Extron electronic Cable Cubby 200, Cable Cubby 800, Cable Cubby 300C, Cable Cubby 600, Cable Cubby 300S User Manual

User’s Manual
www.extron.com
Extron Electronics, USA
1230 South Lewis Street Anaheim, CA 92805 USA
714.491.1500 Fax 714.491.1517
Extron Electronics, Europe
Beeldschermweg 6C 3821 AH Amersfoort The Netherlands +31.33.453.4040 Fax +31.33.453.4050
© 2006 Extron Electronics. All rights reserved.
Extron Electronics, Asia
135 Joo Seng Road, #04-01 PM Industrial Building Singapore 368363 +65.6383.4400 Fax +65.6383.4664
Extron Electronics, Japan
Kyodo Building 16 Ichibancho Chiyoda-ku, Tokyo 102-0082 Japan +81.3.3511.7655 Fax +81.3.3511.7656
Cable Cubby® 200
Cable Cubby
Cable Cubby
Cable Cubby Cable Cubby
Surface Access Products for Cables, AAPs, and Power Outlets
®
300C
®
300S
®
600
®
800
68-701-01 Rev. F
06 06
i
Table of Contents
Chapter One • Introduction .................................................... 1-1
About the Cable Cubby® Products ....................................... 1-2
Features ........................................................................................ 1-5
Chapter Two • Installation ...................................................... 2-1
Installation Overview ............................................................... 2-2
Preparing the Routing Template .......................................... 2-3
Preparing the Table ................................................................... 2-4
Preparing the table with a router ......................................... 2-4
Preparing the table with a hole saw
(Cable Cubby 300C only) ....................................................... 2-6
Installing the Cables and AAPs ............................................. 2-7
AAP shelf brackets (CC 300, 600, 800) .................................. 2-7
Installing the power module (CC 300, 600, 800) .................. 2-8
Installing the cables ............................................................... 2-8
Installing the AAPs ................................................................. 2-9
Installing the shelf assembly (CC 300, 600, 800) ................ 2-10
Adjusting the cable position (CC 200) ................................ 2-10
Mounting the Cable Cubby .................................................. 2-11
Chapter 3 • Maintenance and Modifi cations ............. 3-1
Removing and Replacing the Cable Cubby ....................... 3-2
Replacing Cables or an AAP ................................................... 3-5
Adding an Additional Power Module
(CC 600 and CC 800) .................................................................. 3-6
Appendix A • Reference Information ..............................A-1
Specifi cations ..............................................................................A-2
Cable Cubby Part Numbers ....................................................A-7
Included Parts .............................................................................A-8
Replacement/Modifi cation Part Numbers .........................A-9
Routing Template Part Numbers ........................................A-11
Top Plate Dimensions .............................................................A-11
Appendix B • Packaging for Shipment ........................... B-1
®
Cable Cubby
Products • Table of Contents
i
Table of Contents, cont’d
Cable Cubby® Products
Chapter One
1
68-701-01 Rev. F
All trademarks mentioned in this manual are the properties of their respective owners.
®
ii
Cable Cubby
Products • Table of Contents
Introduction
About the Cable Cubby® Products
Features
06 06
Introduction
About the Cable Cubby® Products
The Extron Cable Cubbies are furniture-mounted, architectural solutions for inconspicuous cable access and connection points. When cables are not in use, they can be stored out of the way while remaining connected to the presentation system.
Most US/domestic Cable Cubby models provide two unswitched USA AC power outlets. The US/domestic Cable Cubby 200 provides one outlet. Each of the international versions provides a single unswitched AC power outlet appropriate to the region where the Cable Cubby is sold. Several different types of power receptacles are available for the international version, including UK, French, Israeli, Australian, Indian, European, and Swiss receptacles.
The four different sizes of Cable Cubbies provide room for the indicated number of Extron’s Architectural Adapter Plates (AAPs):
Cable Cubby 800 USA/domestic model — Eight single-
space (single-height) AAPs
Cable Cubby 800 (international model) — Seven single-
space (single-height) AAPs
Cable Cubby 600 USA/domestic model — Six single-
space AAPs
Cable Cubby 600 (international model) — Five single-
space AAPs
Cable Cubby 300 USA/domestic model — Three single-
space AAPs
Cable Cubby 300S — Square cover (fi gure 1-1)  Cable Cubby 300C — Circular (round) cover
Cable Cubby 300 (international model) — Two single-
space AAPs
Cable Cubby 300S — Square cover  Cable Cubby 300C — Circular (round) cover
Cable Cubby 200 (all models) — Two single-space AAPs
Figure 1-1 — Cable Cubby 300S US/domestic enclosure
The AAP spaces inside the cubbies allow you to customize the enclosure to meet your unique needs, with the included split double space AAPs and Extron’s full line of optional passive AAPs. The split AAPs can store almost any type of cable you might encounter. The line of passive AAPs allows you to customize the AAP with almost any kind of pass-through connectivity you may need.
