CLEANING THE EAZYPOD COMPLETE
1. Insert the cleaning pipe into the plastic return pipe
(F). This will prevent waste going back to the pond
and maintain the water level in the Pod whilst
cleaning it. See image on the right.
2. When the water level in chamber B is just level with
the overflow assembly, close slide valve (M) on your
inlet pressure line. Ensure that this is fully closed as
it is essential that this water level is maintained to
allow efficient cleaning. If there is insufficient water,
the K1 will not agitate and self clean.
3. Switch off the pond pump.
4. Turn on your air pump and open the air valve on the EazyPod Complete.
In a few seconds the K1 media will start to ‘agitate’ and circulate,
thereby self cleaning.
5. After the K1 media has been aerated for a minimum of two minutes, open valve
(K) and completely drain the EazyPod Complete.
6. Once it is drained, close valve (K).
7. Open your inlet slide valve (M) and turn on your circulation pump to refill the
EazyPod Complete.
8. When the water level in chamber B is just level with the overflow assembly,
close the slide valve (M) on your inlet pressure line and switch off the pump.
9. Allow the K1 media to agitate again for a minimum of two minutes.
10. Open valve (K) to drain again. If the water in the EazyPod Complete is still not
100% clean, repeat the process.
11. Once the K1 media is clean, turn off your air pump or re-divert it and close the
air valve on the EazyPod Complete. Close valve (K).
12. Remove the cleaning pipe.
13. Open inlet slide valve (M).
14. Start your pond pump and refill the EazyPod Complete.
PLEASE NOTE that normally 2 cleaning cycles will be needed to completely clean
the K1 media. On a dirty pond, maybe even 3 will be needed. When doing more
than one cleaning cycle, there is no need to remove the cleaning pipe and switch
the air pump off, just leave it running until the final clean when it is switched off
and the pipe removed.
15