Exor eTOP 300 Series, eTOP307, eTOP308, eTOP310, eTOP306 Operating Instructions Manual

...
Page 1
User’s Manual for eTOP Series 300 Touchscreen Products
eTOP Series 300
Operating Instructions
MANUGENETOP3xx - Version 2.00 © 2018 EXOR International S.p.A.
Page 2
Copyright © 2018 Exor International S.p.A. – Verona, Italy Subject to change without notice The information contained in this document is provided for informational purposes only. While efforts were made to verify the accuracy of the information contained in this documentation, it is provided “as is” without warranty of any kind. Third-party brands and names are the property of their respective owners. www.exorint.com
MANUGENETOP3xx - Version 2.00 © 2018 EXOR International S.p.A. - Subject to change without notice
2
Page 3
Table of Contents
Introduction 4
Safety guide 5
1 Product overview 6
2 Standards and approvals 7
3 Technical specications 8
4 Technical data 10
4.1 Dimensions 14
4.2 Installation environment 15
4.3 Installation procedure 16
5 Connections 17
5.1 Serial port 18
5.2 Ethernet port 19
6 Power supply, grounding and shielding 20
7 AUX Port 21
8 Battery 22
9 Cleaning faceplates 23
10 Getting started 23
11 Command summary 24
12 Conguration mode 25
13 Special modes: Calibration, conguration and safe mode 26
13.1 Touchscreen calibration 26
13.2 Go to conguration mode 26
13.3 Safe mode 26
14 Dedicated LED indicators 27
15 Unpacking and packing Instructions 28
MANUGENETOP3xx - Version 2.00 © 2018 EXOR International S.p.A. - Subject to change without notice
3
Page 4
Introduction
The operational guidelines described below is information which relates to the device, installation, tran­sportation, storage, assembly, use and maintenance.
This Operating Instruction describes the main features of the operator panels. The Guide refers to the following models:
eTOP306 Operator interface with TFT color 5,7” display eTOP307 Operator interface with TFT color 7” widescreen display eTOP308 Operator interface with TFT color 7.5” display eTOP310 Operator interface with TFT color 10” display eTOP312 Operator interface with TFT color 12” display eTOP313 Operator interface with TFT color 13.3” widescreen display eTOP315 Operator interface with TFT color 15” display
MANUGENETOP3xx - Version 2.00 © 2018 EXOR International S.p.A. - Subject to change without notice
4
Page 5
Safety Guide
The manual contains safety standards that must be respected for the personal safety and to avoid damage. Indications of attention are divided into three levels of severity:
DANGER: indicates a failure to observe safety rules and such failure may cause death or serious injuries.
DANGER
!
ATTENTION: indicates a failure to observe safety rules and that deciency may cause damage.
ATTENTION
!
CAUTION: indicates a failure to observe safety rules and that deciency may cause defects to the equipment
or inconsistencies.
CAUTION
MANUGENETOP3xx - Version 2.00 © 2018 EXOR International S.p.A. - Subject to change without notice
5
Page 6
1 Production Overview
The eTOP Series 300 combines state-of-the-art features and performance with an oustanding design. They are the ideal choice for HMI applications including factory and building automation.
The eTOP Series 300 HMI panels are fully compatible with UniOP Designer 6 software.
Powerful and intuitive programming with the UniOP Designer 6 software.
Supports more than 150 communication drivers.
Built-in Ethernet port for communication with devices, programming the HMI from Designer and
retrieving data from computers.
USB host port for the connection of flash drives. Flash drives can be used for upgrading applications and rmware.
Optional plug-in modules for eldbus systems and networks. Compatible with TCM and SCM
modules.
Dual-driver communication capability.
Vector graphic capabilities including the support of multiple layers and object transparency.
Data display in numerical, text, bargraph, analog gauges and graphic image formats. Dynamic
object properties supported.
Data acquisition and trend presentation. Trend data can be transferred to an host computer using
the Ethernet connection.
Recipe data storage. Recipe data can be transferred to an host computer using the Ethernet
connection or copied to flash drives via USB connection.
