Extech MM560, MM570 Operating Manual

User’s Guide
MultiMaster™ Digital MultiMeter Series With PC Interface
Models: MM560 MM570
WARRANTY
EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for three years from date of shipment (a six month limited warranty applies on sensors and cables). If it should become necessary to return the instrument for service during or beyond the warranty period, contact the Customer Service Department at (781) 890-7440 ext. 210 for authorization. A Return Authorization (RA) number must be issued before any product is returned to Extech. The sender is responsible for shipping charges, freight, insurance and proper packaging to prevent damage in transit. This warranty does not apply to defects resulting from action of the user such as misuse, improper wiring, operation outside of specification, improper maintenance or repair, or unauthorized modification. Extech specifically disclaims any implied warranties or merchantability or fitness for a specific purpose and will not be liable for any direct, indirect, incidental or consequential damages. Extech's total liability is limited to repair or replacement of the product. The warranty set forth above is inclusive and no other warranty, whether written or oral, is expressed or implied.
Copyright © 2002 Extech Instruments Corporation. All rights reserved
including the right of reproduction in whole or in part in any form.
MM Series V2.2 9/03
P/N: 7M1C-0271-A000
Introduction
Congratulations on your purchase of Extech model MM560 or MM570 digital multimeter. Properly used, this meter will provide many years of reliable service.
MultiMaster™ Meters provides high resolution, high accuracy, true rms measurements of AC Voltage and Current, DC Voltage and Current, AC+DC, Resistance, Frequency, Capacitance, Duty Cycle, dBm, Peak, %4-20, Diode, and Continuity. The MultiMaster™ also offers RS-232 PC Interface data acquisition capabilities as an option. Model MM570 offers dual input Temperature measurements and very wide bandwidth.
Safety
International Safety Symbols
Caution ! Refer to the explanation in this Manual
!
Caution ! Risk of electric shock
Earth (Ground)
Double Insulation or Reinforced insulation
Fuse
AC, Alternating Current or Voltage
DC, Direct Current or Voltage
AC+DC, Current or Voltage
Safety Precautions
1. Improper use of this meter can cause damage, shock, injury or death. Read and understand this users manual before operating the meter.
2. Make sure any covers or battery doors are properly closed and secured.
3. Always remove the test leads before replacing the battery or fuses.
4. Inspect the condition of the test leads and the meter itself for any damage before operating the meter. Repair or replace any damage before use.
5. To reduce the risk of fire or electric shock, do not expose this product to rain or moisture.
6. Do not exceed the maximum rated input limits.
7. Use great care when making measurements if the voltages are greater than 25VAC rms or 35VDC. These voltages are considered a shock hazard.
8. Always discharge capacitors and remove power from the device under test before performing Capacitance, Diode, Resistance or Continuity tests.
9. Remove the battery from the meter if the meter is to be stored for long periods.
10. To avoid electric shock, do not measure AC current on any circuit whose voltage exceeds 1000V AC.
11. Voltage checks on electrical outlets can be difficult and misleading because of the uncertainty of connection to the electrical contacts. Other means should be used to ensure that the terminals are not "live".
12. If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.
13. The product is intended only for indoor use.
PER IEC1010 OVERVOLTAGE INSTALLATION CATEGORY
OVERVOLTAGE CATEGORY III
Equipment of OVERVOLTAGE CATEGORY III is equipment in fixed installations. Note – Examples include switches in the fixed installation and some equipment for industrial use with permanent connection to the fixed installation.
OVERVOLTAGE CATEGORY IV
Equipment of OVERVOLTAGE CATEGORY IV is for use at the origin of the installation. Note – Examples include electricity meters and primary over-current protection equipment
CENELEC Directives: These instruments conform to CENELEC low-
voltage directive 73/23/EEC and Electromagnetic compatibility directive 89/336/EEC.
