Evonic e500, e600gf, e600s, e700s, e800gf/2/3 Installation & User's Instructions

...
Installation & User Instructions:
Model: e500 - e600s – e600gf – e700s – e710 – e800gf/2/3 – e1000s – e1000gf –
e1030gf/2/3 – e1500gf/2/3 – e1800gf/2/3
Once installed, the installer should take the appropriate steps
To ensure that the user understands how the appliance operates and
Should make the customer aware of the appliances basic service requirements.
Please note: this product is only suitable for well insulated spaces or occasional use.
Safety:
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
General Warnings: Never leave children unsupervised with an unguarded heater.
Never obstruct or cover the heater outlet.
Never install or use this product where it may come in contact with water i.e. a bathroom or wet room. Never use aerosols or steam cleaners near this product. Never route the electric cable near the heater outlet. Never route the electric cable under carpets or floor coverings. Never install this product close to curtains or combustible materials. Never Use the heater to dry clothes or other objects. Never remove the fireplace surrounding without isolating the electric supply.
Important electrical safety:
This appliance must never be installed above or in front of a fixed electric socket. The electrical socket must be easily accessible to isolate the supply during maintenance and cleaning. This appliance is supplied with a two meter power lead, which has a 13Amp moulded three pin plug to connect to a standard 230/240V plug socket. This appliance must always be earthed. If in any doubt consult a suitably competent person.
All Evonic fires products meet the requirements of the EC Directives 2004/108/EC and 2006/95/EC. These directives have been met by compliance with the following standards: BS EN 60335-1:2002 BS EN 60335-2-30:2003 BS EN 6100-6-3:2001 Please read these instructions before installation or use and keep this booklet handy for future reference.
1
Servicing:
Only a competent person should service this appliance. We recommend that this appliance is serviced every 12 months.
Warning: Before carrying out any repairs or servicing, ensure that the power supply cord is removed from the mains supply.
The green and yellow wire must be connected to the terminal in the plug which is marked with the letter E or the earth symbol.
The blue wire must be connected to the terminal in the plug marked with the letter N.
The brown wire must be connected to the terminal in the plug marked with the letter L.
If the plug is damaged, replace or consult a qualified electrician.
Replace fuses only with fuses of the correct size and rating.
As the colours of the mains lead of this appliance may not match the coloured markings used to identify the terminals in a plug, please observe
the following:
Replacement plug: (Please note that it will invalidate your warranty if the moulded plug is removed and connected to a fused spur by an unqualified person)
This appliance must only be connected to a 230/240 Volts AC 50Hz supply. Before connecting the fire, check that the supply voltage is the same as stated on the fire. This appliance must only be used on a AC supply, fuse rating 13Amp. The wires in the mains lead are coloured in accordance with a standard UK supply, these being:
GREEN/YELLOW – EARTH BLUE – NEUTRAL BROWN – LIVE
2
INSTALLATION REQUIREMENTS:
BUILT IN MODELS:
This product has been designed to be installed into a studwork or existing chimney breast. Please note that any GF2 models from the e-series range are not suitable to be installed into a existing chimney breast. Please seek advice from a professional, with reference to the structural integrity of the installation site.
If the products is to be installed into a open chimney or flue, it is important that the chimney/flue is blocked off to prevent any up/down draughts and falling debris which could restrict and alter the airflow to the product.
It is also important to ensure that the product has a minimum internal clearance directly above and below the product of 50mm, this is to ensure
that the product can circulate the required airflow for the heater unit. The product should never be sealed into a opening with the use of silicones or adhesives as this can also alter the airflow and hinder any further
servicing of the product. Please refer to technical specification table for further information, with reference to measurements.
(Heater unit cut-out) (This is a safety feature, to safe guard against further damage to the product).
If the airflow is restricted the heater will automatically turn off. This is can occur due to incorrect installation or obstruction. To reset the heater function:
isolate from the mains power supply.
Leave product to cool.
After a suitable cooling down period, remove the obstruction if obstructed, and check installation.
After 10 minutes the thermo switch (cut-out) in the heater will reset.
Please note that both the effect fan and heater fan omit a low decibel noise, both of which are normal operating characteristics.