Multilanguage applications. Far East languages are supported. The number of runtime languages is limited only by the available memory. All text information in the application can be exported to les
in Unicode format for easier translation.
Powerful macro editor to congure touchscreen operation
Alarms and historical alarm list. Alarm and event information can be printed or transferred to an
host computer.
Eight level password protection.
Report printing to serial printer. Reports are freely congurable using Designer.
Ethernet-based UniNet network to share data between HMIs and to serve data using UniNet OPC
Server.
MANUGENETOP3xx - Version 2.00 © 2018 EXOR International S.p.A. - Subject to change without notice
6
Page 7
2 Standards and Approvals
The products have been designed for use in an industrial environment in compliance with the 2014/30/ EU EMC Directive. The products have been designed in compliance with: EN 61000-6-4 EN 55011 Class A
EN 61000-6-2 EN 61000-4-2 EN 61000-4-3 EN 61000-4-4 EN 61000-4-5 EN 61000-4-6
The installation of these devices into the residential, commercial and light-industrial environments is al­lowed only in the case that special in measures are taken in order to ensure conformity to EN 61000-6-3.
The products are in compliance with the Restrictions on Certain Hazardous Substances (RoHS) Directive 2011/65/EU
In compliance with the above regulations the products are CE marked.
Product Identication
The product may be identied through a plate attached to the rear cover. You will have to know the type
of unit you are using for correct usage of the information contained in the guide.
An example of this plate is shown in the gure below:
eTOP306 product model name ETOP306U1P1 product part number 1846 year/week of production AA0000187123456789AA serial number HW76B3FW76S590P version id of the product
MANUGENETOP3xx - Version 2.00 © 2018 EXOR International S.p.A. - Subject to change without notice
7
Page 8
3 Technical Specications
Touch screen technology Resistive
Back-up battery
3V 50mAh Lithium, rechargeable, not user-replaceable,
model VL2330.
Fuse Automatic PC/Printer Port
RS-232, RS-485, RS-422 software congurable
300 - 38400 baud
PLC Port RS-232, RS-485, RS-422 software congurable
300 - 38400 baud
AUX Port connector D-9 pin female (functionality can be congured
with an optional communication module) User memory 64MB
Recipe memory Flash Hardware clock Clock/Calendar with back-up battery Accuracy RTC (at 25°C operating) <100ppm Alarms 1024 Historical event list last 1024 events with back-up battery Programming software Designer version 6
Environmental conditions
Operating temperature (vertical 0 ÷ +50°C EN 60068-2-14 installation) Storage temperature -20 ÷ +70°C EN 60068-2-14 Operating and storage humidity 5 ÷ 85 % RH not-condensing EN 60068-2-30 Vibrations 5 ÷ 9 Hz, 7 mm
9 ÷ 150 Hz, 1 g
Shock ± 50 g, 11 ms, 3 pulses per axis EN 60068-2-27 Protection class IP66 front panel * EN 60529
* The front face of the unit, installed in a solid panel, has been tested using conditions equivalent to the standards shown in the “Environmental conditions”. Even though the level of resistance unit is equivalent to these standards, oils
that should have no effect on the panel can possibly harm the unit. This can occur in areas where either vaporized oils are present, or where low viscosity cutting oil are allowed to adhere to the unit for long periods of time. If the front face protection sheet on the panel becomes peeled off, these conditions can lead to the ingress of oil into the panel and separate protection measures are suggested. If the installation gasket is used for a long period of time, or if the unit and its gasket are removed from the panel, the original level of the protection cannot be guaranteed.
