Introduction
Congratulations on your purchase of the Extech DC Regulated Power Supply. These units are solid state, compact, regulated supplies suitable for many applications including bench testing, field service, hobby and telecommunication equipment use. Careful use of this device will provide years of reliable service.
Specifications
382222 382225 Display Dual Analog Metering Voltage Output, DC 3 - 15V Current Output, DC 0 - 12 Amps 0 - 25 Amps Max. Current (5 minutes) 15A 30A Overload Indicator Status LED Fuses 6A (110V), 3A (220V) 10A (110V), 5A (220V) Ripple and Noise <10mV Line Regulation < 0.05% + 10mV Load Regulation < 0.5% + 5mV < 0.6% + 10mV Cooling Method Internal Fan (Heat Activated) Power 110/220VAC 50/60Hz (switchable) Dimensions 8.1 x 4.5 x 11" (205 x 115 x 280mm) (WxHxD) Weight 18.7lbs. (8.5 kgs) 18.7lbs. (8.5kgs)
Meter Description
1. Voltage / Current meters
2. Power status LED
3. Power ON/OFF switch
4. Low current output terminals
5. Binding post output terminals
6. Voltage output adjustment
7. Overload status LED
2 382222 and 382225 v1.5 11/03
Page 3
Operation
CAUTION: The snap terminal output should be used for loads of 3 amps or less. The binding post output connectors should be used when the current may exceed 3 amps.
1. The Power Supply must be powered using the rated line voltage within +
2. Before turning the power supply ON, remove any load and set the Voltage Adjustment Knob to the full counter-clockwise position ('0' volt output).
3. The output current is dependent on the output voltage. See the Output Voltage/Output Current curve below.
4. The analog display indicates the actual current and voltage output.
5. Keep the cooling fan area clear of obstacles to prevent overheating. The fan will operate when the internal temperature reaches 70 degrees and will automatically shut off when the temperature drops to 40 degrees.
6. When the Overload LED Indicator lights, remove power to the power supply and troubleshoot the cause of the overload condition before powering up.
5%.
Calibration and Repair Services
Extech offers complete repair and calibration services for all of the products we sell. For periodic calibration, NIST certification or repair of any Extech product, call customer service for details on services available. Extech recommends that calibration be performed on an annual basis to insure calibration integrity.