel DIP switch 5 to on (up). Reapply power. Set switch 5 back to off (down). The DIP switch factory reset performs the following functions:
Resets the control panel module’s serial port to 9600 baud, no parity, Xoff, and half duplex mode
Resets the module’s address to 97;
Enables the front panel
Erases all button codes
Resets all buttons to single mode
Resets all button groups and timeouts to 0.
If you push the button a third time, the timeout interval starts over; that is, if the timeout is set to 30 minutes, the control panel module will send the secondary string 30 minutes later.
The CTL208’s clock is always running and the programmed timeout occurs on the full minute. Thus, the timeout can occur up to 59 seconds earlier than the number of minutes programmed. Over the length of the average timeout setting, this “early” timeout is considered of no consequence.
Ensure that you reset switch 5 to off (down). If you leave the switch on (up), the control panel module will reset every time you power it on.
CTL208CM Control Panel Module
Chapter Four
4
Serial Communications
ICS100 Windows Control Program
Serial Commands
3-4
CTL208CM Control Panel Module • Operation
Serial Communications, cont’d
Serial Communications
The control panel module must be programmed before it can be operated. Programming can include setting several serial port variables to match the device to be controlled and includes entering the primary and secondary (if applicable) code for each button.
You can program the control panel module either by using the ICS100 windows control program or by sending individual ASCII commands. Both programming methods require that a serial port cable be connected between a computer and the control panel module’s serial port.
ICS100 Windows Control Program
The ICS100 Control Program, a graphical control software for Windows, provides a way to program the control panel module.
System requirements
Operating system — Windows 95 / 98 / ME / NT / 2000 / XP / XP Pro
If using Windows NT, Service Pack 6 must be installed.
Hardware — Pentium 150 or faster CPU
Memory — Minimum: 128 MB
Recommended: 256 MB
Screen resolution — Minimum: 800 x 600
Recommended: 1024 x 768
Disk space — 5 MB
Installing the software
The control program is contained on a CD-ROM, and must be installed on the hard drive.
1. Click Start > Run.
2. Click the Browse button. An open file window appears.
3. Navigate to the drive or folder that contains the software.
4. Double click the setup icon.
5. Click Ok in the Run window.
6. Click Ok in the InlineControl Setup window.
7. Click the icon button in the next InlineControl Setup to
install the software in the default (Extron) directory in the Program group.
If you want to specify a different directory, click on the Change Directory button.
8. The next InlineControl Setup window that appears
indicates when setup is complete. Click Ok.
Starting the program
Start the control program and establish communications with the CTL208 as follows:
1. Click Start > Programs > Extron > ICS100. The control
program window (figure 4-1) appears. The CTL208 will not respond until it has been contacted
with the valid address; after a moment, the program reports a failure to connect (figure 4-1).
Figure 4-1 — ICS100 program window and warning
2. Click OK.
The control panel module’s serial port is factory­configured to 9600 baud, no parity, no flow control, half­duplex mode. If desired, serial port settings can be changed from within the ICS100 program.
3. If you need to change serial port settings, click
Communications > Comm Port > Comm 1 (or the correct Comm port). The Serial Port Setup window appears (figure 4-2).
Figure 4-2 — Serial Port Setup window
4-2 4-3
CTL208CM Control Panel Module • Serial Communications
CTL208CM Control Panel Module • Serial Communications
Serial Communications, cont’d
a. Click in the appropriate radio buttons to select the
desired settings.
b. Click Ok.
If you change the serial protocols, communications between the computer and the control panel module are lost until the computer is updated to match the new control panel module settings).
4. Click Inline Model > Select Address. The Addresses window
(figure 4-3) appears.
Figure 4-3 — Addresses window
The control panel module must be addressed before it will accept and respond to commands. The addressing operation routes setup information to a particular unit on a network and enables command responses. Once the control panel module is addressed, it can accept an unlimited number of commands. If a different unit is addressed, the CTL208 ignores subsequent commands until it is addressed again.
Using the software to program the CTL208CM
Use the control program to program the CTL208 buttons as follows:
1. Click Inline Model > Query Hardware to configure the
ICS100 program to communicate with the CTL208 and to confirm that communications have been established with the control panel module. The Connected window appears (figure 4-4).
Figure 4-4 — Connected window
Click Ok.
2. Click Controls > Control Panel. The CTL208 control panel
(figure 4-5) appears.
The factory-installed default address is 97, but this number can be changed. The control panel module can also take commands after receiving a broadcast address of 00, but it will not send responses. Broadcast addressing is for multiple units on an RS-485 serial line in half duplex mode.