EN 60068-2-6
p-p
Electromagnetic Compatibility (EMC)
Radiated disturbance test Class A EN 55011 Electrostatic discharge immunity test 8 kV (air electrostatic discharge) EN 61000-4-2
4 kV (contact electrostatic discharge)
Radiated, radio-frequency, 80 MHz ÷ 1 GHz, 10V/m EN 61000-4-3 electromagnetic eld immunity test 1,4 GHz ÷ 2 GHz, 3 V/m
2 GHz ÷ 2.7 GHz, 1 V/m
MANUGENETOP3xx - Version 2.00 © 2018 EXOR International S.p.A. - Subject to change without notice
8
Page 9
3 Technical Specications
Burst immunity test ± 2 KV DC power port EN 61000-4-4 ± 1 KV signal line Surge immunity test ± 0,5 KV DC power port (line to earth) EN 61000-4-5 ± 0,5 KV DC power port (line to line) ± 1 KV signal line (line to earth)
Immunity to conducted disturbances inducted by radiofrequency eld 0.15 ÷ 80 MHz, 10V EN 61000-4-6
Voltage dips, short interruptions and voltage variations immunity test Port: AC mains; Level:
100% duration: 1 cycle and 250 cycles (50Hz); 40% duration: 10 cycles (50Hz); 70% duration: 25 cycles (50Hz); Phase: 0°-180° Test executed on the 230Vac side of the Exor International Power Supply EN 61000-4-11
Durability information
Backlight service life 40000 Hrs. or more (LED type) (Time of continuos operation until the brightness of the
backlight reaches 50% of the rated value when the sorrounding air temperature is 25°C) - see Note 1
Backlight service life 50000 Hrs. or more (CCFL type) (Time of continuos operation until the brightness of the
backlight reaches 50% of the rated value when the sorrounding air temperature is 25°C) - see Note 1
Front foil 10 years if the surrounding air temperature is 25°C (without directly exposure to sunlight or UV ray)
UV Resistance Indoor applications: After 300 hours cycled humidity in
QUV accelerated weathering, some yellowing and brittleness may be present. - see Note 2.
Touch screen reliability > 1 milion operations
Note 1: Extended use in environments where the surrounding air temperature is 40°C or higher may degrade
backlight quality/reliability/durability.
Note 2: Solvent resistance: Contact for 1/2 hour at 21°C, No visible effect: Acetone, Butyl Cellosolve, Cyclohexanone, Ethyl Acetate, Hexane, Isopropyl Alcohol, MEK, Methylene Chloride, Toluene, Xylene Contact for 24 hours at 49°C, No visible effect: Coffee, Ketchup, Lemon Juice, Mustard (slight yellow stain), Tea, Tomato juice.
MANUGENETOP3xx - Version 2.00 © 2018 EXOR International S.p.A. - Subject to change without notice
9
Page 10
4 Technical Data
Model eTOP306 eTOP307
Display / Backlight
Colors
Resolution
Diagonal (inches)
Dimming
Touch screen
User memory Flash
Flash card option
Recipe memory
PLC Port
Programming/Printer port
UniNet (server and client)
Aux port (optional ledbus/
Ethernet)
Ethernet programming
Ethernet port
USB port
Graphic
Video input Option
Trend acquisition and display
Battery
Real Time Clock
Password
Alarms
Event list
Voltage
Current rating (at 24VDC)
Temperature range (vertical installation)
Weight
TFT Color / LED TFT Color / LED
64K 64K
320x240 800x480
5.7” 7” widescreen
yes yes
yes yes
64 MB 64 MB
- -
Yes. Flash memory storage limited only by
available memory
RS-232, RS-485, RS-422 RS-232, RS-485, RS-422
RS-232, RS-485, RS-422 RS-232, RS-485, RS-422
yes yes
yes yes
yes yes
10/100 Mbit 10/100 Mbit
Host interface, version 1.1 Host interface, version 1.1
yes yes
- -
yes yes
rechargeable rechargeable
yes yes
yes yes
1024 1024
1024 1024
18-30VDC 18-30VDC
0.55A 0.55A
0-50°C 0-50°C
1 Kg 1 Kg
Yes. Flash memory storage limited only by
available memory
MANUGENETOP3xx - Version 2.00 © 2018 EXOR International S.p.A. - Subject to change without notice
10
Page 11
4 Technical Data
Model eTOP308 eTOP310
Display / Backlight
Colors
Resolution
Diagonal (inches)
Dimming
Touch screen
User memory Flash
Flash card option
Recipe memory
PLC Port
Programming/Printer port
UniNet (server and client)
