Exor eX710, eX707, eX715, eX721, eX705 Operating Instructions Manual

Exor International S.p.A. MANUGENEX7xx Ver. 2.00
eX700 Series
Operating Instructions
Basic User’s Manual for eX700 Series
Touchscreen Products
2
MANUGENEX7xx Operating Instructions VER 2.00
Copyright © 2017 Exor International S.p.A. – Verona, Italy Subject to change without notice
The information contained in this document is provided for informational purposes only. While e󰀨orts
were made to verify the accuracy of the information contained in this documentation, it is provided “as is” without warranty of any kind. Third-party brands and names are the property of their respective owners. www.exorint.net
3
MANUGENEX7xx Operating Instructions VER 2.00
Table of Contents
Table of Contents
Introduction 4 Safety Guide 5
1 Product Overview 6 2 Standards and Approvals 7 3 Technical Specications 9 4 Technical Data 11
4.1 Dimensions 14
4.2 Installation Environment 16
4.3 Safety instruction 17
4.4 Installation Procedure 17 5 Connections 18
5.1 Serial Port 20
5.2 Ethernet Port 20
5.3 Optional plugin module 21
6 Power Supply, Grounding and Shielding 23 7 Battery 24 8 Special Instruction for Use 25 9 Getting Started 25 10 System Settings 26
11 Unpacking and Packing Instructions 28
4
MANUGENEX7xx Operating Instructions VER 2.00
Introduction
The operational guidelines described below is information which relates to the device, installation, tran­sportation, storage, assembly, use and maintenance.
This Operating Instruction describes the main features of the Exor operator panels. The Manual refers to the following models:
eX705 Operator interface with TFT color 5” widescreen display multitouch projected capacitive touchscreen eX707 Operator interface with TFT color 7” widescreen display multitouch projected capacitive touchscreen eX710 Operator interface with TFT color 10.1” widescreen display multitouch projected capacitive touchscreen eX715 Operator interface with TFT color 15.6” widescreen display multitouch projected capacitive touchscreen eX721 Operator interface with TFT color 21.5” widescreen display multitouch projected capacitive touchscreen
Introduction
5
MANUGENEX7xx Operating Instructions VER 2.00
Safety Guide
The manual contains safety standards that must be respected for the personal safety and to avoid damage. Indications of attention are divided into three levels of severity:
DANGER: indicates a failure to observe safety rules and such failure may cause death or serious injuries.
ATTENTION: indicates a failure to observe safety rules and that deciency may cause damage.
CAUTION: indicates a failure to observe safety rules and that deciency may cause defects to the
equipment or inconsistencies.
CAUTION
ATTENTION
DANGER
!
!
Safety Guide
6
MANUGENEX7xx Operating Instructions VER 2.00
1 Product Overview
eX Series 700 HMI products combine state-of-the-art connectivity features and top performance in a great design. Products have been designed as IoT edge devices with the combination of a powerful controller with networking capability (up to 3 Ethernet networks) and outstanding communication options including client/server OPC UA. They are the ideal choice for all demanding IoT edge applications in factory, marine and building automation. The glass projected capacitive touchscreen and the brilliant displays with size up to 21.5” and
resolution up to 1920x1080 guarantee great optical performance; with the support of multitouch
gesture programming they can create the most natural human interfaces.
eX Series 700 products have been designed to run the JMobile software for powerful HMI applications.
Gateway function with OPC UA Server and Client.
Secure connectivity with JMcloud and full network separation.
Powerful browser wih industry standard Web engines.
Optional CODESYS V3 PLC runtime with choice of major I/O protocols.
Optional plug-in modules for eldbus systems, I/O and controllers.
Product Overview
7
MANUGENEX7xx Operating Instructions VER 2.00
2 Standards and Approvals
The products have been designed for use in an industrial environment in compliance with the 2014/30/ EU EMC Directive.
