EV Rider MA-1212, MA-1206 User Manual

MA-1212
R
INPUT5
Mute INPUT1
OFF
ON
0010100010100010100010100010100010
Professional Mixer/AmplifierProfessional Mixer/Amplifier
INPUT6
INPUT7
INPUT2
INPUT3
INPUT8
INPUT9
INPUT4
AUX1
INPUT10
R
+101010 +10
MASTER
010
POWER
BASS TREBLE
10
AUX2
MONITOR OUTPUT
U.S.A and Canada only. For customer orders, contact Customer Service at:
800/392-3497 Fax:800/955-6831
Europe, Afuica, and Middle East only. For customer orders, contact customer Service at:
+ 49 9427-706 0 Fax: + 49 9421-706 265
Other International locations. For customer orders, contact Customer Service at:
+ 1 952 884-4051 Fax: + 1 952 887-9212
For warranty repair or service information, contact the Service Repair department at:
800/685-2606
For technical assistance, contact Technical Support at: 886/78 AUDIO
Specifications subject to change without notice.
MA-1206 MA-1212
60 watt
120 watt
Professional Mixer/Amplifiers
Instruction Manual and Users Guide
INSTALLATION NOTES
At all times, the amplifier has to be operated under appropriate conditions. This includes that the
operation location provided sufficient ventilation and the device is not exposed to direct sunlight or the direct radiation or reflection from any heat source. Installing the loudspeaker systems choose a location that gets not affected by extreme and / or constant vibration or other mechanical oscillation. also make sure that the speakers are installed at locations that are free from dust and / or moisture.
CAUTION
We strongly recommend that you leave the connection of the appliance to the qualified and experienced service technician who is specialized in connecting electrical and electronically equipment. Do not take the risk of Electro-shock or shock hazard. To reduce the risk of Electro-shock, all connections have to be accomplished before it is permissible to connect the amplifier to the main supply, Before carried out correctly and that no short-circuit connecting the appliance to the mains supply, once again make certain that all connections are existing. The overall sound reinforcement installation has to be in accordance to the laws, regulations, standards, and guidelines that are relevant and applicable in
the country where the equipment is going to be operated.
AC POWER SUPPLY
CAUTION
This equipment operates from a power source that does not apply more than 244 VAC(r.m.s) between
conductors or between either supply conductor and ground.the supply
DC POWER SUPPLY
CAUTION
A 24V DC power source (i.e. a battery) has to be connected to the terminals (13) that are covered by a protective lid. To reduce the risk of dropping voltage to a minimum and to eliminate the danger of damaging the battery cables by thermal overload, these cables have to be at least 2.5mm in diameter, each Switching the amplifier on or off is performed through the power switch (6).
CONNECTING THE OUTPUT TERMINALS
CAUTION
TERMINALS marked with the symbol are HAZARDOUS LIVE and the external wiring connected to these TERMINALS requires installation by an INSTRUCTED PERSON or the use of ready-made lead
or cords to avoid the risk of electrical shock, the bare conductors leading to the outputnever touch
terminals of the amplifier when it is in operation. Under figures, show the possible connections of the " OUTPUT" speaker terminals accessible by removing the protective cover. Bear in mind the following rules:
Constant impedance lines
The total impedance of the speakers connected must correspond to that selected on the amplifier's
output terminals.
The sum of the power capacities of the speakers must be no lower than the amplifier's power capacity. The length of the connecting cables must be as possible; in any case, the longer the distance to be
covered and the greater must be the cross-section of the cables.
Constant voltage lines
Each speaker must be equipped with a line transformer with an input voltage equal to that of the line (25, 70, 100V). The sum of the power capacities of the speakers must not exceed the output power capacity of the
amplifier (i.e. total wattage of speakers installed in zones 1 through 5).
1
SAFETY PRECAUTIONS
1. Please read the notes proceeded by the symbol as they provide importantwith special attention, safety information.
2. The power supply voltage of the amplifier has a sufficiently high value to involve the risk of electrical shock; therefore, never install, connect, or disconnect the equipment with the power supply
switched on.
3.
The metal parts of the equipment are earthed by means of the power cable. If the power socket used to Supply power does not have an earth connection, call a qualified electrician who will earth
the equipment by means of the terminal.
Make sure that the power supply cable of the equipment cannot be trodden on or crushed by objects,
4. To ensure that the cable is not damaged.
To prevent the risk of electric shock, there are no parts inside that thenever open the equipment:
5.
can use.user
6.
Make sure that no objects or liquids can get into the speaker, as this could cause a short circuit.
7.
Never attempt to make any repairs that are not described in this manual. Contact your authorized
centers or highly qualified personnel when:service
The equipment does not function (or functions in an abnormal way). The power supply cable has been seriously damaged. Objects or liquids have got into the equipment. The equipment has been subject to heavy impact.
8. If the equipment is not to be used for long periods of time, switch it off and disconnect the power supply cable.
9. If the equipment gives off any strange oder or smoke, switch it off immediately and disconnect the
power from the supply cable.
PRECAUTIONS
Do not obstruct the ventilation grilles of the equipment. Avoid having the amplifier worked on overload for a long time. Fully tighten the screw terminals for speakers in order to ensure a safe contact. Do not force command parts (buttons, controls, etc.). When cleaning external parts, do not use thinners, spirits, or any other volatile substances. No naked flame sources, such as lighted candles, should be placed on the apparatus.
DESCRIPTION
The amplifiers in the MA-1212 series have been expressly designed for transmitting announcements
all PA sound systems. They incorporate the following functions:through
10 combination jack (XLR and 6.3mm) inputs, line/micro switchable sensitivity with excludable
phantom supply.
24V dc 2 stereo RCA input, four stage sensitivity selectable. 600 auxiliary signal(Aux. Paging) input. 1 "PRE OUT" output. 1 "MONITOR OUTPUT" and "1W/8 " slave output for monitor music signal. 1 "MAIN IN" input. Input 1 priority on the other inputs with vocal activation. Input 1, 2, 3, 4 priority on the other inputs, activation with contact. Outputs for speakers with constant impedance (4 ohm) and constant voltage (25-70-100 V). Treble and bass controls. Protection against short-circuiting between output terminals. Direct current supply 24 Vdc.
2