USER MANUAL
Model ET40B - Continuity Tester
Introduction
Ideal for checking continuity of non-energized
components, fuses, diodes, switches, relays and
wiring. Ideal for automotive, aircraft and home
applications.
Continuity Testing
WARNING: To avoid electric shock, never
measure continuity on circuits that have
voltage on them.
CAUTION: This is not a circuit tester. All
power must be turned OFF before use or
bulb will burn out.
1. Remove the battery compartment nut with
a wrench and insert one AAA battery in
either polarity. Secure the battery
compartment with the nut before use.
2. Remove all power from the circuit to be
tested
3. Perform a self-test by connecting the
alligator clip end of the probe wire to the
metal portion of the ET40B. If functioning
properly, the bulb should illuminate.
4. Attach the alligator clip to one side of the
device and touch the probe tip to the other
side of the device
5. The bulb will light if there is continuity. If
bulb does not light, replace the component.
CAUTION: Do not use this tester for cables
with built-in resistance, such as spark plug
cable and appliance electronic coils.
CAUTION: Use extreme caution when
checking electrical circuits to avoid injury
due to electrical shock. FLIR Systems, Inc.
assumes basic knowledge of electricity on
the part of the user and is not responsible
for any injury or damages due to improper
use of this tester.
Copyright © 2016 FLIR Systems, Inc.
All rights reserved including the right of reproducti on in whole or in part in any form
MANUAL DEL USUARIO
Modelo ET40B - Probador de
Continuidad
Introducción
Ideal para verificar la continuidad de componentes no energizados, fusibles, interruptores, relés y cableado.
Ideal para aplicaciones en automóviles, aeronaves y
hogar.
Pruebas de continuidad
ADVERTENCIA: Para evitar choque eléctrico,
nunca mida continuidad en circuitos con voltaje.
PRECAUCIÓN: Este no es un probador de
circuitos. Se debe apagar toda tensión antes de
usar o se quemará el bulbo.
1. Extraiga la tuerca del compartimiento de la batería
con una llave e inserte una batería AAA en
cualquier polaridad. Fije el compartimiento de la
batería con la tuerca antes de usar.
2. Quite toda la energía del circuito a probar
3. Realice una autocomprobación conectando la
pinza a la porción metálica del equipo ET40B. Si
funciona correctamente, la bombilla debería
encenderse.
4. Conecte la pinza a un lado del dispositivo y toque
la punta de la sonda al otro lado del dispositivo
5. El bulbo se iluminará si hay continuidad. Si el
bulbo no se ilumina, reemplace el componente.
PRECAUCIÓN: No use este probador para cables
con resistencia integrada, tales como cables de
bujías y bobinas de aparatos electrónicos.
PRECAUCIÓN: Extreme sus precauciones al probar
circuitos eléctricos para evitar lesiones debido a
choque eléctrico. FLIR Systems, Inc. supone
conocimientos básicos de electricidad por parte del
usuario y no se hace responsable por cualquier
lesión o daños debido al uso impropio de este
probador.
Copyright © 2016 FLIR Systems, Inc.
Reservados todos los derechos, incluyendo el derecho de reproducción
total o parcial en cualquier medio.
ET40B-en-es-fr_V1.1 11/16
Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com

MANUEL D’UTILISATION
Modèle ET40B - Testeur de
continuité
Introduction
Idéal pour contrôler la continuité de
composants, fusibles, commutateurs, relais et
câblage non alimentés en courant. Idéal pour
des applications automobiles, d’aviation et
domestiques.
Tests de continuité
AVERTISSEMENT : Afin d’éviter tout risque
d’électrocution, ne mesurez jamais la
continuité sur des circuits sous tension.
ATTENTION : Il ne s’agit pas d’un testeur de
circuits. COUPEZ toute alimentation avant
toute utilisation, dans le cas contraire,
l’ampoule se grille.
1. Retirez l'écrou du compartiment à pile à
l'aide d'une clé, puis insérez une pile «
AAA » en respectant la polarité.
Refermez le compartiment à pile à l'aide
de l'écrou avant d’utiliser l’appareil.
2. Coupez toute alimentation du circuit à
tester.
3. Exécutez une vérification automatique en
reliant l'embout de la pince crocodile du
fil de la sonde à la partie métallique de
l'ET40B. Si le dispositif fonctionne
convenablement, l'ampoule devrait
s'allumer.
4. Fixez la pince crocodile sur un côté du
dispositif, puis mettez l’embout de la
sonde en contact avec l’autre côté du
dispositif
5. L’ampoule s’allume en cas de présence
de continuité. Si l’ampoule ne s’allume
pas, remplacez le composant.
ATTENTION : Ne pas utiliser ce testeur pour
des câbles présentant une résistance
intégrée, notamment des câbles de bougie
et des bobines électroniques d’appareils.
ATTENTION : Faites preuve d’une extrême
prudence lorsque vous contrôlez des circuits
électriques afin de prévenir tout risque de
blessures liées à l’électrocution. FLIR
Systems, Inc. suppose que l’utilisateur
possède des connaissances élémentaires en
matière d’électricité. Elle décline en
conséquence toute responsabilité
concernant des blessures et dommages
éventuels résultant d’une utilisation
incorrecte de ce testeur.
Droits d’auteur © 2016 FLIR Systems, Inc.
Tous droits réservés, y compris la reproduction partielle ou totale sous
quelque forme que ce soit
ET40B-en-es-fr_V1.1 11/16
99 Washington Street
Melrose, MA 02176
Phone 781-665-1400
Toll Free 1-800-517-8431
Visit us at www.TestEquipmentDepot.com