WARNING: This symbol, , when used on the product, is intended to
alert the user of the presence of uninsulated dangerous voltage within
the product’s enclosure that may present a risk of electric shock.
ATTENTION: This symbol, , when used on the product, is intended to alert
the user of important operating and maintenance (servicing) instructions in the
literature provided with the equipment.
For information on safety guidelines, regulatory compliances, EMI/EMF
compatibility, accessibility, and related topics, see the Extron Safety and
Regulatory Compliance Guide, part number 68-290-01, on the Extron
website, www.extron.com.
Instructions de sécurité • Français
AVERTISSEMENT: Ce pictogramme, , lorsqu’il est utilisé sur le
produit, signale à l’utilisateur la présence à l’intérieur du boîtier du
produit d’une tension électrique dangereuse susceptible de provoquer
un choc électrique.
ATTENTION: Ce pictogramme, , lorsqu’il est utilisé sur le produit,
signale à l’utilisateur des instructions d’utilisation ou de maintenance
importantes qui se trouvent dans la documentation fournie avec le
matériel.
Pour en savoir plus sur les règles de sécurité, la conformité à la
réglementation, la compatibilité EMI/EMF, l’accessibilité, et autres sujets
connexes, lisez les informations de sécurité et de conformité Extron, réf. 68290-01, sur le site Extron, www.extron.fr.
Sicherheitsanweisungen • Deutsch
WARNUNG:Dieses Symbol auf dem Produkt soll den Benutzer darauf
aufmerksam machen, dass im Inneren des Gehäuses dieses Produktes
gefährliche Spannungen herrschen, die nicht isoliert sind und die einen
elektrischen Schlag verursachen können.
VORSICHT: Dieses Symbol auf dem Produkt soll dem Benutzer
in der im Lieferumfang enthaltenen Dokumentation besonders
wichtige Hinweise zur Bedienung und Wartung (Instandhaltung)
geben.
『Extron Safety and Regulatory Compliance Guide 』 (P/N 68-290-01) をご覧ください。
Weitere Informationen über die Sicherheitsrichtlinien, Produkthandhabung,
EMI/EMF-Kompatibilität, Zugänglichkeit und verwandte Themen finden Sie
in den Extron-Richtlinien für Sicherheit und Handhabung (Artikelnummer 68290-01) auf der Extron-Website, www.extron.de.
Instrucciones de seguridad • Español
ADVERTENCIA: Este símbolo, , cuando se utiliza en el producto,
avisa al usuario de la presencia de voltaje peligroso sin aislar dentro
del producto, lo que puede representar un riesgo de descarga
eléctrica.
ATENCIÓN: Este símbolo, , cuando se utiliza en el producto, avisa
al usuario de la presencia de importantes instrucciones de uso
y mantenimiento recogidas en la documentación proporcionada
con el equipo
Para obtener información sobre directrices de seguridad, cumplimiento
de normativas, compatibilidad electromagnética, accesibilidad y temas
relacionados, consulte la Guía de cumplimiento de normativas y seguridad de
Extron, referencia 68-290-01, en el sitio Web de Extron, www.extron.es.
.
Korean
경고: 이 기호 , 가 제품에 사용될 경우, 제품의 인클로저 내에 있는
접지되지 않은 위험한 전류로 인해 사용자가 감전될 위험이 있음을
경고합니다.
주의: 이 기호 , 가 제품에 사용될 경우, 장비와 함께 제공된 책자에 나와
있는 주요 운영 및 유지보수(정비) 지침을 경고합니다.
안전 가이드라인, 규제 준수, EMI/EMF 호환성, 접근성, 그리고 관련
항목에 대한 자세한 내용은 Extron 웹 사이트(www.extron.co.kr)의
Extron 안전 및 규제 준수 안내서, 68-290-01 조항을 참조하십시오.
FCC Class A Notice
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to part15 of the FCC rules. The ClassA limits provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause interference; the user must correct the interference at
his own expense.
