Evo-water soft duomatik 2 Installation Manual

INSTALLATION GUIDE
soft duomatik 2
Before introduction of the softener the installation guide has to be read carefully.
For any disturbances cause by disregarding the instructions evo-water doesn’t accept liability.
Falkenstraße 2 72589 Westerheim
Tel.: +49 7333/925710
Fax : +49 7333/9257120
www.evo-water.com
info@evo-water.com
Safety instructions:
1. Before installation the softener: Please refer to the corresponding installation – and operation instructions in this manual.
2. Please refer to the local installation regulations and the general directives, in particular DIN 1988 and EN1717, also the valid accident prevention regulations.
3. With not designated use and improper service the manufacturer is released from any liability.
4. Place of installation: Before the installation please check the statics of the walls, covers and grounds for loading capacity. According to place of action a backflow must be installed corresponding to local regulation before the arrangement. For the protection of the central tax valves from rust, sand etc. a suitable mudflap or fine filter should be inserted before the arrangement. The filter pad of the fine filters should be exchanged according to DINAR / DVGW at a distance of 6 months or after soiling. Please ensure that no water damages are caused (e.g. by ground expiry). The manufacturer is not liable for water damages . The food water of the arrangement must correspond to the information of the German drinking water order. The room temperature must be at least 7°C and may not cross 50°C.
5. Changes in the system may not be made without consultation and approval with evo-water oHG, for damages no other guarantee is taken over.
6. The system serves exclusively for the removing of undesirable mineral substances which retreat as a scale. It serves as a pure system protection.
1. A) Parts:
1.
BYPASS
8.
BLENDING REGULATOR
2.
VALVE HOUSING
9.
HARDNESS REGULATOR
3.
RESIN TANK
10.
TO BRINE VALVE
4.
SALT CONTAINER
11.
CONNECTIONS (1/2", 3/4”, 1")
5.
BRINE VALVE (floater)
12.
TO DRAIN
6.
WATER INLET
13.
COMMUNICATION TUBES
7.
WATER OUTLET
14.
TUBES TO BRINE VALVE
B) Parts Evo-water Duplex:
1.
BYPASS
9.
HARDNESS REGULATOR
2.
VALVE HOUSING
10.
TO BRINE VALVE
3.
RESIN TANK
11.
CONNECTIONS (1/2", 3/4”, 1")
4.
SALT CONTAINER
12.
TO DRAIN
5.
BRINE VALVE (floater)
13.
COMMUNICATION TUBES
6.
WATER INLET
14.
TUBES TO BRINE VALVE
7.
WATER OUTLET
15.
DEVICE CONTAINER
8.
BLENDING REGULATOR
2. Precautions:
Make sure you have all necessary tools on hand before you begin with the
installation.
Follow all local legal regulations. Read this manual carefully. If you have any questions or remarks, please
contact your supplier.
Check incoming pressure: minimum 1 bar (dynamic), maximum 8 bar (static)
(15 PSI- 116 PSI). If necessary reduce incoming pressure.
Do not install the Softener close to a heating source (environment
temperature must be below 50°C).
Protect softener and drain (12) against frost. Make sure you have the latest installation manual at hand. Check with your
supplier.
3. Installation:
3.1 Close main valve and make sure pressure is released from piping. This can be
done by opening at least one tap.
3.2 Check if all communication tubes are connected correctly.
See picture below: the two quick-release couplings marked with a green dot should be connected by a communication tube (Ø4mm); the same should be done for the two couplings marked with a blue dot.
Loading...