© Excell Precision Limited 2016. All rights reserved Worldwide. The information contained herein is the property of Excell Precision Limited and is supplied without liability for errors or omissions. No part may be reproduced or used except as authorised by contract or other written permission. The copyright and the foregoing restriction on reproduction and use extend to all media in which the information may be embodied.
02027011 ZSME300000342
1
EXCELL PRECISION CO., LTD.
TABLE OF CONTENT
Function Table.................................................................................................................................... 2
Intructions for Use ............................................................................................................................. 5
Preparing to Use the Scale .............................................................................................................. 5
Chapter 1 Introduction ...................................................................................................................... 7
1-1 Features ................................................................................................................................... 7
1-2 Specifications .......................................................................................................................... 7
1-3 Appearance ............................................................................................................................. 7
1-4 Display Description ................................................................................................................ 9
1-5 Power Supply .......................................................................................................................... 9
1-6 Keypad Function ...................................................................................................................10
1-7 Error Messages .................................................................................................................... 11
1-8 Available Units....................................................................................................................... 11
1-9 Firmware Version.................................................................................................................. 11
Chapter 2 General Function Setting.............................................................................................12
2-1 Backlight and Auto. Power Off Setting ..............................................................................12
2-2 Simple Counting Mode ........................................................................................................12
2-3 Accumulation .........................................................................................................................13
2-4 Hold Mode (Animal) .............................................................................................................14
2-5 Self-Test Mode ......................................................................................................................15
Chapter 3 Further Function Setting ..............................................................................................16
3-1 Enter Function Setting .........................................................................................................16
3-2 Function Setting ....................................................................................................................16
3-2-1 Hi / Lo / OK Setting (P0 ChK) .....................................................................................17
3-2-2 RS-232 Setting (P2 CoM) ............................................................................................18
3-2-3 Transmit Mode Setting .................................................................................................19
3-2-4 Real Time Clock Setting ..............................................................................................20
3-2-5 Continuous Transmit Rate (rPS) ................................................................................20
3-3 Other Function Settings (P4 oth) .......................................................................................21
3-4 Weight Unit Setting (P5 unt) ...............................................................................................22
3-5 External calibration (P6 ZCL) .............................................................................................23
3-6 Restore Default Setting (P7 rSt).........................................................................................23
Chapter 4 Wireless Connection Instruction
..................................................................................24
Appendix 1 Output Format.............................................................................................................30
Appendix 2 ASC II Code Table ......................................................................................................32
Appendix 3 7-Segment Display Characters ................................................................................33
Appendix 4 Wiring Instructions......................................................................................................34
02027011 ZSME300000342
2
EXCELL PRECISION CO., LTD.
Function Table
For non-approval models
Main menu
Sub-menu
Available
settings
Description
P0 ChK
(Hi/OK/Lo Setting)
(3-2-1)
SEt h
High limit value (weighing)
SEt L
Low limit value (weighing)
PCS h
High limit value (counting)
PCS L
Low limit value (counting)
bEEP
no
No beep
oK*
Beep within the high and lower limits value
nG
Beep beyond the high or lower limits value
P1 rEF
Function Reserved
Pr2 CoM
(RS-232 Setting)
(3-2-3)
ModE
(3-2-4)
Auto
Auto accumulate transmit
CoMAnd
Command mode
Cont
Continuous transmit
St1*
Stable transmit (Single)
StC
Stable transmit (Continuous)
Pr1
Press key to transmit
Pr2
Press key to transmit
bAud
Baud rate setting: 600, 1200, 2400, 4800, 9600*, 19200
Pr
Communication setting: *n81, E71, o71
rPS
Continuous Transmit rate: 1, 2, 4, 8, 16 or MAX* (3-2-6)
PtyPE
PtUP*
Print type: Standard print
Lab
Output format: 0*, 1, 2, 3
Prt
LAnG
ENG*
Language:English
rtC
RTC setting (3-2-5)
rtCFO
Time display: year_month_day or day_month_year
rS485
RS-485 ID entering
P3 CAL
Function Reserved
P4 oth
(Other setting)
(3-4)
AnM
Animal mode: on, oFF*
AVErG
Auto average unit weight: on, oFF*
r tAr
Tare range
St
Continuous tare: on*, oFF
Ft FnC
Foot switch: ZEro*, tArE, rint
P5 unt
(weight unit setting)
(3-5)
G
Use gram: on, oFF
Lb
Use pound: on, oFF
oZ
Use pound ounce: on, oFF
tJ
Use Taiwan Tael: on, oFF
hJ
Use H.K. Tael: on, oFF
ViSS
Use viss: on, oFF
P6 ZCL
External calibration
P7 rSt
Restore default setting
Default settings are marked by *
02027011 ZSME300000342
3
EXCELL PRECISION CO., LTD.
