Copyright © 2019 Exor International S.p.A. – Verona, Italy Subject to change without notice The information contained in this document is provided for informational purposes only. While efforts were made to verify the accuracy of the information contained in this documentation, it is provided “as is” without warranty of any kind. Third-party brands and names are the property of their respective owners. www.exorint.com
MANUGENJSMART7xxW - Version 1.00 © 2019 EXOR International S.p.A. - Subject to change without notice
2
Table of Contents
Introduction 4
Safety Guide 5
1 Product Overview 6
2 Standards and Approvals 7
3 Technical Specications 9
4 Technical Data 13
4.1 Dimensions 15
4.2 Installation Environment and Procedure 18
4.3 Safety instruction 19
5 Connections 20
5.1 Ethernet Port 20
6 Power Supply, Grounding and Shielding 21
7 Battery 22
8 Special Instruction for Use 24
9 Getting Started 24
10 System Settings 25
11 Unpacking and Packing Instructions 27
MANUGENJSMART7xxW - Version 1.00 © 2019 EXOR International S.p.A. - Subject to change without notice
3

Introduction

The operational guidelines described below is information which relates to the device, installation, transpor­tation, storage, assembly, use and maintenance.
This Operating Instruction describes the main features of the Exor operator panels. The Manual refers to the following models:
JSmart707 Field-ready HMI 7” color TFT, PCAP touchscreen, Ethernet port PoE JSmart710 Field-ready HMI 10.1” color TFT, PCAP touchscreen, Ethernet port PoE JSmart715 Field-ready HMI 15.6” color TFT, PCAP touchscreen, Ethernet port PoE JSmart721 Field-ready HMI 21.5” color TFT, PCAP touchscreen, Ethernet port PoE
MANUGENJSMART7xxW - Version 1.00 © 2019 EXOR International S.p.A. - Subject to change without notice
4

Safety Guide

The manual contains safety standards that must be respected for the personal safety and to avoid damage. Indications of attention are divided into three levels of severity:
DANGER: indicates a failure to observe safety rules and such failure may cause death or serious injuries.
DANGER
!
ATTENTION: indicates a failure to observe safety rules and that deciency may cause damage.
ATTENTION
!
CAUTION: indicates a failure to observe safety rules and that deciency may cause defects to the equipment or inconsistencies.
CAUTION
MANUGENJSMART7xxW - Version 1.00 © 2019 EXOR International S.p.A. - Subject to change without notice
5

1 Product Overview

JSmart700 products are ideal for eld installation in critical areas. High-resolution displays and multitouch
PCAP touchscreen with a robust glass front. Power-over-Ethernet (PoE) for maximum simplicity of connection using standard shielded CAT 5 wiring. Full IP protection with the use of dedicated connectors for the maximum flexibility of installation, from mounting arm to a simple M22 hole. The product includes environment and motion sensors to make this device a true IIoT edge device for Industry 4.0 applications. The JSmart product family has been optimized for use as an embedded browser or as a JMobile HMI device.
Open platform for Linux applications
Performing HTML5-compatible browser with graphic accelerator
JMobile runtime with OPC UA Server and Client
Optional CODESYS V3 PLC for integrated HMI and control applications
Built-in sensors (temperature and acceleration)
MANUGENJSMART7xxW - Version 1.00 © 2019 EXOR International S.p.A. - Subject to change without notice
6

2 Standards and Approvals

The products have been designed for use in an industrial environment in compliance with the 2014/53/EU Directive.
The products have been designed in compliance with:
EN 61000-6-4 EN 61000-6-2 EN 61000-6-3 EN 61000-6-1 ETSI EN 301 489-1 ETSI EN 301 489-17 ETSI EN 300 328 EN 62311 * EN 61010-1 EN 61010-2-201
* Standard radio signal and minimum distance from the body calculated according to EN 62311
Standard radio signal WiFi 2,4GHz Minimum distance form the body (cm)* 2
* The WiFi antenna is positioned behind the black band above the display.
The products are in compliance with the Restrictions on Certain Hazardous Substances (RoHS) Directive 2011/65/EU
In compliance with the above regulations the products are CE marked.
MANUGENJSMART7xxW - Version 1.00 © 2019 EXOR International S.p.A. - Subject to change without notice
7
2 Standards and Approvals
Product Identication
The product may be identied by the indications in the back cover. You will have to know the type of unit you
are using for correct usage of the information contained in the guide. An example of the information reported is shown below:
product model name JSmart707
year/week of production 1920
serial number AA00012P9000000561AA
manufacturer address Exor International S.p.A. Via Monte Fiorino 9
IT-37057 San Giovanni Lupatoto (VR)
Ordering code key
Example: +JS707BB1U5P1
MANUGENJSMART7xxW - Version 1.00 © 2019 EXOR International S.p.A. - Subject to change without notice
8
3 Technical Specications
Touchscreen technology Projected capacitive - Multitouch Back-up battery
3V 7mAh Vanadium-Lithium, rechargeable, not user-replacea
ble, model VL1220.
Flash 4GB (8GB for JSmart715 and JSmart721) RAM 1GB (2GB for JSmart715 and JSmart721) Hardware clock Clock/Calendar with back-up battery Accuracy RTC (at 25°C) <100ppm
Environmental conditions
Operating temperature (surrounding -20 ÷ +55°C (vertical installation) EN 60068-2-14 air temperature)
Storage temperature -30 ÷ +80°C (JSmart707, 710) EN 60068-2-1
-20 ÷ +70°C (JSmart715, 721) EN 60068-2-2 EN 60068-2-14
Operating and storage humidity 5 ÷ 85 % RH not-condensing EN 60068-2-30
Vibrations 5 ÷ 9 Hz, 7 mm
9 ÷ 150 Hz, 1 g
Shock ± 50 g, 11 ms, 3 pulses per axis EN 60068-2-27
Protection class IP67 (requires appropriate connectoris EN 60529
and cables)
EN 60068-2-6
p-p
Electromagnetic Compatibility (EMC)
Radiated disturbance test Class A CISPR 22 CISPR 16-2-3
Electrostatic discharge immunity test 8 kV (air electrostatic discharge) EN 61000-4-2
4 kV (contact electrostatic discharge)
Radiated, radio-frequency, 80 MHz ÷ 1 GHz, 10V/m EN 61000-4-3 electromagnetic eld immunity test 1,4 GHz ÷ 2 GHz, 3 V/m 2 GHz ÷ 2.7 GHz, 1 V/m
Burst immunity test ± 2 KV dc power port EN 61000-4-4 ± 1 KV signal line
Surge immunity test ± 0,5 KV dc power port (line to earth) EN 61000-4-5 ± 0,5 KV dc power port (line to line) ± 1 KV signal line (line to earth)
Immunity to conducted disturbances
inducted by radiofrequency eld 0.15 ÷ 80 MHz, 10V EN 61000-4-6
Power frequency magnetic eld
immunity test Enclosure, 50/60Hz, 30A/m EN 61000-4-8
MANUGENJSMART7xxW - Version 1.00 © 2019 EXOR International S.p.A. - Subject to change without notice