MA61/MA63 True RMS 60A
Clamp Meters + NCV
Choice of AC Current or AC/DC Current model, both with high ±2% accuracy. Manual ranging clamp meters with three Current
ranges. The 6000mA range allows for low current measurements that may be used in the automotive industry. Unique VFC
(variable frequency control) mode helps troubleshoot and diagnose HVAC applications that are variable frequency driven.
Features
• True RMS for accurate readings of noisy, distorted or
non-sinusoidal waveforms
• Model MA61 — AC Current and Relative function
Model MA63 — AC/DC Current and DC Zero function
• Compact 0.7" (17mm) jaw size allows measurements
in tight locations
• Variable Frequency Control (VFC): Low pass filter
for accurate measurement of variable frequency
drive signals
• Built-in Non-Contact Voltage (NCV) detector
• Full range overload protection
• 6000 count backlit LCD display
• Data Hold freezes reading on display
• Low battery indicator and Auto Power Off feature
• CAT II-600V and CAT III-300V safety rating
• Complete with test leads, carrying case, and two
AAA batteries
Model MA61
AC Current
Model MA63
AC/DC Current
Specifications
AC Current (max resolution) 600mA, 6000mA, 60A (0.1mA) 600mA, 6000mA, 60A (0.1mA)
DC Current (max resolution) — 6000mA, 60A (1mA)
Basic accuracy ±2.0% AC: ±2.0%, DC: ±2.0%
Non-Contact Voltage (NCV) 100 to 600V AC 100 to 600V AC
AC/DC Voltage AC: 6V, 60V, 600V (1mV) / DC: 600mV, 6V, 60V, 600V (0.1mV) AC: 6V, 60V, 600V (1mV) / DC: 600mV, 6V, 60V, 600V (0.1mV)
Basic accuracy AC: ±0.8% DC: ±0.7% AC: ±0.8% DC: ±0.7%
Resistance (Ω) 600, 6k, 60k, 600k, 6M, 60M (0.1Ω) 600, 6k, 60k, 600k, 6M, 60M (0.1Ω)
Capacitance 6.2nF, 620μF, 62mF (1pF) 6.2nF, 620μF, 62mF (1pF)
Frequency 10Hz to 60kHz (0.001Hz) 10Hz to 60kHz (0.001Hz)
Diode/Continuity Yes Yes
Dimensions/ Weight 6.9x2.4x1.3" (175x60x33.5mm) / 6oz (170g) 6.9x2.4x1.3" (175x60x33.5mm) / 6oz (170g)
PRODUCT DATASHEETPRODUCT DATASHEET
Ordering
MA61 N .......... True RMS 60A AC Clamp Meter+NCV
MA63 N .......... True RMS 60A AC/DC Clamp Meter+NCV
N Indicates products that are available with optional calibration traceable to NIST. Order with -NIST after part number for product plus Calibration Certificate.
Specifications subject to change without notice. Copyright © 2015 FLIR Systems, Inc. All rights reserved including the right of reproduction in whole or in part in any form.
Rev. 6/5/15
MA61 MA63
MA61 UPC Code: 793950370612
MA63 UPC Code: 793950370636
www.extech.com