After you are finished sending commands to the control panel module, always end the session by selecting a different address than the one assigned to the CTL208. This prevents the module from responding to commands meant for another unit.
5. Click and drag on the slider or click the scroll up ( ) or
down ( ) button until the desired address is visible.
6. Click on the desired address. The default address is 97.
7. Click Ok.
4-4 4-5
CTL208CM Control Panel Module • Serial Communications
CTL208CM Control Panel Module • Serial Communications
Figure 4-5 — CTL208 control panel window
Serial Communications, cont’d
3. For each button to be programmed, click the pull down
menu above the numbered panel button and select a mode: 0 Single, 1 Toggle, 2 Press/Release, or 3 Continuous. See Button Modes in chapter 3, Operation, for definitions of the various button modes.
4. For each button to be programmed, click the numbered
panel button.
a. If you selected toggle mode in step 3, the Toggle
Mode Timeout window appears (figure 4-6).
Figure 4-6 — Toggle Mode Timeout window
Click and drag the slider to select the number of minutes (1 to 255) interval you want to pass before the button times out. Select 0 for no button timeout.
Timeouts cannot be assigned to buttons that are set to operate in groups.
Click the to save the timeout value and close the window. The Button Codes window appears (figure 4-7).
in the upper right corner of the window
5. In the Button Codes window, click in the ASCII or Hex
radio button to select the appropriate format.
Selecting the Hex radio button causes the CTL to convert the primary code that you will enter in step 6 to a hex value before saving it. Then, when you press the button, the CTL sends the hex value.
6. In the Button Codes window (figure 4-7), enter the desired
primary code in the Code 1 window.
Codes that are intended to be hex codes must be in pairs. Use a leading 0 if necessary. Letters must be upper case.
Many common keyboard key codes, which are often required for ASCII or hex control of another device, are available in the selection buttons on the bottom of the window. Selections made in these buttons are displayed in the Code window as |.
Click Program to save the command.
7. In the Button Codes window, click in the ASCII or Hex
radio button to select the appropriate format.
Selecting the Hex radio button causes the CTL to convert the secondary code that you will enter in step 8 to a hex value before saving it. Then, when you press the button, the CTL sends the hex value.
8. In the Button Codes window, if applicable, enter the
desired secondary code in the Code 2 window.
Codes that are intended to be hex codes must be in pairs. Use a leading 0 if necessary. Letters must be upper case.
The control panel module will only send the secondary code for a button if that button is in toggle or press/ release mode.
Click Program to save the command.
9. Click the in the upper right corner of the window to
close the window.
Figure 4-7 — Button Codes window
b. If you selected single, press/release, or continuous
mode in step 3, the Button Codes window appears
(figure 4-7).
4-6 4-7
CTL208CM Control Panel Module • Serial Communications
CTL208CM Control Panel Module • Serial Communications
10. For each button set to toggle mode, if desired, click in the
Group 1 or 2 checkbox to assign the button to a group. See Button Modes in chapter 3, Operation, for a definition of a group.
Serial Communications, cont’d
Buttons must be set to operate in toggle mode to assign groups.
Groups cannot be assigned to buttons that are set to operate in toggle mode and are assigned a timeout value.
11. When all of the desired programming changes are made,
click the Program button at the bottom of the window to send all of the programming entries to the control panel module.
End the session by selecting a different address than the one assigned to the CTL208. This prevents the module from responding to commands meant for another unit.
12. Click Inline Model > Select Address. The Addresses
window (figure 4-2) appears.
13. Click and drag on the slider or click the scroll up (
down ( ) button until an address other than the CTL208’s address is visible.
14. Click on the desired address.
15. Click Ok.
16. If necessary, reconfigure the comm port.
The communications protocols of the control panel module should match the optimum protocols of the device to be controlled.
17. If you need to change serial port settings to match the serial communication protocol of the device to be controlled, click Communications > Comm Port > Comm 1 (or
the correct Comm port). The Serial Port Setup window appears (figure 4-3).
a. Select the desired settings by clicking in the
appropriate radio buttons.
b. Click Ok.
18. Click the
window to exit the program.
in the upper right corner of the startup
Using the help system
For information about program features, you can access the help program in the following ways:
From within the ICS100 startup window, click on the Help entry on the task bar.
From within the Button Codes window, press the F1 key.
) or
Serial Commands
Communication protocols
The control panel module’s serial port is factory-configured to 9600 baud, no parity, no flow control, half-duplex mode.
