User's Guide
Heavy Duty Differential Pressure Manometer
Model 407910
Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176
Specifications
General Specifications
Circuit Custom one-chip LSI microprocessor circuit Display 0.6" (16mm) 2000 count LCD with function indicators Units of Measure mBAR, psi, kg/cm2, mm Hg, inches Hg, meter H2O, inches H2O
Input circuit Differential inputs (P1 and P2) Data Hold Freezes displayed reading Sensor Built-in piezoelectric sensors Zero Adjust Front panel push-button Sample rate 0.8 sec. (approx.) Compatibility Air or non-corrosive and non-ionized gas Auto Power OFF Meter turns off after approx. 10 minutes to conserve energy Data Output RS-232 PC serial interface Ambient conditions 32 to 122oF (0 to 50oC); < 80% RH Battery power 9V alkaline battery Power Consumption 6mA DC (approx.) Dimensions 7.1 x 2.8 x1.3" (180 x 72 x 32 mm) Weight 0.76 lbs (345 g) Accessories Quick-disconnect fittings (2), rubber jacket, and 9V battery
Range Specifications
Range/Units (Max.) Resolution
± 2000 mbar 1 ± 29 psi 0.02 ± 2.040 Kg/cm2 0.001 ± 1500 mm Hg 1 ± 59.05 inches Hg 0.05 ± 20.40 meters H2O 0.01 ± 802 inches H2O 0.5 ± 1.974 atmospheres 0.001
and Atmospheres
Accuracy
± 2% full scale @ 23±5 Note: Accuracy includes linearity,
hysteresis and repeatability effects
o
C
3
Model 407910 - Version 2.0 - March 2005
Meter Description
1. LCD Display – Indicates the measurement data, unit of measure, and user alert symbols as described in this manual
2. Push-buttons:
POWER – Press to turn the meter ON or OFF
HOLD – Press to freeze the displayed reading
ZERO – Press to null the display (with fittings disconnected)
RECORD/RECALL – Press to access the MIN/MAX recording mode as described
later in this manual
UNIT – Press to select the unit of measure
3. 0.16” (4mm) Quick-disconnect fittings (supplied)
4. P1 Input – 0.16” (4mm) accepts quick disconnect connector
5. RS-232 PC interface jack (3.5mm) – For use with data acquisition software/hardware interface kit model 407001
6. P2 input – 0.16” (4mm) accepts quick disconnect connector
7. Rubber protective holster (removable)
8. Battery compartment (on rear) – Remove rubber jacket to access compartment
456
1
7
2
3
8
4
Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176
Model 407910 - Version 2.0 - March 2005
Basic Operation
Meter Power
This device uses a 9V battery for power. If the meter does not switch on when the POWER button is pressed or if the display shows LBT, replace the battery (refer to the Battery Replacement section later in this manual).
In order to conserve battery life, the meter has an automatic power off feature (after 10 minutes). To defeat this feature, access the RECORD mode by pressing the RECORD/RECALL button. In the RECORD mode, the meter will remain on until the user turns it off or until the battery weakens.
Unit of measure
Press the UNIT button to select the unit of measure. This meter offers eight (8) units of measure as listed below, in the specifications chart earlier in this manual, and on the face­plate of the meter.
Units Displayed Symbol
MBAR "m" at bottom of the LCD and "Bar" at the top Kg/cm2 Kg /cm2 mm of Hg mm /Hg m H2O m H2O Atmospheres ATP PSI PSI Inches of Hg in/Hg Inches of H2O inch H2O
Zero Adjust and Offset function
Before use and without fittings attached to the meter, press the ZERO button to calibrate the meter’s circuitry. The display should then indicate zero.
If it is desired to offset the meter’s display, press the ZERO button while taking a measurement. Subsequent readings will be the difference between the current measurement and the measurement that was on the display when the ZERO button was pressed.
Fittings Connection
Connect tubing to the quick-disconnect fittings and then snap the supplied quick­disconnect fitting(s) to the P1, P2 (or both) input port(s). If both inputs are used (differential mode), the meter displays a positive pressure reading if the P1 pressure is greater than P2 and a negative reading if P2 is greater than P1.
5
Model 407910 - Version 2.0 - March 2005
MIN/MAX Record/Recall Mode
The Record/Recall function tracks the maximum and minimum readings for recall at any time.
1. Press the RECORD/RECALL button once. The REC indicator will appear on the display.
2. Press the RECORD/RECALL button again to view the highest (MAX) reading taken since the RECORD/RECALL button was first pressed. The MAX indicator and maximum reading will appear on the display.
3. Press the RECORD/RECALL button again, the MIN indicator and the minimum value will appear on the display.
4. To return to normal operation, press and hold display indicators REC, MAX, and MIN disappear.
RS-232 PC Interface
The meter has a built-in RS-232 serial port for use with the optional PC Interface Data Acquisition Software/Hardware kit Model 407001.
the RECORD/RECALL button until the
6
Model 407910 - Version 2.0 - March 2005
Battery Replacement
When the low battery indicator LBT appears on the display or if the meter does not switch on when the POWER button is pressed, it is necessary to replace the battery.
To replace the battery:
1. Remove the meter's rubber protective jacket by stretching it over the bottom of the meter.
2. Pry open the battery compartment located on the back of the meter using a small coin or screwdriver.
3. Replace the 9V alkaline battery
4. Replace the battery compartment cover and the protective jacket.
Useful Conversions
Useful conversion Factors
From To Multiplier
In of H2O In of Hg 0.07355 In of H2O Cm of Hg 2.54
mm of Hg In of H2O 0.03937
Calibration and Repair Services
Support line (781) 890-7440
Technical support: Extension 200; E-mail: support@extech.com
Repair & Returns: Extension 210; E-mail: repair@extech.com
Product specifications subject to change without notice
For the latest version of this User’s Guide, Software updates, and other
up-to-the-minute product information, visit our website: www.extech.com Extech Instruments Corporation, 285 Bear Hill Rd., Waltham, MA 02451
Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176
Loading...