The elevation of the AAPs inside the cubby and the arrangement of the AAPs and the power outlets are adjustable to suit cable lengths and connector types.
N
The elevation and arrangement of the power outlet
and AAPs in the Cable Cubby 200 are fi xed and not customizable.
1-2 1-3
Cable Cubby® Products • Introduction
Cable Cubby® Products • Introduction
Introduction, cont’d
The installed Cable Cubbies fi t nearly fl ush within a table or podium top, storing the AAPs and cables out of the way and out of sight. To access the AAPs and connectors, lift the lid (fi gure 1-2). Half-moon cutouts in the lid allow you to run cables in or out and then close the lid. For Cable Cubby 300s, 600s, and 800s, you can lower the lid into its recessed position.
Extron Cable Cubby 800
Hideaway Cable Access Enclosure
15-pin HD Cable
Audio Cable, Network Cable
Mounted
through a table
or podium
Figure 1-2 — Typical Cable Cubby 800 application
The Cable Cubby 300 is available with either a round or a rectangular top. The other cubbies all have rectangular tops only. Preparing the table to install a Cable Cubby 300C (round) requires simply drilling a hole in the table with a 6-inch hole saw (fi gure 1-3). Preparing the table to install a square cubby requires routing a square hole in the table top. Sheet metal routing templates are available on request for all models at no cost.
Features
Easy access to cables and AAPs
Durable mechanical movement
Cable Cubby 300, 600, and 800 available in a variety of surface fi nishes
• Compact size
Flexible installation of Extron passive AAPs
• Grounded AC receptacle(s)
• UL/CUL listing
• CSA certifi cation
1-4
1
2 3
Figure 1-3 — Cable Cubby 300C mounting
Cable Cubby® Products • Introduction
Cable Cubby® Products • Introduction
1-5
Introduction, cont’d
Cable Cubby® Products
Chapter Two
2
1-6
Installation
Installation Overview
Preparing the Routing Template
Preparing the Table
Installing the Cables and AAPs
Mounting the Cable Cubby
Cable Cubby® Products • Introduction
Installation
Installation Overview
Install and set up the Cable Cubby enclosures as follows:
1
If you plan to use a mounting template that has not been
prepared, prepare the template. See Preparing the Routing Template, later in this chapter.
2
Cut a hole in the surface where the enclosure will be
installed. See Preparing the Table, later in this chapter.
3
Run all cables necessary to support the AC connector,
the cables stored in the cubby, and all planned AAP connectors. Leave enough slack in the cables to connect or route them before the cubby is installed in the table.
4
If applicable, install the power module. If your location
requires electrical conduit, install an Extron fl exible conduit kit. Refer to the Flexible Conduit Kit Installation Guide, Extron part #68-734-01.
5
Install all desired cables into the cable pass-through (split)
AAPs and install the AAPs into the Cable Cubby. See Installing the Cables and AAPs, later in this chapter.
6
If applicable, connect cables to the rear connectors on
the passive AAPs and install the AAPs in the cubby. See Installing the AAPs, later in this chapter.
7
Mount the Cable Cubby in the table. See Mounting the
Cable Cubby, later in this chapter.
8
Peel the protective fi lm from the top surface.
9
Connect the Cable Cubby power cord.
Preparing the Routing Template
Extron provides metal templates for the Cable Cubbies at no charge. See Routing Template Part Numbers, in appendix A, Reference Information, for part numbers. Extron recommends using this template as a guide to cut the hole in the table where the cubby will be installed.
N
1. Cut 1/2" x 4" strips of soft, fi nished lumber at least
These strips raise the routing template above the mounting
C
The metal routing template is reusable. Do not discard
this template when the installation is complete. Save it for installing Cable Cubby models of the same size.
long enough to span the distance between the desired installation location on the mounting surface and the edges of the mounting surface (fi gure 2-1).
surface to provide room for the router’s collar, protect the mounting surface, and extend the routing template’s reach so that it can be clamped to the edge of the surface.
Do not allow the wood screws to protrude through
the bottom of the wooden strips. Protruding screws will mar the table when the template is used.
