Exor eTOP-MON Series, eTOP-MON 1205T, eTOP-MON 1500T, eTOP-MON 1700T, eTOP-MON 1900T User Manual

...
EXOR International
www.exorint.net
Industrial Computing Solutions
eTOP-MON eTOP-MON 1200T/1205T/1500T/1700T/1900T
User Manual
Copyright © 2014 EXOR International S.p.A. All Rights Reserved.
ii
Content
CONTENTS
Preface
Copyright ............................................................................................. iv
Disclaimer .............................................................................................. iv
Acknowledgements ............................................................................... iv
Regulatory Compliance Statements ........................................................ iv
Declaration of Conformity ...................................................................... iv
RoHS Compliance ................................................................................... v
Warranty and RMA ................................................................................ vi
Safety Information ................................................................................ viii
Installation Recommendations ...............................................................viii
Safety Precautions .................................................................................. ix
Technical Support and Assistance ............................................................ x
Conventions Used in this Manual ............................................................ x
Global Service Contact Information ........................................................ xi
Package Contents .................................................................................xiii
Ordering Information .............................................................................xv
Chapter 1: Product Introduction
Overview - eTOP-MON 1200T/1205T ...................................................... 1
Key Features ........................................................................................... 1
Overview - eTOP-MON 1500T .................................................................2
Key Features ........................................................................................... 2
Overview - eTOP-MON 1700T .................................................................3
Key Features ........................................................................................... 3
Overview - eTOP-MON 1900T .................................................................4
Key Features ........................................................................................... 4
Specifications .......................................................................................... 5
eTOP-MON 1200T ...............................................................................5
Specifications .......................................................................................... 6
eTOP-MON 1205T ...............................................................................6
Specifications .......................................................................................... 7
eTOP-MON 1500T ...............................................................................7
Specifications .......................................................................................... 8
eTOP-MON 1700T ...............................................................................8
Specifications .......................................................................................... 9
eTOP-MON 1900T ...............................................................................9
Knowing Your APPD Series ...................................................................10
Front Top View of eTOP-MON 1200T/1205T ...................................... 10
Front Top View of eTOP-MON 1500T .................................................10
Front Top View of eTOP-MON 1700T .................................................10
Front Top View of eTOP-MON 1900T .................................................10
Front Top View in Detail ..................................................................... 11
Rear Bottom View of eTOP-MON 1200T/1205T ................................. 12
Rear Bottom View of eTOP-MON 1500T ............................................12
Rear Bottom View of eTOP-MON 1700T ............................................12
Rear Bottom View of eTOP-MON 1900T ............................................12
Rear Bottom View in Detail ................................................................ 13
Rear View of eTOP-MON 1200T/1205T ..............................................14
Rear View of eTOP-MON 1500T ........................................................15
Rear View of eTOP-MON 1700T ........................................................16
Rear View of eTOP-MON 1900T ........................................................17
Mechanical Dimensions .........................................................................18
eTOP-MON 1200T/1205T .................................................................. 18
Copyright © 2014 EXOR International S.p.A. All Rights Reserved.
iii
Content
eTOP-MON 1500T .............................................................................19
eTOP-MON 1700T .............................................................................20
eTOP-MON 1900T .............................................................................21
Chapter 2: Connector Pin Definitions
External I/O Interfaces ........................................................................... 22
USB Port ............................................................................................ 22
COM Port .......................................................................................... 22
DVI Port (DVI-D) .................................................................................23
VGA Port ........................................................................................... 23
12 – 24V DC Input ............................................................................24
Chapter 3: System Setup
Panel Mounting .................................................................................... 25
Installing the Power Adapter Bracket .....................................................28
Chapter 4: Adjusting the Display
OSD Menu Functions ............................................................................ 33
Chapter 5: Touch Driver Settings...........................49
Appendix A: Power Consumption.........................50
Appendix B: Extended Display Identification
Data Timing Support..............................................51
Copyright © 2014 EXOR International S.p.A. All Rights Reserved.
iv
Preface
PREFACE
Copyright
This publication, including all photographs, illustrations and software, is protected under international copyright laws, with all rights reserved. No part of this manual may be reproduced, copied, translated or transmitted in any form or by any means without the prior written consent from EXOR International S.p.A.