The products have been designed in compliance with: EN 61000-6-4 CISPR 22 Class A CISPR 16-2-3
EN 61000-6-2 EN 61000-4-2 EN 61000-4-3 EN 61000-4-4 EN 61000-4-5 EN 61000-4-6 EN 61000-4-8 EN 61000-4-11
EN 61000-4-29
EN60945
The installation of these devices into the residential, commercial and light-industrial environments is allo­wed only in the case that special in measures are taken in order to ensure conformity to EN 61000-6-3.
The products are in compliance with the Restrictions on Certain Hazardous Substances (RoHS) Directive
2002/95/EC
In compliance with the above regulations the products are CE marked.
Standards and Approvals
8
MANUGENEX7xx Operating Instructions VER 2.00
Standards and Approvals
Product Identication
The product may be identied through a plate attached to the rear cover. You will have to know the type of
unit you are using for correct usage of the information contained in the guide.
An example of this plate is shown in the gure below:
Note: the eX710 label is used as an example for eX700 Series
product model name eX710
product part number EX710U5P1
year/week of production 1706
serial number AA00011FV000000561AA
version id of the product 120201A01000000
manufacturer address Exor International S.p.A.
Via Monte Fiorino 9
IT-37057 San Giovanni Lupatoto (VR)
9
MANUGENEX7xx Operating Instructions VER 2.00
Standards and Approvals
Electromagnetic Compatibility (EMC)
Radiated disturbance test Class A CISPR 22 CISPR 16-2-3
Electrostatic discharge immunity test 8 kV (air electrostatic discharge) EN 61000-4-2
4 kV (contact electrostatic discharge)
Radiated, radio-frequency, 80 MHz ÷ 1 GHz, 10V/m EN 61000-4-3 electromagnetic eld immunity test 1,4 GHz ÷ 2 GHz, 3 V/m 2 GHz ÷ 2.7 GHz, 1 V/m
Burst immunity test ± 2 KV dc power port EN 61000-4-4 ± 1 KV signal line
Surge immunity test ± 0,5 KV dc power port (line to earth) EN 61000-4-5 ± 0,5 KV dc power port (line to line) ± 1 KV signal line (line to earth)
Immunity to conducted disturbances
inducted by radiofrequency eld 0.15 ÷ 80 MHz, 10V EN 61000-4-6
Power frequency magnetic eld
immunity test Enclosure, 50/60Hz, 30A/m EN 61000-4-8
Environmental conditions
Operating temperature (surrounding -20 ÷ +60°C (vertical installation) EN 60068-2-14 air temperature) Plug-in modules and USB devices
may limit max temperature to +50°C
Storage temperature -20 ÷ +70°C EN 60068-2-1 EN 60068-2-2 EN 60068-2-14
Operating and storage humidity 5 ÷ 85 % RH not-condensing EN 60068-2-30
Vibrations 5 ÷ 9 Hz, 7 mm
p-p
EN 60068-2-6
9 ÷ 150 Hz, 1 g
Shock ± 50 g, 11 ms, 3 pulses per axis EN 60068-2-27
Protection class Front panel IP66, Rear IP20 EN 60529
3 Technical Specications
Touchscreen technology Projected capacitive Back-up battery
3V 50mAh Lithium, rechargeable, not user-replaceable,
model VL2330.
Fuse Automatic Serial Port
RS-232, RS-485, RS-422 software congurable
Flash 4GB for eX705, eX707, eX710, 8GB for eX715, eX721 RAM 512MB for eX705, 1GB for eX707, eX710, 2GB for
eX715, eX721
Hardware clock Clock/Calendar with back-up battery Accuracy RTC (at 25°C) <100ppm
10
MANUGENEX7xx Operating Instructions VER 2.00
Voltage dips, short interruptions and voltage variations immunity test Port: AC mains; Level:
0% duration: 1 cycle and 250 cycles (50Hz); 1 cycle and 300 cycles (60Hz); 40% duration: 10 cycles (50Hz); 12 cycles (60Hz); 70% duration: 25 cycles (50Hz); 30 cycles (60Hz);
Phase: 0°-180°
Test executed on the 230Vac side of the Exor International S.p.A. Power Supply EN 61000-4-11
Port: DC mains; Level:
0% duration: 10ms 20 spaces by 1s
Test executed on the 24Vdc of the EUT EN 61000-4-29
Durability information
Backlight service life 40000 Hrs. or more (LED type) (Time of continuos operation until the brightness of the
backlight reaches 50% of the rated value when the sorrounding air temperature is 25°C) - see Note 1
Note 1: Extended use in environments where the surrounding air temperature is 40°C or higher may degrade backlight quality/reliability/durability.
