The product is good packing when ship out the factory. All users should strictly abide by the
warnings and instructions stated in this manual, any damage and results due to misuse and the
neglect of this operating manual will be excluded from the deal responsibility this manual will not
informed in additionally if have technical changes.
DISPLAY PRODUCTION DESCRIPTION
Thank you for choose this EXX-ML Beam 10R 280W products, this model is the moving head
light which is the latest development of the smart, efficient products, beautiful shape, smooth R &
D, combined with the advanced technology of today's stage lighting products with international
advanced electronic control technology and excellent user-friendly industrial design , fully
comply with CE standard, accepted international standard DMX512 signal mode.
This moving head lights, use ceramic luminescent film reflector as a condenser system, coupled
with the high-quality optical lens components, broadband voltage, a clear pattern, sharp and
uniform output light efficiency. Intelligent LED display module, the English language selection
mode, intuitive operating menu, shortcut.
EXX-ML Beam 10R 280W, have 16/20 international standard DMX512 channels optional
Horizontal scan: 540 ° vertical scanning 270 ° (16bit precision scanning) electronic correction,
dot-matrix display, four touch switch LCD + single-Key flying shuttle can spin. The can be
inverted 180 °, the color wheel is combined with white and 14 colors. Gobo wheel: 7 patterns +
white effect round by eight prism and atomization function. 0-100% mechanical dimmer, support
mechanical strobe and variable strobe effect, strobe macro function. The optical system of the lens
group electric focusing, the beam angle of 0 to 4 ° with overheating protection function
Moving head lights are widely used in television, disco, dance halls, nightclubs, large-scale
performances and other professional venues
1. PRODUCT INTRODUCTION
1.1BEAM SIZE
Size:395(L)×287(W)×495(H)mm
Net Weight:17.5KG
2. SAFETY INFORMATION
Safety warning message
This product is only suitable for professional use, and does not apply to security for other purposes.
After you got the lights, please check the package whether have any damage caused by
transportation. If there is any damage, do not use this fixture, and please contact the dealer or
5
manufacturer as soon as possible.
This product is only suitable for indoor, IP20 protection class. Lamps should be kept dry to avoid
Moisture, overheating or dusty environment. Prevent lamps come into contact with water or any
other liquid.
The use of this product should pay attention to: fire, heat, electric shock, ultraviolet radiation, the
lamp to explode or
Shedding caused serious or fatal injury.
Need to read the instructions before use energized or installing.
Follow through the operation of security methods and pay attention to the warning signs on the
specification and equipment. If you have any problem for how to safely operate the equipment.
Please contact your dealer.
2.1 ANTI-HIGH TEMPERATURE
Ta =40
Please don’t use the equipment if the temperature above 40℃
2.2 BURST PREVENTION
The lens should be changed if had damaged or any problems. Don’t change the
non-original manufacturer lens.
Len size:¢136×60 mm
2.3 TO PREVENT FALLING WOUNDING
Please don’t move the package by one person only.
When Hang the fixture, please must verify that the facilities to be able to
withstand the weight of the lamps at least 10 times more.
Please make sure the Mounting hardware is strong enough no any damage, and
insurance for the safety rope as auxiliary security fixed in other facilities will
need to verify before installation. Installing or removing the equipment, to make
the pulley below the work location
2.4 UA PROTECTION AND THE BULB EXPLOSION
Prohibit straight viewpoint with exposed bulbs to avoid UV damage to the eyes;
Do not use the equipment without the lens screen and the lid;
The lens and the light head covers should be timely replaced if any damage to rupture
The Fixture should be used with the protection screen together.
6
2.5 PREVENTION OF ELECTIC SHOCK
The electrical connection must only be carried out with corresponding qualifications;
Before installing, make sure you use the power voltage lamps must comply with the identified
power, voltage and have an overload or leakage protection;
Each lamp must be properly grounded, installed in accordance with the relevant standards;
Cut off the power when stall or replace the lamp and the fuse;
Prohibit the use of a lightning storm or wet environment.