Disclaimer
The information in this document is subject to change without prior notice and does not represent commitment from EXOR International S.p.A. However, users may update their knowledge of any product in use by constantly checking its manual posted on our website: http://www.exorint.it. EXOR shall not be liable for direct, indirect, special, incidental, or consequential damages arising out of the use of any product, nor for any infringements upon the rights of third parties, which may result from such use. Any implied warranties of merchantability or fitness for any particular purpose is also disclaimed.
Acknowledgements
eTOP-MON 1200T/1205T/1500T/1700T/1900T is a trademark of EXOR International S.p.A. All other product names mentioned herein are registered trademarks of their respective owners.
Regulatory Compliance Statements
This section describes how to keep the system CE compliant.
Declaration of Conformity
CE
The product(s) described in this manual complies with all applicable European Union (CE) directives if it has a CE marking. For computer systems to remain CE compliant, only CE-compliant parts may be used. Maintaining CE compliance also requires proper cable and cabling techniques.
Copyright © 2014 EXOR International S.p.A. All Rights Reserved.
v
Preface
RoHS Compliance
EXOR RoHS Environmental Policy and Status Update
This publication, including all photographs, illustrations and software, is protected under international copyright
laws, with all rights reserved. No part of this manual may be reproduced, copied, translated or transmitted in any form or by any means without the prior written consent from EXOR International S.p.A.
RoHS restricts the use of Lead (Pb) < 0.1% or 1,000ppm, Mercury (Hg) < 0.1% or 1,000ppm, Cadmium (Cd) < 0.01% or 100ppm, Hexavalent Chromium (Cr6+) < 0.1% or 1,000ppm, Polybrominated biphenyls (PBB) < 0.1% or 1,000ppm, and Polybrominated diphenyl Ethers (PBDE) < 0.1% or 1,000ppm.
In order to meet the RoHS compliant directives, EXOR has established an engineering and manufacturing task force to implement the introduction of green products. The task force will ensure that we follow the standard EXOR development procedure and that all the new RoHS components and new manufacturing processes maintain the highest industry quality levels for which EXOR are renowned.
The model selection criteria will be based on market demand. Vendors and suppliers will ensure that all designed components will be RoHS compliant.
All new product models launched after January 2006 will be RoHS compliant. They will use the usual EXOR naming convention.
Copyright © 2014 EXOR International S.p.A. All Rights Reserved.
vi
Preface
Warranty and RMA
EXOR Warranty Period
EXOR manufactures products that are new or equivalent to new in accordance with industry standard. EXOR warrants that products will be free from defect in material and workmanship for 2 years, beginning on the date of invoice by EXOR. HCP series products (Blade Server) which are manufactured by EXOR are covered by a three year warranty period.
NEXCOM Return Merchandise Authorization (RMA)
▪ Customers shall enclose the “EXOR RMA Service Form” with the returned
packages.
▪ Customers must collect all the information about the problems
encountered and note anything abnormal or, print out any on-screen messages, and describe the problems on the “EXOR RMA Service Form” for the RMA number apply process.
▪ Customers can send back the faulty products with or without accessories
(manuals, cable, etc.) and any components from the card, such as CPU and RAM. If the components were suspected as part of the problems, please note clearly which components are included. Otherwise, EXOR is not responsible for the devices/parts.
▪ Customers are responsible for the safe packaging of defective products,
making sure it is durable enough to be resistant against further damage and deterioration during transportation. In case of damages occurred during transportation, the repair is treated as “Out of Warranty.”
▪ Any products returned by EXOR to other locations besides the customers’
site will bear an extra charge and will be billed to the customer.
Repair Service Charges for Out-of-Warranty Products
EXOR will charge for out-of-warranty products in two categories, one is basic diagnostic fee and another is component (product) fee.
Repair Service Charges for Out-of-Warranty Products
EXOR will charge for out-of-warranty products in two categories, one is basic diagnostic fee and another is component (product) fee.