Aux port (optional ledbus/
Ethernet)
Ethernet programming
Ethernet port
USB port
Graphic
Video input Option
Trend acquisition and display
Battery
Real Time Clock
Password
Alarms
Event list
Voltage
Current rating (at 24VDC)
Temperature range (vertical installation)
Weight
TFT Color / CCFL TFT Color / CCFL
64K 64K
640x480 640x480
7.5” 10.4”
yes yes
yes yes
64 MB 64 MB
- -
Yes. Flash memory storage limited only by
available memory
RS-232, RS-485, RS-422 RS-232, RS-485, RS-422
RS-232, RS-485, RS-422 RS-232, RS-485, RS-422
yes yes
yes yes
yes yes
10/100 Mbit 10/100 Mbit
Host interface, version 1.1 Host interface, version 1.1
yes yes
- -
yes yes
rechargeable rechargeable
yes yes
yes yes
1024 1024
1024 1024
18-30VDC 18-30VDC
0.8A 0.8A
0-50°C 0-50°C
1.2 Kg 2.1 Kg
Yes. Flash memory storage limited only by
available memory
MANUGENETOP3xx - Version 2.00 © 2018 EXOR International S.p.A. - Subject to change without notice
11
Page 12
4 Technical Data
Model eTOP312 eTOP313
Display / Backlight
Colors
Resolution
Diagonal (inches)
Dimming
Touch screen
User memory Flash
Flash card option
Recipe memory
PLC Port
Programming/Printer port
UniNet (server and client)
Aux port (optional ledbus/
Ethernet)
Ethernet programming
Ethernet port
USB port
Graphic
Video input Option
Trend acquisition and display
Battery
Real Time Clock
Password
Alarms
Event list
Voltage
Current rating (at 24VDC)
Temperature range (vertical installation)
Weight
TFT Color / CCFL TFT Color / LED
64K 64K
800x600 1280x800
12.1” 13.3”
yes yes
yes yes
64 MB 64 MB
- -
Yes. Flash memory storage limited only by
available memory
RS-232, RS-485, RS-422 RS-232, RS-485, RS-422
RS-232, RS-485, RS-422 RS-232, RS-485, RS-422
yes yes
yes yes
yes yes
10/100 Mbit 10/100 Mbit
Host interface, version 1.1 Host interface, version 1.1
yes yes
- -
yes yes
rechargeable rechargeable
yes yes
yes yes
1024 1024
1024 1024
18-30VDC 18-30VDC
1.05A 0.6A
0-50°C 0-50°C
2.8 Kg 2.5 Kg
Yes. Flash memory storage limited only by
available memory
MANUGENETOP3xx - Version 2.00 © 2018 EXOR International S.p.A. - Subject to change without notice
12
Page 13
4 Technical Data
Model eTOP315
Display / Backlight
Colors
Resolution
Diagonal (inches)
Dimming
Touch screen
User memory Flash
Flash card option
Recipe memory
PLC Port
Programming/Printer port
UniNet (server and client)
Aux port (optional ledbus/
Ethernet)
Ethernet programming
Ethernet port
USB port
Graphic
Video input Option
Trend acquisition and display
Battery
Real Time Clock
Password
Alarms
Event list
Voltage
Current rating (at 24VDC)
Temperature range (vertical installation)
Weight
TFT Color / CCFL
64K
1024x768
15”
yes
yes
64 MB
-
Yes. Flash memory storage limited only by
available memory
RS-232, RS-485, RS-422
RS-232, RS-485, RS-422
yes
yes
yes
10/100 Mbit
Host interface, version 1.1
yes
-
yes
rechargeable
yes
yes
1024
1024
18-30VDC
1.1A
0-50°C
3.4 Kg
MANUGENETOP3xx - Version 2.00 © 2018 EXOR International S.p.A. - Subject to change without notice
13
Page 14
4 Technical Data
4.1 Dimensions
MODEL A B C
eTOP306 187mm/7.36” 147mm/5.79” 176mm/6.90” 136mm/5.35” 45mm/1.77” 4mm/0.16”
eTOP307 187mm/7.36” 147mm/5.79” 176mm/6.90” 136mm/5.35” 45mm/1.77” 4mm/0.16”
eTOP308 232mm/9.13” 187mm/7.36” 221mm/8.70” 176mm/6.90” 42mm/1.65” 4mm/0.16”
eTOP310 287mm/11.30” 232mm/9.13” 276mm/10.86” 221mm/8.70” 42mm/1.65” 4mm/0.16”
eTOP312 337mm/13.26” 267mm/10.51” 326mm/9.30” 256mm/10.1” 42mm/1.65” 4mm/0.16”
eTOP313 337mm/13.26” 267mm/10.51” 326mm/9.30” 256mm/10.1” 42mm/1.65” 4mm/0.16”
eTOP315 392mm/15.43” 307mm/12.1” 381mm/15” 296mm/11.65” 46mm/1.82” 4mm/0.16”
MANUGENETOP3xx - Version 2.00 © 2018 EXOR International S.p.A. - Subject to change without notice
D E F
14
Page 15
4 Technical Data
4.2 Installation Environment
The equipment is not intended for continuous exposure to direct sunlight. This might accelerate the aging process of the front panel lm.
