CS 26T • Setup Guide
This setup guide contains installation information about the CS 26T speaker cartridge for the Extron CS 1226T Cartridge Speaker
System. The CS 26T can be installed as a standalone speaker or in conjunction with the CS 120P plenum rated enclosure. When
a CS 26T speaker is installed in a CS 120P enclosure, the entire assembly is plenum rated.
WARNING: May result in serious injury. Installation and service must be performed by authorized personnel only.
NOTE: Installation of conduit and conduit adapters must conform to all applicable building codes and local ordinances.
Installing the CS 26T in a Suspended Ceiling
For hard ceiling installations, see the CS 26T User Guide.
1. Remove power from all devices.
NOTE: If the baffle and grille are to be painted, see
the CS 26T and CS 120P User Guide for more
information.
2. Cut a hole for the CS 26T. Use the provided cutout
template to outline the hole to be cut in the ceiling tile as
described below.
a. Remove the ceiling tile, and draw diagonal lines
across it from opposite corners to locate its center.
Mark the intersection where the lines cross.
b. Position the center hole of the cutout template
directly over the center of the tile, marked in
step2a.
c. Trace a circle on the ceiling tile as follows:
For installations in ceilings that are NOT
fiberglass or when installing the speakers
in an open back configuration: Trace a circle
around the CS 26T cutout template.
NOTE: The fiberglass tile adapters are not
needed and can be discarded.
For installations in a fiberglass ceiling with
the CS 120P:
NOTE: A set of fiberglass tile adapters is
provided with both the CS 26T and the
CS 120P. Only one set is needed to install the
CS 26T with the CS 120P kit in fiberglass tile.
i. Place the berglass tile adapter around the
outer diameter of the template that was
positioned in step 2b.
ii. Trace a circle around the outer diameter of the
adapter.
d. Cut out the circle traced in the ceiling tile.
e. Replace the ceiling tile in the ceiling.
3. Remove the adjacent ceiling tile next to the tile
where the speaker will be installed.
4. Install the CS 120P or ceiling mount kit (part
number 70-996-01).
• If using the CS 120P, see the CS 120P Setup
Guide to install it.
• If not using the
C-ring
CS120P, attach two
V-rails and one C-ring
across the tile above
the hole cut in step 2
V-rail
(see the illustration at
right). The berglass
tile adapter is not needed.
5. Route the speaker wires through the ceiling tile hole.
6. Remove the grille carefully from the CS 26T.
NOTE: Grille hooks are provided for grille removal, if
needed.
7. Congure the bass reex port plate. By default, the
CS 26T is set up for use with the CS 120P. If not using
the CS 120P, set the plate for an open-back installation.
• With the CS 120P: Leave the plate in its default
location. The port must be left uncovered (see A in
the diagram below).
• Open back: The bass reex port is uncovered by
default. In the open back conguration (without the
CS 120P), this port must be closed (covered). If the
port is not covered:
a. Use a Phillips screwdriver to remove the two
screws securing the bass reex port plate in its
storage location.
b. Attach the plate to the bass reex port using
the two screws that you removed in step 7a
(see B in the diagram below).
Screws (2)
Bass Port Plate
(storage location)
Bass Reflex Port
(open, uncovered)
Bass Reflex Port
(closed, covered)
CS 26T • Setup Guide (Continued)
8. Attach speaker wires from the ceiling tile hole to the
included 4-pole captive screw connector using one of
the following three methods:
a
Power Amplifier
Wiring Multiple Speakers Using Loop-through
When a chain of speakers is wired in this configuration,
disconnecting one speaker removes power from all speakers.
b
Power Amplifier
Wiring Multiple Speakers in Parallel
When a chain of speakers is wired in this configuration,
disconnecting one speaker does not remove power from the
remaining speakers in the chain.
c
Power Amplifier
Wiring a Single Speaker
(Red)
(Black)
(Red)
(Black)
(Red)
(Black)
–
–
LOOP
IN
Speaker 1
–
–
LOOP
IN
Speaker 1
–
–
LOOP
IN
Speaker 1
(Red)
(Black)
–
–
+
+
IN
LOOP
LOOP
IN
(Red)
(Black)
+
+
IN
LOOP
Speaker 2
(Red)
(Black)
–
+
+
IN
LOOP
LOOP
(Red)
(Black)
+
+
–
IN
LOOP
IN
Speaker 2
Wire Gauge Table
Number of Wires per
Connection Point
+
+
IN
LOOP
1 12 AWG
2 16 AWG
4 18 AWG
NOTES:
• See the wire gauge table above for the
maximum number of wires per terminal.
• Do not tin the wires. Tinned wires do not hold
tight in the captive screws and can break
easily after several bends.
• See the CS 26T and CS 120P User Guide for
detailed information on wiring congurations.
9. Insert the captive screw plug into the four-pole
receptacle on the speaker crossover board.
10. Secure the speaker wire to the strain relief
tie-down point, using the included zip tie.
Secondary
Support Line
Maximum
Wire Gauge
11. Mount the CS 26T.
a. Insert the CS 26T through the bottom of the hole in
the ceiling tile that was cut in step 2.
b. Tighten the four screws (clockwise) until the
speaker is securely clamped to the ceiling.
ATTENTION: Do not overtighten the screws.
12. Attach secondary support lines if required (see the
gure in step 10). If using the CS 120P, see the CS 120P
Setup Guide for details.
ATTENTION: Do not allow any slack in the
secondary support line.
13. Replace the adjacent tile that was removed in step 3.
14. Set the rotary tap selector switch to the appropriate
setting, using a small screwdriver.
2W
100 V
4W
8W
16W
15. Install the grille. Position the outer perimeter of the
16W
8Ω
8W
4W
2W
8Ω
70 V
1W
grille into the groove of the speaker bafe. Six magnets
pull the grille securely into place.
Zip Tie
Strain Relief Tab
Extron Headquarters
+1.800.633.9876 (Inside USA/Canada Only)
Extron Europe
+31.33.453.4040
© 2013 Extron Electronics — All rights reserved. All trademarks mentioned are the property of their respective owners. www.extron.com
Extron Asia
+65.6383.4400
Extron Japan
+81.3.3511.7655
Captive Screw
Connector
Speaker Grille
NOTE: Grille hooks are provided for removal of the
grille after installation.
Extron China
+86.21.3760.1568
Extron Middle East
+971.4.299.1800
Extron Korea
+82.2.3444.1571
Extron India
+91.80.3055.3777
68-2161-51 Rev. B
03 13