•Follow the manufacturer’s instructions for the device and general safety directions.
•This device must be earthed.
Disposal:
No special precautions. The product should be disposed of in accordance with national regulations governing disposal of electronic waste.
GB
1.1 Contents of the package
Contains:
1 EW41 control panel
1 Power unit for installation on chimney
1 Temperature sensor
1 Bag containing brackets for the temperature sensor, rawlplugs, screws, etc.
4 AA (LR6) batteries
Installation and operation guide
Quick guide
EW41EUxx
Batch no.: xxxx
The serial number can be found on the back of the control panel
Version: x.xx
1.2 Accessories
Optional accessories (order separately)
Item no.ItemDescription
EW41REPEATERSignal amplierIf the power unit and control panel have to be placed at a distance
which exceeds the signal range, the signal can be boosted using a
signal amplier. This may be purchased as optional equipment.
0502232Power adapterIf you wish to connect the control panel to mains power, use a
230 V power adapter. Batteries will then no longer be required.
1100703Bracket for mounting on
a steel chimney
0502301Additional control panelIf you wish to be able to operate the chimney fan from more than
If the power unit has to be mounted on a steel chimney, an
installation kit is available for this purpose.
one control panel, several may be connected to the system.
3 / 12
3110055-2011-01-13
1.3 Application
The EXHAUSTO CDT EW41 wireless controller and EXHAUSTO CDT chimney fan have been develo-
ped for use with replaces, wood-burning stoves and solid fuel boilers.
The controller can start the chimney fan automatically in response to the temperature sensor. It can
also be started by pressing the on/off switch on the control panel. The temperature sensor monitors
the replace and provides notication when more fuel should be added. If the temperature falls even
further, the chimney fan is switched off. The controller only requires simple programming in order for
the EW41 to be used optimally with an open replace or a wood-burning stove/boiler.
The controller can also provide a warning if the chimney temperature becomes too high.
Ventilation
The controller may be used to control the chimney fan even without heat in the replace, if room ventilation is desired.
1.3.1 Function - with temperature sensor activated
Start-up function
Activate the EW41 by pressing the ON/OFF button on the control panel. The controller starts the
chimney fan at the start-up speed. After a pre-set time interval, the speed is reduced to a lower setting.
The factory setting for max. speed is 100 % for 7 min.
Automatic start
If you forget to start the chimney fan before lighting the re, it will automatically start when the temperature sensor reaches the set start temperature.
The factory setting is 40 degrees.
GB
Add fuel function
The control panel indicates when it is time to add more fuel. RELOAD is displayed and the control
panel beeps twice and lights up.
If you wish to add fuel, press the OK button before doing so. This causes the controller to maximise
the draw for 3 min.
Automatic stop
When fuel is no longer added, the temperature at the sensor will slowly drop. Once the temperature
has fallen to the set stop value, the controller continues to operate the chimney fan for a set time period
to extract the last smoke. The factory setting is 45 min.
High-temperature warning
The control panel display will light up and it will beep ve times if the sensor temperature exceeds the
set value. The factory setting is 330 °C.
Pressing any button on the control panel will immediately silence the alarm.
1.3.2 Function - with temperature sensor deactivated (ventilation)
Ventilation:
If the temperature sensor has been deactivated in the user menu, the controller may be used to adjust
the chimney fan speed in 10% intervals. This is useful when ventilating the room.
NB:
Automatic start and stop are also deactivated.
1.4 Installation
Signals
The power unit and control panel should face each other for the
best possible contact.
Mount the power unit on the chimney where the most direct line of
sight is achieved.
Max. 1 metre from the chimney fan so the cable can reach.
Max.
1m
M
a
x
.
1
2
m
Range
The distance between the devices should not exceed 12 metres.
4 / 12