If you change the serial protocols, communications between the computer and the control panel module are lost until the computer is updated to match the new control panel module settings.
The communications protocols of the control panel module should match the protocols of the device to be controlled.
Command and response structure
Valid commands consist of a leading delimiter, one or more characters in a command code, and an ending delimiter. The control panel module’s response to an RS-232 command also consists of a leading delimiter, a command code, and an ending delimiter.
The control panel module’s leading delimiter code is always a left bracket ( [ ). The ending delimiter code is always a right bracket ( ] ).
Example: [CPp@] — where “[“ is the leading code, “CPp@” is the command (reset the serial port to default values), and “]” is the ending code.
Addressing the unit
The control panel module must be addressed before it will accept and respond to commands. The address packet ([CC##], where ## is the 2-digit address ) routes setup information to a particular unit on a network and enables command responses. Once the control panel module is addressed, it can accept an unlimited number of commands. If a different unit is addressed, the CTL208 ignores subsequent commands until addressed again.
The factory-installed default address is 97, but this number can be changed. The control panel module can also take commands after receiving a broadcast address of 00, but it will not send responses. Broadcast is for multiple units on an RS-485 serial line in half duplex mode.
After you are finished programming the control panel module, always terminate the session by sending an address packet to another unit with a different address. This prevents the module from responding to commands meant for another unit.
4-8 4-9
CTL208CM Control Panel Module • Serial Communications
CTL208CM Control Panel Module • Serial Communications
Serial Communications, cont’d
Control panel module responses
When a command is valid, the module performs the command and sends the following response:
[R0 {address} {echo of the command sent}]
When a command is invalid, either because the command is not recognized or contains invalid parameters, the module sends the following response:
[R1 {address} {echo of the command sent}]
Using the command/response table
The command/response table begins on page 4-13. Upper or lower case letters are acceptable in the command field. The table below shows the hexadecimal equivalent of each ASCII command.
ASCII to HEX Conversion Table
Space
Symbols, defined starting on page 4-11, are used throughout the table to represent variables in the command/response fields. Command and response examples are shown throughout the table.
Symbols
= Line feed
X1
= Address number 00 - 98 (00 addresses all units but individual units do
not respond, 97 is the factory-installed default).
The very first command that you send to the control panel module must be the connect, [CCX1], command, where X1 is the module’s address. The control panel module will not accept other commands or respond until it has been addressed.
The very last command that you send to the control panel module should be the connect, [CCX1], command, where X1 is a different address. This prevents the control panel module from accepting and responding to commands for other devices.
= Button number and string (primary or secondary) (figure 4-8)
X2
Buttons 1 and 5 are closest to the top of the CTL208. Orient the CTL208 so that the text on the rear of the unit is right-side up to determine the top of the module.
Button
number
1
2
Button
number
5
6
s must be 2-digit numbers.
X2
# Button/string
X2
# Button/string
X2
01 = 1/primary 11 = 1/secondary 02 = 2/primary 12 = 2/secondary 03 = 3/primary 13 = 3/secondary
3
7
04 = 4/primary 14 = 4/secondary
4
8
05 = 5/primary 15 = 5/secondary 06 = 6/primary 16 = 6/secondary 07 = 7/primary 17 = 7/secondary
Figure 4-8 — Button numbers
08 = 8/primary 18 = 8/secondary
= ASCII button code Up to 128 alphanumeric characters.
X3
If you need to use the bracket delimiters in a stored ASCII command, you need to use the insert brackets feature. Under this feature, one character replaces the left bracket ( [ ) and another character replaces the right bracket ( ] ). The default values are a single quote mark ( ‘ ) in place of the left bracket and a double quote ( “ ) in place of the right bracket. The CTL208 replaces the characters with the bracket delimiters in the stored ASCII or hex command string.
X4
= Bracket position 1 = left bracket, 2 = right bracket.
4-10 4-11
CTL208CM Control Panel Module • Serial Communications
CTL208CM Control Panel Module • Serial Communications
Serial Communications, cont’d
X3
= Bracket character 0 = turn off insert bracket feature. Any character
X5
other than 0 is the character that will be replaced by a bracket ( [ or ] ) when the X3 code is saved to a CTL208 button.
X6
= Hex button code Similar to the ASCII button code, X3, with the
addition of an ASCII-to-hex conversion before the value is stored. For example, if you send the ASCII value 0F, the CTL converts it to the hex value 0F. When you press the button, the CTL sends 0F hex. Entries must be in pairs, use a leading 0 if necessary. Letters must be upper case.