Width of Mounting Surface
Minimum 4 Screws
Mounting Surface Edge
Wood Strips
Wood Strip Height 4" / 10.2 cm
Mounting Surface Edge
Wood Thickness
0.5" / 1.3 cm
Routing Template
Figure 2-1 — Prepared CC 300 mounting template
2. Using four or more short wood screws, secure the
mounting template to the lumber strips.
2-2 2-3
Cable Cubby® Products • Installation
Cable Cubby® Products • Installation
Installation, cont’d
Preparing the Table
The preferred and recommended method for preparing the table for square Cable Cubbies and one of two preferred methods for the Cable Cubby 300C is to use the appropriate Extron routing template and a router.
For the Cable Cubby 300C, another preferred method is to use a 6" hole saw.
Alternatively, for any model, you can use a paper cut-out template (see appendix A) and a sabre saw or keyhole saw, but this method is not recommended.
C
Preparing the table with a router
Prepare the table with a router as follows:
C
The opening in the table for the Cable Cubby should
be cut only by licensed and bonded craftspeople. Exercise care to prevent scarring or damaging the furniture.
The surfaces of the Cable Cubby enclosure have screws and other protruding hardware that could damage fi ne furniture. Do not rest the enclosure on unprotected furniture.
The routing templates for the various Cable Cubbies
are not interchangeable. If you use the wrong template, you will cut an improperly-sized hole. If you use a larger template than required, the cut will result in gaps in the table surface on either side of the enclosure.
W
4. Using a router with a 5/8" (or 16 mm) outside diameter
guide bushing and a 1/2" (or 12 mm or 12.7 mm) diameter straight router bit, carefully cut the opening in the surface (fi gure 2-2).
Figure 2-2 — Cutting the opening with a router
5. Remove the C-clamps and the routing template.
Wear safety glasses when operating the router.
Failure to comply can result in eye injury.
2-4
C
N
1. Locate the desired mounting location on the tabletop or
2. Place the mounting template assembly on the table,
3. Once the template assembly is positioned properly, secure
Ensure that only the wooden strips on the routing
template contact the furniture. Failure to do so may mar the furniture.
The metal routing template is reusable. Do not discard
the template when the installation is complete. Save it for installing other Cable Cubbies of the same size.
other installation surface. Mark the location.
centered on the mounting location. Angle the template for the optimum positioning. If necessary, use a square to ensure that the template is properly positioned. Extron is not responsible for improperly positioned Cable Cubbies.
the assembly to the table with C-clamps.
Cable Cubby® Products • Installation
Cable Cubby® Products • Installation
2-5
Installation, cont’d
Preparing the table with a hole saw (Cable Cubby 300C only)
Prepare the table with a hole saw as follows:
1. On the tabletop or other installation surface, mark the 6"
circle, then fi nd and mark the center of the circle.
W
2. Using a portable drill with a 6" (or 152 mm) hole saw,
carefully cut the opening in the table surface at the desired location (fi gure 2-3). Extron is not responsible for improperly positioned Cable Cubbies.
C
Wear safety glasses when operating the drill.
Failure to comply can result in eye injury.
Use a portable drill with suffi cient power to handle
the 6” hole saw. Exercise caution when handling the drill and hole saw. Take care to protect the mounting surface from damage.
Installing the Cables and AAPs
Each Cable Cubby 300, 600, and 800 model ships with one or two moveable AAP shelf assemblies. The Cable Cubby 200’s AAP shelf is fi xed in place.
AAP shelf brackets (CC 300, 600, 800)
Each shipped AAP shelf assembly consists of a set of shelf brackets and a number of cable pass-through (split) AAPs. Depending on the Cable Cubby model, each set of shelf brackets supports either two, three, or four single-space AAPs (fi gure 2-4).
Four-Space Shelf Bracket
and Split AAPs
Three-Space Shelf Bracket
and Split AAPs
Two-Space Shelf Bracket
and Split AAPs
2-6
Figure 2-3 — Cutting the opening with a hole saw
Cable Cubby® Products • Installation
Figure 2-4 — Shelf brackets
The simplest way to install the cables and AAPs in the Cable Cubby 300, 600, and 800 is to populate the shelf brackets with split and/or standard AAPs outside the cubby and then install the populated AAP shelf assembly into the cubby.
N
Cable cubby 300, 600, and 800 only —
On US/domestic models, the power module takes up two AAP spaces. On IEC, EU, Swiss, UK, Israeli, and Australian models, the power module takes up three AAP spaces. Cable pass-through AAPs take two, three, or four AAP spaces. Consider the arrangement of the Cable Cubby AAPs when you install them so that you do not waste AAP space.
Cable Cubby® Products • Installation