Extreme Networks Summit X440-G2-24p-10GE4, Summit X440-G2-24t-10GE4, Summit X440-G2-12t-10GE4, Summit X440-G2-48t-10GE4, Summit X440-G2-48p-10GE4 Quick Reference

...
X440-G2 Series Switch Quick Reference
For complete installation instructions see the Extreme Networks Summit Family Hardware Installation Guide at:
www.extremenetworks.com/documentation
Hardware Compo nents
The following figures display the front and rear panel ports, LEDs, and hardware components on a typical X440-G2 switch. See the Extreme Networks Summit Family Hardware Installation Guide for component details.
Figure 1 X440-G2 Sample Front Panel
Figure 2 X440-G2 Sample Rear Panel (AC power)
Figure 3 X440-G2 Sample Rear Panel (DC power)
Installation Site Requirements
The installation site must be within reach of the network cabling and meet the requirements listed below:
• Appropriate grounded power receptacles must be located within six feet of the site.
• A temperature of between 0°C (32°F) to 60°C (140°F) with fluctuations of less than 10°C (18°F) per hour must be maintained for the following X440-G2 switches: – X440-G2-12t8fx-GE4 – X440-G2-24fx-GE4 – X440-G2-24t-GE4 For all other X440-G2 series switches, a temperature of between 0°C (32°F) and 50°C (122°F) must be maintained at the installation site with fluctuations of less than 10°C (18°F) per hour.
Handling the Switch
To prevent electrostatic damage, attach an electrostatic discharge (ESD) wrist strap to your wrist before handling the switch.
Unpack the switch as follows: 1 Remove the packing material protecting the switch. 2 Remove the tape seal on the non-conductive bag to remove the
switch.
Electrical Hazard: Only qualified personnel should perform installation procedures. Risques d’électrocution: Seul un personnel qualifié doit effectuerles procédures d'installation.
Note: Switch models X440-G2-12t8fx-GE4, X440-G2-24fx-GE4, and X440-G2­24t-GE4 do not support stacking. The front panel stack LED on these models does not function.
1 USB port 4 10/100/1000BASE-T copper ports 2 Stack LED 5 1000BASE-X SFP ports 3 Console/Management ports 6 Shared ports
1 10GBASE-X SFP+ ports 4 Redundant power input 2 10GBASE-T copper ports 5 Grounding lug 3 AC power input socket 6 Shared ports
1 10GBASE-X SFP+ ports 4 DC power connector panel 2 10GBASE-T copper ports 5 Grounding lug 3 Redundant power input 6 Shared ports
Caution: To ensure proper ventilation and prevent overheating, leave a
minimum clearance space of 5.1 cm (2.0 in.) on both sides of the device.
Warni ng: A readily accessible disconnect device shall be incorporated in the building installation wiring.
Caution: The switch can be damaged by electrostatic discharge.
3 Perform a visual inspection of the switch for any signs of
physical damage. Contact Extreme Networks if there are any signs of damage. See “Getting Help” for more information on contacting Extreme Networks.
Installing the Summit X440-G2 Series Switch
You can install a Summit X440-G2 Series switch in a rack. There are four possible rack mounting configurations, depending upon whether:
• The switch I/O ports or the power supply side of the device face front
• The device is mounted flush with the rack p osts or mid -mounted
Secure the X440-G2 Series switches to the Rack
To secure the Summit X440-G2 Series switches to the rack: 1 Attach the mounting brackets to the sides of the switch using
six screws for each bracket.
2 Align the rack mount ear holes with the front rack post holes. 3 Secure the Summit X440-G2 Series switches to each rack post
with two screws or fasteners appropriate to the rack.
Install Optical Transceivers
This installation procedure applies to all optical transceivers. To install a transceiver in a Summit X440-G2 Series switch:
1 Attach the anti-static wrist strap to your wrist and connect the
metal end to an appropriate ground point on the rack.
2 Remove the optical transceiver from the packaging. 3 If there is a protective dust cover on the connector, remove it at
this time.
4 Hold the optical transceiver so that the connector will seat
properly.
5 Carefully align the optical transceiver with the port slot. 6 Push the optical transceiver into the port slot until the
transceiver clicks and locks into place.
Connect Power to the Switch
You can connect to a single, primary source of power, or to two sources of power for redundancy.