The equipment is not intended for installation in contact with corrosive chemical compounds. Check the resistance of the front panel lm to a specic compound before installation.
Do not use tools of any kind (screwdrivers, etc.) to operate the keyboard of the panel or the touch screen.
In order to meet the front panel protection classications, proper installation procedure must be followed:
the borders of the cutout must be flat
• screw up each xing screw until the plastic bezel corner get in contact with the panel.
the cutout for the panel must be of the dimensions indicated in this manual.
The IP65 is guaranteed only if:
• max deviation from the plane surface to the cut-out: O0.5mm
• thickness of the case where is mounted the equipment: from 1,5mm to 6mm
• max surface roughness where the gasket is applied: O120 um
Applying the rectangular gasket
The gasket should be applied on the rear of the frame.
A. Gasket B. Installation cut-out
MANUGENETOP3xx - Version 2.00 © 2018 EXOR International S.p.A. - Subject to change without notice
Fig. 4.1
15
Page 16
4 Technical Data
4.3 Installation Procedure
Place the xing brackets as shown in gure (Fig. 4.2).
Fig. 4.2
CAUTION
Screw each xing screw until the bezel corner gets in contact with the panel
MANUGENETOP3xx - Version 2.00 © 2018 EXOR International S.p.A. - Subject to change without notice
16
Page 17
5 Connections
1. Power
2. Aux Port
3. PLC Port
4. PC/Printer Port
5. Ethernet Port
6. USB Port (Fig. 5.2)
Fig. 5.1
MANUGENETOP3xx - Version 2.00 © 2018 EXOR International S.p.A. - Subject to change without notice
Fig. 5.2
17
Page 18
5 Connections
5.1 Serial Port
The serial port is used to communicate with the PLC or with another type of controller. Different electrical standards are available for the signals in the PLC port connector: RS-232, RS-422, RS-485.
The serial port is software programmable. Make sure you select the appropriate interface in the program­ming software.
RS-232
Pin Description
1 GND 2 3 TX 4 RX 5 6 +5V output 7 CTS 8 RTS 9
The communication cable must be chosen for the type of device being connected.
SERIAL PORT
RS-422, RS-485
Pin Description
1 GND 2 3 CHA­ 4 CHB­ 5 6 +5V output 7 CHB+ 8 CHA+ 9
MANUGENETOP3xx - Version 2.00 © 2018 EXOR International S.p.A. - Subject to change without notice
18
Page 19
5 Connections
5.2 Ethernet Port
Pin Description
1 TX OUT + 2 TX OUT ­ 3 RX OUT + 4 5 6 RX OUT ­ 7 8
1 8
ON: Valid link has NOT been detected OFF: Valid link has been detected
MANUGENETOP3xx - Version 2.00 © 2018 EXOR International S.p.A. - Subject to change without notice
19
Page 20
6 Power Supply, Grounding and Shielding
The power supply terminal block is shown in the gure below.
