9797
Thermo-Anemometers/Environmental Meters
EN100/EN150
Environmental
Meters with UV*
11-in-1 meters
• Replaceable low friction vane
• Barometric Pressure and
Altitude functions
• Data Hold and Auto power off
• Complete with built-in sensors,
wrist strap, and CR2032 battery.
(Optional EN100-TP probe
measures to 158°F/70°C)
EN100 Additional Features
• Measures light level with
Auto-rotating display
*EN150 Additional Features
• Measures UV light level
45170/45170CM
Environmental
Meters
4-in-1 or 5-in-1 meter
• Auto-rotating display
• Low friction vane wheel
• Capacitance humidity sensor
• Type K input (Probe sold
separately - see
p. 41 and 70)
• Utilizes precision photo
diode and correction filter
• MAX/MIN and Data hold
• Complete with wrist
strap and 9V battery
• Model 45170CM also
measures Air Flow (CFM/CMM)
EN300
Environmental
Meter
5-in-1 Meter & PC interface
• Auto-rotating display
• Low friction vane wheel
• Capacitance humidity sensor
• Thermistor for ambient
temperature and Type K
input (Probe sold separately
- see
p. 41 and 70)
• Utilizes precision photo
diode and correction filter
• Sound Level measurement
meets IEC 61672 class 2
• MAX/MIN and Data hold
• Complete with 6 AAA
batteries; Optional AC adaptor
UA100-240 & software 407001
ÿ EN100 |þEN150 ÿ 45170 |þ 45170CM EN300 SPECIFICATIONS
80 to 3940 (1) 80 to 5910 (1) 80 to 5910 (1) ft/min (res.)
0.4 to 20 (0.1) 0.4 to 30 (0.1) 0.4 to 30 (0.1) m/s (res.)
1.4 to 72 (0.1) 1.4 to 108.0 (0.1) 1.4 to 108.0 (0.1) km/h (res.)
0.9 to 45 (0.1) 0.9 to 67.0 (0.1) 0.9 to 67.0 (0.1) MPH (res.)
0.8 to 38.8 (0.1) 0.8 to 58.3 (0.1) 0.8 to 58.3 (0.1) knots (res.)
— — — Beaufort Force (res.)
0.847 to 1,271,300CFM/0.024 to 36,000CMM
0.01 to 1,908,400CFM/0.001 to 54,000CMM — Air Volume (CFM/CMM)
32 to 122°F (0 to 50°C)/15 to 111°F (-9 to 44°C)
Thermistor: 32 to 122˚F/ 0 to 50˚C (0.1˚)
Type K: -148°F to 2372°F/-100°C to 1300°C
32 to 122˚F/ 0 to 50˚C (0.1˚) Temperature
10 to 95% (0.1%) 10 to 95% (0.1%) 10 to 95% (0.1%) Relative Humidity (res.)
32 to 212°F (0 to 100°C) — — Heat Index
22.3 to 120.2°F (-5.4 to 49.0°C) — — Wet Bulb
-13.5 to 120.2°F (-25.3 to 49.0°C) — — Dew Point
ÿ 0 to 1860Fc (0 to 20,000Lux) |
þ
No 0 to 1860 (0.1Fc)/0 to 20,000 (1Lux) 0 to 1860 (0.1Fc)/ 0 to 20,000 (1Lux) Light Level
ÿ No |
þ
0 to 1999µW/cm2(2 to 20mW/cm2) — — UV Level
— — 35 to 130dB (0.1dB) Sound Level (res) - A weighting
Basic Accuracy
±3% FS ±3% FS ±3% FS
Airflow
±2.5˚F, ±1.2˚C/±4%RH ±2.5˚F, ±1.2˚C/±4%RH ±2.5˚F, ±1.2˚C/±4%RH
Temperature/Relative Humidity
ÿ No |þLight: ±5% of reading Light: ±5% of reading Light: ±5% of reading/ Sound: ±1.4dB
Light/Sound
Yes Yes Yes CE approved
6.1x2.4x1.3" (156x60x33mm)/ 5oz (160g) 6.1x2.4x1.3" (156x60x33mm)/ 5oz (160g) 6.1x2.4x1.3" (156x60x33mm)/ 5oz (160g) Dimensions/Weight
Vane: 1.2" (30.5mm)D Vane: 1.2" (30.5mm)D Vane: 1.2" (30.5mm)D
1 year 1 year 1 year Warranty
EN100
EN150
45170
45170CM
Auto-rotating