To power-up your X440-G2 Series switch, do the following: 1 For AC powered units, connect the AC power cord to the AC
power input socket on the switch and an AC power outlet.
2 For DC powered switches, first verify the DC circuit is de-
energized and then do the following: a Identify the grounding lug on the back of the switch. The
grounding lug is the middle screw of the power connector panel, identified by the international symbol for earth ground.
b Connect the spade terminal end of the ground wire to the
grounding lug of the power connector panel on the rear of the switch and the other end to a reliable earth ground.
c Connect the DC power input cables to the DC input terminal
block on the rear of the switch.
d Energize the circuit.
3 If applicable, attach the cable from your redundant power
supply (RPS) into the X440-G2 Series switch’s redundant power supply receptacle.
4 Once power is connected, verify that the PSU LED and RPS LED
(if applicable) turns green. If the PSU and RPS LEDs do not turn green, refer to the Extreme Networks Summit Family Hardware Installation Guide for troubleshooting information.
Caution: Before rack-mounting the device, ensure that the rack can support it without compromising stability. Otherwise, personal injury and/or equipment damage may result.
Note: The rack mounting brackets provide two holes for securing the Summit X440-G2 Series switches to the rack. Use two screws or fasteners appropriate to your rack on each side when securing the X440-G2 Series switch to the rack.
Warni ng: LASER RADIATION Fiber-optic ports use Class 1 or Class 1M lasers. DO NOT EXPOSE USERS OF TELESCOPIC OPTICS Do not use optical instruments to view the laser output. The use of optical instruments to view laser output increases eye hazard. Use only UL/CSA recognized pluggable modules.
Avertissements: RAYONNEMENT LASER Ports de fibres optiques utilisent des lasers de classe 1 ou de classe 1M . NE PAS exposer les utilisateurs de télescopique OPTIQUE. Ne pas utiliser d'instruments optiques pour voir la sortie du laser. L'utilisation de instruments optiques pour afficher la sortie laser augmente les risques oculaires. Utilisez uniquement UL / CSA reconnue modules enfichables.
Warni ng: Extreme Networks power supplies do not have switches for turning the unit on and off. Disconnect all power cords to remove power from the device. Make sure that these connections are easily accessible.
Warni ng: A dedicated Listed circuit breaker rated at 15A is to be used for each power supply connection.
Warni ng: Always make sure that the DC circuit is de-energized before connecting or disconnecting DC power cables.
Note: Installing the system as described in this guide meets the protective earth grounding requirements of the National Electrical Code (NEC) UL 60950 and IEC 60950 standards. However, in some cases, it may be necessary to use an alternative grounding method. In these cases, a 14 AWG wire can be connected between the ground lug on the chassis and a nearby building ground point.
Selection of Power Cords
Extreme Networks does not include any power input cords. To purchase the correct power cord for your specific country, refer to
www.extremenet works.com/product /powercords/ for power cord
details to purchase a cord from Extreme Networks or your local supplier.
Initial Network Connection and Configuration
Once you have connected power to the switch and verified LED activity, complete the setup process as follows:
1 Connect a management station to the console port using either
an Ethernet to serial adapter or DB-9 serial cable
2 Verify that the system LEDs are on (solid green or blinking
green).
3 Using PuTTY, TeraTerm, or other terminal emulator, connect to
the switch using the serial port connection. Be sure that your serial connection is set properly: –9600 baud – 8 data bits –1 stop bit
4 Using the console session, perform the following:
a At the password prompt, press ENTER (RETURN) twice. b Enter user: admin c For the initial password, simply press ENTER. d Follow the screen prompts for initial configuration. eEnter the show version command. Record the switch serial
number. The following is example output with the serial number in bold:
Transit.3 # show version Switch : 800444-00-05 1208G-00882 Rev 5.0 BootROM:
5 Go to Extreme Networks e-support at https://
esupport.extremenetworks.com
6 After logging in, go to the product registration page: http://
extrwebapps.extremenetworks.com/Webapps/Public/
ProductReg/.
