Extech Instruments EX600 Series Catalog Page

25
400A True RMS Dual Input Clamp Meters
EX600 Series True RMS 400A Dual Input Clamp Meters + NCV
Built-in dual Type K thermocouple inputs for T1, T2, and T1-T2 differential temperature measurement
• True RMS for accurate AC measurements
• 1.25" (32mm) jaw opening for conductors up to 500MCM
• Built-in non-contact Voltage detector with LED alert
• DC Current function ideal for automotive, heavy equipment and marine applications
• Built-in non-contact IR Thermometer (model EX623) with laser pointer for locating hot spots with 8 to 1 distance to target ratio
• 40,000 count multimeter functions for DC Voltage, Resistance, Capacitance, and Frequency for high resolution over wider ranges
• Data Hold plus fast Peak Hold of current surges during motor startup
• Measures motor capacitors to 40,000µF
• Rugged double molded housing
• Auto power off with audible alert and disable function
• Autoranging with manual override
• 1yearwarranty
• Complete with CAT III-600V, double molded test leads, 9V battery, two general purpose Type K bead wire probes and case
SPECIFICATIONS
EX613 EX623
AC/DC Current (Max Res.) 400.0A AC/DC (10mA) 400.0A AC/DC (10mA)
Basic ACA accuracy ±1.5% ±1.5% AC/DC Voltage (Max Res.) 600V (0.1mV)/600V (0.01mV) 600V (0.1mV)/600V (0.01mV) DC µA Current (Max Res.) 4000µA (0.01µA) 4000µA (0.01µA) Resistance (Max Res.) 40.000M(0.01) 40.000M(0.01) Capacitance (Max Res.) 40mF (0.01nF) 40mF (0.01nF) Frequency (Max Res.) 40MHz (0.001Hz) 40MHz (0.001Hz) Temperature - Type K -58 to 1832°F (-50 to 1000°C) -58 to 1832°F (-50 to 1000°C) Temperature - IR -58 to 518°F (-50 to 270°C) Diode (2.8V)/ Continuity Yes Yes Duty Cycle 0.5 to 99.0% 0.5 to 99.0%
Dimensions 9x3.1x1.9" (229x80x49mm) 9x3.1x1.9" (229x80x49mm) Weight 10.7oz (303g) 10.7oz (303g)
ORDERING
EX613 ÿ
True RMS 400A 400AC/DC Clamp Meter
EX623
ÿ
True RMS 400A AC/DC Clamp Meter + IR
TL810 Electrical Test Lead Kit TL803 Standard Test Leads TP200 Type K Clamp Probe (212°F/100°C) 480172 AC Line Splitter
Built-in IR Thermometer for quick and safe non-contact temperature measurements.
Non-Contact Voltage Detection.
Dual Type K Inputs for taking differential temperature readings needed for superheat measurements.