11
MANUGENEX7xx Operating Instructions VER 2.00
4 Technical Data
Technical Data
Model eX705 eX707
Display / Backlight TFT Color / LED TFT Color / LED
Colors 64K 16M
Resolution 800X480 800X480
Diagonal (inches) 5” widescreen 7” widescreen
Dimming yes yes
Flash 4GB 4GB
SD card slot yes yes
RAM 512MB 1GB
Serial Port
RS-232,RS-485, RS-422
software congurable
RS-232,RS-485, RS-422
software congurable
Ethernet port 2 10/100Mb 2 10/100Mb, 1 10/100/1000Mb
USB port
1 Host interface version 2.0
max. 500mA
2 Host interface version 2.0
max. 500mA
Expansion slot 1 Optional Plugin 2 Optional Plugin
Battery rechargeable rechargeable
Real Time Clock yes yes
Voltage
24Vdc (
*) 24Vdc (*)
Current rating (at 24VDC) 0.6A 0.7A
Weight 1 Kg 1.3 Kg
(
*) 10-32Vdc
For applications requiring compliance with EN 61131-2 and specically in reference to 10 ms voltage dips, the
power supply range voltage is 18-32Vdc.
12
MANUGENEX7xx Operating Instructions VER 2.00
Technical Data
Model eX710 eX715
Display / Backlight TFT Color / LED TFT Color / LED
Colors 16M 16M
Resolution 1280X800 1366X768
Diagonal (inches) 10.1” widescreen 15.6” widescreen
Dimming yes yes
Flash 4GB 8GB
SD card slot yes yes
RAM 1GB 2GB
Serial Port
RS-232,RS-485, RS-422
software congurable
RS-232,RS-485, RS-422
software congurable
Ethernet port 2 10/100Mb, 1 10/100/1000Mb 2 10/100Mb, 1 10/100/1000Mb
USB port
2 Host interface version 2.0
max. 500mA
2 Host interface version 2.0
max. 500mA
Expansion slot 2 Optional Plugin 2 Optional Plugin
Battery rechargeable rechargeable
Real Time Clock yes yes
Voltage
24Vdc (
*) 24Vdc (*)
Current rating (at 24VDC) 1.00A 1.20A
Weight 1.7 Kg 4.1 Kg
(
*) 10-32Vdc
For applications requiring compliance with EN 61131-2 and specically in reference to 10 ms voltage dips, the
power supply range voltage is 18-32Vdc.
13
MANUGENEX7xx Operating Instructions VER 2.00
Model eX721
Display / Backlight TFT Color / LED
Colors 16M
Resolution 1920X1080
Diagonal (inches) 21.5” widescreen
Dimming yes
Flash 8GB
SD card slot yes
RAM 2GB
Serial Port
RS-232,RS-485, RS-422
software congurable
Ethernet port
2 10/100Mb with integrated
switch, 1 10/100/1000Mb
USB port
2 Host interface version 2.0
max. 500mA
Expansion slot 2 Optional Plugin
Battery rechargeable
Real Time Clock yes
Voltage
24Vdc (
*)
Current rating (at 24VDC) 1.70A
Weight 6.1 Kg
(
*) 10-32Vdc
For applications requiring compliance with EN 61131-2 and specically in reference to 10 ms voltage dips, the
power supply range voltage is 18-32Vdc.