7 Enter the serial number of the switch. 8 Download the software to your pc from the software download
page at the esupport website: https://
esupport.extremenetworks.com/eservice_enu/
start.swe?SWECmd=Lo gin&SWEPL=1&SWETS=
9 Connect back to the switch via the console port and connect a
Ethernet cable to the management port on the switch to your
PC. 10 You might need to reset the IP address on your PC to some
address (for example, 10.10.10.10 255.255.255.0) to avoid
IP conflict. 11 At the switch, set the IP address of the switch (for example,
enter: con mgmt ipa 10.10.10.9/24). 12 Enter save config to save your configuration. 13 Start a TFTP session using a program such as TFTPD64. Point
the TFTP server to your PC IP address and EXOS image file
saved on your PC. 14 At the switch, download the new software to the switch
(example : download image 10.10.10.10 summitX-
15.4.1.3-patch1-9.xos).
15 Install the software after it loads by typing Y when prompted if
you want to install the load. 16 When the download and install finishes, instruct the switch to
reboot when prompted by entering: reboot.
Optional CLI Commands
Once logged into the switch you can create new VLANs by issuing the following two commands:
• create vlan <vlan name>
• configure vlan <vlan name> tag XXXX (replace XXXX
with the VLAN tag number - options are 1-4096) These two commands will create a VLAN, give it a logical name, and assign a tag number. To configure a Default Gateway in the Extreme Networks CLI, enter: configure iproute add default <IP Address>
Port Configuration CLI Commands
For additional port configuration CLI commands, refer to the Extreme XOS Command Reference Guide at:
www.extremenetworks.com/documentation.
Specifications
Temperature and Humidity
Operating Temperature:
X440-G2-12t8fx-GE4, X440-G2-24fx-GE4, and X440-G2-24t-GE4: 0°C (32°F) to 60°C (140°F)
All other X440-G2 switches: 0°C (32°F) to 50°C (122°F)
Storage Temperature:
-40°C to 70°C (-40°F to 158°F)
Operating Relative Humidity:
10% to 95% (non-condensing)
Power Specifications
Switch Dimensions
Interfaces
Each Summit X440-G2 Series switch has a USB, management, and console port. The following table lists the specific interfaces for each switch.
X440-G2-24t-10GE4 (Part # 16532)
100-240Vac, 0.45 A max., 50-60Hz
X440-G2-24p-10GE4 (Part # 16533)
100-240Vac, 4.9 A max., 50/60Hz
X440-G2-48t-10GE4 (Part # 16534)
100-240Vac, 0.7 A max., 50-60Hz
X440-G2-48p-10GE4 (Part # 16535)
100-240Vac, 9.2 A max., 50/60Hz
X440-G2-12t-10GE4 (Part # 16530)
100-240Vac, 0.35 A max., 50-60Hz
X440-G2-12p-10GE4 (Part # 16531)
100-240Vac, 2.6 A max., 50-60Hz
X440-G2-24t-10GE4-DC (Part # 16536)
-48V DC, 1.0 A
X440-G2-48t-10GE4-DC (Part # 16537)
-48V DC, 1.45 A
X440-G2-24x-10GE4 (Part # 16538)
100-240Vac, 0.8 A max., 50-60Hz
X440-G2-24fx-GE4 (Part # 16539)
100-240Vac, 0.65 A max., 50-60Hz
X440-G2-12t8fx-GE4 (Part # 16540)
100-240Vac, 0.5 A max., 50-60Hz
