While reasonable efforts have been made to ensure that the
information in this document is complete and accurate at the time of
printing, Extreme Networks, Inc. assumes no liability for any errors.
Extreme Networks, Inc. reserves the right to make changes and
corrections to the information in this document without the obligation
to notify any person or organization of such changes.
Documentation disclaimer
“Documentation” means information published in varying mediums
which may include product information, operating instructions and
performance specifications that are generally made available to users
of products. Documentation does not include marketing materials.
Extreme Networks shall not be responsible for any modifications,
additions, or deletions to the original published version of
Documentation unless such modifications, additions, or deletions
were performed by or on the express behalf of Extreme Networks.
End User agrees to indemnify and hold harmless Extreme Networks,
Extreme Networks’ agents, servants and employees against all
claims, lawsuits, demands and judgments arising out of, or in
connection with, subsequent modifications, additions or deletions to
this documentation, to the extent made by End User.
Link disclaimer
Extreme Networks is not responsible for the contents or reliability of
any linked websites referenced within this site or Documentation
provided by Extreme Networks. Extreme Networks is not responsible
for the accuracy of any information, statement or content provided on
these sites and does not necessarily endorse the products, services,
or information described or offered within them. Extreme Networks
does not guarantee that these links will work all the time and has no
control over the availability of the linked pages.
Warranty
Extreme Networks provides a limited warranty on Extreme Networks
hardware and software. Refer to your sales agreement to establish
the terms of the limited warranty. In addition, Extreme Networks’
standard warranty language, as well as information regarding support
for this product while under warranty is available to Extreme
Networks customers and other parties through the Extreme Networks
Support website:
http://www.extremenetworks.com/support under the
link ““Policies” or such successor site as designated by Extreme
Networks. Please note that if You acquired the product(s) from an
authorized Extreme Networks Channel Partner outside of the United
States and Canada, the warranty is provided to You by said Extreme
Networks Channel Partner and not by Extreme Networks.
“Hosted Service” means an Extreme Networks hosted service
subscription that You acquire from either Extreme Networks or an
authorized Extreme Networks Channel Partner (as applicable) and
which is described further in Hosted SAS or other service description
documentation regarding the applicable hosted service. If You
purchase a Hosted Service subscription, the foregoing limited
warranty may not apply but You may be entitled to support services
in connection with the Hosted Service as described further in your
service description documents for the applicable Hosted Service.
Contact Extreme Networks or Extreme Networks Channel Partner (as
applicable) for more information.
Hosted Service
THE FOLLOWING APPLIES ONLY IF YOU PURCHASE AN
EXTREME NETWORKS HOSTED SERVICE SUBSCRIPTION
FROM EXTREME NETWORKS OR AN EXTREME NETWORKS
CHANNEL PARTNER (AS APPLICABLE), THE TERMS OF USE
FOR HOSTED SERVICES ARE AVAILABLE ON THE EXTREME
NETWORKS WEBSITE,
https://extremeportal.force.com OR SUCH
SUCCESSOR SITE AS DESIGNATED BY EXTREME NETWORKS,
AND ARE APPLICABLE TO ANYONE WHO ACCESSES OR USES
THE HOSTED SERVICE. BY ACCESSING OR USING THE
HOSTED SERVICE, OR AUTHORIZING OTHERS TO DO SO, YOU,
ON BEHALF OF YOURSELF AND THE ENTITY FOR WHOM YOU
ARE DOING SO (HEREINAFTER REFERRED TO
INTERCHANGEABLY AS “YOU” AND “END USER”), AGREE TO
THE TERMS OF USE. IF YOU ARE ACCEPTING THE TERMS OF
USE ON BEHALF A COMPANY OR OTHER LEGAL ENTITY, YOU
REPRESENT THAT YOU HAVE THE AUTHORITY TO BIND SUCH
ENTITY TO THESE TERMS OF USE. IF YOU DO NOT HAVE SUCH
AUTHORITY, OR IF YOU DO NOT WISH TO ACCEPT THESE
TERMS OF USE, YOU MUST NOT ACCESS OR USE THE
HOSTED SERVICE OR AUTHORIZE ANYONE TO ACCESS OR
USE THE HOSTED SERVICE.
Licenses
THE SOFTWARE LICENSE TERMS AVAILABLE ON THE
EXTREME NETWORKS WEBSITE,
https://extremeportal.force.com
OR SUCH SUCCESSOR SITE AS DESIGNATED BY EXTREME
NETWORKS, ARE APPLICABLE TO ANYONE WHO
DOWNLOADS, USES AND/OR INSTALLS EXTREME NETWORKS
SOFTWARE, PURCHASED FROM EXTREME NETWORKS, INC.,
ANY EXTREME NETWORKS AFFILIATE, OR AN EXTREME
NETWORKS CHANNEL PARTNER (AS APPLICABLE) UNDER A
COMMERCIAL AGREEMENT WITH EXTREME NETWORKS OR
AN EXTREME NETWORKS CHANNEL PARTNER. UNLESS
OTHERWISE AGREED TO BY EXTREME NETWORKS IN
WRITING, EXTREME NETWORKS DOES NOT EXTEND THIS
LICENSE IF THE SOFTWARE WAS OBTAINED FROM ANYONE
OTHER THAN EXTREME NETWORKS, AN EXTREME
NETWORKS AFFILIATE OR AN EXTREME NETWORKS CHANNEL
PARTNER; EXTREME NETWORKS RESERVES THE RIGHT TO
TAKE LEGAL ACTION AGAINST YOU AND ANYONE ELSE USING
OR SELLING THE SOFTWARE WITHOUT A LICENSE. BY
INSTALLING, DOWNLOADING OR USING THE SOFTWARE, OR
AUTHORIZING OTHERS TO DO SO, YOU, ON BEHALF OF
YOURSELF AND THE ENTITY FOR WHOM YOU ARE
INSTALLING, DOWNLOADING OR USING THE SOFTWARE
(HEREINAFTER REFERRED TO INTERCHANGEABLY AS “YOU”
AND “END USER”), AGREE TO THESE TERMS AND CONDITIONS
AND CREATE A BINDING CONTRACT BETWEEN YOU AND
EXTREME NETWORKS, INC. OR THE APPLICABLE EXTREME
NETWORKS AFFILIATE (“EXTREME NETWORKS”).
Extreme Networks grants You a license within the scope of the
license types described below. Where the order documentation does
not expressly identify a license type, the applicable license will be a
Designated System License as set forth below in the Designated
System(s) License (DS) section as applicable. The applicable
number of licenses and units of capacity for which the license is
granted will be one (1), unless a different number of licenses or units
of capacity is specified in the documentation or other materials
available to You. “Software” means computer programs in object
code, provided by Extreme Networks or an Extreme Networks
Channel Partner, whether as stand-alone products, pre-installed on
hardware products, and any upgrades, updates, patches, bug fixes,
or modified versions thereto. “Designated Processor” means a single
stand-alone computing device. “Server” means a set of Designated
Processors that hosts (physically or virtually) a software application
to be accessed by multiple users. “Instance” means a single copy of
the Software executing at a particular time: (i) on one physical
machine; or (ii) on one deployed software virtual machine (“VM”) or
similar deployment.
License type(s)
Designated System(s) License (DS). End User may install and use
each copy or an Instance of the Software only: 1) on a number of
Designated Processors up to the number indicated in the order; or 2)
up to the number of Instances of the Software as indicated in the
order, Documentation, or as authorized by Extreme Networks in
writing. Extreme Networks may require the Designated Processor(s)
to be identified in the order by type, serial number, feature key,
Instance, location or other specific designation, or to be provided by
End User to Extreme Networks through electronic means established
by Extreme Networks specifically for this purpose.
