Evonicfires COLORADO, DETROIT, IOWA, STATON, KANSAS Installation & User's Instructions

...
Installation & User Instructions:
Models – COLORADO – IOWA – DETROIT – STATON - MEMPHIS – KANSAS –
KEPLER22
Once installed, the installer should take the appropriate steps
To ensure that the user understands how the appliance operates and
Should make the customer aware of the appliances basic service requirements.
THIS PRODUCT IS ONLY SUITABLE FOR WELL INSULATED SPACES OR OCCASIONAL USE
Safety:
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
General Warnings: Never leave children unsupervised with an unguarded heater.
Never obstruct or cover the heater outlet.
Never install or use this product where it may come in contact with water i.e. a bathroom or wet room. Never use aerosols or steam cleaners near this product. Never route the electric cable near the heater outlet. Never route the electric cable under carpets or floor coverings. Never install this product close to curtains or combustible materials. Never Use the heater to dry clothes or other objects. Never remove the fireplace surrounding without isolating the electric supply.
Important electrical safety:
This appliance must never be installed above or in front of a fixed electric socket. The electrical socket must be easily accessible to isolate the supply during maintenance and cleaning. This appliance is supplied with a two meter power lead, which has a 13Amp moulded three pin plug to connect to a standard 230/240V plug socket. This appliance must always be earthed. If in any doubt consult a suitably competent person.
All Evonic fires products meet the requirements of the EC Directives 2004/108/EC and 2006/95/EC. These directives have been met by compliance with the following standards: BS EN 60335-1:2002 BS EN 60335-2-30:2003 BS EN 6100-6-3:2001 Please read these instructions before installation or use and keep this booklet handy for future reference.
The green and yellow wire must be connected to the terminal in the plug which is marked with the letter E or the earth symbol.
The blue wire must be connected to the terminal in the plug marked with the letter N.
The brown wire must be connected to the terminal in the plug marked with the letter L.
If the plug is damaged, replace or consult a qualified electrician.
Replace fuses only with fuses of the correct size and rating.
Servicing:
Only a competent person should service this appliance. We recommend that this appliance is serviced every 12 months.
Warning: Before carrying out any repairs or servicing, ensure that the power supply cord is removed from the mains supply.
As the colours of the mains lead of this appliance may not match the coloured markings used to identify the terminals in a plug, please observe
the following:
Replacement plug: (Please note that it may invalidate your warranty is the moulded plug is removed)
This appliance must only be connected to a 230/240 Volts AC 50Hz supply. Before connecting the fire, check that the supply voltage is the same as stated on the fire. This appliance must only be used on a AC supply, fuse rating 13Amp. The wires in the mains lead are coloured in accordance with a standard UK supply, these being:
GREEN/YELLOW – EARTH BLUE – NEUTRAL BROWN – LIVE
INSTALLATION REQUIREMENTS:
INSET MODELS:
This product has been designed to be installed into a standard 420mm(W) x 570mm(H) x 80m(D)
If the products is to be installed into a open chimney or flue, it is important that the chimney/flue is blocked off to prevent any up/down draughts and falling debris which could restrict and alter the airflow to the product.
It is also important to ensure that the product has a minimum clearance around it of 15mm, this is to ensure that the product can circulate the required airflow for the heater unit.
The product should never be sealed into a opening with the use of silicones or adhesives as this can also alter the airflow and hinder any further
servicing of the product.
Please refer to technical specification table for further information, with reference to measurements. (Heater unit cut-out) (This is a safety feature, to safe guard against further damage to the product). If the airflow is restricted the heater will automatically turn off. This is can occur due to incorrect installation or obstruction.
To reset the heater function:
isolate from the mains power supply.
Leave product to cool.
After a suitable cooling down period, remove the obstruction if obstructed, and check installation.
After 10 minutes the thermo switch (cut-out) in the heater will reset.
Please note that both the effect fan and heater fan omit a low decibel noise, both of which are normal operating characteristics.
OPERATING INSTRUCTIONS
The appliance can be operated manually using the rocker switch to the right of the heater outlet, or by remote control. To operate, first press the right master switch (located on the right side of the product) which is marked (O/I) to the ( I ) position then perform the following actions:
FLAME EFFECT ONLY (NO HEAT)
Manual – Press the rocker switch on the appliance once.
Remote – Press the button marked on the remote handset.
FLAME EFFECT WITH 1Kw OF HEAT Manual – Press the second rocker switch on the appliance to the ( I ) position. Remote – Press the button marked on the remote handset.