X440-G2-24t-GE4 (Part # 16541)
100-240Vac, 0.45 A max., 50-60Hz
X440-G2-24t-10GE4 4.4 cm (1.73 in) H x 44.1 cm (17.38 in) W x 25.4 cm (10.01 in) L
Unpackaged Weight: 3.66 kg (8.07 lb)
X440-G2-24p-10GE4 4.4 cm (1.73 in) H x 44.1 cm (17.38 in) W x 25.4 cm (10.01 in) L
Unpackaged Weight: 4.28 Kg (9.44 lb)
X440-G2-48t-10GE4 4.4 cm (1.73 in) H x 44.1 cm (17.38 in) W x 38.1 cm (15.01 in) L
Unpackaged Weight: 5.03 Kg (11.09 lb)
X440-G2-48p-10GE4 4.4 cm (1.73 in) H x 44.1 cm (17.38 in) W x 38.1 cm (15.01 in) L
Unpackaged Weight: 6.54 Kg (14.42 lb)
X440-G2-12t-10GE4 4.4 cm (1.73 in) H x 30.5 cm (12.01 in) W x 26.1. cm (10.28 in) L
Unpackaged Weight: 2.62 Kg (5.78 lb)
X440-G2-12p-10GE4 4.4 cm (1.73 in) H x 30.5 cm (12.01 in) W x 26.1. cm (10.28 in) L
Unpackaged Weight: 3.03 Kg (6.68 lb)
X440-G2-24t-10GE4-DC 4.4 cm (1.73 in) H x 44.1 cm (17.38 in) W x 25.4 cm (10.01 in) L
Unpackaged Weight: 3.66 kg (8.07 lb)
X440-G2-48t-10GE4-DC 4.4 cm (1.73 in) H x 44.1 cm (17.38 in) W x 38.1 cm (15.01 in) L
Unpackaged Weight: 5.02 Kg (11.07 lb)
X440-G2-24x-10GE4 4.4 cm (1.73 in) H x 44.1 cm (17.38 in) W x 25.4 cm (10.01 in) L
Unpackaged Weight: 3.64 Kg (8.02 lb)
X440-G2-24fx-GE4 4.4 cm (1.73 in) H x 44.1 cm (17.38 in) W x 25.4 cm (10.01 in) L
Unpackaged Weight: 3.76 Kg (8.29 lb)
X440-G2-12t8fx-GE4 4.4 cm (1.73 in) H x 30.5 cm (12.01 in) W x 26.1. cm (10.28 in) L
Unpackaged Weight: 2.88 Kg (6.35 lb)
X440-G2-24t-GE4 4.4 cm (1.73 in) H x 44.1 cm (17.38 in) W x 25.4 cm (10.01 in) L
Unpackaged Weight: 3.62 kg (7.98 lb)
X440-G2-24t-10GE4 (Part # 16532)
Summit X440-G2 24 10/100/1000BASE-T, 4 SFP combo, 4 10GBASE-X unpopulated SFP+, 1 Fixed AC PSU, 1 RPS port, ExtremeXOS Edge license
X440-G2-24p-10GE4 (Part # 16533)
Summit X440-G2 24 10/100/1000BASE-T POE+, 4 SFP combo, 4 10GBASE-X unpopulated SFP+, 1 Fixed AC PSU, 1 RPS port, ExtremeXOS Edge license.
X440-G2-48t-10GE4 (Part # 16534)
Summit X440-G2 48 10/100/1000BASE-T, 4 SFP combo, 4 10GBASE-X unpopulated SFP+, 2 10GE copper combo, 1 Fixed AC PSU, 1 RPS port, ExtremeXOS Edge license
X440-G2-48p-10GE4 (Part # 16535)
Summit X440-G2 48 10/100/1000BASE-T POE+, 4 SFP combo, 4 10GBASE-X unpopulated SFP+, 2 10GE copper combo, 1 Fixed AC PSU, 1 RPS port, ExtremeXOS Edge license
X440-G2-12t-10GE4 (Part # 16530)
Summit X440-G2 12 10/100/1000BASE-T, 4 10GBASE-X unpopulated SFP+, 1 Fixed AC PSU, 1 RPS port, ExtremeXOS Edge license
X440-G2-12p-10GE4 (Part # 16531)
Summit X440-G2 12 10/100/1000BASE-T POE+, 4 10GBASE­X unpopulated SFP+, 1 Fixed AC PSU, 1 RPS port, ExtremeXOS Edge license
X440-G2-24t-10GE4-DC (Part # 16536)
Summit X440-G2 24 10/100/1000BASE-T, 4 SFP combo, 4 10GBASE-X unpopulated SFP+, 1 Fixed DC PSU, 1 RPS port, ExtremeXOS Edge license
X440-G2-48t-10GE4-DC (Part # 16537)
Summit X440-G2 48 10/100/1000BASE-T, 4 SFP combo, 4 10GBASE-X unpopulated SFP+, 2 10GE copper combo, 1 Fixed DC PSU, 1 RPS port, ExtremeXOS Edge license.