System Level
▪ Component fee: EXOR will only charge for main components such as
SMD chip, BGA chip, etc. Passive components will be repaired for free, ex: resistor, capacitor.
▪ Items will be replaced with EXOR products if the original one cannot be
repaired. Ex: motherboard, power supply, etc.
▪ Replace with 3rd party products if needed.
▪ If RMA goods can not be repaired, EXOR will return it to the customer
without any charge.
Board Level
▪ Component fee: EXOR will only charge for main components, such as
SMD chip, BGA chip, etc. Passive components will be repaired for free, ex: resistors, capacitors.
▪ If RMA goods can not be repaired, EXOR will return it to the customer
without any charge.
Copyright © 2014 EXOR International S.p.A. All Rights Reserved.
vii
Preface
Warnings
Read and adhere to all warnings, cautions, and notices in this guide and the documentation supplied with the chassis, power supply, and accessory modules. If the instructions for the chassis and power supply are inconsistent with these instructions or the instructions for accessory modules, contact the supplier to find out how you can ensure that your computer meets safety and regulatory requirements.
Cautions
Electrostatic discharge (ESD) can damage system components. Do the described procedures only at an ESD workstation. If no such station is available, you can provide some ESD protection by wearing an antistatic wrist strap and attaching it to a metal part of the computer chassis.
Copyright © 2014 EXOR International S.p.A. All Rights Reserved.
viii
Preface
Installation Recommendations
Ensure you have a stable, clean working environment. Dust and dirt can get into components and cause a malfunction. Use containers to keep small components separated.
Adequate lighting and proper tools can prevent you from accidentally damaging the internal components. Most of the procedures that follow require only a few simple tools, including the following:
▪ A Philips screwdriver
▪ A flat-tipped screwdriver
▪ A grounding strap
▪ An anti-static pad
Using your fingers can disconnect most of the connections. It is recommended that you do not use needle-nose pliers to disconnect connections as these can damage the soft metal or plastic parts of the connectors.
Safety Information
Before installing and using the device, note the following precautions:
▪ Read all instructions carefully.
▪ Do not place the unit on an unstable surface, cart, or stand.
▪ Follow all warnings and cautions in this manual.
▪ When replacing parts, ensure that your service technician uses parts
specified by the manufacturer.
▪ Avoid using the system near water, in direct sunlight, or near a heating
device.
▪ The load of the system unit does not solely rely for support from the
rackmounts located on the sides. Firm support from the bottom is highly necessary in order to provide balance stability.
Copyright © 2014 EXOR International S.p.A. All Rights Reserved.
ix
Preface
Safety Precautions
1. Read these safety instructions carefully.
2. Keep this User Manual for later reference.
3. Disconnect this equipment from any AC outlet before cleaning. Use a
damp cloth. Do not use liquid or spray detergents for cleaning.
4. For plug-in equipment, the power outlet socket must be located near the
equipment and must be easily accessible.
5. Keep this equipment away from humidity.
6. Put this equipment on a stable surface during installation. Dropping it or
letting it fall may cause damage.
7. The openings on the enclosure are for air convection to protect the
equipment from overheating. DO NOT COVER THE OPENINGS.
8. Make sure the voltage of the power source is correct before connecting
the equipment to the power outlet.
9. Place the power cord in a way so that people will not step on it. Do not
place anything on top of the power cord. Use a power cord that has been approved for use with the product and that it matches the voltage and current marked on the product’s electrical range label. The voltage and current rating of the cord must be greater than the voltage and current rating marked on the product.
10. All cautions and warnings on the equipment should be noted.
11. If the equipment is not used for a long time, disconnect it from the power source to avoid damage by transient overvoltage.
12. Never pour any liquid into an opening. This may cause fire or electrical shock.
13. Never open the equipment. For safety reasons, the equipment should be opened only by qualified service personnel.
14. If one of the following situations arises, get the equipment checked by service personnel:
a. The power cord or plug is damaged. b. Liquid has penetrated into the equipment. c. The equipment has been exposed to moisture. d. The equipment does not work well, or you cannot get it to work
according to the user’s manual. e. The equipment has been dropped and damaged. f. The equipment has obvious signs of breakage.