Copyright
Except where expressly stated otherwise, no use should be made of
materials on this site, the Documentation, Software, Hosted Service,
or hardware provided by Extreme Networks. All content on this site,
the documentation, Hosted Service, and the product provided by
Extreme Networks including the selection, arrangement and design
of the content is owned either by Extreme Networks or its licensors
and is protected by copyright and other intellectual property laws
including the sui generis rights relating to the protection of databases.
You may not modify, copy, reproduce, republish, upload, post,
transmit or distribute in any way any content, in whole or in part,
including any code and software unless expressly authorized by
Extreme Networks. Unauthorized reproduction, transmission,
dissemination, storage, and or use without the express written
consent of Extreme Networks can be a criminal, as well as a civil
offense under the applicable law.
Virtualization
The following applies if the product is deployed on a virtual machine.
Each product has its own ordering code and license types. Note,
unless otherwise stated, that each Instance of a product must be
separately licensed and ordered. For example, if the end user
customer or Extreme Networks Channel Partner would like to install
two Instances of the same type of products, then two products of that
type must be ordered.
Third Party Components
“Third Party Components” mean certain software programs or
portions thereof included in the Software or Hosted Service may
contain software (including open source software) distributed under
third party agreements (“Third Party Components”), which contain
terms regarding the rights to use certain portions of the Software
(“Third Party Terms”). As required, information regarding distributed
Linux OS source code (for those products that have distributed Linux
OS source code) and identifying the copyright holders of the Third
Party Components and the Third Party Terms that apply is available
in the products, Documentation or on Extreme Networks’ website
at:http://www.extremenetworks.com/support/policies/software-
licensing or such successor site as designated by Extreme Networks.
The open source software license terms provided as Third Party
Terms are consistent with the license rights granted in these Software
License Terms, and may contain additional rights benefiting You,
such as modification and distribution of the open source software.
The Third Party Terms shall take precedence over these Software
License Terms, solely with respect to the applicable Third Party
Components to the extent that these Software License Terms impose
greater restrictions on You than the applicable Third Party Terms.
The following applies only if the H.264 (AVC) codec is distributed with
the product. THIS PRODUCT IS LICENSED UNDER THE AVC
PATENT PORTFOLIO LICENSE FOR THE PERSONAL USE OF A
CONSUMER OR OTHER USES IN WHICH IT DOES NOT RECEIVE
REMUNERATION TO (i) ENCODE VIDEO IN COMPLIANCE WITH
THE AVC STANDARD (“AVC VIDEO”) AND/OR (ii) DECODE AVC
VIDEO THAT WAS ENCODED BY A CONSUMER ENGAGED IN A
PERSONAL ACTIVITY AND/OR WAS OBTAINED FROM A VIDEO
PROVIDER LICENSED TO PROVIDE AVC VIDEO. NO LICENSE IS
GRANTED OR SHALL BE IMPLIED FOR ANY OTHER USE.
ADDITIONAL INFORMATION MAY BE OBTAINED FROM MPEG LA,
L.L.C. SEE
Service Provider
THE FOLLOWING APPLIES TO EXTREME NETWORKS CHANNEL
PARTNER’S HOSTING OF EXTREME NETWORKS PRODUCTS
OR SERVICES. THE PRODUCT OR HOSTED SERVICE MAY USE
THIRD PARTY COMPONENTS SUBJECT TO THIRD PARTY
TERMS AND REQUIRE A SERVICE PROVIDER TO BE
INDEPENDENTLY LICENSED DIRECTLY FROM THE THIRD
PARTY SUPPLIER. AN EXTREME NETWORKS CHANNEL
PARTNER’S HOSTING OF EXTREME NETWORKS PRODUCTS
MUST BE AUTHORIZED IN WRITING BY EXTREME NETWORKS
AND IF THOSE HOSTED PRODUCTS USE OR EMBED CERTAIN
THIRD PARTY SOFTWARE, INCLUDING BUT NOT LIMITED TO
MICROSOFT SOFTWARE OR CODECS, THE EXTREME
NETWORKS CHANNEL PARTNER IS REQUIRED TO
INDEPENDENTLY OBTAIN ANY APPLICABLE LICENSE
AGREEMENTS, AT THE EXTREME NETWORKS CHANNEL
PARTNER’S EXPENSE, DIRECTLY FROM THE APPLICABLE
THIRD PARTY SUPPLIER.
WITH RESPECT TO CODECS, IF THE EXTREME NETWORKS
CHANNEL PARTNER IS HOSTING ANY PRODUCTS THAT USE
OR EMBED THE G.729 CODEC, H.264 CODEC, OR H.265
CODEC, THE EXTREME NETWORKS CHANNEL PARTNER
ACKNOWLEDGES AND AGREES THE EXTREME NETWORKS
CHANNEL PARTNER IS RESPONSIBLE FOR ANY AND ALL
RELATED FEES AND/OR ROYALTIES. THE G.729 CODEC IS
LICENSED BY SIPRO LAB TELECOM INC. SEE
WWW.SIPRO.COM/CONTACT.HTML. THE H.264 (AVC) CODEC IS
LICENSED UNDER THE AVC PATENT PORTFOLIO LICENSE FOR
HTTP://WWW.MPEGLA.COM.
THE PERSONAL USE OF A CONSUMER OR OTHER USES IN
WHICH IT DOES NOT RECEIVE REMUNERATION TO: (I) ENCODE
VIDEO IN COMPLIANCE WITH THE AVC STANDARD (“AVC
VIDEO”) AND/OR (II) DECODE AVC VIDEO THAT WAS ENCODED
BY A CONSUMER ENGAGED IN A PERSONAL ACTIVITY AND/OR
WAS OBTAINED FROM A VIDEO PROVIDER LICENSED TO
PROVIDE AVC VIDEO. NO LICENSE IS GRANTED OR SHALL BE
IMPLIED FOR ANY OTHER USE. ADDITIONAL INFORMATION
FOR H.264 (AVC) AND H.265 (HEVC) CODECS MAY BE
OBTAINED FROM MPEG LA, L.L.C. SEE
WWW.MPEGLA.COM.
Compliance with Laws
You acknowledge and agree that it is Your responsibility for
complying with any applicable laws and regulations, including, but not
limited to laws and regulations related to call recording, data privacy,
intellectual property, trade secret, fraud, and music performance
rights, in the country or territory where the Extreme Networks product
is used.
Preventing Toll Fraud
“Toll Fraud” is the unauthorized use of your telecommunications
system by an unauthorized party (for example, a person who is not a
corporate employee, agent, subcontractor, or is not working on your
company's behalf). Be aware that there can be a risk of Toll Fraud
associated with your system and that, if Toll Fraud occurs, it can
result in substantial additional charges for your telecommunications
services.
Security Vulnerabilities
Information about Extreme Networks’ security support policies can be
found in the Global Technical Assistance Center Knowledgebase at
https://gtacknowledge.extremenetworks.com/.
Downloading Documentation
For the most current versions of Documentation, see the Extreme
Networks Support website:
documentation.extremenetworks.com, or such successor site as
designated by Extreme Networks.
Contact Extreme Networks Support
See the Extreme Networks Support website:
www.extremenetworks.com/support for product or Hosted Service
notices and articles, or to report a problem with your Extreme
Networks product or Hosted Service. For a list of support telephone
numbers and contact addresses, go to the Extreme Networks
Support website:
(or such successor site as designated by Extreme Networks), scroll
to the bottom of the page, and select Contact Extreme Networks
Support.
Contact Avaya Support
See the Avaya Support website:
product or Hosted Service notices and articles, or to report a problem
with your Avaya product or Hosted Service. For a list of support
telephone numbers and contact addresses, go to the Avaya Support
website:
designated by Avaya), scroll to the bottom of the page, and select
Contact Avaya Support.