Power supply terminal block
Fig. 6.1
Note: Ensure that the power supply has enough power capacity for the operation of the equipment.
The unit must always be grounded to earth. Grounding helps limit the effects of noise due to electroma­gnetic interference on the control system.
Earth connection will have to be done using either the screw or the faston terminal located near the power supply terminal block. A label helps identify the ground connection. Also connect to ground the terminal 3 on the power supply terminal block.
The power supply circuit may be floating or grounded. In the latter case, connect to ground the power
source common as shown in gure (see below) with a dashed line.
When using the floating power scheme, note that the panes internally connects the power common to
ground with a 1MΩ resistor in parallel with a 4,7nF capacitor.
The power supply must have double or reinforced insulation. The suggested wiring for the power supply is shown below.
All the electronic devices in the control system must be properly grounded. Grounding must be performed according to applicable regulations.
MANUGENETOP3xx - Version 2.00 © 2018 EXOR International S.p.A. - Subject to change without notice
Fig. 6.2
20
Page 21
7 AUX Port
The AUX Port is a communication port specially designed for industrial network communication. The AUX Port connector is a 9 pin D sub type. The functionality of the AUX Port depends on the optional commu­nication module which is plugged into the unit.
Note: The pin assignment of the Aux Port connector is described in the manual of the communication module
Fig. 7.1
Fig. 7.2
ATTENTION
!
Insert the module pressing simultaneously on the four corners. Do not plug the module and the ETAD adapter when power is applied to the operator panel.
MANUGENETOP3xx - Version 2.00 © 2018 EXOR International S.p.A. - Subject to change without notice
21
Page 22
8 Battery
These devices are equipped with rechargeable Lithium battery, not user-replaceable.
The following information is maintained by the battery:
hardware real-time clock (date and time)
event list
Charge:
At rst installation must be charged for 48 hours.
When the battery is fully charged, it ensures a period of 3 months of data back-up at 25°C.
Battery
ATTENTION
!
Dispose of batteries according to local regulations.
MANUGENETOP3xx - Version 2.00 © 2018 EXOR International S.p.A. - Subject to change without notice
22
Page 23
9 Cleaning faceplates
The equipment must be cleaned only with a soft cloth and neutral soap product. Do not use solvents.
10 Getting Started
Panels must be programmed with the programming package Designer. To program a panel you will have to connect the panel to a personal computer running Designer software
package; the panel must be in Conguration mode to be programmed. Use the cable CA253 to connect
the panel to a personal computer.
TM
The software package Designer is a Windows dowsTM environment is not included in the software package Designer and must already be installed on the personal computer.
The software package can use either the communication ports COM1 or COM2 on the personal computer.
Check that the Designer program is correctly congured to comunicate with the communication port to
which the cable attached. The communication parameters between the panel and the personal computer are: speed: 9600 (models PC/Printer Port sup. also speeds of 19200 and 38400 baud ) parity: none stop bit: 1 The Designer software defaults to the correct parameters.
application and must be properly installed. The Win-
The version of the Designer being used must be compatible with the rmware version of the panel to be programmed. Call for more information on compatibility between rmware and programming software.
MANUGENETOP3xx - Version 2.00 © 2018 EXOR International S.p.A. - Subject to change without notice
23
Page 24
CLEAR
ENTER
11 Command Summary
The panels have an extended set of pre-dened commands. Commands are available for the use of the
built-in system functions including navigation in all system pages.
The chapter describes the touchscreen commands recognized by all panels. Commands are classied
according to the operating modes of the unit.
Panels with touchscreen interface will show a touch keypad on the screen whenever operator input in
required. For System Commands the default keypad in shown in gure. All keypads, except the one shown in Conguration Mode, can be changed by the programmer.
CAUTION
The standard command assignment is described in this chapter. All the commands, except those
dened for Conguration Mode, can be changed, deleted and/or extended using the Keyboard
Macro Editor facility of the programming software.
Touch screen panels will show automatically a numeric keypad whenever the data entry phase is acti-
vated. Pop-up keypads are congurable by users.