15. Do not place heavy objects on the equipment.
16. The unit uses a three-wire ground cable which is equipped with a third pin to ground the unit and prevent electric shock. Do not defeat the purpose of this pin. If your outlet does not support this kind of plug, contact your electrician to replace your obsolete outlet.
17. CAUTION: DANGER OF EXPLOSION IF BATTERY IS INCORRECTLY REPLACED. REPLACE ONLY WITH THE SAME OR EQUIVALENT TYPE RECOMMENDED BY THE MANUFACTURER. DISCARD USED BATTERIES ACCORDING TO THE MANUFACTURER’S INSTRUCTIONS.
Copyright © 2014 EXOR International S.p.A. All Rights Reserved.
x
Preface
Technical Support and Assistance
1. For the most updated information of EXOR products, visit EXOR’s website at www.exorint.it.
2. For technical issues that require contacting our technical support team or sales representative, please have the following information ready before calling: – Product name and serial number – Detailed information of the peripheral devices – Detailed information of the installed software (operating system,
version, application software, etc.) – A complete description of the problem – The exact wordings of the error messages
Warning!
1. Handling the unit: carry the unit with both hands and handle it with care.
2. Maintenance: to keep the unit clean, use only approved cleaning products or clean with a dry cloth.
3. CompactFlash: Turn off the unit’s power before inserting or removing a CompactFlash storage card.
Conventions Used in this Manual
Warning: Information about certain situations, which if not observed, can cause personal injury. This will prevent injury to yourself when performing a task.
ION!UT
CAUTION!CAUTION!
Caution: Information to avoid damaging components or losing data.
Note: Provides additional information to complete a task easily.
Copyright © 2014 EXOR International S.p.A. All Rights Reserved.
xi
Preface
Package Contents
Before continuing, verify that the package you received is complete. The eTOP-MON series package, eTOP-MON 1200T/1205T/1500T/1700T/1900T, should have all the items listed in the table.
eTOP-MON 1200T/1205T/1500T/1700T
Item Description Qty
1 Panel Mount Kit 12 2 Touch Pen 1 3 VGA Cable (1.8m) 1 4 USB Cable (1.8m) 1 5 Serial Cable (1.8m) 1 6 Terminal blocks 3-pin Phoenix Contact Plug 1 7 Panel Mount Hole Block 12
Panel Mount Kit Touch Pen
Terminal blocks
3-pin Phoenix
Contact Plug
VGA Cable USB Cable
Serial Cable
Panel Mount Hole Block
Note: Package contents may vary depending on your country region, some items may be optional. Please contact your local distributor for more information.
Copyright © 2014 EXOR International S.p.A. All Rights Reserved.
xii
Preface
Item Description Qty
1 Panel Mount Kit 14 2 Touch Pen 1 3 VGA Cable (1.8m) 1 4 USB Cable (1.8m) 1 5 Serial Cable (1.8m) 1 6 Terminal blocks 3-pin Phoenix Contact Plug 1 7 Panel Mount Hole Block 14
eTOP-MON 1900T
Panel Mount Kit Touch Pen
Terminal blocks
3-pin Phoenix
Contact Plug
VGA Cable USB Cable
Serial Cable
Panel Mount Hole Block
Note: Package contents may vary depending on your country region, some items may be optional. Please contact your local distributor for more information.
Copyright © 2014 EXOR International S.p.A. All Rights Reserved.
xiii
Preface
Ordering Information
The following provides ordering information for the Applied Panel Display series.
