Extech Instruments 380942 Instruction Manual

INSTRUCTION MANUAL
Model 380942 True RMS AC/DC 30A Mini Clamp-on Meter
True RMS AC Current and Voltage
Measure low current with high resolution to 0.1mA AC and 1mA DC
One touch DCA zero adjust
MIN/MAX and Data Hold functions
0.9” (23mm) Jaw diameter
Introduction
Congratulations on your purchase of the Extech Model 380942 DC/AC Clamp Meter. This meter is shipped fully tested and calibrated and, with proper use, will provide years of reliable service.
www.burntec.com
Model 380942 Version 2.0 July 2006
2
Specifications
General Specifications
Display 3-3/4 digit (4000 count) LCD with 40 segment bargraph Functions ACA, DCA, ACV, DCV Polarity Minus sign ( - ) indicates negative polarity Current sensor Hall effect sensor type Overload indication Left blinking digit DCA zero adjust One touch zero key Display rate 2 readings/second (20 readings/second for bargraph) Battery Two 1.5V AA batteries Operating conditions 4oF to 122oF (-10oC to 50oC); < 85% Relative Humidity Storage conditions - 4oF to 140oF (-20oC to 60oC); < 75% Relative Humidity Altitude Operate at less than 2000 meters (for indoor use only) Power consumption Approximately 10mA DC Weight 6.2 oz. (190g) including battery Dimensions 7.2 x 2.5 x 1.4” (183 x 63.6 x 35.6mm) (H x W x D) Jaw opening 0.9” (23mm) Standards IEC 1010 Category III 300V, Category II 600V
Range Specifications
Function Range Resolution Accuracy Overload
protect
4000mA 1mA 40A DC DC Current 30A 10mA
± (2.0% + 3d)
100A DC 50/60Hz 40 to 100Hz 400mA 0.1mA ±(1.5% + 5d) ±(2.0% + 5d) 40A AC 50/60Hz 40 to 1kHz 4000mA 1mA ±(2.5% + 5d) ±(3.0% + 5d) 40A AC
AC Current
(True RMS)
30A 10mA ±(2.0% + 5d) ±(2.5% + 5d) 100A AC
DC Voltage 400V 0.1V ± (1.0% + 2d) 1000V DC
50/60Hz 40 to 1kHz AC Voltage
(True RMS)
400V 0.1V ±(1.5% + 4d) ±(2.0% + 5d) 800V AC
Specification Notes
AC Voltage and Current Crest Factor: < 3
AC / DC Voltage Input Impedance: 10MΩ
www.burntec.com
Loading...
+ 4 hidden pages