2.6 TO PREVENT BURNING OR FIRE
1. The fixture can be mounted directly on the surface of ordinary combustible
material.
2. Do not short-circuit temperature protection switch or fuse, use the specified type of fuse.
3. The equipment must be installed away from inflammable and explosive materials.
4. The equipment should be projected range of 3 meters away objects and projectiles
temperature less than 60 ° C; ---- 3.0m.
5. Fan or ventilation, at least in the range of 0.5 meters can not be an obstacle.
6. Do not place any object on the lens.
7. Handling at least allow the device to cool for 20 minutes.
8. Do not replace the non-original parts.
3. PACKAGE
3.1 ATTACHMENT
Beam200 packed with fly-case of one in one ,two in one ,or carton box.
Attach follow accessory.
ACCESSORY
CONTENT QUANTITY
USER MANUL 1
SAFTY ROPE 1
HANG FIXTURE 2
SIGNAL CABLE 1
PACAKGE SIZE
CARTON BOX 410*490*600
FLY-CASE 1 IN 1 690*470*430
7
FLY-CASE 2 IN 1 985*450*735
3.2 TRANSPORT PROTECT LOCK
In order to protect the light, there is a protect lock; During the transport , the lock will closed
keeping the item in safety state.
3.3 ABOUT PACK STAGE
1. Before packed, make sure power is off, and wait for at least 20mins for cooling down.
2. Before clean the fixture, make sure X, Y axis protect lock closed.
3. After packed by plastic bag, high-lift the fixture with two handles besides the product. put
the product into the fly-case up-side-down.
4. After packed the product, put the accessory into the accessory case, then closed and lock the
fly-case.
5. Fly-case only up stacked two layers. Prohibited upside down
6. When packed with carton box, equipment should be put into the foam first, then set into a
carton, pay attention to the vertical position.
3.4 UNPACKING
Note: Before unpacking check the damage is whether due to the transportation or not, if you find any
such damage, please do not use this item, and contact with the dealer or manufacturer as soon as
possible.
1. Open the fly-case, and discover the inside plastic bag.
2. High-lift the product by two handles beside the bottom base and move it out.
3. Before power on, make sure you have opened the X, Y axis lock!
4.INSTALL STRANDARD
4.1 INSTALL LOCK
EXX-ML Beam 10R 280W can be placed on the stage, or mounted in an arbitrary direction of
the truss. Two fast locks system could fix the item easily
4.2 EQUIPMENT FIXED
1. Before installation must verify the fast lock is keep in good state, and can withstand at
least 10 times the weight of product. Verify that the building can withstand at least 10
times of the total weight of the product and accessory equipments.
2. Fix the hang fixture into the hole, which located on the base of the price.
Seize handle of fasteners, clockwise rotate 1/4 turn and lock. Installed other one fastener
in the same method.
3. Using the safety cable which can withstand 10 times the weight of the equipment.
4. Make sure the X,Y protect locks are opened, Verify that within 3 meters there is no
8
combustibles .
WARNING
Fixture must use two fixing devices, and make sure the fixing device have locked! And only
fully clockwise rotate 90 ° can lock the hang fixture! Do remember plus a safety rope, and
do not connect the safety rope to plastic handle. It should be connect to the hole on the base!
4.3 FIXTURE CONNECT
Attention! One product only can accept one input one output.
EXX-ML Beam 10R 280W DMX cable include 3 contact pins:
Pin 1, FOR GROUND; Pin 2 connected to the negative polarity signal; The pin
3connected to the positive polarity signal.
DMX512 cable must use the professional shielded twisted pair cable; standard
loudspeaker cable is not reliable to control the long-range data. 24AWG cable is
suitable for more than 300 meters long-distance signal transmission and must add\
DMX 512 signal amplifier.
Do not use two outputs to separate the connection, if separate a continuous connection
to branch, DMX512 splitter is necessary.
Attention! Do not overload the connection. One continuous connection can only
connect up to 32 devices.
If use the DMX512 splitter. At first connect DMX512 Splitter input terminal to
controller .And then connected from the splitter output terminal to next device.