Trademarks
The trademarks, logos and service marks (“Marks”) displayed in this
site, the Documentation, Hosted Service(s), and product(s) provided
by Extreme Networks are the registered or unregistered Marks of
Extreme Networks, Inc., its affiliates, its licensors, its suppliers, or
other third parties. Users are not permitted to use such Marks without
prior written consent from Extreme Networks or such third party
which may own the Mark. Nothing contained in this site, the
Documentation, Hosted Service(s) and product(s) should be
construed as granting, by implication, estoppel, or otherwise, any
license or right in and to the Marks without the express written
permission of Extreme Networks or the applicable third party.
Extreme Networks is a registered trademark of Extreme Networks,
Inc.
All non-Extreme Networks trademarks are the property of their
respective owners. Linux® is the registered trademark of Linus
Torvalds in the U.S. and other countries.
http://www.extremenetworks.com/support/contact/
https://support.avaya.com (or such successor site as
http://
https://support.avaya.com for
HTTP://
http://
For additional information on Extreme Networks trademarks, please
see: http://www.extremenetworks.com/company/legal/
Pinging an IP device........................................................................................................ 47
Displaying the agent and diagnostic software load............................................................. 48
Displaying RMON Alarms using CLI.................................................................................. 49
December 20176
Chapter 1:Preface
Purpose
This document provides basic instructions to perform the basic configuration of the Extreme
Networks ERS 3600 Series chassis and software.
Training
Ongoing product training is available. For more information or to register, you can access the Web
site at
www.extremenetworks.com/education/.
Providing Feedback to Us
We are always striving to improve our documentation and help you work better, so we want to hear
from you! We welcome all feedback but especially want to know about:
• Content errors or confusing or conflicting information.
• Ideas for improvements to our documentation so you can find the information you need faster.
• Broken links or usability issues.
If you would like to provide feedback to the Extreme Networks Information Development team about
this document, please contact us using our short
directly at
internalinfodev@extremenetworks.com
online feedback form. You can also email us
Getting Help
Product purchased from Extreme Networks
If you purchased your product from Extreme Networks, use the following support contact information
to get help.
December 20177
Preface
If you require assistance, contact Extreme Networks using one of the following methods:
• GTAC (Global Technical Assistance Center) for Immediate Support
- Phone: 1-800-998-2408 (toll-free in U.S. and Canada) or +1 408-579-2826. For the support
phone number in your country, visit:
www.extremenetworks.com/support/contact
- Email:
or model number in the subject line.
GTAC Knowledge – Get on-demand and tested resolutions from the GTAC Knowledgebase, or
•
create a help case if you need more guidance.
The Hub – A forum for Extreme customers to connect with one another, get questions
•
answered, share ideas and feedback, and get problems solved. This community is monitored
by Extreme Networks employees, but is not intended to replace specific guidance from GTAC.
Support Portal – Manage cases, downloads, service contracts, product licensing, and training
•
and certifications.
Before contacting Extreme Networks for technical support, have the following information ready:
• Your Extreme Networks service contract number and/or serial numbers for all involved Extreme
Networks products
• A description of the failure
• A description of any action(s) already taken to resolve the problem
• A description of your network environment (such as layout, cable type, other relevant
environmental information)
• Network load at the time of trouble (if known)
• The device history (for example, if you have returned the device before, or if this is a recurring
problem)
support@extremenetworks.com. To expedite your message, enter the product name
• Any related RMA (Return Material Authorization) numbers
Product purchased from Avaya
If you purchased your product from Avaya, use the following support contact information to get help.
Go to the Avaya Support website at
documentation, product notices, and knowledge articles. You can also search for release notes,
downloads, and resolutions to issues. Use the online service request system to create a service
request. Chat with live agents to get answers to questions, or request an agent to connect you to a
support team if an issue requires additional expertise.
Some software files have been licensed under certain open source licenses. More information is
available at: www.extremenetworks.com/support/policies/software-licensing.
Subscribing to service notifications
Subscribe to receive an email notification for product and software release announcements,
Vulnerability Notices, and Service Notifications.
About this task
You can modify your product selections at any time.
Procedure
1. In an Internet browser, go to http://www.extremenetworks.com/support/service-notification-
form/ .
2. Type your first and last name.
3. Type the name of your company.
4. Type your email address.
5. Type your job title.
6. Select the industry in which your company operates.
7. Confirm your geographic information is correct.
8. Select the products for which you would like to receive notifications.
9. Click Submit.
December 20179
Chapter 2:New in this document
There are no new feature changes in this document.
December 201710
Chapter 3:Fundamentals
This document includes the minimum but essential configuration steps to:
• provide a default, starting point configuration
• establish a management interface
• establish basic security on the node
The shipment includes the following:
• An installation kit
• A foldout poster (Quick Install Guide for Ethernet Routing Switch 3600 Series)
For more information about hardware specifications and installation procedures, see InstallingEthernet Routing Switch 3600 Series.
For more information about how to configure security, see Configuring Security on Ethernet RoutingSwitch 3600 Series.
System connection
Use the console cable to connect the terminal to the switch console port. The console cable and
connector must match the console port on the switch (DB-9 or RJ-45, depending on your model).
The following are the default communication protocol settings for the console port:
• 9600 baud
• 8 data bits
• 1 stop bit
• No parity
• No flow control
• VT100 or VT100/ANSI Terminal Protocol
To use the console port, you need the following equipment:
• A terminal or TeleTypewriter (TTY)-compatible terminal, or a portable computer with a serial
port and terminal-emulation software.
December 201711
Fundamentals
• An Underwriters Laboratories (UL)-listed straight-through or null modem RS-232 cable with a
female DB-9 connector for the console port on the switch. The other end of the cable must use
a connector appropriate to the serial port on your computer or terminal.
You must shield the cable that connects to the console port to comply with emissions regulations
and requirement
System logon
After the platform boot sequence is complete, a logon prompt displays.
The following table shows the default values for logon and password for console and Telnet
sessions.
configuration and status
information. Is equivalent
to Simple Network
Management Protocol
(SNMP) read-only
community access.
Read/writeView and change
configuration and status
information across the
switch. You can change
security and password
settings. This access
level is equivalent to
SNMP read/write
community access.
ROuser
RWsecure
Password encryption
The local passwords for the switch are stored in the configuration file, encrypted with an Extreme
Networks proprietary algorithm.
Important:
For security reasons, it is recommended that you configure the passwords to values other than
the factory defaults.
For more information about configuring passwords, see Configuring Security on Ethernet RoutingSwitch 3600 Series.
December 201712
Quick Start
You can use the install command in Command Line Interface (CLI) or the Quick Start menu in
Enterprise Device Manager (EDM) to configure the following:
• quick start VLAN
• in-band IP address and subnet mask
• default gateway
• DHCP server configuration
• management subnet mask, management IP address and management default gateway
• read-only and read-write community strings
• IPv6 in-band address and IPv6 default gateway
• management IPV6 address and management IPV6 default gateway
Quick Start
Password complexity
Password complexity feature enforces complexity password rules. The rules are different when the
switch is upgraded from an unsupported to a supported release for the first time. The following rules
can be configured and applied when you enable this feature:
• Minimum password length and valid characters
• Number of passwords retained in password history
• Check for sequential and repeated characters in password
For more information, see Configuring Security on Ethernet Routing Switch 3600 Series.
Password aging and lockout policy
Passwords expire after a specified aging period. The values for aging can be configured. The
default values are different when the switch is upgraded from an unsupported to a supported
release for the first time.
