WALK TESTING
LS1000R LightSpot 360° Dual Mount PIR installation and operating instructions
1 3
2
warm up
20-50 SEC
SUN.
MIN.
MANUAL OVERRIDE OPERATION
Activate Manual Override Operation
2 SEC
5
SEC
ON
OFF
2 times within 2 seconds
ON
Lamp turn on
when reach Lux
setting level.
DUSK
Hrs
DAWN
Deactivate Manual Override Operation
1
Manual deactivation before dawn
ON
2
Auto deactivation when
OFF
1 time within 1 second
dusk to dawn
10 second
5
SEC
ON
OR
ON
Around
1 SEC
Lamp turn off when
dusk to dawn.
Auto Mode
Only suitably qualified personnel should install this equipment
!!
PACK CONTENTS
x1x1 x1 x1 x2
REQUIRED
No 2
Phillips
4mm
I
5mm
x1 x1 x1 x1 x1 x1
MOUNTING/ INSTALLATION STEPS
Surface Mount
1
2
3mm
(For Euro conduit box
(For ceiling mout
Hole saw size:
Ф75mm - 80mm
M4 x 14mm
installation)
x2
M3 x 20mm
installation)
3
(For cable clamps
230V
M3 x 15mm
installation)
x4
x2 x2
SWITCHABLE LOAD
TECHNICAL SPECIFICATIONS
Detection Range:
Detection Angle:
Power Supply:
Maximum Switchable Load:
Time On Adjustment:
Dusk Level Adjustment:
Operating temperature:
Environment Protection:
Up to 6 metres diameter (3m Radius)
at mounting height of 2.5m
360°
220 ~ 240 VAC / 50 Hz
Max load current 6A
Incandescent / Halogen Max 2000W
Flourescent lamp (magnetic) Max 500W
Flourescent lamp (electronic ballast) Max 400W
Low energy (CFL) Max 120W
LED lamp Max 110W
Fan Max 75W
5 seconds - 15 minutes
Day & night or night only operation
-20 to 40°C
For ceiling mount - IP44
For flush mount - IP44 (at sensor portion only)
- IP20 (ceiling board onwards)
Max 2000W
Max 500W
Max 400W
Max 120W
Max 110W
Max 75W
Auto Mode
Haydock Lane
Haydock
Merseyside
WA11 9UJ
UK
www.ex-or.com
Technical Support
+44 (0)1942 719229
0FF
4
7
Cable entry
capability at
terminal block
1 x 2.5mm²
2 x 1.0mm²
2 x 1.5mm²
60mm
50.8mm
OR
5
8
* Remark: L1 & L2 is relay output
Switch OFF the electricity at the fuse box by
removing the relevant fuse or switching off the circuit
breaker before proceeding with the installation.
IMPORTANT
Connection:
L1L2LN
( See connection diagram )
Connect the mains supply
cable to the terminal block on
the backplate as follows.
L
N
Switched Live
L1
Wiring diagram
Option1
9
‘CLICK’
‘CLICK’
OR
Cut out
here
50.8mm or 60mm
6
NLμL2 L1
‘CLICK’
Brown
Blue
White
Live
Neutral
Earth Green / Yellow
CAUTION:
ij
5mm
Connect the cable from the
lighting load to the terminal block
on the backplate as follows.
Live
L
Neutral
N
Earth Green / Yellow
Relay contact
L1 &
for external load
L2
Option2
N
L
Note: Remove the external link
between L and L2
The device needs
20-50 seconds to
NL
L2 L1
warm up.
μ
Brown
Blue
White
N
L
L1
L2

MOUNTING/ INSTALLATION STEPS
Flush Mount
1 2 3
MOTION SENSOR DETECTION
When mounting
at 2.5m height
230V
3 METRE
0FF
3 METRE 3 METRE
Opening hole
4
75mm~80mm diameter
Cable entry
capability at
terminal block
1 x 2.5mm²
2 x 1.0mm²
2 x 1.5mm²
Ceiling board
thickness
5mm-20mm
Power wire
5
* Remark: L1 & L2 is relay output
Switch OFF the electricity at the fuse box by
removing the relevant fuse or switching off the circuit
breaker before proceeding with the installation.
IMPORTANT
Connection:
L1L2LN
( See connection diagram )
Connect the mains supply
cable to the terminal block on
the backplate as follows.
L
N
Switched Live
L1
Wiring diagram
Option1
6 7 8
‘CLICK’
9
NLμL2 L1
Brown
Blue
White
Live
Neutral
Earth Green / Yellow
Connect the cable from the
lighting load to the terminal block
on the backplate as follows.
Live
L
Neutral
N
Earth Green / Yellow
Relay contact
L1 &
for external load
L2
Option2
N
L
Note: Remove the external link
between L and L2
NL
L2 L1
μ
Brown
Blue
White
Dia. 6 METRE
3 METRE
TOP VIEW
N
L
L1
L2
PERSPECTIVE VIEW
°C
40
30
20
10
40
°C
40
30
20
10
40
2.5 M
°C
40
30
20
10
40
3 METRE 3 METRE
1 M
SIDE VIEW
LENS MASK
REMOVING
Surface Mount
REMOVING
Flush Mount
Ceiling board
The device need
20-50 seconds to
warm up.
‘CLICK’
Lens mask
sticker
TESTING & OPERATION
Adjustment
-Can be adjusted by flat head screwdriver.
Restrict
short
detection
Restrict
long
detection
Restrict
detection
directly
under
sensor
ON-TIME LUX
SEC
5 SEC
15 MIN
15
MIN