Do as above guide to connect other device, and finally coupled with terminal insertion
5.ALTERNATING CURRENT POWER SUPPLY
5.1 VOLTAGE, POWER, FUSE SPECIFICATION
Input Voltage
110~240V 280W 50/60Hz
Fuse voltage
250V 6A
5.2 POWER PROTECT
The equipment must be operated by professionals; Make sure that the voltage of
power supply must be comply with the voltage identified on the lamp, and must have
an overload or leakage electrical protection.
ATTENTION!
Total Power Frequency
Electronic current Specification
5×20
9
Factory has equipped the standard 3 pin plug socket. Connect the power supply as
control wheel
below table.
If lamp cable is damaged, replacement should be operate by factory or qualified
staff. Any question, please contact professionals or talk to a qualified electrician.
Live wire(L) Null(N) Ground wire
RED BLUE Yellow +Green
6. LAMP
6.1 LAMP DESCRIPTION
LAMP MODEL POWER OF LAMP LIFE/HOUR COLOR TEMPERATURE
YODN 10R 280W 2200 HOURS 8400K
WARNING! There is a safety hazard or damage if install similar bulb
To reduce the risk of damage to light ,do change the lamp before using
time over 125% of lamp life .
6.2 LAMP REPLACE
Attention! When replace the lamp is forbidden to touch lamp with bare hand, to
avoid the greasy dirt stains filament. filament must be kept clean
1. Disconnect the power. Before replace lamp, fixture need 20 minutes for lamp
cooling. Fasten the head with Y axis protect lock in 60 ° position.
2. Use cross screwdriver to open the light body cover, remove the fan bracket,
pull out the bulb cable
3. Open stainless steel tablet holder with one hand and the use other hand to pull
out the bulb at oblique 15 °
4. Install the lamp
7. CONTROL PANEL
7.1 CONTROL PANEL INTORUCTION
LCD display
Display: to display all information of fixture.
Control wheel: can turn right,left and enter.
8. EXX-ML Beam 10R 280W CONTROL
Main Menu Submenu 1 Submenu2 Function SET
Address 1-512 Address number set
"ShowReve"
"LightSet"
"LightOff"
Display
"MenuBack"
"LightFlh"
"Return " ▲return
"Natu" Normal
"Revl" reverse 180°
1%-100% Brightness set
"1MIN " Backlight close after delay 1Min
"2MIN " Backlight close after delay 2Min
"3MIN " Backlight close after delay 3Min
"Ligh" Backlight light always
Menu back to mainmenu after
"1MIN "
"2MIN "
"3MIN "
"Off " Menu back not automatic
"On " Back groud flash,open
"Off " Back groud flash,closed
dalay 1Min
Menu back to mainmenu after
dalay 2Min
Menu back to mainmenu after
dalay 3Min
Function description
"Special "
"PT Setup"
"Shortcut"
"FullColo"
"ChanlMod"
"Pan Reve"
"Tilt Reve"
"OptpChek"
"Return "
"Off " PAN SCAN Normal
"On" Pan Scan Reverse
"Off " Tilt Scan normal
"On" Tilt Scan Reverse
PAN/TILT optical sensor testing
"Off "
"On"
▲Return
"Off " Shortcust off for colors and gobos
"On"
"Off " half color function
"On" full color function
"Simp" Simplify mode
"Stan" Standard mode
"Slve" Accept other signal control
"Auto" Inside program Run automatically
"Soud" Sound active
"Off " keep signal data
"On" clear signal data
"Off " Close other signal control reset
"On" Open other signal control reset
▲Return
"Off " Lamp off
"On" Lamp on
"Off " Lamp off by manual
"On" lamp on by manual
0000-9999 Lamp time
"Off" Lamp off
"On" Lamp on
lamp off when no signal after
"10M"
10mins
lamp on(turn off lamp off
"Ligh"
▲Return
automatic)
Beam light model
Righ/Eror Fan1 State
Righ/Eror Fan2 State