Technical Data
14
MANUGENEX7xx Operating Instructions VER 2.00
4.1 Dimensions
Technical Data
Cut out
MODEL A B C D E F
eX705 147mm/5.78” 107mm/4.21” 136mm/5.35” 96mm/3.78” 56mm/2.40” 8mm/0.31”
15
MANUGENEX7xx Operating Instructions VER 2.00
Technical Data
Cut out
MODEL A B C D E F
eX707 187mm/7.36” 147mm/5.79” 176mm/6.90” 136mm/5.35” 47mm/1.85” 8mm/0.31”
eX710 282mm/11.10” 197mm/7.80” 271mm/10.67” 186mm/7.32” 56mm/2.20” 8mm/0.31”
eX715 422mm/16.60” 267mm/10.50” 411mm/16.18” 256mm/10.00” 56mm/2.20” 8mm/0.31”
eX721 552mm/21.73” 347mm/13.66” 541mm/21.30” 336mm/13.22” 56mm/2.20” 8mm/0.31”
16
MANUGENEX7xx Operating Instructions VER 2.00
4.2 Installation Environment
Avoid prolonged exposition to direct sunlight to avoid the risk of overheating the device.
The equipment is not intended for installation in contact with corrosive chemical compounds. Check the
resistance of the front panel to a specic compound before installation.
Do not use tools of any kind (screwdrivers, etc.) to operate the touch screen of the panel.
In order to meet the front panel protection classications, proper installation procedure must be followed:
the borders of the cutout must be at
screw up each xing screw until the bezel corner get in contact with the panel.
the cutout for the panel must be of the dimensions indicated in this manual.
The IP66 is guaranteed only if:
max deviation from the plane surface to the cut-out: O0.5mm
thickness of the case where is mounted the equipment: from 1,5mm to 6mm
max surface roughness where the gasket is applied: O120 um
A. eX7xx B. Installation cut-out
Technical Data
17
MANUGENEX7xx Operating Instructions VER 2.00
4.4 Installation Procedure
Place the xing brackets contained in the xing kit as shown in gure
Technical Data
4.3 Safety instruction
For all installation notes, please refer to the Installation Guide provided with the product.
!
CAUTION
Tightening torque: 130Ncm or screw each xing screw until the bezel corner gets in contact with
the panel.
18
MANUGENEX7xx Operating Instructions VER 2.00
5 Connections
1. USB Port
2. Power Supply
3. Serial port
4. Ethernet Port 0 (10/100Mb)
5. Ethernet Port 1 (10/100Mb)
6. Expansion slot for Plugin module
7. SD Card Slot
Fig. 5.1
Connections
eX705
19
MANUGENEX7xx Operating Instructions VER 2.00
1. USB port
2. Ethernet port 2 (10/100Mb)
3. Ethernet port 1 (10/100Mb)
4. Serial Port
5. Ethernet port 0 (10/100/1000Mb)
6. Power Supply
7. 2x Expansion slot for Plugin module
8. SD Card Slot
Fig. 5.2
Connections
eX707, eX710, eX715, eX721
20
MANUGENEX7xx Operating Instructions VER 2.00
5.1 Serial Port
The serial port is used to communicate with the PLC or with another type of controller.
Di󰀨erent electrical standards are available for the signals in the PLC port connector: RS-232, RS-422,
RS-485.
The serial port is software programmable. Make sure you select the appropriate interface in the pro­gramming software.
The communication cable must be chosen for the type of device being connected.
Connections
SERIAL PORT
To operate in RS-485 pins 1-2 and 3-4 must be con­nected externally.
Pin Description
1 CHB-
2 CHA-
3 CHB+
4 CHA+
5 +5V output
6 GND
7
8 SHIELD
5.2 Ethernet Port
1 8
Yellow OFF: Valid link has NOT been detected ON: Valid link has been detected
Green ON: No activity BLINKING: Activity
The Ethernet port have two status indicators. Please see description in gure.
Pin Description
1 RX
2 TX
3 CTS
4 RTS
5 +5V output
6 GND
7
8 SHIELD
RS-232 RS-422, RS-485
21
MANUGENEX7xx Operating Instructions VER 2.00
5.3 Optional plugin module
eX Series 700 panels have several optional plugin module, multiple modules congurations are possible.
Slot#2 and Slot#4 are available only if plugin module has the “bus extension connector”.
Each slot carries three communication channels:
1 serial interface
1 CAN interface
1 SPI interface
Note: It is not possible to stack two modules that are using the same type of interface.
