Extech Instruments HDV7C-A4-60-1, HDV7C-A4-60-3 User manual

User Manual
Four-Way Articulating Probes
Models HDV7C-A4–60–1 and –3. For use with HDV700 VideoScope.
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
CAUTION
Do not insert the probe into flammable liquid or gas.
This product is designed for industrial use only. It is not intended for use in hu­man or other biological inspection.
To clean the probe, wipe with a soft cloth dampened with a mild detergent and clean water. Do not use abrasive detergents, corrosives (alcohol), or solvents to clean the probe. Use a high quality lens cleaning fluid and a lint-free swab to clean the camera and worklight lenses.
Do not disassemble the product, damage to the product and electrical shock may occur.
Avoid direct sun exposure. Store in a cool, dry, and well-ventilated area.
The probe contains sensitive circuitry that controls the optics and electronics of the camera. Do not strike the probe or allow it to impact objects forcefully.
The following liquids have been approved for sub­mersion of the camera probe: Brake and transmis­sion fluid, diesel fuel, unleaded gasoline, engine oil, and CPC hydraulic fluid (46AWS).
Thank you for selecting the Extech four-way articulating camera probe. This probe is intended for use with the HDV700 VideoScope.
The probe is manually controlled by its joystick, control buttons, and lock switch. The probe is also controlled by the HDV700 touch­screen for capturing camera images and video, image manipulation, and other functions as described in the HDV700 User Manual avail­able at the support site (see Support section).

Safety

Safety Note

Please read and understand all safety cautions before use.
Find Quality Products Online at: sales@GlobalTestSupply.com
#NAS100127; r. AB/87924/87926; en-US
www.GlobalTestSupply.com
1

Probe Description

1. Joystick articulation control
2. HDV700 Connecting cable
3. Stabilizing stand
4. Hand grip
5. Image enhancement button
6. Camera probe
7. Articulation locking switch
8. Image rotation (90° clockwise) button
9. Image reflection filter button
1. Align the white dot on the probe connector with the white dot on the HDV700 monitor connector.
2. Plug the probe into the monitor unit, ensuring proper alignment and full insertion.
3. Tighten the collar nut to secure the connection. Do not overtighten.

Connect the Probe

Carefully connect the probe to the HDV700 as detailed below. Al­ways switch the HDV700 power off before connecting the probe.
#NAS100127; r. AB/87924/87926; en-US
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
2

Probe Controls

Articulation Lock

to rotate the image 90°.
to activate an image filter that reduces reflections from shiny surfaces and reduces particle arti­facts on the camera image.

Articulation Joystick

Use the joystick (1) to move the probe neck in four directions as shown in the illustration below. The thumb is typically used to move the joystick while the hand grips the control unit. Set the control unit’s stabilizing base (3) on a firm platform for convenience.
Move the probe slowly and carefully; stop moving in a specific di­rection if resistance is detected. Keep the probe as straight as pos­sible and keep the probe neck at 0° articulation when moving into and out of an inspection area.
Move the locking switch (7) to the locked position (to the right), to freeze the probe neck in place. Move the switch to the left to re­lease the lock. Do not lock the probe neck at an angle when insert­ing or removing the probe from the inspection area, this can bind the probe in the inspection area.

Light Enhancement Button

Press the light enhancement button (5) to highlight the darker areas of a camera image.

Rotation Button

Use the rotation button (8)

Anti-Reflection Button

Press the reflection filter button (9)
#NAS100127; r. AB/87924/87926; en-US
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
3

HDV700 Controls

1. Reflective mirror
2. Worklight opening. Align the worklight with the opening
3. Threaded probe connection
Remove the camera protective cover by rotating it counter-clockwise.
Turn the silver alignment sleeve clockwise to move to the right, exposing the worklight.
The HDV700 touch-screen offers additional functions and control of the probe such as recording images and video, split-screen views, image rotation, and more, as covered in the HDV700 user manual.

Mirror Accessory

The supplied mirror accessory provides a side view camera image. Use the HDV700 touch-screen to select forward and side camera views and to control the worklights (see HDV700 user manual).
Notes: Peel off the protective film from the mirror before use. Clean the mirror with a lint-free swab and a high quality lens cleaner. If necessary, remove dust and moisture with compressed air.

Side View 70° Mirror Description

Mirror Accessory Installation

#NAS100127; r. AB/87924/87926; en-US
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
4
Attach the accessory by rotating it clockwise onto the probe. Align the hole on the accessory to expose the worklight.
Rotate the silver alignment sleeve to move left or right, as needed.

Measurement Considerations

• Ensure that the camera lens cap is removed before inserting the probe into the inspection area.
• After connecting the probe to the HDV700, verify that a clear camera image is displayed. If not, remove the probe and reat­tach it ensuring correct orientation and a tight seal.
• Do not force the probe through an inspection area if resistance is detected. Check the nature of the resistance and clear it as necessary before continuing.
• When the inspection is complete, remove the probe from the in­spection area. To avoid probe binding in the inspection area, keep the probe straight and a 0° probe neck articulation angle.
• Clean the probe with a damp cloth and mild detergent as needed. Clean the camera, mirror, and worklight lenses using a high quality cleaning fluid and lint-free swabs.
• Attach the protective lens cap when storing.
• Coil the probe carefully with as wide an arc as is possible when fitting into its protective case.

Specifications

Camera image resolution
Frame rate 30 frames per second (fps)
Camera accessories Side view mirror attachment
Probe head and probe body diameter
Probe head length 0.93 in. (23.5 mm)
#NAS100127; r. AB/87924/87926; en-US
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
640 x 480 pixels
0.24 in. (6 mm)
5
Probe length 3.3 ft. (1 m) (HDV7C-A4–60–1)
9.8 ft. (3 m) (HDV7C-A4-60–3)
Articulation Four–way articulation with 360° movement
Probe head material
Probe body material Stainless steel mesh
Worklights LED lamps around camera lens and one
Field of View (FOV)
Depth of Field (DOF) 0.4 to 4.0 in. (1 to 10 cm)
Operating and Storage temperature
Approved liquids for probe immersion
Ingress protection Probe tip and body: IP 67 (IEC 60529)
Stainless steel
side-view worklight for use with the supplied mirror accessory.
87.1°
14to 120(-10to 60)
Brake and transmission fluid, diesel fuel, un­leaded gasoline, engine oil, CPC hydraulic fluid (46AWS), and water.
Protected from submersion in water up to 3.3 ft (1 m) for 30 minutes maximum. In use: rain, splashes, and accidental submersion

Two-Year Warranty

FLIR Systems, Inc. warrants this Extech brand instrument to be free of defects in parts and workmanship for two years from date of shipment (a six-month limited warranty applies to sensors and cables).
#NAS100127; r. AB/87924/87926; en-US