![](/html/5b/5b91/5b9125a63dea1ff1a39ba194d4757b65b41417a3c901706e0ca1555af944cd25/bg1.png)
EVLUMA OMNIMAX
TM
INSTALLATION GUIDE
LED DECORATIVE LUMINAIRE RETROFIT
40W or 70W REPLACES HID BULBS 100-175W
Applicable Products
OMNI-40-2K-ME 40W 2000K OMNI-70-2K-ME 70W 2000K
OMNI-40-3K-ME 40W 3000K OMNI-70-3K-ME 70W 3000K
OMNI-40-4K-ME 40W 4000K OMNI-70-4K-ME 70W 4000K
OMNI-40-5K-ME 40W 5000K OMNI-70-5K-ME 70W 5000K
Fixture Requirements
Input Voltage: 120–277VAC
Frequency: 50/60Hz
Socket Base: E26 (medium) or E39 (mogul)
Fixture Minimum
Inside Dimensions:
7.0”H x 4.0”W (medium base)
8.5”H x 4.0”W (mogul base)
Orientation: Lamp can be mounted in any static orientation.
Photocontrols: If the socket is controlled by a photocontrol, it must be of a “Fail ON”
type for the OmniMax Photocontrol Failsafe™ feature to operate.
Operating Ambient
Temperature: -40°C - +40°C
Retrot Kit Contents
(1) LED retrot lamp
(1) E39 mogul adapter
(1) Fixture label
(1) Installation guide
OMNI 40
OMNI 70
SUITABLE FOR DAMP LOCATIONS.
DAPTÉ POUR ENDROITS HUMIDES.
This device complies with Part 15 of FCC Rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause undesired operation.
PLEASE READ ALL INSTRUCTIONS BEFORE ATTEMPTING INSTALLATION
WARNING - Risk of re or electric shock. LED Retrot Kit installation requires knowledge of luminaire
electrical systems. If not qualied, do not attempt installation. Contact a qualied electrician.
WARNING - When installing LED retrot lamps within HID xtures, ballast must be bypassed
when present.
WARNING - To avoid electric shock or component damage, disconnect power before attempting
installation or servicing.
WARNING - Do not make or alter any open holes in an enclosure of wiring or electrical
components during kit installation.
WARNING - To prevent wiring damage or abrasion, do not expose wiring to sharp edges of
housing or other sharp surface.
This product is intended to be installed in outdoor, ballast-based HID luminaire that have been appropriately modied.
The following xtures are representative examples of the types of xtures appropriate for OmniMax.
Acorn & Globe types: King K400 Series, Lexalite Lindy Model 424, GE Patriarch, Holophane GV Washington PostLite
Lantern types: Architectural Area Lighting Civic Lantern Series, Acuity Lighting TR25
Teardrop & Bullet types: Holophane Port Huron, HE Williams OGL Series, Acuity Lighting (Antique Street Lamps) CM
100293-001 REV A02
3600 Lind Ave SW, Suite 140, Renton, WA 98057 425-336-5800 www.evluma.com
![](/html/5b/5b91/5b9125a63dea1ff1a39ba194d4757b65b41417a3c901706e0ca1555af944cd25/bg2.png)
EVLUMA OMNIMAX
TM
INSTALLATION GUIDE
LED DECORATIVE LUMINAIRE RETROFIT
40W or 70W REPLACES HID BULBS 100-175W
OMNI 40
OMNI 70
Installation Instructions
Be careful to grip the bulb only on the upper or lower plastic housing. Avoid gripping the
bulb on the soft diffuser in the center at all times.
Step 1 – Disconnect electrical power to xture and remove existing bulb.
Step 2 – Remove or wire past the installed ballast in the xture.
Step 3 – Connect the two power leads from the source directly to corresponding leads
on the lamp socket. NOTE: The bulb screw housing of the socket shall be connected to
neutral wire (white or gray) of the power leads.
Step 4 – If the socket requires a mogul base (E39) bulb, screw the enclosed mogul
adapter (E39) into the existing screw housing of the socket before installing the bulb.
Step 5 – Thread the retrot LED bulb into the screw housing of the socket, or the mogul
adapter (E39). Tighten only until snug in the socket. CAUTION: Applying excessive
torque can damage the retrot LED bulb or xture socket.
Step 6 – Apply the supplied adhesive label to the inside of the xture where it will be
visible for future re-lamping.
Step 7 – Turn on electrical power to the xture.
3600 Lind Ave SW, Suite 140, Renton, WA 98057 425-336-5800 www.evluma.com