Specifications
DC VOLTAGE
Range
500.00 mV,
MM570 MM560
0.02% + 2d 0.03% + 2d
Accuracy
5.0000V,
50.000V
500.00V 0.04% + 2d 0.05% + 2d
1000.0V 0.05% + 2d 0.1% + 2d NMRR: >60dB @ 50/60Hz, CMRR: >120dB @ DC, 50/60Hz, Rs=1k Input impedance: 10M, 30pF nominal (80pF nominal for 500mV range)
DC CURRENT
Range Accuracy Burden Voltage
500.00µA
5000.0µA
0.15% + 20d
0.1% + 20d
0.15mV/µA
0.15mV/µA
50.000mA 0.15% + 10d 3.3mV/mA
500.00mA 0.1% + 20d 3.3mV/mA
5.0000A 0.5% + 10d 0.03V/A
10.000A* 0.5% + 20d 0.03V/A *10A continuous, 20A for 30 seconds max with a 5 minute cool down
interval
RESISTANCE
Range
500.00
5.0000k,
MM570 MM560
0.07% + 10d
0.07% + 2d
Accuracy
0.1% + 6d
50.000k,
500.00k
5.0000M
50.000M
0.2% + 6d 0.4% + 6d
2.0% + 6d 2.0% + 6d
Open circuit voltage: <1.3V (<3VDC on the 500 range)
AC & AC+DC VOLTAGE
Range
500.00mV,
MM570 MM560
1.5% + 40d
Accuracy*
20Hz to 45Hz
unspecified
5.0000V, 50.000V
500.00V, 1000.0V unspecified 45Hz to 300Hz
500.00mV 0.3% + 20d
0.8% + 60d
5.0000V, 50.000V 0.8% + 20d
500.00V, 1000.0V 0.4% + 40d 300Hz to 5kHz 300Hz to 1kHz
500.00mV 0.3% + 10d 0.8% + 40d
5.0000V, 50.000V,
0.4% + 40d 2.0% + 60d
500.00V
1000.0V 0.8% + 40d
1.0% + 40d
(300Hz-1kHz)
5kHz to 20kHz 1kHz to 20kHz
500.00mV 0.5% + 20d 1dB**
5.0000V, 50.000V 0.8% + 20d 2dB**
500.00V 0.5% + 20d 3dB**
1000.0V Unspecified Unspecified 20kHz to 100kHz
500.00mV 2.0% + 40d
Unspecified
5.0000V, 50.000V 4.0% + 40d**
500.00V, 1000.0V Unspecified
*From 5% to 10% of range: accuracy % of reading (or in dB) + 80digits **From 5% to 10% of range: accuracy % of reading (or in dB) +180digits **From 10% to 15% of range: accuracy % of reading (or in dB) +100digits
CMRR: >90dB @ DC to 60Hz, Rs=1k Input Impedance: 10M, 30pF nominal (80pF nominal for 500mV range)
Residual reading less than 50 digits with test leads shorted
AC & AC+DC CURRENT
Range
500.00µA,
5000.0µA
50.000mA,
500.00mA
5.0000A,
10.000A*
500.00µA,
5000.0µA
50.000mA,
500.00mA
5.0000A,
10.000A*
Accuracy
MM570 MM560
50Hz to 60Hz
0.5% + 50d 1.0% + 40d
40Hz to 1kHz
0.7% + 50d 1.0% + 40d
1kHz to 10kHz
Burden Voltage
0.15mV/µA
3.3mV/mA
0.03V/A
0.15mV/µA
3.3mV/mA
0.03V/A
500.00µA,
2.0% + 50d
Unspecified
0.15mV/µA
5000.0µA
50.000mA,
3.3mV/mA
500.00mA
5.0000A,
Unspecified
0.03V/A
10.000A* *10A continuous, 20A for 30 seconds max with a 5 minute cool down
interval
TEMPERATURE; T1, T2 DUAL (MM570 ONLY) Range Accuracy*
o
o
C F
-50.0°C TO 1000.0°C
-58.0°F TO 1832.0°F
0.3% + 1
0.3% + 2
*Thermocouple range and accuracy not included