Note: The text ‘2 s’ associated to a key means that the key must be held pressed for two seconds to activate the associated function.
MANUGENETOP3xx - Version 2.00 © 2018 EXOR International S.p.A. - Subject to change without notice
24
Page 25
12 Conguration Mode
ENTER shows the type and version of the communication driver stored in the unit (if any) and boot
FW version.
ENTER 2 s returns to Operation Mode if a valid communication driver and a valid project are stored in
the unit (the key must be pressed for 2 seconds).
CLEAR 2 s Call standard touchscreen calibration procedure
2 s Update rmware
2 s Erase Static RAM (Password and Recipe reset)
2 s Shows memory menu
To change the panel IP address, Ethernet GMT and DST settings: touch the item you want to change.
12.1 Operation Mode/Page Mode
To recall the Conguration Mode, touch the screen in an area where no active touch areas have been dened and hold for 2 seconds. The value of 2 seconds can be changed with Designer on disabled requiring the use of a touch button programmed with the specic enter conguration mode macro.
Command Menu
select up select down select left select right
ENTER activate selection CLEAR
System Menu
select up select down activate selection activate selection
ENTER return to Page Mode when EXT is selected CLEAR
return to Page Mode
return to Page Mode
MANUGENETOP3xx - Version 2.00 © 2018 EXOR International S.p.A. - Subject to change without notice
25
Page 26
13 Special Modes: Calibration, Conguration and Safe Mode
13.1 Touchscreen Calibration - “Go to Calibration Mode”
Touchscreen calibration may be required to restore proper operation of the touchscreen interface.
13.1.1 Standard Calibration
1. Recall Conguration Mode
2. Touch and hold CLEAR key on the screen until TOUCH SCREEN CALIBRATION message
appears, then follow the instructions on page (reported also below)
3. touch and hold the x symbol in the right upper corner until it will move to the low left corner of
the screen
4. touch and hold the x symbol in the low left corner
5. touch the key
6. touch the key until the indication to touch the Enter key will be displayed on the screen
7. touch the Enter key
13.1.2 Emergency Calibration
The Emergency calibration procedure should be used in all cases when it would result not possible to go to calibration using the standard procedure.
1. Switch off the unit
2. turn on the unit
3. tap in the middle of the touchscreen with a frequency of about half a second until the operator
panel will enter the Calibration Mode
4. perform the standard calibration procedure.
13.2 “Go to Conguration Mode”
In the case it might prove impossible to switch the operator panel to Conguration Mode due to
problems in the start-up phase, follow the procedure below:
1. Switch off the unit
2. Touch in the middle of the left side of the display screen with the left hand
3. Switch on the operator panel and tap with the right hand in the middle of the right side of the
display screen with a period of about half a second.
4. Continue until the screen will show Conguration Mode
13.3 Safe Mode
Panel “safe” mode allows some specic and special operations to be performed on the unit. Under some circumstances “safe” mode is required to reset the panel contrast adjustment parameters. The panel safe mode activation is similar to the emergency procedure that activates Conguration
Mode at start-up.
1. Switch off the unit
2. Divide the screen in two parts with a horizontal imaginary line; press and hold one nger on the
upper part of the display screen.
3. Switch on the operator panel and tap in the bottom part of the display screen with a period of
about half a second
4. The panel will remain with black screen and system leds blinking
MANUGENETOP3xx - Version 2.00 © 2018 EXOR International S.p.A. - Subject to change without notice
26
Page 27
14 Dedicated LED Indicators
The table below shows the name and the symbol (when available) of the LED indicators dedicated to special functions. Please note that some indicators may be available only in some models of operator panels.
You will nd a complete reference to programming this product in the UniOP User’s Manual.
MANUGENETOP3xx - Version 2.00 © 2018 EXOR International S.p.A. - Subject to change without notice
27
Page 28
15 Unpacking and packing instructions
To repack the unit, please follow the instructions backwards.
MANUGENETOP3xx - Version 2.00 © 2018 EXOR International S.p.A. - Subject to change without notice
28
Loading...