The insert brackets feature does not work for hex codes.
= Button mode
X7
0 = Single mode 1 = Toggle mode 2 = Press/release 3 = Continuous
= Button group number 1 or 2
X8
= Button group assignment 0 = Not assigned, 1 = Assigned
X9
Groups cannot be assigned to buttons that are set to operate in timeout mode.
X10
= Button timeout interval 0 or 1 - 255 (minutes). 0 = no timeout.
Timeouts cannot be assigned to buttons that are set to operate in groups.
= Baud rate
X11
0 = 1200 1 = 2400 2 = 4800 3 = 9600 (default) 4 = 19,200 5 = 38,400
= Parity mode: 0 = no parity (default), 1 = odd parity, 2 = even parity
X12
= Flow control mode: 0 = Xoff (default), 1 = Xon
X13
= Duplex mode: 0 = full duplex, 1 = half duplex (default)
X14
X15
= Front panel and responses: 0 = disable, 1 = enable (default) = Reset level: 0 = reset the serial port to 9600 baud, no parity, Xoff, and
X16
half duplex mode; reset the address to 97; and enable the front panel.
1 = perform all of the same resets AND erase all button
codes, reset all buttons to single mode, and reset all button groups and timeouts to 0. This reset is identical to the DIP switch reset, see Factory Reset in chapter 3, Operation.
X17
= Architectural information:
C208•{serial #}{Rev level}{firmware #}{firmware Rev level}{available baud rates}1200,2400,4800,9600,19200,38400•{2 bytes for future use}
).
.
X1
.
X3
to
X2
X4
.
X6
to
X2
character as the insert brackets
X5
unit. This command is case sensitive.
] {none} Connect the host computer to the addressed
X1
(host to CTL208) (CTL208 to host)
•] Change the CTL208’s address to
X1
•ADDR
X1
] [R0•
X1
default (97).
command string [CH3]. The ’ and ”
characters insert the delimiter brackets.
character for the left or right bracket (
brackets character for the left bracket.
]
•] Program button
X2 X3
•ADDR@•] Reset the CTL208’s address to the factory
X1
•PCLp02’CH3”•] Programs button 2’s primary code to send the
•PCLp
X1
X1
] R0•
X2 X3
?•
X2
•PCLp
X1
?] R0•
X2
•] Set the
X4 X5
•BKT
X1
] R0•
X4 X5
order {left}{right}.
•] The replacement characters are listed in the
X5 X5
•BKT
X1
hex command string 0F.
•] Program button
X2 X6
•PCHp
X1
] R0•
X2 X6
Brackets inserted using the insert brackets feature appear as brackets when you use view command.
Command/response table for programming the CTL208
C o m m a n d ASCII Command Response Additional description
Addressing
Connect [CC
Example: [ADDR95] [R0•95•ADDR95•] Change the address number to 95.
Specify address number [ADDR
Reset address to factory default [ADDR@] [R0•
Example: [PCLp02’CH3” R0•
Button code programming
Store ASCII code to a button [PCLp
View a button’s ASCII code [PCLp
Example: [BKT1’] R0•97•BKT1’] Set the single quote ( ‘ ) character as the insert
Set an insert brackets character [BKT
View insert brackets characters [BKT?] R0•
Example: [PCHp030F R0•97•PCHp030F•] Programs button 3’s primary code to send the
Store hex code to a button [PCHp
4-12 4-13
CTL208CM Control Panel Module • Serial Communications
CTL208CM Control Panel Module • Serial Communications
Serial Communications, cont’d
X9
X6
X7
X7
X9
X9
is valid between 01
X2
8
X7
7
indicates button 1’s mode,
indicates button 8’s mode.
1
8
X7
X7
X7
CTL will not send any code when the button is
pressed.
Modes in chapter 3, Operation for definitions of
the button modes.
]
•] Sets the button’s operating mode. See Button
?•
@•] Clear any codes assigned to a button. The
X2
X2
•PCHp
•PCLp
X1
X1
?] R0•
@] R0•
X2
X2
X2 X7
•SWM
X1
] [R0•
X2 X7
6
through 08 and 11 through 18.
X7
5
4
X7
3
X7
2
1
X7
•SWM011•] Set button 1 to toggle mode.
•SWM?•
X1
X1
•]
8
X9
7
indicates button 1’s group,
indicates button 8’s group.