For approval models
Main menu
Sub-menu
Available
settings
Description
P0 ChK
(Hi/OK/Lo Setting)
(3-2-1)
SEt h
High limit value (weighing)
SEt L
Low limit value (weighing)
PCS h
High limit value (counting)
PCS L
Low limit value (counting)
bEEP
no
No beep
oK*
Beep within the high and lower limits value
nG
Beep beyond the high or lower limits value
Pr2 CoM
(RS-232 Setting)
(3-2-3)
ModE
(3-2-4)
Auto
Auto accumulate transmit
CoMAnd
Command mode
Cont
Continuous transmit
St1*
Stable transmit (Single)
StC
Stable transmit (Continuous)
Pr1
Press key to transmit
Pr2
Press key to transmit
bAud
Baud rate setting: 600, 1200, 2400, 4800, 9600*, 19200
Pr
Communication setting: *n81, E71, o71
rPS
Continuous Transmit rate: 1, 2, 4, 8, 16 or MAX* (3-2-6)
PtyPE
PtUP*
Print type: Standard print
Lab
Output format: 0*, 1, 2, 3
Prt
LAnG
ENG*
Language:English
rtC
RTC setting (3-2-5)
rtCFO
Time display: year_month_day or day_month_year
rS485
RS-485 ID entering
P4 oth
(Other setting)
(3-4)
AnM
Animal mode: on, oFF*
AVErG
Auto average unit weight: on, oFF*
r tAr
Tare range
St
Continuous tare: on*, oFF
Ft FnC
Foot switch: ZEro*, tArE, rint
P5 unt
(weight unit setting)
(3-5)
G
Use gram: on, oFF
Lb
Use pound: on, oFF
oZ
Use pound ounce: on, oFF
tJ
Use Taiwan Tael: on, oFF
hJ
Use H.K. Tael: on, oFF
ViSS
Use viss: on, oFF
Default settings are marked by *
02027011 ZSME300000342
4
EXCELL PRECISION CO., LTD.
SPECIAL NOTICE
While installing the load cell, power cord hookup or replacing a new rechargeable battery, the indicator housing must be opened. It must be done by a technician assigned by your electronic indicator provider to avoid affecting the waterproof ability of this indicator. Before opening the housing, make sure the indicator is dry, if there is any liquid on it, please wipe it with a clean cloth.
HOW TO INSTALL THE HOUSING
After installing the load cell, power cord hookup or replacing a new rechargeable battery, the housing must be screwed by the assigned order as shown below. Screw lightly first, then screw them tight using a 12 kgf-cm torsion. P.s. Please use a torsion-adjustable screw driver.
Screwing order:
1
3
6
5
2
4
QWS
GWS
GWS
02027011 ZSME300000342
5
EXCELL PRECISION CO., LTD.
Intructions for Use
1. The load placed on the weigh pan must NOT exceed the maximum weighing capacity
of the scale.
2. Protect the scale from high temperatures.
3. Avoid objects impacting with the scale. Do not drop loads onto the scale or subject the
weigh pan to any strong shock loads.
4. Please operate or charge the scale in an open area. Do not squeeze the power cord to
avoid wire on fire.
5. Any suggestion for product is welcomed
Preparing to Use the Scale
1. Locate the scale on a firm level surface free from vibrations for accurate weight
readings.
2. Adjust the four levelling feet (if fitted) to set the scale pan level.
3. Avoid operating the scale in direct sunlight or drafts of any kind.
4. If possible avoid connecting the scale to ac power outlet sockets which are adjacent to
other appliances to minimise the possibility of interference affecting the performance of the scale.
5. Remove any weight that might be on the weigh pan before the scale is switched on
and avoid leaving weight on the pan for long periods of time
6. All goods weighed should be placed in the centre of the weigh pan for accurate
weighing. The overall dimensions of the goods being weighed should not exceed the dimension of the weigh pan.
7. Once the scale has been powered on, it will go through an LCD display test and it is
ready for use when the display shows zero.
8. The scale requires 15~20 minutes warm up before operation to ensure best accuracy
9. Please note when the symbol keeps flashing on the screen, the batteries need to
be recharged.
10. Introduction of Storage Battery
Thank you for purchasing EXCELL Weighing Indicator, to help use the product properly, operate smoothly, and extend its life cycle,
please read this manual carefully.
02027011 ZSME300000342
6
EXCELL PRECISION CO., LTD.
No burning
Caution Corrosion
Due to the storage battery adopt the advanced free-maintaining technique, customers need not to replenish electrolyte. The scale should be recharged every 3 months to prevent failure of the internal rechargeable battery.
1. The battery should be charged for 8~10 hours.
2. The temperature of battery should below 45.
Maintaining
1. Please do not discharge with over-current when using the battery. Please charge the
battery after discharging current.
2. Please take down the battery when the scale is not used for a long time or break the
connection of cathode.
3. Do not short the battery terminals to check whether there is current. Please check
whether the connection point is firm to guarantee good connection.
4. The battery should be replaced by specialized person. No reverse-battery or the
product will be damaged.
a) Anode of battery should be connected with Anode of product battery(usually red
cable
b) Cathode of battery should be connected with Cathode of product battery (usually
brown cable or black cable)
c) See the picture following
Safety warnings
1. The electrolyte of battery is caustic which causes metal, cotton, etc to corrode.
2. The hydrogen will be resolved when using or charging the battery and it will cause
explosion when approaches fire.
