HPS-C-SLOT+ Start Up Procedure
Dry cycle mold 3 – 4 times, apply full tonnage
1
(detects any pinched wires in advance of operation)
Turn “On” main disconnect
2
Select
3
automatic set point
Select Zone 1 , Zone 2
Enter automatic set point
Repeat for other zones or modules
Select
4
automatic/manual mode
Select Zone 1 , Zone 2
Enter “0” for automatic
Repeat for other zones or modules
Select Zone 1
5
Press “Up”
and “Select”
, Zone 2
Apply power to manifolds rst (heat up large mass rst)
Repeat for other zones or modules
Zones will read a low temperature alarm
6
Zones are close or holding set point when the
green temperature holding set point light is illuminated
or “both”
or “both”
. Press enter
. Press enter
or “both”
together (Power “On”)
HPS-C-SLOT+ Controller
Version 1.0 English
Basic Operation / Advanced Setup / Troubleshooting
Thermocouple Open
Thermocouple Pinched
Thermocouple Reversed
Display
Actual Row
Setting Row
Degrees C
Type K Thermocouple
Uncontrolled Output
Open Fuse
Shorted Heater
Open Heater
Alarm Status
Technical information subject to alteration • EWIKON 11/2014 • Item no. 13972E
Automatic set point
Automatic/manual mode
Press “Up” and “Select”
together (Power “On”)
Press “Down” and “Enter”
together (Power “Off”)
Zone select indication
(Press “1” and “2” together to select “both”)
Temperature holding set point (Zone “On”)
Low temperature alarm
EWIKON Heißkanalsysteme GmbH
Siegener Straße 35, 35066 Frankenberg
Tel: +49 (0)64 51/50 10 ∙ Fax: +49 (0)64 51/50 12 02
info@ewikon.com ∙ www.ewikon.com
Entry Area
Zone Select
Zone
Status
Zone ID
Zone selected
Alarm
High Alarm
Zone “On”
Low Alarm
Manual Mode
Actual Temperature
Actual % Output
Actual Current (Amps)
Automatic/Manual Mode
Manual % Output Set Point
Automatic Set Point
Select
Enter
Increment (Up)
Decrement (Down)
Power “On”
Power “Off”
Standby
Boost
First Zone (Zone 1)
Second Zone (Zone 2)
![](/html/be/beee/beeeb4a390ff3fbd257e2fdd10cdb9ea777e8ca3c139d93cd6127ea0d4fe9d64/bg2.png)
How to Enter a Set Point How to Select Automatic or Manual Optional Network Module Wiring
Enter Automatic Temperature Set Point
Select zone(s)
1
Select
2
Enter temperature set point
3
Press enter to conrm
4
Automatic set point
Press “Up” or “Down” to adjust temperature (Press “Up” and “Down” together
to hange individual digits – 100, 10 or 1)
Select
Enter
Zone select indication
(Press “1” and “2” together
to select “both”)
, or
automatic set point
Select zone(s)
1
Select
2
Enter “0” for automatic or closed loop control
3
Press enter to conrm
4
Enter “1” for manual or open loop control
, or
automatic/manual mode
Automatic/Manual mode
Select
Enter
Zone select
Manual mode light
(No light = automatic mode)
How to Turn the Power “On” & “Off”
Manual % output set point
Zone select
Enter Manual % Output Set Point
Select zone(s)
1
Select
2
Enter manual % set point
3
(0 – 99.9%)
Press enter to conrm
4
, or
manual % output set point
Select
Enter
Turn zone(s) “On”
Select zone(s)
1
Press “Up”
2
together to turn power “On”
Zone(s) “On”
Zone(s) “Off”
Press “1”, “2”, or “1 & 2” together
to select “both”
Turn zone(s) “Off”
Select zone(s)
1
Press “Down”
2
together to turn power “Off”
and “Select”
and “Enter”
, or
, or
4