1
8
X9
X9
X9
]
8
X9
7
X9
6
X9
5
X9
4
X9
3
X9
2
X9
1
X8 X9
6
X9
5
4
X9
3
X9
2
1
X8 X9
•SWG
X1
[R0•
Buttons 2, 7 and 8 are set to toggle mode.
Button 3 is set to press/release mode.
Button 4 is set to continuous mode.
minutes.
X10
to timeout in
]
8
X9
7
X9
indicates button 1’s group,
indicates button 8’s group.
1
8
6
X9
X9
X9
5
X9
4
X9
3
X9
2
X9
1
?•
X8
•SWG
X1
X2
•] Set button
X10
X2
•TOUT
X1
] [R0•
?] [R0•
X8
X10
X2
minutes.
X10
is set to timeout in
X2
control panel module’s serial port to
9600 baud, no parity, Xoff, and half duplex
mode. The “s” in the command and response
]
] Button
X13 X14
X10
?•
X2
•TOUT
X1
?] [R0•
X2
] Set the
s
X11 X12
CPp
CPp30s00
X1
[R0• ]
X13 X14
s
X11 X12
9600 baud, no parity, Xoff,
is a separator only.
and half duplex mode.
serial port settings:
]
] Reset the control panel module to its default @•
CPp
X1
X11 X12 X13 X14
CPp?
X1
[R0•
] @
(host to CTL208) (CTL208 to host)
Groups cannot be assigned to buttons that are not set to operate in toggle mode or are set to operate in timeout mode.
Command/response table for programming the CTL208 (continued)
4-14 4-15
Button code programming (continued)
Command ASCII Command Response Additional description
View a button’s hex code [PCHp
Reset button code (ASCII or hex) [PCLp
CTL208CM Control Panel Module • Serial Communications
Button mode programming
Set a button’s operating mode [SWM
Example: [SWM011] [R0•
View all buttons’ operating modes [SWM?] [R0•
Example: [SWM?] [R0•97•SWM?•01230011 Buttons 1, 5, and 6 are set to single mode.
Button group programming
Assign button groups [SWG
Example: [SWG11101000] [R0•97•SWG11101000•] Assign buttons 1, 2, 3, and 5 to group 1.
(host to CTL208) (CTL208 to host)
Timeouts cannot be assigned to buttons that are not set to operate in toggle mode or are set to operate in groups.
Command/response table for programming the CTL208 (continued)
C o m m a n d ASCII Command Response Additional description
Button group programming (continued)
View all buttons’ grouping [SWG
Button timeout programming
Example: [TOUT0160] [R0•97•TOUT0160•] Button 1 will timeout after 60 minutes.
Assign a timeout to a button [TOUT
CTL208CM Control Panel Module • Serial Communications
[CPp
If you change the settings, you may not be able to read the response.
Example: [CPp30s00] [R0•97•
Serial port parameters
Set the serial port parameters
View a button’s timeout [TOUT
[CPp
Reset the serial port to default
View serial port parameters [CPp?] [R0•
Serial Communications, cont’d
CTL208CM Control Panel Module
Disable the control panel module buttons. If
programmed, timeouts function normally.
]
FP0
X1
(host to CTL208) (CTL208 to host)
or disabled-to-enabled).
]
] Enable control panel module buttons.
• FP1
X1
X15
] Toggle front panel status (enabled-to-disabled
• FP
FP?
X1
X1
Control panel module does not send responses
port commands.
] Control panel module sends responds to serial
•RES1•
X1
to serial port commands.
1 = factory reset
Display the control panel module model,
revision, and connection information.
]
X17
ARC
X1
] {none} 0 = reset without reinitializing buttons,
X16
Appendix
A
Reference Information
Specifications
Parts List
Command/response table for programming the CTL208 (continued)
C o m m a n d ASCII Command Response Additional description
4-16
Front panel lockout
Disable front panel [FP0] [R0•
CTL208CM Control Panel Module • Serial Communications
Enable front panel (default) [FP1] [R0•
Toggle front panel lockout [FP] [R0•
Enable/disable responses
View front panel lockout [FP?] [R0•
Enable serial responses [RES1] [R0•
Control panel module reset
Disable serial responses [RES0] {none}
Reset control panel module [DFLT
Architectural information
View architectural information [ARC] [R0•
Reference Information, cont’d
Reference Information
Specifications
Control/remote
Serial control port ........................ 1 RS-232, RS-422, or RS-485, 5-pole captive
screw connector
Baud rate and protocol ............... 1200, 2400, 4800, 9600 (default), 19200, or
38400 baud; 8-bit; 1 stop bit; no parity (default), even parity, or odd parity; half (default)/full duplex
Pin configurations
RS-232 ................................ 3 = TX, 5 = RX, 1= Gnd
RS-422/RS-485 .................. 3 = TX+, 2 = TX-, 5 = RX+, 4 = RX-, 1 = GND
Program control .......................... Extron’s ICS100 control program for
Windows® Extron’s ASCII character set
General
Power ............................................ 9-13VDC from an auxiliary source or the
included 100VAC to 240VAC, 50/60 Hz, external, auto-switchable, 12VDC, 1 A max. power supply. Product requires 0.5 A.
