Copyright © 2018 Exor International S.p.A. – Verona, Italy Subject to change without notice The information contained in this document is provided for informational purposes only. While efforts were made to verify the accuracy of the information contained in this documentation, it is provided “as is” without warranty of any kind. Third-party brands and names are the property of their respective owners. www.exorint.com
MANUGENETOP3xx - Version 2.00 © 2018 EXOR International S.p.A. - Subject to change without notice
2
Table of Contents
Introduction 4
Safety guide 5
1 Product overview 6
2 Standards and approvals 7
3 Technical specications 8
4 Technical data 10
4.1 Dimensions 14
4.2 Installation environment 15
4.3 Installation procedure 16
5 Connections 17
5.1 Serial port 18
5.2 Ethernet port 19
6 Power supply, grounding and shielding 20
7 AUX Port 21
8 Battery 22
9 Cleaning faceplates 23
10 Getting started 23
11 Command summary 24
12 Conguration mode 25
13 Special modes: Calibration, conguration and safe mode 26
13.1 Touchscreen calibration 26
13.2 Go to conguration mode 26
13.3 Safe mode 26
14 Dedicated LED indicators 27
15 Unpacking and packing Instructions 28
MANUGENETOP3xx - Version 2.00 © 2018 EXOR International S.p.A. - Subject to change without notice
3
Introduction
The operational guidelines described below is information which relates to the device, installation, tran­sportation, storage, assembly, use and maintenance.
This Operating Instruction describes the main features of the operator panels. The Guide refers to the following models:
eTOP306 Operator interface with TFT color 5,7” display eTOP307 Operator interface with TFT color 7” widescreen display eTOP308 Operator interface with TFT color 7.5” display eTOP310 Operator interface with TFT color 10” display eTOP312 Operator interface with TFT color 12” display eTOP313 Operator interface with TFT color 13.3” widescreen display eTOP315 Operator interface with TFT color 15” display
MANUGENETOP3xx - Version 2.00 © 2018 EXOR International S.p.A. - Subject to change without notice
4
Safety Guide
The manual contains safety standards that must be respected for the personal safety and to avoid damage. Indications of attention are divided into three levels of severity:
DANGER: indicates a failure to observe safety rules and such failure may cause death or serious injuries.
DANGER
!
ATTENTION: indicates a failure to observe safety rules and that deciency may cause damage.
ATTENTION
!
CAUTION: indicates a failure to observe safety rules and that deciency may cause defects to the equipment
or inconsistencies.
CAUTION
MANUGENETOP3xx - Version 2.00 © 2018 EXOR International S.p.A. - Subject to change without notice
5
1 Production Overview
The eTOP Series 300 combines state-of-the-art features and performance with an oustanding design. They are the ideal choice for HMI applications including factory and building automation.
The eTOP Series 300 HMI panels are fully compatible with UniOP Designer 6 software.
Powerful and intuitive programming with the UniOP Designer 6 software.
Supports more than 150 communication drivers.
Built-in Ethernet port for communication with devices, programming the HMI from Designer and
retrieving data from computers.
USB host port for the connection of flash drives. Flash drives can be used for upgrading applications and rmware.
Optional plug-in modules for eldbus systems and networks. Compatible with TCM and SCM
modules.
Dual-driver communication capability.
Vector graphic capabilities including the support of multiple layers and object transparency.
Data display in numerical, text, bargraph, analog gauges and graphic image formats. Dynamic
object properties supported.
Data acquisition and trend presentation. Trend data can be transferred to an host computer using
the Ethernet connection.
Recipe data storage. Recipe data can be transferred to an host computer using the Ethernet
connection or copied to flash drives via USB connection.
Multilanguage applications. Far East languages are supported. The number of runtime languages is limited only by the available memory. All text information in the application can be exported to les
in Unicode format for easier translation.
Powerful macro editor to congure touchscreen operation
Alarms and historical alarm list. Alarm and event information can be printed or transferred to an
host computer.
Eight level password protection.
Report printing to serial printer. Reports are freely congurable using Designer.
Ethernet-based UniNet network to share data between HMIs and to serve data using UniNet OPC
Server.
MANUGENETOP3xx - Version 2.00 © 2018 EXOR International S.p.A. - Subject to change without notice
6
2 Standards and Approvals
The products have been designed for use in an industrial environment in compliance with the 2014/30/ EU EMC Directive. The products have been designed in compliance with: EN 61000-6-4 EN 55011 Class A
EN 61000-6-2 EN 61000-4-2 EN 61000-4-3 EN 61000-4-4 EN 61000-4-5 EN 61000-4-6
The installation of these devices into the residential, commercial and light-industrial environments is al­lowed only in the case that special in measures are taken in order to ensure conformity to EN 61000-6-3.
The products are in compliance with the Restrictions on Certain Hazardous Substances (RoHS) Directive 2011/65/EU
In compliance with the above regulations the products are CE marked.
Product Identication
The product may be identied through a plate attached to the rear cover. You will have to know the type
of unit you are using for correct usage of the information contained in the guide.
