Extech 407113 Operating Manual

User's Guide
Heavy Duty CFM Thermo-Anemometer Model 407113
3
Introduction
Congratulations on your purchase of the Extech 407113 CFM meter. This handheld meter can display Air Flow (CFM) with Area or Air Velocity with Temperature on a 10,000-count (0 to 9999) dual display LCD. Other functions include MIN/MAX Record/Recall, RS-232 PC interface, and Data Hold. The metal vane sensor offers rugged durability and higher temperature withstand than comparable devices. Careful use of this meter will provide years of reliable service.
Specifications
General Specifications
Display Dual Display Multi-function 10,000-count (0 to 9999) LCD Measurements Air Velocity: m/s, km/h, ft/min, knots, mph;
Air Flow: CMM (m
Temperature: °C and °F Data Hold Freezes displayed reading Sampling rate One (1) reading per second Sensors Air velocity/flow sensor: Metal angled vane arms with low-
friction ball bearing. Temp. Sensor: Precision thermistor MIN/MAX Records/Recalls lowest and highest readings Auto Power OFF Automatic shut off after 15 minutes PC Interface RS-232 Serial Communications (16-bit data stream) Over range indication 1___ appears on the LCD Low battery indication LBT appears on the LCD Power supply 9V Battery (consumption 8.3mA approx.) Operating conditions Meter: 32 to 122 Sensor: 32 to 175
Dimensions / Weight Main instrument: 7.1 x 2.8 x1.3" (180 x 72 x 32mm)
Sensor head: 2.8” (72mm) diameter Weight 0.84 lbs. (381g) for meter and sensor
3
/min) and CFM (ft3/min);
o
F (0 to 50oC); 80% RH max.
o
F (0 to 80oC)
2
Range Specifications
Air Velocity Measurements Range Resolution Accuracy (%rdg)
m/s (meters per second) 0.50 - 35.0 m/s 0.01 m/s<10
± (2% + 0.2m/s)
0.1 m/s >10 km/h (kilometers per hour) 1.8 – 126.0 km/h 0.1 km/h ± (2% + 0.8km/h) ft/min (feet per minute) 100 – 6890 ft/min 1 ft/min ± (2% + 40ft/min) mph (miles per hour) 1.1 – 78.3 mph 0.1 mph ± (2% + 0.4m/h) knots (nautical miles per hour ) 1.0 to 68 knots 0.1 knots ± (2% + 0.4knots) Air Flow Measurements Range Resolution Area CMM (cubic meters per minute) 0-999,900 m3/min 0.001 to 100 0 to 9,999m2 CFM (cubic feet per minute) 0-999,900 ft3/min 0.001 to 100 0 to 9,999ft2
Air Temperature Range Resolution Accuracy 32 to 175oF (0 to 80oC) 0.1o F/C 1.5oF (0.8oC)