Temperature/humidity .............. Storage -40° to +158°F (-40° to +70°C) /
10% to 90%, non-condensing Operating +32° to +122°F (0° to +50°C) / 10% to 90%, non-condensing
Rack mount .................................. No, but wall- or furniture-mountable with
optional CPM connector plates
Enclosure type .............................. Metal
Enclosure dimensions
Faceplate 2.8” H x 2.2” W x 0.1” D
(7.1 cm H x 5.6 cm W x 0.3 cm D)
Device ..... 2.8" H x 1.9" W x 1.4" D
(7.1 cm H x 4.8 cm W x 3.6 cm D)
(Depth excludes buttons.)
Product weight ............................. 0.25 lb (0.1 kg)
Shipping weight ........................... 2 lbs (0.9 kg)
Vibration ....................................... ISTA/NSTA 1A in carton (International
Safe Transit Association)
Listings .......................................... ETL (UL1950), UL, CUL
Compliances ................................. CE, FCC Class A
MTBF ............................................. 30,000 hours
Warranty ....................................... 3 years parts and labor
Parts List
Included parts
Description Part number
CTL208CM (black) 60-576-10 CTL208CM (white) 60-576-40
or
12VDC, 1 A power supply kit 70-055-01 IEC power cord 27-044-01 Tweeker (small screwdriver) 100-014-01 ICS100 Control Software CTL208 Control Panel Module manual
Mini-AAP mounting options
Wall mounting solutions
Description Part number
CPM101B (one-gang) (black) 60-583-11 CPM101W (one-gang) (white) 60-583-21 CPM102B-1 (two-gang) (black) with cable guards 60-583-12 CPM102W-1 (two gang) (white) with cable guards 60-583-22 CPM102B-2 (two-gang) (black) without cable guards 60-583-13 CPM102W-2 (two-gang) (white) without cable guards 60-583-23 CPM103B-1 (three-gang) (black) with cable guards 60-583-14 CPM103W-1 (three-gang) (white) with cable guards 60-583-24 CPM103B-2 (three-gang) (black) without cable guards 60-583-15 CPM103W-2 (three-gang) (white) without cable guards 60-583-25 CPM104B-1 (four-gang) (black) with cable guards 60-583-16 CPM104W-1 (four-gang) (white) with cable guards 60-583-26 CPM104B-2 (four-gang) (black) without cable guards 60-583-17 CPM104W-2 (four-gang) (white) without cable guards 60-583-27
A-2
Specifications are subject to change without notice.
CTL208CM Control Panel Module • Reference Information
CTL208CM Control Panel Module • Reference Information
A-3
Reference Information, cont’d
Architectural solutions
Description Part number
RGB 468 Mxi (black) 60-591-02 RGB 468 Mxi (white) 60-591-03 CIA111 (black, with cable guards) CIA111-1 CIA111 (white, with cable guards) CIA111-2 CIA111 (black, without cable guards) CIA111-3 CIA111 (white, without cable guards) CIA111-4 CIA112 (black, with cable guards) CIA112-1 CIA112 (Inline white, with cable guards) CIA112-2 CIA112 (black, without cable guards) CIA112-3 CIA112 (Inline white, without cable guards) CIA112-4 RGB 478 Mxi (black) 60-592-02 RGB 48 Mxi (white) 60-592-03
Table solutions
Description Part number
CPM208-1 Mini-AAP bay 60-589-13 CPM212-1 Tabletop mini-AAP bay (black) 60-590-11 CPM212-2 Tabletop mini-AAP bay (white) 60-590-21
Wall mounting harware
Description Part number
One-gang “J” box, 2.5” deep 980130 Two-gang “J” box, 2.5” deep 980084 Three-gang “J” box, 2.5” deep 980083 Four-gang “J” box, 2.5” deep 980097 One-gang mounting bracket IN9181
A-4
CTL208CM Control Panel Module • Reference Information