Evolution Air DM400 Owner's Manual

OWNER’S MANUAL
MODEL DM400
WHOLE-HOUSE DUCT MOUNT
HEPA AIR CLEANER
IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT
Features
Long-life, HEPA (High Efficiency Particulate Air) Media Filter is 99.97% efficient
at removing particles 0.3 micron
MERV 11 Prefilter removes lint and large particles to extend life of HEPA Filter
Activated Carbon Prefilter removes unpleasant odours
Easy-to-change filters
Powerful motor delivers 320 CFM of filtered air
Heavy gauge steel cabinet and powder-coat paint finish provide rigid installation and durability
Plug-in Power Cord provides easy electrical connection
Duct-mountable for convenient installation
SAFETY CONSIDERATIONS
Read and follow instructions carefully. Follow all local electrical codes during installation. All wiring must conform to local and national electrical codes. Improper wiring or installation may damage the HEPA Air Cleaner.
Understand the signal words WARNING and
CAUTION which are present in the Owner’s Manual. WARNING and CAUTION signify a hazard which could
result in property damage, personal injury or death.
WARNING
Before beginning any installation or modification, be certain that the main line electrical disconnect switch is in the OFF position. Electric shock could result. Tag disconnect switch with suitable warning labels.
Only a heating/air conditioning installer or qualified service person should install, repair, or service your Whole-House HEPA Air Cleaner.
Homeowners or untrained personnel can perform the basic maintenance functions of replacing filters.
When working on air cleaning equipment, observe precautions in the Owner’s Manual, labels attached to the unit, and other safety precautions that may apply. Follow all safety codes. Wear safety glasses and work gloves.
WHAT THE HEPA AIR CLEANER DOES
The Whole-House HEPA Air Cleaner has been designed to remove particulate such as atmospheric and household dust, coal dust, insecticide dust, mites, pollen, mold spores, fungi, bacteria, viruses, pet dander, cooking smoke and grease, tobacco smoke and more. It also removes odours with the Carbon Filter.
BENEFITS
Helps provide relief from allergies, asthma, and other respiratory illness.
Helps reduce housekeeping time and redecorating costs.
Helps provide a healthier, more comfortable environment, year-round.
HOW IT WORKS
Millions of airborne pollutants are carried through the return air ducts of the heating/cooling system. The HEPA Air Cleaner has been designed to be installed on the return air duct. A portion of this return air is by­passed through an opening on the rear of the unit and passes through a 3-stage filtration system.
The air passes through an efficient pleated MERV 11 Prefilter to remove lint and large particles to extend the life of the HEPA filter.
The Activated Carbon Prefilter (activated carbon impregnated polyester filter) removes odours before they enter the HEPA filter.
Smaller particles then pass through a long-life, HEPA (High Efficiency Particulate Air) Media Filter which captures 99.97% of particles 0.3 micron (1/84,000 of an inch) and larger. This HEPA filter has more than 40 ft² of collection surface area.
Clean air is discharged back into the return air duct.
INSTALLATION
Duct Mount Installation
LOCATION
WARNING
This unit must be installed on the return air side of the system only. Do not connect to supply side. Do not install in a cooking area or connect directly to any appliance.
The HEPA Air Cleaner can be installed directly on the return air duct eliminating the need for external ducting. The unit can also be mounted on the floor, a wall or be suspended from the ceiling and with the use of collars be ducted into the return air plenum. It can also be used as a free standing unit. Care should be taken to keep the unit away from an area where there is a possibility of moisture leaking on to it. Ensure there is
13 inches in front of the unit to remove the filters for replacing.
GENERAL INSTALLATION STEPS (Duct Mount)
1. Remove any packaging, as well as the door and filters before installing. See Maintenance for instructions to remove the filters.
2. If the unit is to be mounted on the return air plenum, it must be installed after the last return branch connection on the plenum. If outside air is introduced into the return air duct, either through a HRV (Heat Recovery Ventilator) or direct, it should be added to the system before the intake inlet to the Air Cleaner.