IMPORTANT:
Go to www.extron.com for the complete
user guide, installation instructions, and
specifications before connecting the
product to the power source.
DTP T UWP 4K D Series • Setup Guide
Signal Output
Cable
Cable
Clamp
Decora Faceplate
Extron
DTP HWP 232 D
Screws or
Nails
Wall opening is
flush with edge of box.
Wall Stud
AUTO SW
CONFIG
HDCP
1
IR OUT
HDMI IN
AUDIO IN
S
G
AUDIO IN
This setup guide provides instructions for an experienced installer to set up and operate the Extron DTP T UWP 4K D series of
Twisted Pair (TP) wallplate extenders.
1 2 3 4 5 6 7 8
CONFIG
E
1
3
CONFIGURABLE
100-240V ~ -- A MAX
2
4
50/60 Hz
IN1608
INPUTS
INPUTS
5
HDMI
6
SIGNAL
HDCP
IN1608 SA
OVER DTP
RS-232 IR
C
TxRx TxRxG
7
8
SIG LINK
SIG LINK
SIG LINK
OVER DTP
OVER DTP
HDMI
RS-232 IR
RS-232 IR
DTP OUT
TxRx TxRxG
DTP IN
DTP IN
TxRx TxRxG
Installation
Step 1 — Disconnect Power
Disconnect all equipment power sources.
Step 2 — Prepare the Mounting Surface
AUTO SW
AUDIO IN
AUDIO IN
HDCP
1
VGA IN
HDMI IN
CONFIG
Extron
DTP T UWP 4K 232 D
Transmitter
XTP DTP 24 Cable
230'
INPUTS
1
2 3 4 5 6 7 8 A B C
OUTPUTS
A
HDMI
B
OUTPUTS
MENU
VOLUME
ENTER
IN1608
SCALING PRESENTATION SWITCHER
AMPLIFIED OUTPUT
2x25W(8Ω)/2x50W(4Ω)
L3R
AUDIO INPUTS
OUTPUTS
LL1R R
L5R
12
CLASS 2 WIRING
REMOTE
LAN
+48V
MIC/LINE
VARIABLE
RESET
L2
L4
R
R
RS-232
L6
LR
R
2
+48V
TxRx
DTP HDMI 4K 230 Rx
IPCP 505
COM
SWITCHED
12VDC
LIMIT
2
R
G
314
TXRXTX
OVER
12345678
IPCP 505
SIG LINK
POWER
12V
0.7A MAX
DTP IN
Wall opening is
flush with edge of box.
RTS
IR/S
CTS
4
RX
5162738
Ethernet
OUTPUTS
Wall Stud
Screws or
Nails
RELAY
5162314
LR
FLEX
100
eBUS
I/O
ACT LIMIT
2
4
OVER
738
Network
LINK
IR
ACT
TLP 1000T
AUDIO
HDMI
ATTENTION:
• Installation and service must be performed by
authorized personnel.
• L’installation et l’entretien doivent être effectués
par le personnel autorisé uniquement.
• The unit must be installed in accordance with the
Cable
Clamp
AUDIO IN
AUTO SW
HDCP
1
VGA IN
AUDIO IN
CONFIG
HDMI IN
National Electrical Code and with local electrical
and safety codes.
Signal Output
Cable
Extron
DTP UWP 4K 232 D
• L’unité doit être installée conformément au
National Electric Code et aux normes électriques
et de sécurité locales.
NOTE: Use a wall box with a depth of at least 3.0 inches (7.6 cm). Alternatively, the included mud ring (MR 200) can be
used. For more information, see the DTP T UWP 4K D Series User Guide at www.extron.com.
a. Place the wall box against the installation surface and mark the opening guidelines.
TIP: Use a level to mark the opening.
b. Cut out the material from the marked area.
c. Secure the wall box to the wall stud with 10-penny nails or #8 or #10 screws, leaving the front edge ush with the
surface.
d. Run all required cables (see steps 3, 4, and 5) and secure them with cable clamps.
Decora Faceplate
TIP: In order to t the unit in the junction box, do not install boots on TP cables and RJ-45 connectors.

DTP T UWP 4K D • Setup Guide (Continued)
R
DTP OUTREMOTEOVER
DTP
SIG LINK
RS-232
CONTACT
DTP T UWP 232 D
Tx Rx
Tx Rx G
POWER
12V
A MAX
0.9
+–
G12
A/S
Rear Panel
DTP T UWP 232 D
Rear Panel
Step 3 — Connect Inputs to the Transmitter
Front Panel
A Audio input connector — Connect an unbalanced stereo
audio source to this 3.5 mm mini stereo jack.
B HDMI input connector — Connect an HDMI cable between
this port and the output port of the digital video source.
C VGA input connector — Connect a VGA cable between this
port and the output port of the video source.
D Mini USB port — Connect a male Mini USB-B cable to this
port for SIS conguration and rmware updates.
Rear Panel
A DC power input connector — Wire and plug the included external
12 VDC power supply into either this 2-pole connector or the power
input connector on the receiver (see the DTP T UWP 4K D Series User
Guide at www.extron.com for wiring information).
B Over DTP connector — Connect an RS-232 device to this 3-pole,
3.5 mm captive screw connector for pass-through RS-232 control.
C Remote connector — Connect an RS-232 device, contact closure
device, or both to this 5-pole, 3.5 mm captive screw connector to
control switching on the unit. Wire the connector as shown in the
diagram below.
• RS-232 — To control the unit through this port, connect an RS-232
device and congure it as follows: 9600 baud rate, 8 data bits,
1 stop bit, no parity.
• Contact — Momentarily short pins 1 or 2 to ground (G) to select
the corresponding input.
D Grounding Screw — Connect a grounding wire from this screw to the
wall box to ground the unit.
E DTP OUT connector — Connect one end of a twisted pair cable to this
RJ-45 connector and the opposite end to a compatible receiver.
Tx/Rx
Pins
RS-232 Contact
Contact Closure Device Pins
21
G
RxTx
Pin 2 for contact closure contro
Pin 1 for contact closure contro
Ground
Transmit pin on connected unit
Receive pin on connected unit
SIG LINK
DTP OUT
AUTO SW
AUDIO IN
HDMI IN
E
DTP T UWP 4K D
Reset
HDCP
1
CONFIG
AUDIO IN
VGA IN
+–
Tx Rx G
0.9 A MAX
Tx Rx
G12
12V
DTP
RS-232
CONTACT
SIGLINK
DTP T UWP 4K D
A DC power input connector
B Over DTP connector
C Remote connector
D Grounding screw
E DTP OUT connector
F Reset button (page 3)
A
C
D
POWER
A
DTP T UWP 4K 232 D
B
C
DTP OUTREMOTEOVER
D
E
2
ATTENTION:
• Do not connect these outputs to a telecommunications or computer data network.
• Ne connectez pas ces appareils à des données informatiques ou à un réseau de
télécommunications.
NOTES:
• The DTP T UWP 4K 232 D model can transmit video, control, and audio (if applicable)
signals up to 230 feet (70 meters).
• The DTP T UWP 4K 332 D model can transmit video, control, and audio (if applicable)
F Reset button — To perform a factory reset, use an Extron Tweeker or small screwdriver to press and hold this recessed
button for 6 seconds while the switcher is running.
signals up to 330 feet (100 meters).