The management passwords can be configured to comply with company security policies. The
following rules can be configured and applied when you enable this feature:
• Number of days before password expiration
• Failed login attempts
For more information, see Configuring Security on Ethernet Routing Switch 3600 Series.
December 201713
Fundamentals
Enterprise Device Manager
Enterprise Device Manager (EDM) is an embedded graphical user interface (GUI) that you can use
to manage and monitor the platform through a standard web browser. EDM is embedded in the
switch software, and the switch operates as a web server, so you do not require additional client
software. For more information about EDM, Using CLI and EDM on Ethernet Routing Switch 3600Series.
Enterprise Device Manager access
To access EDM, open http://<deviceip>/login.html or https://<deviceip>/
login.html from either Microsoft Internet Explorer (minimum version 8.x), or Mozilla Firefox
(minimum version 3.x).
Important:
You must enable the web server from CLI to enable HTTP access to EDM. If you want HTTP
access to the device, you must also disable the web server secure-only option. The web server
secure-only option is enabled by default and allows HTTPS access to the device. Take the
appropriate security precautions within the network if you use HTTP.
If you experience issues while connecting to EDM, check the proxy settings. Proxy settings can
affect EDM connectivity to the switch. Clear the browser cache, and do not use a proxy when
connecting to the device.
Default user name and password
To log on the switch for the first time when password security is enabled, use the default password.
For the standard software image, the default password for RO is user and secure for RW. For the
secure software image, the default password for RO is userpasswd and securepasswd for RW.
For more information about changing the passwords, see Configuring Security on Ethernet RoutingSwitch 3500 Series.
EDM window
The EDM window contains the following parts:
1. navigation tree—the navigation pane on the left side of the window that displays available
command folders in a tree format
2. menu bar—the area at the top of the window that displays primary and secondary tabs that
you accessed during the session; the tabs remain available until you close them
3. toolbar—the area just below the menu bar that provides quick access to the most common
operational commands such as Apply, Refresh, and Help
December 201714
Enterprise Device Manager
4. work area—the main area on the right side of the window that displays the dialog boxes
where you view or configure switch parameters
Note:
Depending on your hardware model, information displayed may appear different than the figure
shown in this section.
Figure 1: EDM window
Device Physical View
When you access EDM, the first panel in the work area displays a switch summary view. The tab
behind the summary view is a real-time physical view of the front panel of a device or stack called
the Device Physical View.
Objects in the Device Physical View are
• a stand-alone switch, called a unit
• a switch stack, called a chassis
• a port
From the Device Physical View you can
• determine the hardware operating status
• select a switch or a port to perform management tasks on specific objects or view fault,
configuration, and performance information for specific objects
To select an object, click the object. The system outlines the object in yellow, indicating that the
object selected.
The conventions on the device view are similar to the actual switch appearance except that LEDs in
Device Physical View do not blink. The LEDs and the ports are color-coded to reflect hardware
status. Green indicates the port is up and running; red indicates that the port is disabled.
December 201715
Fundamentals
From the menu bar you can click the Device Physical View tab to open the Device Physical View
any time during a session.
Figure 2: Device Physical View
Note:
Depending on your hardware model, your switch may appear different than the figure shown in
this section.
December 201716
Chapter 4:Connecting to the switch
Connecting a terminal to the switch
This procedure describes the steps to connect a terminal to the console port on the switch.
Before you begin
To use the console port, you need the following equipment:
• Terminal with AC power cord and keyboard. Any terminal or PC with an appropriate terminal
emulator can be used as the management station. For more information, see Quick InstallGuide for Ethernet Routing Switch 3600 Series for a list of the terminal emulation settings that
must be used with any terminal emulation software used to connect to the switch.
• Use the RJ-45 console cable to connect the switch console port to your management terminal.
The maximum length for the console port cable is 25 feet (8.3 meters).
For more information, see Installing Ethernet Routing Switch 3600 Series for console port pinout information. You can use the pin-out information to verify or create a console cable for use
with your maintenance terminal.
Procedure
1. Connect one end of the serial cable to the connector on the terminal or PC.
2. Connect the other end of the serial cable to the console port on the switch.
3. Turn the terminal or PC on.
4. Set the terminal protocol on the terminal or terminal emulation program to VT100 or VT100/
ANSI.
5. Connect to the switch using the terminal or terminal emulation application. The switch
banner appears when you connect to the switch through the console port.
6. Press Ctrl+Y and type the following CLI commands:
enable
install
The setup utility prompts you to enter the information requested as shown below.
#########################################################################
Welcome to the ERS3600 setup utility.
You will be requested to provide the switch basic connectivity settings.
After entering the requested info, the configuration will be applied and
stored into the switch NVRAM.
Once the basic connectivity settings are applied, additional configuration
December 201717
Connecting to the switch
can be done using the available management interfaces.
Use Ctrl+C to abort the configuration at any time.
Please provide the Quick Start VLAN <1-4094> [1]:
Please provide the in-band IP Address[192.168.1.1]:
Please provide the in-band sub-net mask[255.255.255.0]:
Please provide the Default Gateway[0.0.0.0]:
Please provide the Read-Only Community String[**********]:
Please provide the Read-Write Community String[**********]:
Please provide the in-band IPV6 Address/Prefix_length[::/0]:
Please provide the in-band IPV6 Default Gateway[::]:
Do you want to enable the DHCP server? y/n [n]:
#########################################################################
Basic stack parameters have now been configured and saved.
The Install script consists of a series of prompts that are used to set up the minimum
configuration information.
You must enter the following information when prompted:
• IP address
• Subnet mask
• Default gateway
• Read-only community string
• Read-write community string
• Quick start VLAN
• IPV6 address/prefix
• IPV6 default gateway
• DHCP server information (optional)
Before you begin
• Connect to the switch using the terminal or terminal emulation application.
Procedure
1. Press
CTRL + Y to obtain a CLI prompt.
2. Enter enable
3. Enter install
December 201718
Configuring with Quick Start using CLI
The switch setup utility banner appears.
4. Enter VLAN ID for the Quick Start at the following prompt:
Please provide the Quick Start VLAN <1–4094> [1]:
5. Enter the IP address at the following prompt:
Please provide the in-band IP Address [192.0.2.1]:
6. Enter the sub-net mask address at the following prompt:
Please provide the in-band sub-net mask [255.255.255.0]:
7. Enter the default gateway IP address at the following prompt:
Please provide the Default Gateway [0.0.0.0]:
8. Enter the read only community string at the following prompt:
Please provide the Read-Only Community String [**********]:
9. Enter the read write community string at the following prompt:
Please provide the Read-Write Community String [**********]:
10. Enter the in-band IPv6 address at the following prompt:
Please provide the in-band IPV6 Address/Prefix_length [ : :/0]:
11. Enter the in-band IPv6 default gateway at the following prompt:
Please provide the in-band IPV6 Default Gateway [ : :]:
12. At the Do you want to enable the DHCP server? prompt, enter Y to enable the
DHCP server, OR leave the prompt at N if you do not want to enable the DHCP server.
Successful completion displays the following message: Basic stack parameters have
now been configured and saved.
Example
###############################################################################
Welcome to the ERS3500 setup utility.
You will be requested to provide the switch basic connectivity settings.
After entering the requested info, the configuration will be applied and
stored into the switch NVRAM.
Once the basic connectivity settings are applied, additional configuration
can be done using the available management interfaces.
Use Ctrl+C to abort the configuration at any time.
Please provide the Quick Start VLAN <1-4094> [1]:
Please provide the in-band IP Address[192.0.2.1]:
Please provide the in-band sub-net mask [255.255.255.0]:
Please provide the Default Gateway[0.0.0.0]:
Please provide the Read-Only Community String[**********]:
Please provide the Read-Write Community String[**********]:
Please provide the in-band IPV6 Address/Prefix_length[::/0]:
Please provide the in-band IPV6 Default Gateway[::]:
Do you want to enable the DHCP server? y/n [n]:
December 201719
Connecting to the switch
###############################################################################
Basic stack parameters have now been configured and saved.
