EWC Controls Ultra-Zone IZT-100, Ultra-Zone IZT-250 Installation Manual

Ultra-Zone Internet Zone Thermostat Installation Guide
Release 1.0
Part No. 600-01100-100, Rev. 1 April 2007
Beta Draft Confidential
T echnical Support
When contacting EWC Controls, Inc.® for technical assistance, please have the following information available:
! Product model and serial number. ! T ype of heating/cooling system (example: gas, oil, or electric; warm air, hot water , heat pump,
steam or hybrid).
! Location and number of wires attached to your Ultra-Zone™ thermostat.
For additional assistance, please contact EWC Controls, Inc. Technical Support, 9:00 AM to 5:00 PM Eastern Standard Time Monday to Friday:
Web: www.ewccontrols.com Email: info@ewc.com Telephone: 1-800-446-3110 Fax: 1-732-446-5362
Warranty Information
EWC Controls, Inc. warrants its products to be free from manufacturing defects in materials and workmanship under normal use for a period of 1 year for the IZT-100 and the IZT-250 model thermostats from the date of purchase or the verifiable date of installation.
EWC Controls Inc. shall not be liable to honor the terms of this warranty if the product has been used in any
application other than that for which it was intended, or if it has been subjected to misuse, accidental
other damage, acts of God, modification, or improper installation procedures. Furthermore, this warranty covers
products which have all original and unaltered markings and labels (serial numbers, model numbers, etc.)
only of manufacture. This limited warranty does not cover the repair of cracked, scratched, broken or modified plastics; other cosmetic damage; or parts that have been altered, defaced or removed; or the scratching, cracking or breakage of the product. This warranty is not transferable.
THE FOREGOING W ARRANTIES ARE THE SOLE AND EXCLUSIVE WARRANTIES EXPRESSED OR IMPLIED GIVEN BY EWC CONTROLS, INC. IN CONNECTION WITH THE PRODUCT, AND
CONTROLS, INC.
WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT OF THIRD PARTY RIGHTS. EWC CONTROLS, INC. DOES NOT PROMISE THAT THE PRODUCT IS ERROR-FREE OR WILL OPERATE WITHOUT INTERRUPTION. EWC CONTROLS, INC. WILL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OR FOR ANY OTHER LOSSES, EXPENSES OR DAMAGES RELATING TO PRODUCT DEFECTS OR F AILURES. CUSTOMER'S SOLE REMEDY, AND EWC CONTROLS, INC.’S SOLE OBLIGA TION, WITH RESPECT TO ANY PRODUCT DEFECTS OR FAILURES (REGARDLESS OF WHETHER YOUR CLAIM IS ASSERTED IN CONTRACT, TORT, STRICT LIABILITY OR OTHERWISE) SHALL BE (AT EWC CONTROLS, INC.’S SOLE OPTION) REPAIR OR REPLACEMENT NO EVENT WILL EWC CONTROLS, INC.’S LIABILITY WITH RESPECT THE PRICE P AID FOR SUCH PRODUCT.
DISCLAIMS ALL IMPLIED WARRANTIES, INCLUDING IMPLIED
EWC
OF A FAULTY MODEL. IN
TO A PRODUCT, EXCEED
This warranty statement supersedes all previous warr anties. directly from an authorized
Material Return Procedure
No merchandise may be returned for credit, exchange, or service without prior aut hori za tion from EWC Controls, Inc. To obtain warranty service for Support (1-800-446-3110) and request a Return Goods Authorization (RGA) number.
Products may be returned for credit, exchange, or service with an EWC Controls, Inc. RGA number and with
purchase and installation date. Enclose a note explaining the symptoms of the problem, stating the
proof of RGA number, and the name, address and phone number of the company or individual contact. Authorized returns must be shipped prepaid to EWC Controls, Inc. at:
EWC Controls, Inc. 385 Highway 33 Englishtown, NJ 07726
ii Ultra-Zone Internet Zone Thermostat Installation Guide, Rele ase 1.0
This warranty extends to products purchased
Ultra-Zone™ dealer, wholesale distributor or agent.