22
MANUGENEX7xx Operating Instructions VER 2.00
Max modules refers to max number of modules can be plugged into the HMI (all slots),
If you are planning to use PLCM03 and PLCM04 (additional serial ports) you will obtain following “COM
- Slot#” association:
a module plugged in Slot#1 or into Slot#2 will be COM2,
a module plugged in Slot#3 or into Slot#4 will be COM3.
If you are planning to use two PLCM01 (CAN interface) you will obtain following Slot# association:
a module plugged in Slot#1 or into Slot#2 will be the CanPort 0,
a module plugged in Slot#3 or into Slot#4 will be the CanPort 1.
Below you can nd relation between modules and max number of modules that can be used into eX
series 700 panels, based on their Interface Type:
Module Application Max Modules Interface Type Bus Extension
connector
PLCM01 CAN 2 CAN Y
PLCM01-NE CAN 2 CAN N
PLCM02 KNX 1 Serial N
PLCM03 Serial RS232 2 Serial Y
PLCM04 Serial RS485 2 Serial Y
PLCM05 CODESYS License 1 Y
PLCM06 Probus DP 1 SPI N
PLIO03 Multifunction I/O 1 SPI N
PLIO04 Multifunction I/O 1 SPI N
PLIO06 Compact I/O 2 SPI N
23
MANUGENEX7xx Operating Instructions VER 2.00
6 Power Supply, Grounding and Shielding
The power supply terminal block is shown in the gure below.
Note: Ensure that the power supply has enough power capacity for the operation of the equipment.
The unit must always be grounded to earth with 1,5mmq wire size minimum. Grounding helps limit the
e󰀨ects of noise due to electromagnetic interference on the control system.
Earth connection will have to be done using either the screw or the faston terminal located near the power supply terminal block. A label helps identify the ground connection. Also connect to ground the terminal 3 on the power supply terminal block.
The power supply circuit may be oating or grounded. In the latter case, connect to ground the power source common as shown in gure (see below) with a dashed line. When using the oating power scheme, note that the panes internally connects the power common to
ground with a 1M resistor in parallel with a 4,7nF capacitor. The power supply must have double or reinforced insulation. The suggested wiring for the power supply is shown below.
Power Supply, Grounding and Shielding
Fig. 6.2
All the electronic devices in the control system must be properly grounded. Grounding must be performed according to applicable regulations.
Fig. 6.1
3 conductor 1,5mmq wire size minimum, minimum temperature conductor rating 105°C.
24
MANUGENEX7xx Operating Instructions VER 2.00
7 Battery
These devices are equipped with rechargeable Lithium battery, not user-replaceable. The following information is maintained by the battery:
hardware real-time clock (date and time)
Charge:
At rst installation must be charged for 48 hours.
When the battery is fully charged, it ensures a period of 3 months of data back-up at 25°C.
Battery
ATTENTION
Dispose of batteries according to local regulations.
!
Battery
Battery
Fig. 7.1: eX705
Fig. 7.2: eX707, eX710, eX715,
eX721
25
MANUGENEX7xx Operating Instructions VER 2.00
8 Special Instruction for Use
- Install the HMI device according to the accompanying installation instructions.
- Ground the HMI device according to the accompanying installation instructions.
- Only qualied personnel may install the HMI device or repair it.
- Ensure that the aeration holes are not covered.
- Care shall be taken not to allow layers of dust to form on the faceplate of the HMI device in a way that might cause the accumulation of static charges. Keep the faceplate of the HMI device clean: the equipment must be cleaned only with a soft cloth and neutral soap product. Do not use solvents.
- This device should not be used for purposes and methods other than indicated in this document and in the documentation accompanying the product.
Cleaning Faceplates / Getting Started
9 Getting Started
eX Series 700 HMI products delivery conguration is based on a loader. Use the services of the
loader to install applications on the device such as JMobile runtime or browsers. JMobile Studio version V2.6 or higher is required. JMo¬bile Studio is a software tool that must be properly installed on a computer running Microsoft Windows.