Perform this procedure to configure Quick Start to enter the setup mode through a single screen.
Procedure
1. From the navigation tree, click Administration.
2. In the Administration Tree, click Quick Start.
3. In the In-Band Switch IP address, type a switch address.
4. In the In-Band Subnet Mask dialog box, type a subnet mask.
5. In the Default Gateway dialog box, type an IP address.
6. In the Read-Only Community String box, type a character string.
7. In the Re-enter to verify dialog box immediately following the Read-Only Community String
box, retype the character string from Step 6.
8. In the Read-Write Community String dialog box, type a character string.
9. In the Re-enter to verify dialog box immediately following the Read-Write Community String
box, retype the character string from Step 8.
10. In the Quick Start VLAN dialog box, type a VLAN ID.
11. To enable the DHCP Server, select the ServerEnable check box and enter the DHCP server
information.
12. Click Apply.
December 201720
Example
Configuring the terminal
Configuring the terminal
You can configure the switch terminal settings to suit your preferences for the terminal speed and
display.
About this task
Use the following procedure to configure terminal settings including the terminal connection speed,
and terminal display width and length, in number of characters.
Important:
After you modify the terminal configuration, the new settings are applied to the current active
session and to all future sessions (serial, telnet or SSH). Terminal configuration change does
not affect open concurrent sessions.
Procedure
1. Log on to CLI to enter User EXEC mode.
2. At the command prompt, enter the following command:
The following table describes the parameters for the terminal command.
VariableValue
speed {2400|4800|9600|19200|38400}Sets the transmit and receive baud rates for the
terminal. You can set the speed to one of the five
options shown.
DEFAULT: 9600
length <1–132>Sets the length of the terminal display in characters.
RANGE: 1 to 132
DEFAULT: 24
width <1–132>Sets the width of the terminal display in characters.
RANGE: 1 to 132
DEFAULT: 79
BootP automatic IP configuration and MAC address
The switch supports the Bootstrap protocol (BootP). You can use BootP to retrieve an ASCII
configuration file name and configuration server address. With a properly configured BootP server,
the switch automatically learns its assigned IP address, its subnet mask, and the IP address of the
default router (default gateway).
The switch has a unique 48-bit hardware address, or MAC address, that is printed on a label on the
back panel. Use this MAC address when you configure the network BootP server to recognize the
switch BootP requests.
The BootP modes supported by the switch are:
• BootP or Last Address mode
• BootP or Default IP
• BootP Always
• BootP Disabled
December 201722
Setting user access limits using CLI
Important:
Whenever the switch is broadcasting BootP requests, the BootP process eventually times out if
a reply is not received. When the process times out, the BootP request mode automatically
changes to BootP or Default IP mode. To restart the BootP process, change the BootP request
mode to any of the following modes:
• Always
• Disabled
• Last
• Default-ip
Setting user access limits using CLI
The administrator can use CLI to limit user access by creating and maintaining passwords for web,
telnet, and console access. This is a two-step process that requires that you first create the
password and then enable it.
Setting the system user name and password using CLI
Use the following procedure to configure the system user name and password for access through
the serial console port and Telnet. This procedure supports only one read-only and one read-write
user on the switch.
Procedure
1. Enter Global Configuration mode:
enable
configure terminal
2. At the command prompt, enter the following command:
username <username> <password> [<ro | rw>]
3. To set the username and password to the system default settings, enter the following
command:
default username [<ro | rw>]
Note:
After you configure the user name and password with the username command, you
can update the password without changing the username by using the cli password
command, the console interface, or EDM.
December 201723
Connecting to the switch
Variable definitions
The following table describes the parameters for the username command.
VariableDefinition
<username> <password>Enter your user name for the first variable, and your
password for the second variable. The default user
name values are RO for read-only access and RW
for read/write access.
ro|rwSpecifies that you are modifying the read-only (ro)
user name or the read-write (rw) user name. The
ro/rw variable is optional. If it is omitted, the
command applies to the read-only mode.
Enabling and disabling passwords
After you set the read-only and read-write passwords, you can individually enable or disable them
for the various switch-access methods.
Procedure
1. Enter Global Configuration mode:
enable
configure terminal
2. Enter the following commands to configure the password for selected access or a specific
authentication type:
The following table describes the parameters for the cli password command.
VariableDefinition
read-only | read-writeModifies the read only password or the read/write
password.
<password>Specifies the password.
Important:
This parameter is not available when Password
Security is enabled, in which case the switch
prompts you to enter and confirm the new
password. For information about password
Table continues…
December 201724
Setting user access limits using Enterprise Device Manager
VariableDefinition
security, see Configuring Security on Ethernet
Routing Switch 3600 Series.
serial | telnetModify the password for serial console access or for
Telnet access.
none | local | radius | tacacsIndicates the password type being modified:
• none: disable the password
• local: uses the locally defined password for serial
console or Telnet access
• radius: uses RADIUS authentication for serial
console or Telnet access
• tacacs: uses TACACS+ authentication,
authorization, and accounting (AAA) services for
serial console or Telnet access
Setting user access limits using Enterprise Device
Manager
You can use Enterprise Device Manager (EDM) to limit user access by creating and maintaining
passwords for web, telnet, and console access.
Configuring a console password using EDM
Use this procedure to configure a Console password for an individual switch.
Procedure
1. From the navigation tree, double-click Security to open the Security tree.
2. From the Security tree, click Web/Telnet/Console.
3. In the work area, click the Console Password tab.
4. In the Console Switch Password Setting, select a value from the Console Password Type
list.
5. In the Read-Only Switch Password dialog box, type a character string.
6. In the Re-enter to verify dialog box for the Read-Only Switch Password, retype the
character string.
7. In the Read-Write Switch Password dialog box, type a character string.
December 201725
Connecting to the switch
8. In the Re-enter to verify dialog box for the Read-Write Switch Password, retype the
character string.
9. On the toolbar, click Apply.
Field descriptions
Use the descriptions in the following table to configure the console switch password.
VariableDefinition
Console Stack Password TypeSpecify the type of password to use. Values include:
• none—Disables the password
• Local Password—Use the locally-defined
password for serial console access
• RADIUS Authentication—Use RADIUS
authentication for serial console access
• TACACS Authentication—Use TACACS+
authentication, authorization and accounting (AAA)
services authentication for console access
Read-Only Stack PasswordSpecify the read-only password for stack or switch
access.
Read-Write Stack PasswordSpecify the read-write password for stack or switch
access.
Configuring a Web and Telnet password using EDM
Use this procedure to configure a Web and Telnet password for an individual switch.
Procedure
1. From the navigation tree, double-click Security to open the Security tree.
2. In the Security tree, double-click Web/Telnet/Console.
3. In the work area, click the Web/Telnet Password tab.
4. In the Web/Telnet Switch Password Setting, select a value from the Web/Telnet SwitchPassword Type list.
5. In the Read-Only Switch Password dialog box, type a character string.
6. In the Re-enter to verify dialog box for the Read-Only Switch Password, retype the
character string.
7. In the Read-Write Switch Password dialog box, type a character string.
8. In the Re-enter to verify dialog box for the Read-Write Switch Password, retype the
character string
9. On the toolbar, click Apply.
December 201726
Customizing the opening banner
Field descriptions
Use the descriptions in the following table to configure the console switch password.