Ultra-Zone™ products, contact EWC Controls, Inc. Technical
FCC Model: IZT-100 and IZT-250
Made in the USA
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
CSA Power: 24VAC 45mA 60Hz
48VDC 22mA 60Hz Switched power each contact: 24VAC 2A 60Hz
Ultra-Zone Internet Zone Thermostat Installation Guide, Release 1.0 iii Part No. 600-01100-100, Rev. 1
Beta Draft Confidential
iv Ultra-Zone Internet Zone Thermostat Installation Guide, Rele ase 1.0
Beta Draft Confidential
Overview
The Ultra-Zone Internet Zone Thermostats provide a rich set of innovative features including the ability to configure settings through a graphical interface either locally or from any remote location. The thermostats can be connected via secure wired Ethernet to a home, small business, or light commercial data network.
This guide describes how to physically install the IZT-100 and IZT-250 thermostats. Any instructions or guidelines that apply to a specific thermostat model are noted within this guide. The following model-specific features are important to note during the installation:
IZT-100
! Supports HVAC system power with 24VAC. ! Dual-Stage Fuel Burner HVAC (2h/2c). ! Single-Stage Heat Pump HVAC with auxiliary heat (2h/1c).
IZT-250
! Supports HVAC system power with 24VAC. ! Two remote thermal sensors; either Analog or Thermistor on the IZT-250. ! Dual-Stage Fuel Burner HVAC (2h/2c). ! Dual-Stage Heat Pump HVAC with auxiliary heat (3h/2c). ! Independent alarm notification on external sensors.
Installing the Thermostat
This section describes the required tools, guidelines, and installation instructions for Ultra-Zone Internet Zone Thermostats.
Preventing electrostatic discharge (ESD) — Static electricity may cause damage
Caution
to the components on the thermostat’s circuit module. Do not remove the thermostat from the protective bag until you are ready to install the thermostat.
Required Tools
The following tools are required to install the Ultra-Zone Internet Zone Thermostat:
! #1 or #2 Phillips head screwdriver. ! Drill with a 3/16” or 7/32” bit.
Ultra-Zone Internet Zone Thermostat Installation Guide, Release 1.0 1 Part No. 600-01100-100, Rev. 1
Installation Guidelines
Installation Guidelines
Use the following guidelines to install the Ultra-Zone Internet Zone Thermostat:
If you are replacing an existing thermostat, mount the Ultra-Zone Internet Zone
Tip
Thermostat in the same location as the thermostat in which you are replacing.
! Install the thermostat on an inside wall, about 5 feet (1.5m) above the floor, and in
a room that is used often.
! Install the CAT5/CAT5E/CAT6 cabling from the wiring center to the thermostat
installation site.
! Install the thermostat in an area or room with adequate air circulation and where
there are no unusual heating/cooling conditions, such as: sunlight, near a lamp, radio, television, radiator register, or fire place; near hot water pipes in a wall; near a stove on the other side of the wall, on a wall separating an unheated room; or in a draft from a stairwell, door , or window; in a corner or alcove; or behind an open door.
Beta Draft Confidential
Caution
! Install the unit after all construction work and painting is complete. ! Install the unit in an unobstructed location where there are no objects on the wall
above or below the thermostat or other obstructions (such as furniture) restricting vertical airflow.
! It is not necessary for the thermostat to be level.
Prior to installing or servicing the thermostat, turn off electricity to the entire HVAC system; do not turn electricity back on until all work is complete.
Do not jumper wires together to test the system. This may cause harm to your HVAC system and damage the thermostat, and therefore void the warranty.
All wiring must conform to local codes and ordinances. The distance between CAT5/CAT5E/CAT6 cables and HVAC cables should be a minimum of one inch.
2 Ultra-Zone Internet Zone Thermostat Installation Guide, Release 1.0
Part No. 600-01100-100, Rev. 1
Loading...
+ 12 hidden pages