• Barebone
eTOP-MON 1200T
12.1” SVGA industrial 4:3 LED Backlight flush touch monitor with VGA, and DVI-D input, 12~24VDC input, RS-232 and USB touch screen interfaces
eTOP-MON 1205T
12.1” XGA industrial 4:3 LED Backlight flush touch monitor with VGA, and DVI-D input, 12~24VDC input, RS-232 and USB touch screen interfaces
eTOP-MON 1500T
15” XGA industrial 4:3 LED Backlight flush touch monitor with VGA, and DVI-D input, 12~24VDC input, RS-232 and USB touch screen interfaces
eTOP-MON 1700T
17” SXGA industrial 4:3 LCD flush touch monitor with VGA and DVI-D input, 12~24VDC input, RS-232 and USB touch screen interfaces
eTOP-MON 1900T
19” SXGA industrial 4:3 LED Backlight flush touch monitor with VGA, and DVI-D input, 12~24V DC input, RS-232 and USB touch screen interfaces
• Optional
12V, 60W AC/DC power adapter w/o power cord
US Power Cord UK Power Cord EU Power Cord 1.8m DVI-D Cable
Copyright © 2014 EXOR International S.p.A. All Rights Reserved.
1
Chapter 1: Product Introduction
CHAPTER 1: PRODUCT INTRODUCTION
Key Features
▪ IP65 compliant plastic front bezel with flush panel by 5-wire touch screen
▪ Dual display input interface: analog VGA and DVI-D
▪ Shares identical appearance with APPC series
▪ Dual touch screen interface: RS232 and USB
▪ Ultra slim in depth
▪ OSD Multilanguage function
Overview - eTOP-MON 1200T/1205T
Copyright © 2014 EXOR International S.p.A. All Rights Reserved.
2
Chapter 1: Product Introduction
Key Features
▪ IP65 compliant plastic front bezel with flush panel by 5-wire touch screen
▪ Dual display input interface: analog VGA and DVI-D
▪ Shares identical appearance with APPC series
▪ Dual touch screen interface: RS232 and USB
▪ Ultra slim in depth
▪ OSD Multilanguage function
Overview - eTOP-MON 1500T
Copyright © 2014 EXOR International S.p.A. All Rights Reserved.
3
Chapter 1: Product Introduction
Key Features
▪ IP65 compliant plastic front bezel with flush panel by 5-wire touch screen
▪ Dual display input interface: analog VGA and DVI-D
▪ Shares identical appearance with APPC series
▪ Dual touch screen interface: RS232 and USB
▪ Ultra slim in depth
▪ OSD Multilanguage function
Overview - eTOP-MON 1700T
Copyright © 2014 EXOR International S.p.A. All Rights Reserved.
4
Chapter 1: Product Introduction
Key Features
▪ IP65 compliant plastic front bezel with flush panel by 5-wire touch screen
▪ Dual display input interface: analog VGA and DVI-D
▪ Shares identical appearance with APPC series
▪ Dual touch screen interface: RS232 and USB
▪ Ultra slim in depth
▪ OSD Multilanguage function
Overview - eTOP-MON 1900T
Copyright © 2014 EXOR International S.p.A. All Rights Reserved.
5
Chapter 1: Product Introduction
Specifications
eTOP-MON 1200T
Panel
▪ LED Size: 12.1”, 4:3 ▪ Resolution: SVGA 800x600 ▪ Luminance: 450cd/m
2
▪ Contrast ratio: 700 ▪ LCD color: 16.2M ▪ Viewing Angle: 65(U), 75(D), 80(L), 80(R) ▪ Backlight: LED
Touch Screen
▪ 5-wire resistive (flush panel type) ▪ Light transmission: 80% ▪ Interface: USB and RS232
Rear I/O
▪ Touch screen interface port: RS-232 (1x DB9) / USB Type A ▪ Video port: VGA (1x DB15) / DVI-D (1x DVI-I connector) ▪ DC power input connector: 3-Pin Phoenix terminal Blocks
OSD Function
▪ OSD keypad ▪ Multilanguage OSD
Mechanical & Environment
▪ Color: pantone black ▪ IP protection: IP65 front ▪ Mounting: panel/ wall/ stand/ VESA 100mm x 100mm
▪ Power input: 12V~24VDC ▪ Power adapter: optional AC to DC power adapter (+12V, 60W) ▪ Vibration:
IEC 68 2-64 2Grms @ sine, 5~500Hz, 1hr/axis (Operating)
2.2Grms @ random condition, 5~500Hz, 0.5hr/axis (Non-operating)
▪ Shock:
IEC 68 2-27 20G@wall mount, half sine, 11ms Operating temperature: -5°C to 60°C
Storage temperature: -20°C to 75°C ▪ Operating humidity: 10%~90% relative humidity, non-condensing ▪ Dimension: 317 x 243 x 53.5mm ▪ Weight: 2.9Kg
Certifications
▪ CE approval
Copyright © 2014 EXOR International S.p.A. All Rights Reserved.