X440-G2- 24x-10GE4 (Part # 16538)
Summit X440-G2 24 unpopulated 1000BASE-X SFP, 4 10/ 100/1000 combo, 4 10GBASE-X unpopulated SFP+, 1 Fixed AC PSU, 1 RPS port, ExtremeXOS Edge license
X440-G2-24fx-GE4 (Part # 16539)
Summit X440-G2 24 fixed 100BASE-FX LC connectors, 4 1GBASE-X unpopulated SFP, 1 Fixed AC PSU, 1 RPS port, ExtremeXOS Edge license
X440-G2-12t8fx-GE4 (Part # 16540)
Summit X440-G2 12 10/100/1000BASE-T, 8 fixed 100BASE­FX LC connectors, 4 1GBASE-X unpopulated SFP, 1 Fixed AC PSU, 1 RPS port, ExtremeXOS Edge license
X440-G2-24t-GE4 (Part # 16541)
Summit X440-G2 24 fixed 10/100/1000BASE-TX, 4 1GBASE­X unpopulated SFP, 1 Fixed AC PSU, 1 RPS port, ExtremeXOS Edge license
Getting Help
For additional support related to Summit X440-G2 Series switches or this document, contact Extreme Networks using one of the following methods:
Notice
Copyright © 2015 Extreme Networks, Inc. All Rights Reserved.
Legal Notices
Extreme Networks, Inc., on behalf of or through its wholly-owned subsidiary, Enterasys Networks, Inc., reserves the right to make changes in specifications and other information contained in this document and its website without prior notice. The reader should in all cases consult representatives of Extreme Networks to determine whether any such changes have been made. The hardware, firmware, software or any specifications described or referred to in this document are subject to change without notice.
Trademarks
Extreme Networks and the Extreme Networks logo are trademarks or registered trademarks of Extreme Networks, Inc. in the United States and/or other countries.
All other names (including any product names) mentioned in this document are the property of their respective owners and may be trademarks or registered trademarks of their respective companies/owners. For additional information on Extreme Networks trademarks, please see:
www.extremenetworks.com/company/legal/trademarks/
Warranty
Warranty information for X440-G2 series switches is located online at:
www.extremenet works.com/go/warran ty
Support
For product support, including documentation, visit:
www.extremenetworks.com/support/
Contact
Extreme Networks, Inc. 145 Rio Robles San Jose, CA 95134 USA Tel: +1 408-579-2800 Toll-free: +1 888-257-3000
Regulatory and Compliance Information
Federal Communications Commission (FCC) Notice
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment uses, generates, and can radiate radio frequency energy and if not installed in accordance with the operator’s manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause interference in which case the user will be required to correct the interference at his own expense.
WARNING: Changes or modifications made to this device which are not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Industry Canada Notice
CAN ICES-3 (A)/NMB-3(A)
This digital apparatus does not exceed the class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications. Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada.
World Wide Web
https://esupport.extremenetworks.com
Phone
1-800-872-8440 (toll-free in U.S. and Canada) or 1-603-952-5000 For the Extreme Networks Support toll-free number in your country:
https://esupport.extremenetworks.com
The latest image and release notes
https://esupport.extremenetworks.com
Class A ITE Notice
WARN IN G: This is a Class A product. In a domestic environment this
product may cause radio interference in which case the user may be required to take adequate measures.
Product Safety
This product complies with the following international safety standards: UL 60950-1 2nd Ed., CAN/CSA-C22.2 No.60950-1-07 2nd Ed. 2014-10, IEC 60950-1-1:2005 2nd Ed..+A1:2009+A2:2013+National Differences, EN 60950-1:2006+A11+A1+A12, 2006/95/EC Low Voltage Directive.
Optical Module Compliance
Extreme Networks pluggable optical modules and direct-attach cables meet the following regulatory requirements:
• UL and/or CSA registered component for North America
• Class 1 or Class 1M Laser Product
• FCC 21 CFR Chapter 1, Sub-chapter J in accordance with FDA & CDRH requirements
• EN 60825-1:2007, EN 60825-2:2004+A1+A2 or later, European Standard
• Application of CE Mark in accordance with 2004/108/EEC EMC Directive and 2006/95/EC Low Voltage Directive
• 47 CFR Part 15, Class A when installed into Extreme products
Korea EMC Statement (KCC)
Australia (RCM)
This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may require to take adequate measures.
Electromagnetic Compatibility (EMC)
This product complies with the following: FCC 47 CFR Part 15 Subpart B Class A (US),ICES-003 issue 5 (Canada), EN 55022 (ITE Emissions), EN 55024 (ITE Immunity), EN 61000-3-2 (Harmonics), EN 61000-3-3 (Flicker), 2004/108/EC (EMC Directive), EN 300 386 (Telecom), EN 50121-1 (Railroad), EN 55011(ISM), EN 61000-6-2 (Ind. Immunity), EN 61000-6-4 Ind. Emissions), RCM (Australia), VCCI (Japan), MSIP KCC (Korea), BSMI (Taiwan), ANATEL (Brazil), CCC (China).