An example of this plate is shown in the gure below:
eTOP306 product model name ETOP306U1P1 product part number 1846 year/week of production AA0000187123456789AA serial number HW76B3FW76S590P version id of the product
MANUGENETOP3xx - Version 2.00 © 2018 EXOR International S.p.A. - Subject to change without notice
7
3 Technical Specications
Touch screen technology Resistive
Back-up battery
3V 50mAh Lithium, rechargeable, not user-replaceable,
model VL2330.
Fuse Automatic PC/Printer Port
RS-232, RS-485, RS-422 software congurable
300 - 38400 baud
PLC Port RS-232, RS-485, RS-422 software congurable
300 - 38400 baud
AUX Port connector D-9 pin female (functionality can be congured
with an optional communication module) User memory 64MB
Recipe memory Flash Hardware clock Clock/Calendar with back-up battery Accuracy RTC (at 25°C operating) <100ppm Alarms 1024 Historical event list last 1024 events with back-up battery Programming software Designer version 6
Environmental conditions
Operating temperature (vertical 0 ÷ +50°C EN 60068-2-14 installation) Storage temperature -20 ÷ +70°C EN 60068-2-14 Operating and storage humidity 5 ÷ 85 % RH not-condensing EN 60068-2-30 Vibrations 5 ÷ 9 Hz, 7 mm
9 ÷ 150 Hz, 1 g
Shock ± 50 g, 11 ms, 3 pulses per axis EN 60068-2-27 Protection class IP66 front panel * EN 60529
* The front face of the unit, installed in a solid panel, has been tested using conditions equivalent to the standards shown in the “Environmental conditions”. Even though the level of resistance unit is equivalent to these standards, oils
that should have no effect on the panel can possibly harm the unit. This can occur in areas where either vaporized oils are present, or where low viscosity cutting oil are allowed to adhere to the unit for long periods of time. If the front face protection sheet on the panel becomes peeled off, these conditions can lead to the ingress of oil into the panel and separate protection measures are suggested. If the installation gasket is used for a long period of time, or if the unit and its gasket are removed from the panel, the original level of the protection cannot be guaranteed.
EN 60068-2-6
p-p
Electromagnetic Compatibility (EMC)
Radiated disturbance test Class A EN 55011 Electrostatic discharge immunity test 8 kV (air electrostatic discharge) EN 61000-4-2
4 kV (contact electrostatic discharge)
Radiated, radio-frequency, 80 MHz ÷ 1 GHz, 10V/m EN 61000-4-3 electromagnetic eld immunity test 1,4 GHz ÷ 2 GHz, 3 V/m
2 GHz ÷ 2.7 GHz, 1 V/m
MANUGENETOP3xx - Version 2.00 © 2018 EXOR International S.p.A. - Subject to change without notice
8
3 Technical Specications
Burst immunity test ± 2 KV DC power port EN 61000-4-4 ± 1 KV signal line Surge immunity test ± 0,5 KV DC power port (line to earth) EN 61000-4-5 ± 0,5 KV DC power port (line to line) ± 1 KV signal line (line to earth)
Immunity to conducted disturbances inducted by radiofrequency eld 0.15 ÷ 80 MHz, 10V EN 61000-4-6
Voltage dips, short interruptions and voltage variations immunity test Port: AC mains; Level:
100% duration: 1 cycle and 250 cycles (50Hz); 40% duration: 10 cycles (50Hz); 70% duration: 25 cycles (50Hz); Phase: 0°-180° Test executed on the 230Vac side of the Exor International Power Supply EN 61000-4-11
Durability information
Backlight service life 40000 Hrs. or more (LED type) (Time of continuos operation until the brightness of the
backlight reaches 50% of the rated value when the sorrounding air temperature is 25°C) - see Note 1
Backlight service life 50000 Hrs. or more (CCFL type) (Time of continuos operation until the brightness of the
backlight reaches 50% of the rated value when the sorrounding air temperature is 25°C) - see Note 1
Front foil 10 years if the surrounding air temperature is 25°C (without directly exposure to sunlight or UV ray)
UV Resistance Indoor applications: After 300 hours cycled humidity in
QUV accelerated weathering, some yellowing and brittleness may be present. - see Note 2.
Touch screen reliability > 1 milion operations
Note 1: Extended use in environments where the surrounding air temperature is 40°C or higher may degrade
backlight quality/reliability/durability.
Note 2: Solvent resistance: Contact for 1/2 hour at 21°C, No visible effect: Acetone, Butyl Cellosolve, Cyclohexanone, Ethyl Acetate, Hexane, Isopropyl Alcohol, MEK, Methylene Chloride, Toluene, Xylene Contact for 24 hours at 49°C, No visible effect: Coffee, Ketchup, Lemon Juice, Mustard (slight yellow stain), Tea, Tomato juice.
MANUGENETOP3xx - Version 2.00 © 2018 EXOR International S.p.A. - Subject to change without notice
9
Loading...