Brown cable(or black cable) connected with Cathode of battery
Red cable connected with Anode of battery
Warning explosion
Children faraway
02027011 ZSME300000342
7
EXCELL PRECISION CO., LTD.
80 mm
Chapter 1 Introduction
1-1 Features
Extra-large and wide LCD display (175 x 70mm) 6 digits with 55mm height COOL WHITE LED backlight QWS with 304 stainless steel housing while GWS with plastic ABS housing. Sealed to IP68, Waterproof, mist-proof and dustproof (Only use cables of 3mm~5mm
diameter to ensure correct sealing of the cable glands)
Kilogram (kg) and pound (lb) weighing modes Full range tare; Pre-tare; Auto zero tracking; Sampling counting; Gross/Net indication Hold function; Check mode Lo/Hi/OK; Auto average unit weight; Adjustable gravity value Low power indication and auto power off AC/DC power in and rechargeable battery. Built-in RS-232 Options: wireless transmitter, foot switch, pressure release valve, and RS-485
1-2 Specifications
Analogue Input: Input Sensitivity 0.3 V/d (Min.) Input Signal Range: -1mV~+14mV Input Zero Range: -1mV~+5mV Load Cell Excitation: 5V DC Load Cell Drive Capacity: Up to 8 x 350 load cells Non-linearity: 0.01% of full scale A/D Resolution: 500,000 counts (Maximum) Operating temperature: -10 ~ 40
1-3 Appearance
QWS
232 mm
170mm
02027011 ZSME300000342
8
EXCELL PRECISION CO., LTD.
[Standard] [Option]
GWS
[Standard] [Option]
Power
RS-232
Load Cell
Power
Foot switch or RS-485
Pressure relieve valve or RS-485
RS-232
Load Cell
90mm
156m
238mm
Power
Load Cell
RS-232
Foot switch
RS-485
Load Cell
RS-232
Power
02027011 ZSME300000342
9
EXCELL PRECISION CO., LTD.
1-4 Display Description
HI
:
Upper limit
indications description
OK
:
Value between HI and LO
1
:
“STABLE” indication
LO
:
Lower limit
2
:
GROSS” indication
kg
:
Unit “kilogram”
3
:
Hold” indication
g
:
Unit “gram”
4
:
Pre-tare indication
lb
:
Unit “pound”
5
:
Range 2
:
Unit hk tael” or “Taiwan tael”
6
:
Range 1
Pcs
:
“Counting mode” indication
7
:
M+ indication
O
:
Zero indication
Net
:
Net indication
:
Flashing,Low Power indication
1-5 Power Supply
Power Supply Selection
6V / 4.5Ah rechargeable battery 110/230VAC ±15 (plugged-in)
Power Consumption
Approximately DC 31 mA (Indicator + Load Cell) Approximately DC 65 mA (Indicator + Load Cell + Display backlight) Approximately DC 80 mA (Indicator + Load Cell + Wireless 100M) Approximately DC 65 mA (Indicator + Load Cell + Display backlight +Wireless 100M)
Charging Voltage
DC 10V/1A
Low Battery Warning
Please note when the ( ) symbol keeps flashing on the display, the battery should be recharged.
1 2 3 4 5 6 7
02027011 ZSME300000342
10
EXCELL PRECISION CO., LTD.
The scale will turn off automatically after a few hours when the low battery warning
symbol shows up. The scale must be fully charged, before operating again.
When the battery status indication is full, the power is about 6.1V; each block is about
0.2V; when the battery warning symbol shows up, the power is about 5.4V.
1-6 Keypad Function
Press the key to switch the indicator on or off.
Zero key. If the weighing value is within the range of zero balance, it can be
re-zeroed. Confirm key in function operating Press this key for 3 seconds to enter backlight setting in weighing mode.
Shift between gross weight and net weight. Press this key for 3 seconds to
shift units in weighing mode. Press this key for 3 seconds to exit in simple counting mode Press this key to exit or return in function operating.
Print key. It needs to connect with printer. According to the setting, press this
key to transmit simple or completed mode format. Press this key to clear the entering numbers.
 Accumulation key. According to the setting, press this key to transmit simple or
completed mode format. Press this key to move the cursor leftward when entering numbers. Press this key for 3 seconds to display in high resolution mode.
 Check accumulation counts and total weight. Press this key for 3 seconds to
enter simple counting mode in weighing mode. Press this key to move the cursor rightward when entering numbers.
Tare key. It can be tare except when the weight is negative and the maximum
capacity. It is selection key in function operating. Press this key to increase number when entering numbers.
Pre-tare function:
When there is nothing on the platter and weight is zero, press key and enter
pre-tare weight. After enter pre-tare weight, press key to comfirm or press key to exit without saving. Pre-tare mode, keypad function as following
upward key move cursor leftward save setting
clear move cursor rightward exit without saving