VariableDefinition
Web/Telnet Stack Password TypeSpecify the type of password to use. Values include:
• none—Disables the password
• Local Password—Use the locally-defined
password for serial console access
• RADIUS Authentication—Use RADIUS
authentication for serial console access
• TACACS Authentication—Use TACACS+
authentication, authorization and accounting (AAA)
services authentication for console access
Read-Only Stack PasswordSpecify the read-only password for stack or switch
access. The maximum length of the password is 15
characters.
Read-Write Stack PasswordSpecify the read-write password for stack or switch
access. The maximum length of the password is 15
characters.
Customizing the opening banner
You can customize the banner that appears when you connect to the switch. You can customize the
text that reads Extreme Networks. However you cannot customize the second line that reads
Enter [Ctrl]+y to begin.
The Banner Control feature provides an option to specify the banner text. If you choose not to
display the banner, the system enters the CLI command mode through the default command
interface. You do not have to press the Ctrl+y keys.
The Banner display that you select is used for subsequent console sessions. For executing the new
mode in the console, you must logout. For Telnet access, all subsequent sessions use the selected
mode.
Customizing the opening CLI banner
Specifies the banner displayed at startup; either static or custom.
Procedure
1. Enter Global Configuration mode:
enable
December 201727
Connecting to the switch
configure terminal
2. At the command prompt, enter the following command:
The following table describes the parameters for the banner command.
VariableValue
staticDisplays the default agent-banner
customDisplays the custom agent-banner
disabledSkips the agent-banner display
<1–19> LINEFills the Nth line of the custom banner (1<N<19) with
the text specified in LINE
noClears all lines of a previously stored custom banner
Displaying the current banner
Display the current banner.
Procedure
1. Enter Global Configuration mode:
enable
configure terminal
2. At the command prompt, enter the following command:
show banner [custom | static]
Variable definitions
The following table describes the parameters for the show banner command.
Variable
staticDisplays default banner
customDisplays custom banner
(if empty)Displays static, custom or disabled status if
Value
parameter is not entered
December 201728
Configuring Simple Network Time Protocol
Configuring Simple Network Time Protocol
The Simple Network Time Protocol (SNTP) feature synchronizes the Universal Coordinated Time
(UTC) to an accuracy within 1 second. This feature adheres to the IEEE RFC 2030 (MIB is the
s5agent). With this feature, the system can obtain the time from any RFC 2030-compliant NTP/
SNTP server.
For more information on SNTP, see Configuring Systems on Ethernet Routing Switch 3600 Series.
Procedure
1. Enter Global Configuration mode:
enable
configure terminal
2. Enter the following command:
[no] sntp server <primary | secondary> address <A.B.C.D>
Variable definitions
Use the data in the following table to use the sntp server command.
VariableDefinition
<A.B.C.D>Specifies the IP address of the primary or secondary
NTP server in the format XXX.XXX.XXX.XXX.
Configuring local time zone
Configure the time zone to use an internal system clock to maintain accurate time. The time zone
data does not include daylight saving time changes. You must configure daylight saving time.
Note:
SNTP uses Universal Coordinated Time UTC for all time synchronizations so it is not affected
by different time zones.
Procedure
1. Enter Global Configuration mode:
enable
configure terminal
2. At the command prompt, enter the following command:
[no] clock time-zone <zone> <hours> <minutes>
December 201729
Connecting to the switch
Variable definitions
The following table describes the parameters for the clock time-zone command.
VariableValue
zoneSpecifies time zone acronym that can be displayed
when showing system time; for example, EST for
Eastern Standard Time.
RANGE: Up to 4 characters
hoursSpecify the hours difference from UTC.
RANGE: —12 to + 12
minutesOptional minutes difference from UTC.
RANGE: 0–59
noDisables the clock time zone feature
Configuring daylight savings time
Configure the daylight savings time with start and end dates, or disable the daylight savings time
feature.
Procedure
1. Enter Global Configuration mode:
enable
configure terminal
2. At the command prompt, enter the following command:
The following table describes the parameters for the clock summer-time command.
Variable
zoneSpecifies the acronym to be displayed when summer
Value
time is in effect. If unspecified, defaults to the time
zone acronym.
Table continues…
December 201730
Specifying summer-time recurring dates
VariableValue
RANGE: up to 4 characters
date {<day> <month> <year> <hh:mm>} {<day>
<month> <year> <hh:mm>}
offsetNumber of minutes to add during summer time
noDisables the daylight savings time feature
The first date specifies when summer time starts,
and the second date specifies when summer time
ends.
• day — day of the month (RANGE: 1 to 31)
• month — month (RANGE: first three letters by
name)
• hh:mm — time in military format (24–hour clock), in
hours and minutes
Important:
<day> <month> parameters can also be
entered in order: <month> <day>.
RANGE: —840 to 840
Specifying summer-time recurring dates
Specify the dates that recur during the summer-time clock every year. This procedure provides
flexibility for countries where the Daylight Savings Time is different than North America.
Procedure
1. Enter Global Configuration mode:
enable
configure terminal
2. At the command prompt, enter the following command:
The following figure provides a sample of the output of the clock summer-time recurring
command.
Switch(config)#clock summer-time recurring 1 tues Jun 12:01 3 sat Sep 23:57 1
Summer time recurring is set to:
start: 1st week of June on Tuesday at 12:01
end: 3rd week of September on Saturday at 23:57
Offset: 60 minutes.
December 201731
Connecting to the switch
Variable definitions
The following table describes the parameters for the summer-time recurring command.
VariableValue
<1–5>Specifies the week of the month. The first
occurrence specifies when the recurring starts, and
the second specifies when the recurring stops.
<DAY>Specifies the day of the week as the first 3 letters of
the name. The first occurrence specifies when the
recurring starts, and the second specifies when the
recurring stops.
<MONTH>Specifies the Month using the first 3 letters of the
name. The first occurrence specifies when the
recurring starts, and the second specifies when the
recurring stops.
<hh:mm>Specifies the time in hours and minutes in military
format (24–hr). The first occurrence specifies when
the recurring starts, and the second specifies when
the recurring stops.
<1–1440>Specifies the number of minutes to add or subtract
during summer-time recurring.
Displaying the local time zone settings
Display the settings for the local time zone.
Procedure
1. Enter Global Configuration mode:
enable
configure terminal
2. At the command prompt, enter the following command:
show clock time-zone
Example
The following figure provides a sample of the output of the show clock time-zone command.
switch(config)#show clock time-zone
Time zone offset from UTC is 00:00
December 201732
Displaying the daylight savings time settings
Displaying the daylight savings time settings
Display the daylight savings time settings.
Procedure
1. Enter Global Configuration mode:
enable
configure terminal
2. At the command prompt, enter the following command:
show clock summer-time
Example
The following figure provides a sample of the output of the show clock summer-time
command.
switch(config)#show clock summer-time
Summer time recurring is set to:
start: on Tuesday in the 1st week of June at 12:01
end: on Saturday in the 3rd week of September at 23:59
Offset: 60 minutes.
Daylight saving time is disabled
Configuring a static route using CLI
Create static routes to manually configure a path to destination IP address prefixes.
Before you begin
• Enable IP routing globally.
• Enable IP routing and configure an IP address on the VLANs to be routed.
Procedure
1. Log on to CLI in Global Configuration command mode.
2. At the command prompt, enter the following command:
The following table describes the parameters for the ip route command.
December 201733
Connecting to the switch
VariableValue
[no]Removes the specified static route.
<dest-ip>Specifies the destination IP address for the route
being added.
DEFAULT:
0.0.0.0 is considered the default route.
<mask>Specifies the destination subnet mask for the route
being added.
<next-hop>Specifies the next hop IP address for the route being
added.
[<cost>]Specifies the weight, or cost, of the route being
added.
RANGE:
1–65535
[enable]Enables the specified static route.
