![](/html/ba/ba69/ba696d997851af7139310f06c46efa18b21535898743a349c4235f11b2b2b476/bg1.png)
DTP2T204 • Setup Guide
IMPORTANT:
Go to www.extron.com for the complete
user guide, installation instructions, and
specifications before connecting the
product to the power source.
The Extron DTP2 T 204 is an HDCP-compliant, four
input HDMI switcher with a DTP2 output that switches
and extends digital embedded audio, bidirectional
RS-232, IR, and remote power.
It supports video resolutions up to 4K @ 60 Hz and
1080p @ 120 Hz, using shielded twisted pair cabling as
a transmission medium, and extends HDMI video signals
DTP2 R 211
Receiver
SIG LINK
OVER DTP2
DTP2 IN
OUTPUTS
AUDIO
L
R
ON/OFF/MUTE Control
ON OFFMUTE
Extron
CCR 30
Contact Closure Remote
with Three LED Switches
RS-232
HDMI
POWER
12V
--A MAX
RS-232 IR
TxRx TxRxG
MODEL 80
up to 330 feet (100 meters).
CATx Cable
The switcher features four HDMI inputs and a
DTP2/HDBT output, data rates up to 18 Gbps, HDR,
12 bit Deep Color, 3D, Lip Sync, HD lossless audio
formats, and SIS to CEC control. EDID Minder®
maintains EDID communication with connected devices
and ensures that the HDMI sources power up properly
and maintain correct video output.
Control is available via front panel buttons, USB, Extron
Product Control Software (PCS), Ethernet, RS-232,
Extron
DTP2 T 204
Transmitter
Extron
HDMI SM
Show Me Cables
up to 330' (100 m)
DTP2 T 204
POWER
1234
12V
2.0AMAX
SHARE
SHARE
OVER TP
HDBT
SEND POWER
RS-232 IR
56
TxRx GTxRx
OFF
DTP
C
C
TG+V
CONT
12 34
C
C
TG+V
Ethernet
REMOTE
RS-232
Tx
Rx
G
TTCCT+VT
LAN
POWER
12V
0.3A MAX
Tx Rx RTSCTS
LAN
COM 1 COM 2 COM 3
G
Tx Rx RTSCTS
G
Tx Rx RTSCTS
IPL PRO S3
G
LAN / PoE
INPUTS
SHARE
LINKSIG
OUT
HDMI
contact closure, and auto-input switching for integration
with any control system. Front panel LED indicators provide immediate visual conrmation of HDCP authentication and signal
presence for each input and output. Remote power for the end unit is available via the DTP output.
This guide provides instructions for an experienced installer to set up and operate this switcher. For full installation,
conguration, and operation details, see the DTPT204 User Guide, available at www.extron.com.
Rear Panel Features and Connections
FLAT PANEL
Flat Panel Display
Extron
IPL Pro S3
IP Link Pro
Control Processor
Ethernet
LAN
DTP2 T 204
POWER
1 2 3 4
12V
2.2A MAX
Figure 1.
Installation Steps
1. Turn off and disconnect all of the equipment from the power source.
2. Mount the switcher on a rack shelf or furniture (optional).
3. Connect HDMI input sources to one or more of the DTP2T 204 inputs (see figure1,
present at each input and HotPlugDetect (HPD) is actively controlled on each input.
NOTES:
• The default (Extron) EDID is 1080p @ 60 Hz (see the DTP2T204 User Guide for the
4. Connect the input of a DTP2 or HDBaseT compatible device to the DTP/HDBT OUT
• LockIt® cable lacing brackets are provided to secure the HDMI cables to the rear panel
RJ-45 connector (C). See the image at right to wire the connector.
F
56
C
C
TG+V
REMOTE
RS-232
Tx
Rx
G
TTCCT +VT
TG+V
A
B
C
D
LAN
E
INPUTS
OUT
I
OVER TP
HDBT
Tx Rx GTxRx
DTP
LINKSIG
RS-232 IR
CONT
12 34
C
SEND POWER
OFF
C
F
DTP2T204Rear Panel
G
H
I
B
EDID table).
connectors to reduce stress on the HDMI connectors and prevent signal loss due to
loose cable connections (see the LockIt Lacing Brackets on page4).
