Extron DTP T UWP 4K D User Manual

IMPORTANT:
Go to www.extron.com for the complete
user guide, installation instructions, and
specifications before connecting the
product to the power source.
DTP T UWP 4K D Series • Setup Guide
V
Projector
Signal Output Cable
Cable Clamp
Decora Faceplate
Extron DTP HWP 232 D
Screws or
Nails Wall opening is flush with edge of box.
Wall Stud
AUTO SW
CONFIG
HDCP
1
IR OUT
HDMI IN
AUDIO IN
S
G
AUDIO IN
This setup guide provides instructions for an experienced installer to set up and operate the Extron DTP T UWP 4K D series of Twisted Pair (TP) wallplate extenders.
1 2 3 4 5 6 7 8
CONFIG
E
1
3
CONFIGURABLE
100-240V ~ -- A MAX
2
4
50/60 Hz
IN1608
INPUTS
INPUTS
5
HDMI
6
SIGNAL
HDCP
IN1608 SA
OVER DTP
RS-232 IR
C
TxRx TxRxG
7
8
SIG LINK
SIG LINK
SIG LINK
OVER DTP
OVER DTP
HDMI
RS-232 IR
RS-232 IR
DTP OUT
TxRx TxRxG
DTP IN
DTP IN
TxRx TxRxG
Installation
Step 1 — Disconnect Power
Disconnect all equipment power sources.
Step 2 — Prepare the Mounting Surface
AUTO SW
AUDIO IN
AUDIO IN
HDCP
1
VGA IN
HDMI IN
CONFIG
Extron DTP T UWP 4K 232 D
Transmitter
XTP DTP 24 Cable 230'
INPUTS
1
2 3 4 5 6 7 8 A B C
OUTPUTS
A
HDMI
B
OUTPUTS
MENU
VOLUME
ENTER
IN1608
SCALING PRESENTATION SWITCHER
AMPLIFIED OUTPUT
2x25W(8Ω)/2x50W(4Ω)
L3R
AUDIO INPUTS
OUTPUTS
LL1R R
L5R
12
CLASS 2 WIRING
REMOTE
LAN
+48V
MIC/LINE
VARIABLE
RESET
L2
L4
R
R
RS-232
L6
LR
R
2
+48V
TxRx
DTP HDMI 4K 230 Rx
IPCP 505
COM
SWITCHED
12VDC
LIMIT
2
R
G
314
TXRXTX
OVER
12345678
IPCP 505
SIG LINK
POWER 12V
0.7A MAX
DTP IN
Wall opening is flush with edge of box.
RTS
IR/S
CTS
4
RX
5162738
Ethernet
OUTPUTS
Wall Stud
Screws or Nails
RELAY
5162314
LR
FLEX
100
eBUS
I/O
ACT LIMIT
2
4
OVER
738
Network
LINK
IR
ACT
TLP 1000T
AUDIO
HDMI
ATTENTION:
Installation and service must be performed by
authorized personnel.
L’installation et l’entretien doivent être effectués
par le personnel autorisé uniquement.
The unit must be installed in accordance with the
Cable Clamp
AUDIO IN
AUTO SW
HDCP
1
VGA IN
AUDIO IN
CONFIG
HDMI IN
National Electrical Code and with local electrical and safety codes.
Signal Output Cable
Extron DTP UWP 4K 232 D
L’unité doit être installée conformément au
National Electric Code et aux normes électriques et de sécurité locales.
NOTE: Use a wall box with a depth of at least 3.0 inches (7.6 cm). Alternatively, the included mud ring (MR 200) can be
used. For more information, see the DTP T UWP 4K D Series User Guide at www.extron.com.
a. Place the wall box against the installation surface and mark the opening guidelines.
TIP: Use a level to mark the opening.
b. Cut out the material from the marked area.
c. Secure the wall box to the wall stud with 10-penny nails or #8 or #10 screws, leaving the front edge ush with the
surface.
d. Run all required cables (see steps 3, 4, and 5) and secure them with cable clamps.
Decora Faceplate
TIP: In order to t the unit in the junction box, do not install boots on TP cables and RJ-45 connectors.
DTP T UWP 4K D • Setup Guide (Continued)
Front Panel
A
B
R
DTP OUTREMOTEOVER
DTP
SIG LINK
RS-232
CONTACT
DTP T UWP 232 D
Tx Rx
Tx Rx G
POWER
12V
A MAX
0.9
+–
G12
A/S
Rear Panel
DTP T UWP 232 D Rear Panel
F
A B
C
D
E
Connected RS-232 and
l
l
SIG LINK
DTP IN
Step 3 — Connect Inputs to the Transmitter
Front Panel
A Audio input connector — Connect an unbalanced stereo
audio source to this 3.5 mm mini stereo jack.
B HDMI input connector — Connect an HDMI cable between
this port and the output port of the digital video source.
C VGA input connector — Connect a VGA cable between this
port and the output port of the video source.
D Mini USB port — Connect a male Mini USB-B cable to this
port for SIS conguration and rmware updates.
Rear Panel
A DC power input connector — Wire and plug the included external
12 VDC power supply into either this 2-pole connector or the power input connector on the receiver (see the DTP T UWP 4K D Series User Guide at www.extron.com for wiring information).
B Over DTP connector — Connect an RS-232 device to this 3-pole,
3.5 mm captive screw connector for pass-through RS-232 control.
C Remote connector — Connect an RS-232 device, contact closure
device, or both to this 5-pole, 3.5 mm captive screw connector to control switching on the unit. Wire the connector as shown in the diagram below.
RS-232 — To control the unit through this port, connect an RS-232
device and congure it as follows: 9600 baud rate, 8 data bits, 1 stop bit, no parity.
Contact — Momentarily short pins 1 or 2 to ground (G) to select
the corresponding input.
D Grounding Screw — Connect a grounding wire from this screw to the
wall box to ground the unit.
E DTP OUT connector — Connect one end of a twisted pair cable to this
RJ-45 connector and the opposite end to a compatible receiver.
Tx/Rx
Pins
RS-232 Contact
Contact Closure Device Pins
21
G
RxTx
Pin 2 for contact closure contro Pin 1 for contact closure contro
Ground Transmit pin on connected unit Receive pin on connected unit
SIG LINK
DTP OUT
AUTO SW
AUDIO IN
HDMI IN
E
DTP T UWP 4K D
Reset
HDCP
1
CONFIG
AUDIO IN
VGA IN
+–
Tx Rx G
0.9 A MAX
Tx Rx
G12
12V
DTP
RS-232
CONTACT
SIGLINK
DTP T UWP 4K D
A DC power input connector B Over DTP connector C Remote connector D Grounding screw E DTP OUT connector F Reset button (page 3)
A C
D
POWER
A
DTP T UWP 4K 232 D
B C
DTP OUTREMOTEOVER
D E
2
ATTENTION:
Do not connect these outputs to a telecommunications or computer data network.
Ne connectez pas ces appareils à des données informatiques ou à un réseau de
télécommunications.
NOTES:
The DTP T UWP 4K 232 D model can transmit video, control, and audio (if applicable)
signals up to 230 feet (70 meters).
The DTP T UWP 4K 332 D model can transmit video, control, and audio (if applicable)
F Reset button — To perform a factory reset, use an Extron Tweeker or small screwdriver to press and hold this recessed
button for 6 seconds while the switcher is running.
signals up to 330 feet (100 meters).
Loading...