There are two options to transfer a JMobile application project to a HMI device: Ethernet Connect the HMI device to the computer with an Ethernet network. In JMobile Studio select the command Run/Download to target. You may have to ensure that the proper
rewall policy has been congured in the computer to allow JMobile Studio to access
the network. USB Create an Update Package using JMobile Studio and copy it to a USB Flash drive.
26
MANUGENEX7xx Operating Instructions VER 2.00
10 System Settings
System Settings
eX Series 700 HMI products have a system settings interface to allow conguration of system options.
The user interface of System Settings is based on HTML pages accessible from the HMI screen or remotely using a Web browser Chrome v44 or higher using port 443. To connect enter the address
https://IP/machine_cong where IP is the IP address of the HMI device. Default username is “admin”,
default password is “admin”. Use navigation menu on the left side of the screen to browse through the available options.
The active item of menu is highlighted on the left side of the screen. The right side shows related information and settings. Depending on the size of the HMI screen, both menu and content of selected item may be shown on screen at the same time or not.
System Settings has two modes of operation:
User Mode JMobile runtime is running or the HMI device is in “factory default” status. System Mode JMobile runtime is not running or the HMI device has a software failure.
System Mode includes all options available in User Mode and additionally includes commands dedicated to system upgrade and recovery not available when running in User Mode.
Activation of System Settings in User Mode:
Factory default status Press “System Setting” button on the HMI screen JMobile runtime running Recall context menu and select “System Settings”. To recall the context menu click and hold any unused area of the touchscreen for a few seconds. Default hold time is 2 seconds.
27
MANUGENEX7xx Operating Instructions VER 2.00
System Settings
Activation of Systems Settings in System Mode:
Normal operation If JMobile runtime is not running: Press “System Setting” button on the device screen to recall System Settings in User Mode. Select
“Restart” -> “Cong OS” to reboot in System Mode.
If JMobile runtime is running: recall context menu and select “System Settings”. To recall the context menu click and hold any unused area of the touchscreen for a few seconds. Default hold time is 2 seconds to enter in System Settings in User Mode. Select
“Restart” -> “Cong OS” to reboot in System Mode.
Recovery operation If device is not responsive, use the so-called “tap-tap” procedure. This procedure consists in tapping the surface of the touchscreen during the device power-up phase. Tapping frequency must be high. You have to start tapping the touchscreen as soon as power has been applied to the device. When the sequence has been recognized, the system shows the message: “TAP-TAP DETECTED”. At this point release touch to boot in User Mode without running JMobile runtime or press and hold few seconds (selecting so “RESTART: CONFIG OS”) to boot in System Mode.
System Settings includes options for basic settings of the device:
Language Congure language used for System Setting menu only. System Show information about platform, status and timers (like System on
time, backlight on time).
Logs Enable persistent log for BSP and allows exporting it. Date & Time Change the device date and time, including time zone and NTP
Server
Network Congure IP Address of Ethernet interface and the other network
settings like DNS, Gateway, DHCP, Hostname, routing and bridging. Services Enable/disable services. Examples of services are: OpenSSH server, Bridge, Cloud, Router, SNMP and logging.
Management Update of BSP components (Main OS, Cong OS, Boot loader,
XLoader), check for partitions consistence, update of splash screen, information about usage and size of partitions. The update of Main OS is available only in System Mode, the update
of Cong OS is only in User Mode. Display Adjust display brightness, congure automatic backlight turno󰀨 and select HMI orientation (90°, 180°, 270° and 360°).
Restart Restart the device. “Main OS” option restarts the device in User
Mode, “Cong OS” option restarts the device in System Mode
showing System Settings.
Authentication Congure password for administrator (“admin”) and for the standard
user (“user”). Administrator has full access to System Settings (updates of BSP and other system components). Standard user has some limitations.
Note: Additional informations on System Settings are available in dedicated manual.
28
MANUGENEX7xx Operating Instructions VER 2.00
11 Unpacking and Packing Instructions
Unpacking and Packing Instructions
to repack the unit, please follow the instructions backwards.
Fig. 11.1: eX705, eX707, eX710
Fig. 11.2: eX715, eX721
Loading...