Power input connector
HDMI input connectors
DTP/HDBT Output RJ-45 port
TP mode switch
Over TP RS-232 and IR port
Contact input and tally output
ports with +V connectors
Remote RS-232 port
LAN RJ-45 port
Remote power toggle switch
). The default (Extron) EDID is
12345678
TP Wires
TIA/EIA T
Pin
Wire color
White-orange
1
Orange
2
3
White-green
4
Blue
White-blue
5
6
Green
7
White-brown
8
Brown
568 B
1
![](/html/ba/ba69/ba696d997851af7139310f06c46efa18b21535898743a349c4235f11b2b2b476/bg2.png)
Connected RS-232
and IR Device Pins
DTP2 T 204 • Setup Guide (Continued)
5. Set the TP mode switch (
• If the receiving device is an Extron DTP device, set the switch to DTP.
• If the receiving device is HDBaseT enabled, set the switch to HDBT.
) to HDBT (up) or DTP (down) as follows:
D
When the output is congured for DTP mode, remote power is available. When the output is congured for HDBT mode,
remote power is disabled and the switcher and receiver each require its own 12 VDC power supply.
ATTENTION:
• Position this switch before connecting the appropriate device to the TP connector. Failure to comply can damage
the endpoint.
• Positionnez le sélecteur avant de connecter l’appareil approprié au connecteur TP. Ne pas respecter cette
procédure pourrait endommager le point de connexion.
• Do not connect these devices to a computer data or telecommunications network.
• Ne connectez pas cet appareil à un réseau de télécommunications ou de données informatiques.
6. Connect Over TP RS-232 and IR control. Connect a serial RS-232 signal,
a modulated IR signal, or both into this 3.5 mm, 5-pole captive screw connector
(see figure1,E, on the previous page) for bidirectional RS-232 and IR
communication (see the image on the right to wire the RS-232 and IR connector).
7. Connect control devices. Connect your computer to one of the following
DTP2T204 communication ports to configure and control
the switcher via SIS commands or PCS:
• RS-232 port — Connect the unterminated transmit,
receive, and ground wires of the RS-232 cable to the
RS-232
Tx Rx G
DTP2 T 204 Switcher
Rear Panel
Remote Port
three pins on the provided 3-pole captive screw plug,
as shown in the image at right. Connect the plug to the
rear panel Remote RS-232 connector (G), and the
NOTE: If you use cable that has a drain
wire, tie the drain wire to ground at both ends.
other end of the cable to your computer serial port.
Protocol for the RS-232 port is 9600 baud, 8 data
bits, 1 stop bit, and no parity.
• Config port — Connect a USB mini-B cable to the
front panel USB connector (see figure2,B, on the
next page) for USB control.
• LAN port — To control the DTP2 T 204 through Ethernet, connect a LAN to the RJ-45 LAN connector (see figure 1,
). The default IP address of the scaler is 192.168.254.254, the default subnet mask is 255.255.255.0, and the default
H
gateway address is 0.0.0.0. (See the diagram in step 4 on the previous page to wire this connector.)
8. (Optional) Connect contact closure and tally indicator devices. The Contact/Tally
section of the rear panel (B, on the previous page) contains four captive screw
connectors, each containing two pairs of pins labeled C and T (see 1, 3, 5, and 6
in the image at right). Each C-T pin pair is labeled with its contact input number (1
through 6), and each individual pin is labeled with its function:
• C = Contact closure input
• T = Tally output
• G = Ground (for example, 4)
• +V = +V connector for the tally output power wire (for example, 2)
To enable input switching via contact closure, connect a contact closure device to a
contact-tally port as follows:
a. Connect a push-button contact closure device to a C pin of one of the contact-tally connectors.
b. Connect the ground wire of the contact device to one of the G pins.
c. If desired, to identify the currently selected input when the front panel LEDs are not visible, connect an indicator device,
such as an LED, to tally output pin (T) to the right of the connected C pin. When the input you are using is selected, the
corresponding tally out pin shorts to ground, which activates the connected indicator.
d. Insert the LED+ wire of the indicator device into a +V connector.
e. Press the button on the contact closure device to switch the connected input to the output.
2
Pins
Ground (G)
Receive (Rx)
Transmit (Tx)
Tx Rx Tx RxG
Transmit (Tx)
Receive (Rx)
POWER
SEND
111
22
OFF
333
CONT
12 34
C+VTCTCTCT
Transmit pin
Receive pin
Ground
Transmit pin
Receive pin
Computer or
Control Syste
RS-232 Port
555 666
5
G
REMOTE
RS-232
G
RxTx
444
6
VTGC+VT