NOTE: For more information on safety guidelines, regulatory compliances, EMI/EMF compatibility,
accessibility, and related topics, see the “Extron Safety and Regulatory Compliance
Ceiling — Division of Labor .............................. 15
Installing the CS 26T in a Suspended
Ceiling — Division of Labor .............................. 20
Installing the CS 120P in a Hard Ceiling ............ 26
CS 26T and CS 120P User Guide • Contentsv
CS 26T and CS 120P User Guide • Contentsvi
Introduction
This section gives an overview of the Extron CS 1226T SpeedMount Ceiling Speaker
System, consisting of the CS 26T speakers and CS 120P enclosure. It also provides a list of
system features and an application diagram. Topics include:
• About this Guide
• Overview
• Features
• Application Example
About this Guide
This guide describes the Extron CS 1226T Speaker System, the CS 26T speaker pair and
the CS 120P enclosure and provides instructions for installing all components of the system
in different types of ceilings.
Overview
The CS 1226T system features a low profile design that houses a 6.5-inch woofer and a
0.75-inch tweeter (CS 26T) contained in a UL 2043 rated enclosure (CS 120P) designed for
use in plenum rated ceiling spaces.
This unique speaker system splits installation into two phases, rough-in and finish, allowing
the installer to “reserve” space for the speaker system by installing the CS 120P back can
and then later installing the CS 26T speaker. This two-step process (division of labor) is
especially useful when multiple installers are involved. The CS 120P can be installed by the
low voltage contractor while the CS 26T can be installed by the AV systems contractor.
Features
• US and metric ceiling grids — The CS 120P enclosure can be installed in both U.S.
and metric ceiling grid systems (for metric systems, the CS 120P end tabs are cut off).
• UL 2043 listed — The CS 1226T is UL 2043 listed (only when the CS 26T is used with
the CS 120P).
NOTE: The use of any other back can other than the CS 120P or those provided by
Extron voids the UL 2043 rating.
• Optional open back configuration — The CS 26T can be used without the CS 120P
by reconfiguring the attached bass port plate (allowing the CS 26T to function as an
open back speaker).
NOTE: When the CS 26T is used without the CS 120P, it is not suitable for air
handling spaces and is not UL 2043 rated.
• New dog-leg design — The new dog-leg design eliminates jamming during
installation.
• Low profile enclosure — The low profile enclosure is compatible with plenum
environments where overhead space may be limited.
CS 26T and CS 120P User Guide • Introduction1
Application Example
• Selectable taps — The rotary tap selector switch, located behind the grille, sets the
speaker to operate in either 8-ohm direct or 70 volt /100 volt operation with 16, 8, 4, 2,
and 1 watt taps.
• Magnetic grille — Magnets spaced around the grille edge enable it to be easily
attached and to remain firmly in place.
The illustration below is one example of configuring a system using the CS 1226T.
Desk Microphones
VCR
DVD
DOC
CAM
LAPTOP
PC
ON
OFF
DISPLAY
MUTE
SCREEN
UP
SCREEN
DOWN
TCP/IP
Network
LAN
POWER12V500mAMAX
RS-232
COM1
RT SC TS
RX
TX
INPUT
1234
Ethernet
RELAY
1
2
IR
1
COM 2
G
RELAY
TXRX
3
SG S
IR
4
3
COM 3
G
TXRX
SG S
2
4
3
YC
1
VID
I
Y
N
VID
100-240V 50-60Hz
4
P
U
2
T
Extron
IN1508
Scaling Presentation
Switcher
XPA 2003C-70V
GREEN - ACTIVEAMBER - STANDBY
100-240V 1.5A, 50-60 Hz
RS-232
OUTPUT
A
R
B
L
L
6
5
R
8
7
34
AUDIO INPUT
2
1
L
OUTPUT
R
RGB
LISTED1T23
US
I.T.E.