VCCI Notice
This is a Class A product based on the standard of the Voluntary Control Council for Interference by Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance may arise. When such trouble occurs, the user may be required to take corrective actions.
BSMI EMC Statement — Taiwan
This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
Warn ing : The X440-12t8fx-GE4, X440-24fx-GE4, and X440-24t-GE4 may be hot to touch during normal operation.
Attentio n: Le X440-12t8fx-GE4, X440-24fx-GE4, et X440-24t-GE4 peut être chaude au toucher pendant le fonctionnement normal.
Warn ing : The X440-12t8fx-GE4, X440-24fx-GE4, and X440-24t-GE4 are designed for installation in restricted access locations. Attentio n: Le X440-12t8fx-GE4, X440-24fx-GE4, et X440-24t - GE4 sont conçus pour une installation dans des endroits à accès restreint .
Battery Warning — Taiwan
Battery Notice
Hazardous Substances
This product complies with the requirements of Directive 2011/65/EU of the European Parliament and of the Council of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment.
European Waste Electrical and Electronic Equipment (WEEE)
Notice
In accordance with Directi ve 2012/19/EU of the European Parliament on waste electrical and electronic equipment (WEEE):
1 The symbol above indicates that separate collection of electrical and
electronic equipment is required.
2 When this product has reached the end of its serviceable life, it cannot be
disposed of as unsorted municipal waste. It must be collected and treated separately.
3 It has been determined by the European Parliament that there are
potential negative effects on the environment and human health as a result of the presence of hazardous substances in electrical and electronic equipment.
4 It is the users’ responsibility to utilize the available collection system to
ensure WEEE is properly treated. For information about the available collection system, please contact Extreme Customer Support at +353 61 705500 (Ireland).
Warni ng: This product contains a battery used to maintain product information. If the battery should need replacement it must be replaced by Service Personnel. Please contact Technical Support for assistance.
Risk of explosion if battery is replaced by an incorrect type. Dispose of expended battery in accordance with local disposal regulations. Avertissements: Ce produit renferme une pile servant à conserver les renseignements sur le produit. Le cas échéant, faites remplacer la pile par le personnel du service de réparation. Veuillez communiquer avec l’assistance technique pour du soutien. Il y a risque d’explosion si la pile est remplacée par un type de pile incorrect. Éliminez les piles usées en conformité aux règlements locaux d'élimination des piles.
SUPPLEMENT TO PRODUCT INSTRUCTIONS
(Parts)
(Hazardous Substance)
(Metal Parts)
(Circuit Modules)
(Cables & Cable Assemblies)
葈 XI鉻誂盗蘟蕆I
(Power Adapter/Power
Supply)
SJ/T 11363-2006
Indicates that the concentration of the hazardous substance in all homogeneous materials in the parts is below the relevant threshold of the SJ/T 11363-2006 standard.
SJ/T 11363-2006
Indicates that the concentration of the hazardous substance of at least one of all homogeneous
materials in the parts is above the relevant threshold of the SJ/T 11363-2006 standard.
This table shows where these substances may be found in the supply chain of Extreme electronic information products, as of the date of sale of the enclosed product. Note that some of the component types listed above may or may not be a part of the enclosed product.
The Environmentally Friendly Use Period (EFUP) for all enclosed products and their parts are per the symbol shown here, unless otherwise mar ked. Certain parts may have a different EFUP (for example, battery modules) and so are marked to reflect such. The Environmentally Friendly Use Period is valid only when the product is operated under the conditions defined in the product manual.
50
Extreme Networks Summit X440-G2 Series Switches
Quick Reference
X440-G2-24t-10GE4 X440-G2-24p-10GE4 X440-G2-48t-10GE4 X440-G2-48p-10GE4 X440-G2-12t-10GE4 X440-G2-12p-10GE4 X440-G2-24t-10GE4-DC X440-G2-48t-10GE4-DC X440-G2-24x-10GE4 X440-G2-24fx-GE4 X440-G2-12t8fx-GE4 X440-G2-24t-GE4
P/N 120998-00
Loading...