FLAME EFFECT WITH 2Kw OF HEAT Manual – Press the third rocker switch on the appliance to the ( II ) position. Remote – Press the button marked on the remote handset.
STANDBY MODE – NO HEAT OR FLAME EFFECT Manual – Press the first rocker switch on the appliance to the ( O ) position. Remote – Press the button marked on the remote handset.
FLAME EFFECT – DIMMER FUNCTION
Manual – N/A No dimmer function on a manual control product.
Remote – Press the button marked on the remote handset once, and then again to stop the dimmer at the desired setting.
SETTING THE THERMOSTAT:
Ensure the fire is plugged in and switch it on to the full heat setting.
Turn the Control Knob fully to the right (max temperature setting) to warm the room rapidly. When the room temperature has reached the desired level, turn the thermostat knob back slowly until you
hear the thermostat just click off. The heater will then maintain the room temperature at the chosen level. Note: Should your heater fail to come on when the thermostat is at a low setting, this may be due to the
room temperature being higher then the thermostat setting.
maxmin
Fig:2) - Align the keyhole slots of the Detroit fascia with the bolts in the main body of the product.
Fig:3) – Once aligned, push the Detroit fascia over the bolts, and then push down to lock the door in position.
Attaching and removing the Detroit fascia
Fig:4) – To remove the fascia, pull in a upward motion.
Fig:5) – Then pull the fascia away from the main body.
Fig:2
Fig:3
Fig:4
Fig:5
Suggested fuel layout:
Fig:1) – Place the ceramic fuel set into
the product as shown above.
Fig:1
COLORADO FRONT GLASS REMOVAL:
1. Remove outer frame, this is held in place with magnets.
2. Remove the two screws located in the bottom glass retaining bar.
3. Remove the glass by pulling the retaining bar away from the body of the fire, ensure that this glass is supported at all times.
To install the fuel set (Logs,Pebbles,Coals) the below steps must be taken.
4. Place the fuel set (Logs,Pebbles,Coals) on the fuel bed
as to your own specification.
5. To replace the glass, please reverse the above steps.
Memphis infill plate installation
To install the Memphis infill plate please follow the below steps:
1. Remove the x2 screws located in the front plate as indicated.
2. Feed the x2 screws through the x2 holes in the Memphis infill plate.
3. Screw and fix the Memphis infill plate
to the front plate located on the fire.
Memphis-Kansas Tie back
installation
1. Screw and fix the eyelet into the top of the installation aperture. Fig:1
2. Feed the wire first through the body of the fire and then through the eyelet. Fig:2
3. Once threaded through the eyelet, feed back through the same hole on the fire body to create a loop.
4. Move the fire back into the opening, whilst pulling the excess slack of the cable tight.
5. Cut the cable 50mm away from the body of the fire.
6. Feed the straddle clamp onto the end of the wire, and screw tight. Fig:3
Fig:1
Fig:2
Fig:3
Memphis-Kansas Cast Frame
1. Once the product is installed into position.
2. Fix the Cast Fascia by hooking the tags on the rear of the cast into the cast fixing bracket. Fig:1
3. Once in position secure the cast frame by screwing the 2x M4 bolts provided thought the fascia into the body of the fire. Fig:2
4. Place Ash-pan into position.
Fig:1
Fig:2
Guarantee:
Conditions of warranty:
If this appliance should prove to be defective due to faulty design, materials or workmanship within 24 months of purchase, the product will be repaired free of charge, subject to the following conditions:
The electric fire shall have been purchased and used solely within the UK and Ireland for domestic purposes and in accordance with the Users operating instructions.
It is the purchasers responsibility to prove that the unit is under warranty, e.g. receipt of purchase.
All warranties, will be invalidated if unauthorised repairs or modifications are made to the electric fire, or in case of accident, misuse or
damage caused by improper installation, or to damage occurring during transit to or from the repairer and altered or missing serial numbers.
Any parts, which have been replaced under this warranty, shall become our property. The company shall not be liable for any consequential loss or damage what so ever, arising from or in connection with this electric fire.
This Warranty does not apply to Heating elements, Bulbs or fuses.
‘No fault found’, service calls and installation errors are not covered under the manufacturers warranty and will result in a charge being made for the Call-Out by our appointed service engineer.
This warranty is in addition to and does not affect the purchasers statutory rights of consumers.
Evonic Fires Ltd
1 Stour house, Clifford park, Clifford lane, Stratford-Upon-Avon, CV37 8HW
Tel: +44 (0) 1789 263868 Fax: +44 (0) 1789293080
Email: sales@evonicfires.co.uk Follow us on Twitter @evonicfires
Loading...