Y, B-Y, R-Y
C
6
8
DVI
RGB
7
RGB
R-Y
5
B-Y
Extron
TLP 700TV
7" TouchLink
Tabletop
Touchpanel
Extron
OUT
MIC/LINE INPUTS
P
3
U
MIC
T
+48V
S
3
2
6
1
5
6
4
IPL 250
IP Link Control
Processor
DMP 64
RS-232(1)
RESET
LAN
I/O
RxxT
2
3
RS-232(2)
12
1
6
45
RxTx
4
3
Laptop
PC
2
1
5
4
ExtronDMP 64
POWER
12V
1.5A MAX
Digital MatrixProcessor
70 V3
OUTPUTS
8Ω / 4Ω12
HPF
CLASS 2 WIRING
80Hz
OFF
33
INPUTS
2
1
3
ATTENUATION
8
10
6
2
12
4
8
14
2
10
6
1
12
4
0
8
14
2
10
6
∞
12
4
0
14
2
LIMITER/
∞
REMOTE
18
3
0
PROTECT
2
26
∞
1
STANDBY
G
SIGNAL
Extron
XPA 2003C 70V
ComboPower Amplier
Extron
CS 1226T
SpeedMount Ceiling
Speaker System
Extron
SI 26
Surface-Mount
Speakers
Figure 1. Application Diagram of a CS 1226T Installation
CS 26T and CS 120P User Guide • Introduction2
Installation
This section provides instructions for installing the CS 26T speakers and the CS 120P
enclosure. Topics include:
• Installation Considerations
• Installation Configurations
• Installing the CS 1226T — Single Installer
• Installing the CS 120P in a Suspended Ceiling — Division of Labor
• Installing the CS 26T in a Suspended Ceiling — Division of Labor
• Installing CS 120P in a Hard Ceiling
Installation Considerations
WARNING: Risk of severe bodily injury from falling or sharp equipment.
Installation and service must be performed by authorized personnel only.
• All wiring and electrical connections must conform to all applicable building codes and
local ordinances.
• Installation in a plenum-rated environment requires plenum rated cable or conduit.
• If using secondary support cables, the installer provides the cables.
Installation Configurations
The CS 26T can be configured in the following ways:
• Open-back: For configurations in which the CS 120P is not used, use the C-ring
accessory, available at www.extron.com. The C-ring spreads out the clamping force of
the dog-legs when used in drop ceilings and gypsum ceilings.
• Using the CS 120P: When used with the CS 120P, the CS 26T can be placed in
plenum environments. This is the only configuration that is UL 2043 rated.
NOTE: The CS 120P can be ordered separately or as part of the CS 1226T kit.
For hard ceiling installations, see Installing the CS 120P in a Hard Ceiling on
page 26.
CS 26T and CS 120P User Guide • Installation3
Installing the CS 1226T System — Single Installer
Side View
If a single installer is installing the CS 1226T system, follow this procedure for the entire
system:
NOTE: The ceiling grid must be installed before the installation of the CS 1226T begins.
• Verify if fiberglass ceiling tiles are being used (see step 2 below and step11 on
page 7 for details).
• The grid face must be at least 15/16 inch (24 mm) for proper installation of the
CS 120P (see step20 on page 13 for details on suspending the enclosure on a
smaller grid face).
15/16" (24 mm)
Grid Face
Figure2. GridFaceExample
1. Disconnectpower — Power down all attached devices before proceeding.
2. Verifythespacewherethesystemwillbeinstalled — Ensure that there is sufficient
clearance above the ceiling tile for the unit to be installed.
3. CutaholefortheCS26Tspeaker—Use the provided cutout template to outline
the hole to be cut in the ceiling tile as described below.
a. Remove the ceiling tile.
b. To find the center of the tile, use a tape measure to measure the space between
two opposite corners, and mark the half-way point.
c. Position the center hole of the cutout template directly over the center of the tile
that you marked in step3b.
d. Using the provided cutout template, trace a circle on the ceiling tile as follows:
ForinstallationsinceilingtilesthatareNOTfiberglassorwheninstalling
thespeakersinanopenbackconfiguration: Trace a circle around the CS 26T
cutout template.
NOTE: The fiberglass tile adapters are not needed and can be discarded.
NOTE: A set of fiberglass tile adapters is provided with both the CS 26T and
the CS 120P. Only one set is needed to install the CS 26T with the CS 120P
kit in a 1-inch (0.25 cm) thick fiberglass tile. The adapter works only with
1-inch (0.25 cm) thick fiberglass tile.
i. Place the fiberglass tile adapter around the outer diameter of the template that
was positioned in step 3c.
ii. Trace a circle around the outer diameter of the adapter.
CS26TandCS120PUserGuide•Installation4
Loading...
+ 23 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.