[disable]Disables the specified static route.
[weight<cost>]Changes the weight, or cost, of an existing static
route.
RANGE:
1–65535
Enabling remote access
You can enable remote access for telnet, SSH (on SSH software images), SNMP, and webpage
access.
For more information, see Using CLI and EDM on Ethernet Routing Switch 3600 Series and
Configuring Systems on Ethernet Routing Switch 3600 Series.
About this task
Use the following procedure to enable and configure remote access to the management features of
the switch.
Procedure
1. Enter Global Configuration mode:
enable
configure terminal
2. To enable telnet remote access, enter the following command:
telnet-access enable
December 201734
3. To enable SSH remote access, enter the following command:
ssh
4. To enable SNMP remote access, enter the following command:
snmp-server enable
5. To enable webpage remote access, enter the following command:
web-server enable
Example
The following is an example of enabling telnet remote access:
Switch>enable
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#telnet-access enable
Switch(config)#
Using telnet to log on to the device
Using telnet to log on to the device
Procedure
1. From a computer or terminal, start a telnet session:
telnet <IPv4_address>
where <IPv4_address> is the IP address of the switch. The stand-alone units use the default
IP address of 192.168.1.1 and the stacking units use the default IP address of 192.168.1.2 if
the switch does not obtain its IP address from another source.
2. Enter the user ID and password when prompted.
Enabling the web server management interface
The web server must be enabled to access Enterprise Device manager (EDM). If you do not want
EDM to be accessible on the device, disable the web server. By default, the web server is enabled.
Procedure
1. Enter Global Configuration mode:
enable
configure terminal
2. At the command prompt, enter the following command:
web-server enable
December 201735
Connecting to the switch
Accessing the switch through the web interface
You can use EDM to configure and maintain your switch through a web-based graphical user
interface. You can monitor the switch through a web browser from anywhere on the network.
By default, you can access the web interface using Hypertext Transfer Protocol Secure (HTTPS)
only.
By default, the web interface uses a 15 minute time-out period. If no activity occurs for 15 minutes,
the system logs off the switch web interface, and you must reenter the password information.
For more information, see Configuring Security on Ethernet Routing Switch 3600 Series.
Before you begin
• Ensure that the switch is running.
• Note the switch IP address.
• Ensure that the web server is enabled.
• Note the user name and password.
• Open one of the supported web browsers.
For more information about the supported browsers, see Using CLI and EDM on EthernetRouting Switch 3600 Series.
About this task
Use this procedure to access the switch through a web browser.
Procedure
1. Start your web browser.
2. Type the switch IP address as the URL in the Web address field.
http://<IP Address>
OR
https://<IP Address>
3. Enter the user name.
4. Enter the password.
5. Click Log On.
Creating a VLAN using CLI
Use this procedure to create port-based or IPv6 protocol-based VLANs.
December 201736
Important:
This procedure fails if the VLAN already exists.
Procedure
1. Enter Global Configuration mode:
enable
configure terminal
2. At the command prompt, enter the following command:
vlan create 2-10,80 type port
vlan create 15 type voice-vlan
Saving the configuration
Variable definitions
The following table describes the parameters for the vlan create command.
Variable
<1–4094> | <vid_list>Enter the ID of the VLAN you want to create or enter
name <WORD>Enter the new name you want for the VLAN.
typeEnter the type of VLAN. Values include:
msti <1–7> | cistThis parameter is available only in MSTP mode. It
Value
as a list or range of VLAN IDs to create multiple
VLANs simultaneously. A VLAN ID can range from 1
to 4094..
• port — port-based VLAN
• protocol-ipv6Ether2 — IPv6 protocol-based VLAN
• voice-vlan — voice VLAN
associates the VLAN with either an MSTI instance or
the CIST.
Saving the configuration
After you change the configuration, you must save the changes. Save the configuration to a file to
retain the configuration settings.
December 201737
Connecting to the switch
Note:
File Transfer Protocol (FTP) and TFTP support both IPv4 and IPv6 addresses, with no
difference in functionality or configuration.
Before you begin
Enable the Trivial File Transfer Protocol (TFTP) on the switch.
About this task
Use this procedure to save the configuration.
Procedure
1. Enter Privileged EXEC mode:
enable
2. At the command prompt, enter the following command:
save config
Configuring system identification
About this task
You can configure system identification to specify the system name, contact person, and location of
the switch, and to add a trap receiver to the trap-receiver table.
Procedure
1. Enter Global Configuration mode:
enable
configure terminal
2. Enable the Simple Network Management Protocol (SNMP) server:
snmp-server enable
3. Configure the read-only community name:
snmp-server community ro
Note:
Enter the community string twice.
If you ran the install script to set up the configuration information, the read-only
community name is already configured.
4. Configure the read-write community name:
snmp-server community rw
December 201738
Configuring system identification
Note:
Enter the community string twice.
If you ran the install script to set up the configuration information, the read-write
community name is already configured.
5. Configure the system name:
snmp-server name <text>
6. Configure the system contact:
snmp-server contact <text>
7. Configure the location:
snmp-server location <text>
8. Configure the SNMP host to add a trap receiver to the trap-receiver table:
snmp-server host <host-ip> <community-string>
Variable definitions
Use the definitions in the following table to use the snmp-server name command.
Table 1: snmp-server name command
VariableDefinition
<text>Specify the SNMP system name value. Enter an
alphanumeric string of up to 255 characters.
Note:
On the console, the SNMP server name is
truncated. On the web interface, the full SNMP
server name appears.
Use the definitions in the following table to use the snmp-server contact command.
Table 2: snmp-server contact command
VariableDefinition
<text>Specify the SNMP system contact value. Enter an
ASCII string of up to 255 characters.
Use the definitions in the following table to use the snmp-server location command.
December 201739
Connecting to the switch
Table 3: snmp-server location command
VariableDefinition
<text>Specify the SNMP system location value. Enter an
alphanumeric string of up to 255 characters.
Use the definitions in the following table to use the snmp-server host command.
Table 4: snmp-server host command
VariableDefinition
<host-ip>Specify an IPv4 or IPv6 address for a host intended
to be the trap destination.
<community-string>If you are using the proprietary method for SNMP,
enter a community string that works as a password
and permits access to the SNMP protocol.
December 201740
Chapter 5:Configuring the switch using
CLI
Configuring the IP address
Use this procedure to configure the IP address and subnet mask for the switch or stack. You can
also use this procedure to select the boot mode for the next switch reboot.
Important:
When you change the IP address or subnet mask, you can lose connection to Telnet and the
Web. You also disable any new Telnet connection, and you must connect to the serial Console
port to configure a new IP address.
Note:
If you do not specify the stack or switch parameter, the system automatically modifies the stack
IP address when in stack mode and modifies the switch IP address when in standalone mode.
Procedure
1. Enter Global Configuration mode:
enable
configure terminal
2. At the command prompt, enter the following command:
ip address [switch|stack|unit<1–8>][<A.B.C.D>] [netmask <A.B.C.D>]
[default-gateway <A.B.C.D>]
Variable definitions
The following table describes the parameters for the ip address command.
Variable
A.B.C.DEnters the IP address or subnet mask of the switch
Value
in the format XXX.XXX.XXX.XXX; netmask is
optional.
Table continues…
December 201741
Configuring the switch using CLI
VariableValue
switch | stack | unit <1–8>Specifies whether to set the IP address for the
switch, the stack, or another unit in a stack.
netmaskSets the IP subnet mask.
default-gateway <A.B.C.D>Sets the IP address of the default gateway.
Configuring the IP address
Use this procedure to automatically obtain an in-band management IP address, subnet mask and
default gateway on the switch or stack.
About this task
When you use DHCP, the switch or stack can also obtain up to three DNS server IP addresses.