6
Chapter 1: Product Introduction
Specifications
eTOP-MON 1205T
Panel
▪ LED Size: 12.1”, 4:3 ▪ Resolution: XGA 1024x768 ▪ Luminance: 500cd/m
2
▪ Contrast ratio: 700 ▪ LCD color: 16.2M ▪ Viewing Angle: 80(U), 80(D), 80(L), 80(R) ▪ Backlight: LED
Touch Screen
▪ 5-wire resistive (flush panel type) ▪ Light transmission: 80% ▪ Interface: USB and RS232
Rear I/O
▪ Touch screen interface port: RS-232 (1x DB9) / USB Type A ▪ Video port: VGA (1x DB15) / DVI-D (1x DVI-I connector) ▪ DC power input connector: 3-Pin Phoenix terminal Blocks
OSD Function
▪ OSD keypad ▪ Multilanguage OSD
Mechanical & Environment
▪ Color: pantone black ▪ IP protection: IP65 front ▪ Mounting: panel/ wall/ stand/ VESA 100mm x 100mm
▪ Power input: 12V~24VDC ▪ Power adapter: optional AC to DC power adapter (+12V, 60W) ▪ Vibration:
IEC 68 2-64
2Grms @ sine, 5~500Hz, 1hr/axis (Operating)
2.2Grms @ random condition, 5~500Hz, 0.5hr/axis (Non-operating)
▪ Shock:
IEC 68 2-27
20G@wall mount, half sine, 11ms
Operating temperature: -5°C to 60°C
Storage temperature: -20°C to 75°C ▪ Operating humidity: 10%~90% relative humidity, non-condensing ▪ Dimension: 317 x 243 x 53.5mm ▪ Weight: 2.9Kg
Certifications
▪ CE approval
Copyright © 2014 EXOR International S.p.A. All Rights Reserved.
7
Chapter 1: Product Introduction
Specifications
eTOP-MON 1500T
Panel
▪ LED Size: 15”, 4:3 ▪ Resolution: XGA 1024x768 ▪ Luminance: 400cd/m
2
▪ Contrast ratio: 700 ▪ LCD color: 16.2M ▪ Viewing Angle: 60(U), 80(D), 80(L), 80(R) ▪ Backlight: LED
Touch Screen
▪ 5-wire resistive (flush panel type) ▪ Light transmission: 80% ▪ Interface: USB and RS232
Rear I/O
▪ Touch screen interface port: RS-232 (1x DB9) / USB Type A ▪ Video port: VGA (1x DB15) / DVI-D (1x DVI-I connector) ▪ DC power input connector: 3-Pin Phoenix terminal Blocks
OSD Function
▪ OSD keypad ▪ Multilanguage OSD
Mechanical & Environment
▪ Color: pantone black ▪ IP protection: IP65 front ▪ Mounting: panel/ wall/ stand/ VESA 100mm x 100mm
▪ Power input: 12V~24VDC ▪ Power adapter: optional AC to DC power adapter (+12V, 60W) ▪ Vibration:
IEC 68 2-64 2Grms @ sine, 5~500Hz, 1hr/axis (Operating)
2.2Grms @ random condition, 5~500Hz, 0.5hr/axis (Non-operating)
▪ Shock:
IEC 68 2-27 20G@wall mount, half sine, 11ms Operating temperature: -5°C to 60°C
Storage temperature: -20°C to 75°C ▪ Operating humidity: 10%~90% relative humidity, non-condensing ▪ Dimension: 384.37 x 310 x 51.2 mm ▪ Weight: 3.98Kg
Certifications
▪ CE approval
Loading...