Procedure
1. Enter Global Configuration mode:
enable
configure terminal
2. At the command prompt, enter the following command:
The following table describes the parameters for the ip address sourcecommand.
Variable
bootp-alwaysAlways use the BootP server.
bootp-last-addressUse the last BootP server.
bootp-when-neededUse the BootP server when needed.
configured-addressUse the manually configured IP configuration.
dhcp-alwaysAlways use the DHCP server.
dhcp-last-addressUse the last DHCP server.
dhcp-when-neededUse DHCP client when needed.
Value
DEFAULT: bootp-when-needed
December 201742
Clearing the IP address
Clearing the IP address
Use this procedure to clear the existing IP address and subnet mask for the switch or stack or
another unit of a stack.
Important:
When you change the IP address or subnet mask, you can lose connection to Telnet and the
Web. You also disable any new Telnet connection, and you must connect to the serial Console
port to configure a new IP address.
Procedure
1. Enter Global Configuration mode:
enable
configure terminal
2. At the command prompt, enter the following command:
no ip address [switch|stack|unit<1–8>]
Configuring the IP address to the default value
The default value for the switch is 192.168.1.1 for Standalone Mode or 192.168.1.2 for Stacking
Mode.
Procedure
1. Enter Global Configuration mode:
enable
configure terminal
2. At the command prompt, enter the following command:
default ip address
Displaying IP address information
Use this procedure to display IP configurations, switch address, subnet mask, and gateway address.
Procedure
1. Log on to CLI to enter User EXEC mode.
2. At the command prompt, enter the following command:
December 201743
Configuring the switch using CLI
show ip address
Example
The following figure displays a sample output for the show ip address command.
Switch>show ip address
Configured In Use Last BootP/DHCP
------------- ------------- --------------Stack IP Address: 192.0.1.1 0.0.0.0
Switch IP Address: 192.0.1.2 192.0.1.2 0.0.0.0
Switch Subnet Mask: 255.255.255.0 255.255.255.0 0.0.0.0
Note:
The Router and DNS IP addresses are global, or common. Addresses and pools that do not
have Router and DNS addresses configured within them use these global addresses.
Changing subnet netmask value
The subnet mask is configured using procedure Configuring the IP address on page 41. Use this
procedure to change the subnet mask to the default value or clear the subnet mask.
Procedure
1. Enter Global Configuration mode:
enable
configure terminal
2. At the command prompt, enter the following command:
[default] [no] ip netmask
Variable definitions
The following table describes the parameters for the ip netmask command.
Variable
defaultSets the subnet mask to the default value
noSets the subnet mask for a switch to all zeros
Value
(255.255.255.0).
(0.0.0.0).
December 201744
Configuring the default gateway
Configuring the default gateway
Use this procedure to configure the IP default gateway address for a switch, to change the IP default
gateway address to the default address, or to clear the IP default gateway address.
Important:
When you change the IP gateway address, you can lose connection to Telnet and the Web. You
also can disable any new Telnet connection required to connect to the serial Console port to
configure a new IP Gateway address.
Procedure
1. Enter Global Configuration mode:
enable
configure terminal
2. At the command prompt, enter the following command:
[no] [default] ip default-gateway <A.B.C.D>
Variable definitions
The following table describes the parameters for the ip default-gateway command.
Variable
<A.B.C.D>Enter the IP address of the default IP gateway in the
noClears the IP address of the default IP gateway. Sets
defaultSets the IP default gateway address to all zeros
Value
format XXX.XXX.XXX.XXX.
DEFAULT: 0.0.0.0.
Important:
When you change the IP gateway, you can lose
connection to Telnet and the Web. You can also
disable any new Telnet connection required to
connect to the serial Console port to configure a
new IP Gateway address.
the IP default gateway address to zeros (0).
(0.0.0.0).
December 201745
Configuring the switch using CLI
Displaying IP configuration
This procedure is used to display the IP configuration, specifically BootP mode, switch or stack or
unit address, subnet mask, and gateway address. These parameters are displayed for what is
configured, what is in use, and the last BootP.
Procedure
1. Log on to CLI to enter User EXEC mode.
2. At the command prompt, enter the following command:
show ip [bootp][default-gateway [address [switch | stack | unit <1–
8>]][dns]
If you do not enter any parameters, the show ip command displays all IP-related
configuration information.
Example
The following figure displays a sample output of the show ip command.
Switch>show ip
Bootp/DHCP Mode: BootP Or Default IP
The following table describes the parameters for the show ip command.
Variable
bootp modeDisplays BootP-related IP information.
default-gatewayDisplays the IP address of the default gateway.
addressDisplays the current IP address.
switch | stack | unit <1–8>Specifies the current IP address of the switch or
dnsDisplays the DNS configuration.
Value
stack or specified unit.
December 201746
Chapter 6:Verification
Verification
Pinging an IP device
You can ping a device to test the connection between a switch and another network device. After
you ping a device, the switch sends an Internet Control Message Protocol (ICMP) packet to the
target device. If the device receives the packet, it sends a ping reply. After the switch receives the
reply, a message appears that indicates traffic can reach the specified IP address. If the switch does
not receive a reply, the message indicates the address does not respond.
Before you begin
The local IP address must be configured before issuing the ping command.
Procedure
1. Log on to CLI to enter User EXEC mode.
2. At the command prompt, enter the following command:
ping <IP_address>
where <IP_address> is an IPv4 or IPv6 address.
Example
The following figure shows a sample ping response.
Switch>ping 1292.0.1.1
Host is reachable
Variable definitions
The following table describes the parameters for the ping command.
Variable
<A.B.C.D > | <dns_host_name> | <WORD>Specifies the IP address, DNS host name, or IPv6
datasize<64–4096>Specifies the size of the ICMP packet to be sent. The
Value
address of the unit to test.
data size range is from 64 to 4096 bytes.
Table continues…
December 201747
Verification
VariableValue
{count <1–9999>} | continuousSets the number of ICMP packets to be sent. The
continuous mode sets the ping running until the user
interrupts it by entering Ctrl-C.
{timeout |-t} <1–120>Sets the timeout using either the timeout or -t
parameter, followed by the number of seconds the
switch must wait before timing out.
interval<1–60>Specifies the number of seconds between
transmitted packets.
debugProvides additional output information such as ICMP
sequence number and trip time.
source<A.B.C.D>Specifies the source IP address of the packet. Must
be a configured address on the switch.
ttl<0–255>Specifies the maximum hop limit for the packet.
Range of 0 to 255.
Displaying the agent and diagnostic software load
Display the currently loaded and operational software status for agent and diagnostic loads, either
individually or combined, for a switch or stack.
Procedure
1. Log on to CLI to enter User EXEC mode.
2. At the command prompt, enter the following command:
show boot [diag] [image]
Example
The following figure provides a sample output of the show boot command.
Switch>show boot
Unit Agent Image Active Image Diag Image Active Diag
----- ----------- ------------ ---------- ----------1 5.2.0.037 5.2.0.037 1.0.0.11 1.0.0.11
2 5.2.0.037 5.2.0.037 1.0.0.11 1.0.0.11
3 5.2.0.037 5.2.0.037 1.0.0.11 1.0.0.11
* - Stack requires reboot for new Active Image to be made operational.
# - Stack requires reboot for new Diag to be made operational.
Variable definitions
The following table describes the parameters for the show boot command.
Variable
diagDisplays information for the diagnostic load only.
imageDisplays information for the image load only.
Value
December 201748
Displaying RMON Alarms using CLI
Displays information about RMON alarms.
Procedure
1. Log on to CLI in Global Configuration command mode.
2. At the command prompt, enter the following command:
show rmon alarm
Verification
December 201749